Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Oscillation-independent probes of nonstandard neutrino interactions from supernovae

Extreme astrophysical environments provide unique laboratories for testing fundamental neutrino interactions. We present the first oscillation-independent astrophysical probe of nonstandard neutrino interactions (NSI), using coincident neutral-current signals across diverse detectors to break degeneracies that have long limited sensitivity reach. Using self-consistent NSI supernova simulations and flavor-independent neutral-current scattering we show that anticorrelated signatures between JUNO liquid scintillator and dark matter detectors such as DARWIN/XLZD, ARGO, or RES-NOVA enable clear discrimination between NSI and flavor-conversion effects. For a Galactic supernova at Betelgeuse distance our approach enables an independent probe of neutrino-quark NSI couplings in parameter space that can reach and extend beyond current terrestrial limits. This multidetector approach enables breaking degeneracies in terrestrial searches and is broadly applicable to a wide range of upcoming experiments, establishing a new principle for testing fundamental interactions with astrophysical data.

Beatty, Angela R. [San Francisco State U.; LBL, Be↗

Application of Hybrid K-Edge Densitometry in Reprocessing Facilities

During reprocessing operations, accurately determining the elemental concentrations of uranium and plutonium is critical for nuclear security. Reprocessing facilities processes hundreds of tons of nuclear material annually, requiring accurate measurements to ensure effective nuclear material control and accountability. Hybrid K-edge densitometry (HKED) system combines K-edge absorption densitometry with x-ray fluorescence to measure actinide elemental concentrations with a low uncertainty. This system uses high-purity germanium gamma-ray detectors and advanced signal processing equipment to detect x-ray accurately. This document provides guidance on how to achieve effective performance from an HKED system for measuring uranium and plutonium concentrations in reprocessing facilities. It includes best practices for the setup and operation of an HKED system, while highlighting factors influencing uncertainties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Waveform emission location determination systems and associated methods

Waveform emission location determination systems and associated methods are described. According to one aspect, a waveform emission location determination system includes a plurality of detectors configured to receive a waveform emitted by a source and to generate electrical signals corresponding to the waveform, processing circuitry configured to access data corresponding to the electrical signals generated by the detectors, use the data to determine a plurality of spheres, and wherein a surface of each of the spheres contains a location of the source when the waveform was emitted by the source, determine an intersection of the spheres, and use the intersection of the spheres to determine the location of the source when the waveform was emitted by the source.

Hughes, Michael S.↗

Lambda baryon production in neutrino-nucleus interactions and light signals reconstruction in the Short-Baseline Near Detector

The field of neutrino physics is nowadays entering the era of precision measurements, with new detectors capable of capturing neutrino interactions with unprecedented detail and high intensity neutrino beams. Liquid Argon Time Projection Chambers (LArTPCs) have become one of the main neutrino detection technologies, providing excellent imaging capabilities and particle identification. The Short-Baseline Near Detector (SBND) at Fermilab is a LArTPC experiment designed to capture neutrinos from the Booster Neutrino Beam (BNB). Its proximity to the beam target (110\,m) and large size (112\,ton) enable the recording of millions of neutrino interactions annually. SBND provides the highest statistics worldwide for neutrino-argon cross-section measurements, facilitating the study of rare channels like Cabibbo-suppressed quasielastic hyperon production. Specifically, this thesis focuses on neutral $\Lambda$ baryon production for which only tens of events have been observed up to date. Our work introduces a novel selection strategy leveraging LArTPC imaging capabilities to identify the distinctive decay signatures of $\Lambda$ baryons, enhancing sensitivity to this channel. Besides being a very mature technology, LArTPCs are an evolving technology. Part of the focus of the new developments lies in harnessing the potential of scintillation light signals. The Photon Detection System (PDS) in SBND has been designed to provide an efficient detection of the scintillation light, representing a major R\&D opportunity in the LArTPC community. Its design provides a high and more uniform light yield, an excellent timing resolution and an independent 3D reconstruction of the events, including the drift coordinate, using exclusively the light signals. This work presents the first comprehensive study of the SBND PDS capabilities. The new developments in the simulation and reconstruction of the light signals in SBND are presented. The whole chain is applied to accurately tag neutrino events through timing information, with a predicted resolution $\mathcal{O}$(2\,ns), and ultimately retrieve the pulse structure of the BNB.

