Search NASA⌕ Search

SEARCH · Search NASA

Results for “SINGLE PHOTON DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Proposal for a quantum random number generator using coherent light and a non-classical observable

The prototype quantum random number (random bit) generator (QRNG) consists of one photon at a time falling on a 50:50 beam splitter followed by random detection in one or the other output beams due to the irreducible probabilistic nature of quantum mechanics. Due to the difficulties in producing single photons on demand, in practice, pulses of weak coherent (laser) light are used. In this paper, we take a different approach, one that uses moderate coherent light. It is shown that a QRNG can be implemented by performing photon-number parity measurements. For moderate coherent light, the probabilities of obtaining even or odd parity in photon counts are 0.5 each. Photon counting with single-photon resolution can be performed through use of a cascade of beam splitters and single-photon detectors, as was done recently in a photon-number parity-based interferometry experiment involving coherent light. We highlight the point that unlike most quantum-based random number generators, our proposal does not require the use of classical de-biasing algorithms or post-processing of the generated bit sequence.

Gerry, Christopher C.↗

A 32-Channel Cryo-CMOS ASIC for SNSPD Biasing and Readout with Picosecond Timing

Superconducting nanowire single-photon detectors (SNSPD) are a promising technology for particle detection. Although SNSPDs have demonstrated picosecond timing accuracy, scaling up large arrays has proved challenging. In this work, we introduce a 32-channel cryo-CMOS application-specifc integrated circuit (ASIC) that can be tightly integrated with SNSPD arrays. The ASIC is designed to operate at a temperature of 4K and can perform up to 32 simultaneous timing measurements with a root-mean-square (RMS) accuracy of 8.0ps. The ASIC includes on-chip circuitry for externally biasing superconducting devices, low-noise amplifers for reading superconducting devices, high-resolution time-to-digital converters (TDC) for time-tagging events, and serializers for transmitting data to room-temperature electronics. The ASIC is manufactured in a 22nm FDSOI process and occupies an area of 4.0mm x 1.0mm. The performance of the ASIC was verifed using custom cryogenic device models internally developed for the 22nm SOI process. Measurement results will be presented at the conference.

Fredenburg, Jeff↗

Quantum Random Walk Simulator Using Ultrafast Optical Switches

Quantum random walk processes have many intriguing applications in high energy physics including the simulation of parton shower evolution. We will present the design and initial results of a fiber loop time-bin quantum walk architecture using the hardware platform already in operation at the Fermilab Quantum Network in which the state of the photon is defined by its time-of-arrival. The fiber loop consists of an unbalanced Mach-Zehnder interferometer implemented using an ultrafast electro-optical switch. The input switch controls the photon path within the interferometer, while the output switch will direct the photon back into the interferometer or to single photon detectors to measure the probability distribution of arrival times. Depending on which path the photon takes each pass through the loop, its wave function will interfere on these optical switches similar to quantum interference on a beam splitter. This work is an important step towards utilizing real-world advantages of quantum information protocols to solve problems in high energy physics.

Cameron, Andrew [Fermilab]↗

Towards High-Efficiency Particle Detection Using Superconducting Microwire Arrays

We present a detailed study of an 8-channel $1\times1$~mm$^{2}$ WSi superconducting microwire single photon detector (SMSPD) array exposed to 120~GeV hadron beam and 120~GeV muon beam at the CERN Super Proton Synchrotron H6 beamline. Following up on our first detailed characterization of the efficiency and response of an SMSPD fabricated on a 3~nm WSi film, we report measurements of enhanced particle detection efficiency using a sensor fabricated from a thicker 4.7~nm-thick WSi film. We also report the first SMSPD detection efficiency measurement made for muons. Measurements are enabled by a silicon tracking telescope providing 10~$\mu$m in situ spatial resolution. The results show a detection efficiency of 75\% and a time resolution of about 130~ps across pixels. These findings represent a significant advancement toward developing high-efficiency SMSPD charged particle tracking systems with simultaneous precision timing, with potential applications in future accelerator-based experiments such as the FCC-ee and Muon Collider.

Wang, Christina [Fermilab]↗

Quantum enabled precision measurements of the 229Th nuclear isomer transition (final report)

The existence of the nuclear isomer transition in thorium-229 was first inferred from keV lines in the gamma spectrum of uranium-233 decay more than 40 years ago. Over the years, the value of the transition energy has been refined with indirect measurements using nuclear physics techniques, and the current evidence points to transition energy in the laser-accessible vacuum ultra-violet region of the spectrum. At the start of this project, the two best measurements of the transition energy were 7.8±0.5 eV and 8.28±0.17 eV from high precision gamma ray spectroscopy and kinetic energy of internal conversion electrons, respectively. This project aimed to reduce the uncertainty in the transition energy to 10 meV using direct calorimetric measurements of the decay energy with superconducting nanowire single photon detectors (SNSPDs). Specifically, the method that was pursued was to generate thorium-229 in the excited isomer state by the alpha decay of uranium-233, embed the excited state thorium into an SNSPD, then detect the energy released when the isomer deexcites.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impedance matched superconducting nanowire photodetector for single- and multi-photon detection

