Search NASA⌕ Search

SEARCH · Search NASA

Results for “SILICON RADIATION DETECTORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Infrared response measurements on radiation-damaged Si/Li/ detectors.

The improved infrared response (IRR) technique has been used to qualitatively compare radiation effects on Si(Li) detectors with energy levels reported for silicon in the literature. Measurements have been made on five commercial silicon detectors and one fabricated in-house, both before and after irradiation with fast neutrons, 1.9-MeV protons, and 1.6-MeV electrons. Effects dependent upon the extent of radiation damage have been observed. It seems likely that the photo-EMF, or photo-voltage, effect is the basic mechanism for the observation of IRR in p-i-n diodes with a wide i-region. Experimental characteristics of the IRR measurement are in agreement with those of the photovoltage effect.

Sher, A. H.↗

X-ray and energetic neutral particle emission from Saturn's magnetosphere

A description is presented of observations of the Voyager 1 spacecraft obtained a few days before encounter of the Saturn magnetosphere in November 1980. As Voyager 1 has no special experiment onboard for X-ray and neutral particle detection, the sensitivity and directional measurements of the low energy charged particle (LECP) analyzer is used to identify the neutral radiation above the charged particle background. The LECP telescope uses a silicon detector of 96.6 micrometers thickness and 0.08 sq cm area to accumulate counts in eight separate sectors near the ecliptic plane. The existence of radiation above the detector background emanating from the vicinity of Saturn, upstream from the bow shock is shown. The excess counts are most plausibly attributed to neutral radiation, that is, X rays and/or neutral energetic particles. However, in connection with quantitative considerations the observed excess counts are probably not due to X-rays. It is concluded that charge exchange of energetic ions with satellite tori is an important loss mechanism at Saturn as well as at Jupiter.

Kirsch, E.↗

Design and test of the Near Infrared Mapping Spectrometer /NIMS/ focal plane for the Galileo Jupiter Orbiter mission

A Near Infrared Mapping Spectrometer (NIMS) will fly past Jupiter on the Galileo spacecraft in 1982. The infrared detector assembly (focal plane) used in the NIMS instrument is to be passively cooled to 80 K by radiation into space. The focal plane contains 15 InSb and two silicon detectors, each with an associated dual J-FET preamp and feedback resistor. Preliminary fabrication and test experience will be described for an experimental five-channel hybrid detector assembly. Measurements of spectral noise density along with a plasma cleaning technique will also be described. The final NIMS focal plane will contain much of the design experience gained from the experimental hybrid detector assembly.

Bailey, G.↗

Novel infrared detector based on a tunneling displacement transducer

The paper describes the design, fabrication, and characteristics of a novel infrared detector based on the principle of Golay's (1947) pneumatic infrared detector, which uses the expansion of a gas to detect infrared radiation. The present detector is constructed entirely from micromachined silicon and uses an electron tunneling displacement transducer for the detection of gas expansion. The sensitivity of the new detector is competitive with the best commercial pyroelectric sensors and can be readily improved by an order of magnitude through the use of an optimized transducer.

Kenny, T. W.↗

Results from the Martian Radiation Environment Experiment MARIE

One of the three science instruments aboard the 2001 Mars Odyssey spacecraft is the Martian Radiation Environment Experiment, MARIE. MARIE consists of a stack of silicon detectors, augmented by a Cerenkov detector. MARIE is designed to measure a portion of the particle spectrum of the Galactic Cosmic Rays (GCR), as well as the high fluxes of low-energy protons (energies less than about 100 MeV) that are intermittently produced by active regions on the sun in Solar Particle Events (SPE). MARIE is providing the first detailed information about the radiation environment near Mars.measurements. MARIE has been operating successfully for nearly a year. Solar particle events of considerable interest have been observed, and data have been obtained that will yield GCR spectra from a novel observation point in the solar system.

Zeitlin, C.↗

Sky survey at far infrared wavelengths using a balloon-borne telescope

Localized sources of far infrared radiation (approximately 50 microns) have been detected during a high altitude balloon flight with a 40 cm telescope and silicon detectors. The flight system is described and preliminary results are presented. A large area of the sky has been scanned for localized sources of far infrared radiation, using a balloon-borne system that was sensitive to wavelengths beyond about 55 microns. Two Molectron silicon bolometers were used, with a Newtonian telescope having a 40 cm primary. The telescope was driven in azimuth at a fixed elevation; this mode of scanning was carried out for the duration of each of two balloon flights. The flight system is described.

Friedlander, M. W.↗

Micro-Fabricated Solid-State Radiation Detectors for Active Personal Dosimetry

Active radiation dosimetry is important to human health and equipment functionality for space applications outside the protective environment of a space station or vehicle. This is especially true for long duration missions to the moon, where the lack of a magnetic field offers no protection from space radiation to those on extravehicular activities. In order to improve functionality, durability and reliability of radiation dosimeters for future NASA lunar missions, single crystal silicon carbide devices and scintillating fiber detectors are currently being investigated for applications in advanced extravehicular systems. For many years, NASA Glenn Research Center has led significant efforts in silicon carbide semiconductor technology research and instrumentation research for sensor applications under extreme conditions. This report summarizes the technical progress and accomplishments toward characterization of radiation-sensing components for the recommendation of their fitness for advanced dosimetry development.