43 PARTICLE ACCELERATORS↗

Physics-inspired spatiotemporal-graph AI ensemble for the detection of higher order wave mode signals of spinning binary black hole mergers

We present a new class of AI models for the detection of quasi-circular, spinning, non-precessing binary black hole mergers whose waveforms include the higher order gravitational wave modes ($\ell$, |m|) = {(2,2), (2,1), (3,3), (3,2), (4,4)}, and mode mixing effects in the $\ell$ = 3, |m| = 2 harmonics. These AI models combine hybrid dilated convolution neural networks to accurately model both short- and long-range temporal sequential information of gravitational waves; and graph neural networks to capture spatial correlations among gravitational wave observatories to consistently describe and identify the presence of a signal in a three detector network encompassing the Advanced LIGO and Virgo detectors. We first trained these spatiotemporal-graph AI models using synthetic noise, using 1.2 million modeled waveforms to densely sample this signal manifold, within 1.7 h using 256 NVIDIA A100 GPUs in the Polaris supercomputer at the Argonne Leadership Computing Facility. This distributed training approach exhibited optimal classification performance, and strong scaling up to 512 NVIDIA A100 GPUs. With these AI ensembles we processed data from a three detector network, and found that an ensemble of 4 AI models achieves state-of-the-art performance for signal detection, and reports two misclassifications for every decade of searched data. We distributed AI inference over 128 GPUs in the Polaris supercomputer and 128 nodes in the Theta supercomputer, and completed the processing of a decade of gravitational wave data from a three detector network within 3.5 h. Finally, we fine-tuned these AI ensembles to process the entire month of February 2020, which is part of the O3b LIGO/Virgo observation run, and found 6 gravitational waves, concurrently identified in Advanced LIGO and Advanced Virgo data, and zero false positives. This analysis was completed in one hour using one NVIDIA A100 GPU.

79 ASTRONOMY AND ASTROPHYSICS↗

Detecting boosted dark photons with gaseous detectors

We search for indirect signals of O ( keV ) dark matter annihilating or decaying into O ( eV ) dark photons. These dark photons will be highly boosted, predominantly transversely polarized, have decay lengths larger than the Milky Way, and can be absorbed by neutrino or dark matter experiments at a rate dependent on the photon-dark photon kinetic mixing parameter and the optical properties of the experiment. We show that current experiments cannot probe new parameter space, but future large-scale gaseous detectors with low backgrounds (i.e., CYGNUS, NEXT, PANDAX-III) may be sensitive to this signal when the annihilation cross section is especially large. Published by the American Physical Society 2024

79 ASTRONOMY AND ASTROPHYSICS↗

Prospects for measuring the time variation of astrophysical neutrino sources at dark matter detectors

We study the prospects for measuring the time variation of solar and atmospheric neutrino fluxes at future large-scale xenon and argon dark matter detectors. For solar neutrinos, a yearly time variation arises from the eccentricity of Earth’s orbit and, for charged current interactions, from a smaller energy-dependent day-night variation due to flavor regeneration as neutrinos travel through Earth. For a 100-ton xenon detector running for ten years with a xenon-136 fraction of ≲ 0.1 % , in the electron recoil channel a time-variation amplitude of about 0.8% is detectable with a power of 90% and the level of significance of 10%. This is sufficient to detect time variation due to eccentricity, which has amplitude of ∼ 3 % . In the nuclear recoil channel, the detectable amplitude is about 10% under current detector resolution and efficiency conditions, and this generally reduces to about 1% for improved detector resolution and efficiency, the latter of which is sufficient to detect time variation due to eccentricity. Our analysis assumes both known and unknown periods. We provide scalings to determine the sensitivity to an arbitrary time-varying amplitude as a function of detector parameters. Identifying the time variation of the neutrino fluxes will be important for distinguishing neutrinos from dark matter signals and other detector-related backgrounds and extracting properties of neutrinos that can be uniquely studied in dark matter experiments. Published by the American Physical Society 2024

Zhuang, Yi (ORCID:0000000277138724)↗

Sensitivity of nEXO to 136 Xe charged-current interactions: Background-free searches for solar neutrinos and fermionic dark matter

We study the sensitivity of nEXO to solar neutrino charged-current interactions, 𝜈 𝑒 + 136 Xe → 136 Cs*+𝑒 − , as well as analogous interactions predicted by models of fermionic dark matter. Due to the recently observed low-lying isomeric states of 136 Cs, these interactions will create a time-delayed coincident signal observable in the scintillation channel. Here we develop a detailed Monte Carlo simulation of scintillation emission, propagation, and detection in the nEXO detector to model these signals under different assumptions about the timing resolution of the photosensor readout. We show this correlated signal can be used to achieve background discrimination on the order of 10 −9 , enabling nEXO to make background-free measurements of solar neutrinos above the reaction threshold of 0.668 MeV. We project that nEXO could measure the flux of neutrinos from the carbon-nitrogen-oxygen cycle with a statistical uncertainty of 25%, thus contributing a novel and competitive measurement toward addressing the solar metallicity problem. Additionally, nEXO could measure the mean energy of the 7 Be neutrinos with a precision of 𝜎 ≤ 1.5 keV and could determine the survival probability of 7 Be and pep solar 𝜈𝑒 with precision comparable to the state of the art. These quantities are sensitive to the Sun’s core temperature and to nonstandard neutrino interactions, respectively. Here, the strong background suppression would allow nEXO to search for charged-current interactions of fermionic dark matter in the mass range 𝑚 𝜒 = 0.668–7 MeV with a sensitivity up to three orders of magnitude better than current limits.