Conventional readout of a superconducting nanowire single-photon detector (SNSPD) sets an upper bound on the output voltage to be the product of the bias current and the load impedance, IB×Zload, where Zload is limited to 50Ω in standard RF electronics. This limit is broken/exceeded by interfacing the 50Ω load and the SNSPD using an integrated superconducting transmission line taper. The taper is a transformer that effectively loads the SNSPD with high impedance without latching. The taper increases the amplitude of the detector output while preserving the fast rising edge. Using a taper with a starting width of 500 nm, a 3.6× higher pulse amplitude, 3.7× faster slew rate, and 25.1 ps smaller timing jitter was observed. The taper also makes the detector's output voltage sensitive to the number of photon-induced hotspots and enables photon number resolution.

Zhu, Di↗

Laser Characterization of Optically Smooth BREAD parts

The Broadband Reflector Experiment for Axion Detection is a dish antenna experiment probing the axion and dark photon parameter space in the [1 μeV, 1 eV] mass range, or [.02, 200] THz frequency range. In the pilot design for the InfraBREAD model, the dish antenna includes an optically smooth coaxial parabolic reflector to focus incoming photons in the near Infrared spectrum, created by the spontaneous photoconversion of axions and dark photons, onto a Superconducting Nanowire Single Photon Detector at the focus point of the reflector. As the pilot begins as a dark photon detector, sensitivity estimates hypothesize that it could cover unprobed parameter space in the search for the dark photon. Because of this, it is of critical importance that the reflector and SNSPD be placed at the correct points in the dish antenna, as previous work has shown that in addition to the focal spot of the photons being smeared to an area larger than the SNSPD, detection efficiency is s ensitive to shifts on the millimeter scale. In order to constrain this barrier to efficiency, the reflector had its focal spot, roughness, and length of surface waves measured by lasers in an optical bench setup. Results show the focal point diverging slightly from its theorized position in the antenna, while uncertainty in the height at which the detector should be placed was constrained to 10s of microns, the uncertainty in radial position could not be constrained to smaller than the detector given the methods used. Results for the roughness and surface wavelength show that the reflector was uniformly machined in a diamond-turning process used to fabricate optically smooth parts, as well as support a roughly 90% detection efficiency, reinforcing the sensitivity estimates presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PhotonIDs: ML-Powered Photon Identification System for Dark Count Elimination

Reliable single photon detection is the foundation for practical quantum communication and networking. However, today's superconducting nanowire single photon detector(SNSPD) inherently fails to distinguish between genuine photon events and dark counts, leading to degraded fidelity in long-distance quantum communication. In this work, we introduce PhotonIDs, a machine learning-powered photon identification system that is the first end-to-end solution for real-time discrimination between photons and dark count based on full SNSPD readout signal waveform analysis. PhotonIDs ~demonstrates: 1) an FPGA-based high-speed data acquisition platform that selectively captures the full waveform of signal only while filtering out the background data in real time; 2) an efficient signal preprocessing pipeline, and a novel pseudo-position metric that is derived from the physical temporal-spatial features of each detected event; 3) a hybrid machine learning model with near 98% accuracy achieved on photon/dark count classification. Additionally, proposed PhotonIDs ~ is evaluated on the dark count elimination performance with two real-world case studies: (1) 20 km quantum link, and (2) Erbium ion-based photon emission system. Our result demonstrates that PhotonIDs ~could improve more than 31.2 times of signal-noise-ratio~(SNR) on dark count elimination. PhotonIDs ~ marks a step forward in noise-resilient quantum communication infrastructure.

Linne, Karl C. [Chicago U.] (ORCID:000900091870358↗

Improved Heralded Single-Photon Source with a Photon-Number-Resolving Superconducting Nanowire Detector

Deterministic generation of single photons is essential for many quantum information technologies. A bulk optical nonlinearity emitting a photon pair, where the measurement of one of the photons heralds the presence of the other, is commonly used with the caveat that the single-photon emission rate is constrained due to a trade-off between multiphoton events and pair emission rate. Using an efficient and low noise photon-number-resolving superconducting nanowire detector we herald, in real time, a single photon at telecommunication wavelength. We perform a second-order photon correlation g 2 ( 0 ) measurement of the signal mode conditioned on the measured photon number of the idler mode for various pump powers and demonstrate an improvement of a heralded single-photon source. We develop an analytical model using a phase-space formalism that encompasses all multiphoton effects and relevant imperfections, such as loss and multiple Schmidt modes. We perform a maximum-likelihood fit to test the agreement of the model to the data and extract the best-fit mean photon number μ of the pair source for each pump power. A maximum reduction of 0.118 ± 0.012 in the photon g 2 ( 0 ) correlation function at μ = 0.327 ± 0.007 is obtained, indicating a strong suppression of multiphoton emissions. For a fixed g 2 ( 0 ) = 7 × 10 − 3 , we increase the single pair generation probability by 25%. Our experiment, built using fiber-coupled and off-the-shelf components, delineates a path to engineering ideal sources of single photons.