Wrbanek, John D.↗

Relationships between pigment composition variation and reflectance for plant species from a coastal savannah in California

Advances in imaging spectroscopy have indicated that remotely sensed reflectance measurements of the plant canopy may be used to identify and qualify some classes of canopy biochemicals; however, the manner in which differences in biochemical compositions translate into differences is not well understood. Most frequently, multiple linear regression routines have been used to correlate narrow band reflectance values with measured biochemical concentrations. Although some success has been achieved with such methods for given data sets, the bands selected by multiple regression are not consistent between data sets, nor is it always clear what physical or biological basis underlies the correlation. To examine the relationship between biochemical concentration and leaf reflectance signal we chose to focus on the visible spectrum where the primary biochemical absorbances are due to photosynthetic pigments. Pigments provide a range of absorbance features, occur over a range of concentrations in natural samples, and are ecophysiologically important. Concentrations of chlorophyll, for example, have been strongly correlated to foliar nitrogen levels within a species and to photosynthetic capacity across many species. In addition pigments effectively absorb most of the photosynthetically active radiation between 400-700 nm, a spectral region for which silicon detectors have good signal/noise characteristics. Our strategy has been to sample a variety of naturally occurring species to measure leaf reflectance and pigment compositions. We hope to extend our understanding of pigment reflectance effects to interpret small overlapping absorbances of other biochemicals in the infrared region. For this reason, selected samples were also tested to determine total nitrogen, crude protein, cellulose, and lignin levels. Leaf reflectance spectra measured with AVIRIS bandwidths and wavelengths were compared between species and within species and for differences between seasons, for changes in the the shape of the spectra. We attempt to statistically correlate these shape changes with differences in pigment compositions. In parallel with our comparisons of pigment composition and leaf reflectance, we have modified the PROSPECT leaf reflectance model to test the contributions of pigments or pigment group concentrations. PROSPECT considers a leaf as a multi-layer dielectric plane with an uneven surface. Jacquemoud adapted the basic analysis of Allen for surface effects, a leaf thickness factor, and the absorption of water and chlorophyll (actually all pigments) and the plant matrix. Our modifications to PROSPECT in the forward direction include breaking out the pigment concentration parameter into separate components for chlorophyll a and b and a number of xanthophylls and carotenes, and introducing a shift and convolution function to model the spread and shift from their in vitro measurements to their in vivo state. Further, we have considered how the matrix elements (i.e., all biochemicals and structural effects not modeled explicity) vary with species.

Ustin, Susan L.↗

Surface Passivation by Quantum Exclusion Using Multiple Layers

A semiconductor device has a multilayer doping to provide improved passivation by quantum exclusion. The multilayer doping includes at least two doped layers fabricated using MBE methods. The dopant sheet densities in the doped layers need not be the same, but in principle can be selected to be the same sheet densities or to be different sheet densities. The electrically active dopant sheet densities are quite high, reaching more than 1.times.10.sup.14 cm.sup.-2, and locally exceeding 10.sup.22 per cubic centimeter. It has been found that silicon detector devices that have two or more such dopant layers exhibit improved resistance to degradation by UV radiation, at least at wavelengths of 193 nm, as compared to conventional silicon p-on-n devices.

Hoenk, Michael E.↗

Beta decay of rb86

Measuring of rubidium 86 beta decay using lithium drifted surface barrier silicon detectors

BETA RADIATION↗

Charge Detector for the Imaging Calorimeter for ACCESS (ICA)

NASA's Advanced Cosmic Ray Experiment for the Space Station (ACCESS) Mission is planned to consist of a transition radiation detector (TRD) and a thin ionization calorimeter. In order to measure the charge of the primary cosmic ray, it is necessary for the calorimeter to have its own charge detector. Silicon detectors are chosen for the charge detector because of their excellent resolution, small size and nearly square shape. Monte Carlo simulations are performed to find the probability of misidentifying protons as alpha particles due to backscattered radiation from the calorimeter. Simulations were also used to investigate identifying primary cosmic rays that fragmented in the TRD before reaching the calorimeter. For this study algorithms have been developed for determining a direction of the core shower in the calorimeter. These algorithms are used to find the approximate location of the primary particle in the silicon detectors. Results show the probability to misidentify the charge depends upon the energy and direction of the primary particles.

Lee, Jeongin↗

Radiation damage effects by electrons, protons, and neutrons in Si/Li/ detectors.