47 OTHER INSTRUMENTATION↗

The data acquisition system of the LZ dark matter detector: FADR

The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis. The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition. Furthermore, the hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Utilizing highly scattered light for intelligence through aerosols

A method for modeling light transport through a scattering medium prior to being incident on a detector and a corresponding system is disclosed. The method determines the effects of scattering and absorption caused by particles as a function of the density, size, and refractive index of the particles, as well as the wavelength of the light source. Based on the determined scattering and absorption coefficients, the signal incident on the detector may be calculated. The calculation may also be inverted such that based upon the detected signal, an object may be detected, and its location in the scattering medium may be estimated.

Bentz, Brian Z.↗

Entanglement Requirements for Coherent Enhancement in Detectors

Coherent enhancement is a powerful mechanism for improving the sensitivity of a wide range of detectors, but its practical use is often limited by the difficulty of preparing the required quantum states. We show that this difficulty has a fundamental origin: coherent enhancement of a signal interacting with a detector is quantitatively constrained by entanglement. We prove general bounds on how the strength of coherent effects can scale with system size, as a function of the single-mode entanglement entropy of the detector. These bounds smoothly interpolate between the incoherent and fully coherent regimes, and apply both to parameter-estimation problems and to scattering processes. We discuss these results from two complementary perspectives: First, they appear as bounds on the quantum Fisher information of many-body states, which translate directly into limits on parameter sensitivity via the quantum Cramér-Rao bound. Second, they can be interpreted as limits on a class of scattering cross sections, leading to predictions for how minimum detectable interaction strengths scale with target size. Together, these results provide a unified view of coherent enhancement in metrology and scattering experiments, and motivate the development of new techniques for generating entangled detector states.

Bogorad, Zachary [Fermilab] (ORCID:000000019913647↗

Improved bound on nonlinear quantum mechanics using a cryogenic radio frequency experiment

There are strong arguments that quantum mechanics may be nonlinear in its dynamics. A discovery of nonlinearity would hint at a novel understanding of the interplay between gravity and quantum field theory, for example. As such, experiments searching for potential nonlinear effects in the electromagnetic sector are important. Here, in this study, we outline such an experiment, consisting of a stream of random bits (which were generated using Rigetti’s Aspen-M-3 chip) as input to an rf signal generator coupled to a cryogenic detector. Projective measurements of the qubit state, which is originally prepared in an equal superposition, serve as the random binary output of a signal generator. Thereafter, spectral analysis of the rf detector would yield a detectable excess signal predicted to arise from such a nonlinear effect. A comparison between the projective measurements of the quantum bits vs the classical baseline showed no power excess. This sets a new limit on the electromagnetic nonlinearity parameter |ε| ⪅ 1.15 x 10 -12 , at a 90.0% confidence level. This is the most stringent limit on nonlinear quantum mechanics thus far and an improvement by nearly a factor of 50 over the previous experimental limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reducing systematic bias in machine learning applications to J/ψ signal extraction in high-energy nuclear physics

Machine learning techniques are increasingly used in high-energy nuclear physics because they can exploit multivariate correlations more efficiently than conventional cut-based analyses. A central challenge is the construction of training samples that faithfully reproduce the detector response observed in data. Signal samples are usually derived from detector simulations; therefore, mismatches between simulation and data can degrade classifier performance and introduce systematic biases. This work presents two practical correction procedures, namely cumulative distribution function (CDF) mapping and a shift-and-scale transformation, to align simulated signal features with those measured in data. Their performance is demonstrated with $J$/$\psi$ yield measurements in $\sqrt{s_{nn}}$ = 200 GeV Ru+Ru and Zr+Zr collisions recorded by STAR. A set of self-consistency tests shows that these procedures substantially suppress the systematic bias associated with data-simulation discrepancies in machine-learning-based signal extraction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Light detection and cosmic rejection in the ICARUS LArTPC at Fermilab