The degradation in performance of lithium-compensated silicon nuclear particle detectors induced by irradiation at room temperature with 0.6-MeV and 1.5-MeV electrons, 1.9-MeV protons, and fast neutrons from a plutonium-beryllium source has been investigated. With increasing fluence, the irradiations produced an increase of detector leakage current, noise, capacitance, and a degradation in the performance of the detector as a charged-particle energy spectrometer. Following the irradiations, annealing effects were observed when the detectors were reverse-biased at their recommended operating voltages. Upon removal of bias, a continuous degradation of detector performance characteristics occurred. Detectors which had been damaged by electrons and protons exhibited a stabilization in their characteristics within two weeks after irradiation, whereas detectors damaged by neutrons had a continuous degradation of performance over a period of several months.

Liu, Y. M.↗

The Quantasyn, an improved quantum detector

Quantasyn provides absolute measurement of radiation flux in the range 1000 A to 4500 A and into the vacuum ultraviolet. This radiation detector cimbines the high quantum efficiency and inherent linearity of the silicon solar cell with the constant quantum response of the fluorescent organic compound liumogen.

Gorstein, M.↗

Particle Identification in the ACCESS Mission

ACCESS (Assembly Concept for Construction of Erectable Space Structures) is a planned Space Station mission to measure the elemental energy spectra of Galactic cosmic rays at energies above 100 GeV/nuc. ACCESS consists of a transition radiation detector (TRD) mounted on top of an ionization calorimeter (IC). A silicon matrix detector placed on top of the IC determines the elemental identity of each cosmic ray measured by the IC. The silicon matrix must be designed to identify each cosmic ray in the presence of backscatter from the calorimeter. Because the TRD is mounted above the IC, the matrix must also recognize cosmic rays that have interacted within the TRD before reaching the IC. We will report the results of detailed GEANT simulations of the silicon matrix in ACCESS. Results will be presented on backscatter interference with charge identification and the ability of the matrix to recognize cosmic rays that interacted in the TRD.

Wang, J. Z.↗

Holey Silicon-based Thermopiles for High-Sensitivity Broadband Thermal Detection in Space

Future planetary missions call for thermal detectors with high sensitivity over a wide range of temperature or wavelength. Conventional approaches based upon photon detectors are limited to a narrow and material-selective range of wavelength, and they often require cryogenic cooling for measurements of far-infrared (FIR) radiation or very low-temperature objects, which result in a significant increase in the system’s size, weight, and power (SWaP). While thermal detectors based upon thermopiles are uncooled and sensitive to a wide range of wavelengths including FIR radiation, their sensitivity, limited by the material’s thermoelectric response and heat losses, is an order of magnitude lower than photon detectors. To address the sensitivity requirements for future planetary science missions that target very cold objects such as ice giant planets, icy regoliths, planetary satellites, and primitive bodies, we introduce a high-sensitive broadband thermopile concept using holey silicon – a thin membrane of silicon with a microfabricated arrangement of pores that can be optimized to minimize heat losses and enable breakthrough thermoelectric performance. In this paper, we present our analytical model for the holey silicon-based thermopile, its performance expectations, and its performance comparisons with the state-of-the-art thermopile technology. We will investigate the roles of thermal conductance in holey silicon-based thermopile performance, the impact of thermal conduction and thermal radiation at different temperature limits, and the performance trade-off between the responsivity and noises.

thermopiles↗

Composite Reflective Absorptive IR-Blocking Filters Embedded in Metamaterial Antireflection Coated Silicon

Infrared (IR)-blocking filters are crucial for controlling the radiative loading on cryogenic systems and for optimizing the sensitivity of bolometric detectors in the far-IR. We present a new IR filter approach based on a combination of patterned frequency-selective structures on silicon and a thin (2575 micron thick) absorptive composite based on powdered reststrahlen absorbing materials. For a 300 K blackbody, this combination reflects approximately 50% of the incoming light and blocks greater than.99.8% of the total power with negligible thermal gradients and excellent low-frequency transmission. This allows a reduction in the IR thermal loading to negligible levels in a single cold filter. These composite filters are fabricated on silicon substrates, which provide excellent thermal transport laterally through the filter and ensure that the entire area of the absorptive filter stays near the bath temperature. A metamaterial antireflection coating cut into these substrates reduces in-band reflections to below 1%, and the in-band absorption of the powder mix is below 1% for signal bands below 750 GHz. This type of filter can be directly incorporated into silicon refractive optical elements.

Munson, C. D.↗

Vacuum UV performance of silicon detectors

The sensitivity, time-varying response, and spatial sensitivity of four silicon detectors of vacuum UV were measured by passing a typical flux of 3 x 10 photons/s at the Lyman alpha line of 1215.7 A through an exit aperture of 0.55 mm x 0.8 mm. The detectors tested were: (1) a Fairchild FPM 200 silicon planar passivated photodiode with the window removed so that radiation could directly impinge on the center of the 1.0 mm square silicon chip, (2) a Fairchild FPM 100 silicon NPN planar passivated phototransistor, (3) the Hewlett-Packard 5082-4204 silicon planar PIN photodiode, and (4) the United Detector Technology PIN Spot/2 special sensitive silicon Schottky surface photodiode with the window removed.

Ohlhaber, R. L.↗