Abstract The ICARUS-T600 detector is a 760-ton Liquid Argon Time Projection Chamber (LArTPC) currently operating at Fermilab as the Far Detector in the Short Baseline Neutrino (SBN) program. The SBN program is composed of three LArTPCs with a central goal of testing the sterile neutrino hypothesis. After operating for 3-years in the Gran Sasso Underground Laboratory, the ICARUS detector was shipped to CERN where it was outfitted with 360 8” Photomultiplier Tubes (PMTs) for a new optical detection system. The PMT system detects fast scintillation light from charged particles interacting in the Liquid Argon, generating the trigger signal for the full detector and allows 3D reconstruction of events. Now operating at shallow depth, the detector is exposed to a high flux of cosmic rays that can fake neutrino interactions. To mitigate this effect a Cosmic Ray Tagger (CRT) and a 3-meter-thick concrete were installed. Precise timing information from both the PMT and CRT subsystems can help to identify whether an interaction originated from inside or outside of the ICARUS cryostat. This paper reviews a method for cosmogenic background reduction and timing calibration of the CRT and PMT light detection systems in ICARUS.

Instruments & Instrumentation↗

Time-of-flight vs time-of-arrival in neutron spectroscopic measurements for high energy density plasmas

The neutron time-of-flight (nToF) diagnostic technique has a lengthy history in Inertial Confinement Fusion (ICF) and High Energy Density (HED) Science experiments. Its initial utility resulted from the simple relationship between the full width half maximum of the fusion peak signal in a distant detector and the burn averaged conditions of an ideal plasma producing the flux [Lehner and Pohl, Z. Phys. 207, 83–104 (1967)]. More recent precision measurements [Gatu-Johnson et al., Phys. Rev. E 94(8), 021202 (2016)] and theoretical studies [Munro, Nucl. Fusion 56, 035001 (2016)] have shown the spectrum to be more subtle and complicated, driving the desire for an absolute calibration of the spectrum to disambiguate plasma dynamics from the conditions producing thermonuclear reactions. In experiments where the neutron production history is not well measured, but the neutron signal is preceded by a concomitant flux of photons, the spectrum can be in situ calibrated using a set of collinear detectors to obtain a true “time-of-flight” measurement. This article presents the motivation and overview of this technique along with estimates of the experimental precision needed to make useful measurements in existing and future nToF systems such as the pulsed power Z-machine located in Albuquerque, NM, at Sandia National Laboratories.

Fusion experiments↗

Photon number resolving detection with a single-photon detector and adaptive storage loop

Abstract Photon number resolving (PNR) measurements are beneficial or even necessary for many applications in quantum optics. Unfortunately, PNR detectors are usually large, slow, expensive, and difficult to operate. However, if the input signal is multiplexed, photon ‘click’ detectors, that lack an intrinsic PNR capability, can still be used to realize photon number resolution. Here, we investigate the operation of a single click detector, together with a storage line with tunable outcoupling. Using adaptive feedback to adjust the storage outcoupling rate, the dynamic range of the detector can in certain situations be extended by up to an order of magnitude relative to a purely passive setup. An adaptive approach can thus allow for photon number variance below the quantum shot noise limit under a wider range of conditions than using a passive multiplexing approach. This can enable applications in quantum enhanced metrology and quantum computing.

Sullivan, Nicholas M. (ORCID:0000000248447296)↗

Concepts for Neutrino Applications

Will neutrinos find uses outside basic science? It may be too early to say, but neutrino physicists have already imagined a variety of possibilities from the relatively modest to the more blue-sky. In this review, we survey the range of proposed applications, most involving nuclear reactors and other fission sources. We give special attention to the most recent proposals, including verifying submarine reactor integrity, safeguarding advanced nuclear power plants, and monitoring spent nuclear fuel. All of these concepts take advantage of the fact that neutrinos pass through barriers other signals cannot penetrate. That same fact creates the central challenge for neutrino applications: the size and complexity of detectors needed to collect a signal. Although the weakly interacting nature of neutrinos makes them fundamentally difficult to use, developments in detector technology are making some ideas more feasible.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of a phonon-mediated kinetic inductance detector at the NEXUS cryogenic facility

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the Northwestern EXerimental Underground Site (NEXUS) low-background facility at Fermilab for characterization and evaluation of this detector architecture’s efficacy for a DM search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470-nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of 2.1 ± 0.2 eV, a factor of two better than the current state of the art, enabled by quasiparticle lifetimes extending up to 6.5 ms. However, due to the subpercent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to σ E = 318 ± 29 eV. We further model both the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, and the observed noise spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