Davis, Samantha I.↗

UV hybrid photon detector based on GaN photocathodes and Si low gain avalanche diode

Photon detectors featuring single-photon sensitivity play a crucial role in various scientific domains, including high-energy physics, astronomy, and quantum optics. Fast response time, high quantum efficiency, and minimal dark counts are the characteristics that render them ideal candidates for detecting individual photons with exceptional signal-to-noise ratios, at frequencies in the range of hundreds of MHz. Here, in this study, we report on our first design and operational results on a Hybrid Photon Detector (HPD) that combines the high quantum efficiency of a Gallium Nitride (GaN) photocathode and the low noise characteristics of a Si-based Low-Gain Avalanche Diode (LGAD). This hybrid detection scheme has the potential to reach single-photon detection sensitivity with high quantum efficiency, low noise levels and capable of operating at hundreds of MHz repetition rates.

47 OTHER INSTRUMENTATION↗

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Methylammonium Lead Tribromide Single Crystal Detectors towards Robust Gamma-Ray Photon Sensing

In recent years, hybrid perovskite single crystalline solid-state detectors have shown promise in γ-ray spectroscopy. Here, the γ-ray photon induced electrical pulses are investigated, which are produced by perovskite solid-state detectors made with the commonly used methylammonium lead tribromide crystals with chlorine incorporation. Under low electric field detector operation, slow pulses generated by γ-rays with average rise times of 65 µs are observed, which decreases to 20 µs when a higher electrical field of 500 V cm -1 is applied. However, the baseline becomes noisy quickly, which prevents collection of clean pulses for spectra construction. Further, by systematically measuring the temperature dependence and current–voltage characteristics, such instability is attributed to the local ion migration under electrical field creating a fluctuating dark noise, which presents a major challenge in perovskite γ-ray detector technologies. It is demonstrated that cycling the bias between positive and negative polarity can stabilize the detector, allowing for longer periods of pulse accumulation for generating energy resolved spectra with resolutions of ≈35% at 59.6 keV and ≈25% at 662 keV at room temperature. The study indicates that the main limiting factors of perovskite-based γ-ray detectors are slow rise times and bias instability. Finally, these challenges must be properly addressed to achieve reproducible, high-resolution γ-ray detection.

47 OTHER INSTRUMENTATION↗

Spectral characterization of an SPDC source with a fast broadband spectrometer

Knowing the properties of single photons produced in a Spontaneous Parametric Down-Conversion (SPDC) source can be crucial for specific applications and uses. In particular, the spectral properties are of key relevance. Here, we investigate a commercial SPDC source using our fast broadband spectrometer. Our analysis is a valid method for other SPDC sources, as well as other single-photon generation techniques, thus providing a good example of how to use this spectrometer design. We calibrate the spectrometer using known lines of the argon emission spectrum. We show that the two down-converted photons from the SPDC source have different spectral properties depending on the pump power, and under which condition we measured spectrally similar down-converted photons. Finally, we were able to reconstruct and investigate the spectral information for the pump photon.

79 ASTRONOMY AND ASTROPHYSICS↗

Charge collection and trapping mechanisms in hexagonal boron nitride epilayers

Understanding charge collection and trapping mechanisms is crucial for using hexagonal boron nitride (h-BN) as active layers for many photonic and electronic devices such as deep UV detectors and emitters, neutron detectors, and single photon emitters. Charge collection and trapping mechanisms in h-BN epilayers have been investigated by probing impurity related optical emissions under an applied electrical field. Our results suggested that the existence of oxygen impurities affects the charge collection efficiency and results in an additional emission peak at 3.75 eV, corresponding to a donor-acceptor pair (DAP) recombination involving O N (oxygen residing on the nitrogen site) donors and the V B -H (boron vacancy bonded with hydrogen complex) deep level acceptors. Experimental results further revealed that the applied electric field induces an anti-correlation between the emission intensity of the DAP transition and the charge collection efficiency from which it was shown that it is possible to find an expression to quantitatively measure the maximum charge collection efficiency in h-BN. The results introduce not only a coherent picture for the relationship between common impurities in h-BN and charge collection and trapping mechanisms but also useful insights into possible approaches to improve the quality, purity, and charge collection of the h-BN epilayers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

GRAPH — an readout ASIC for large MCP based detectors

We present a programmable 16 channel, mixed signal, low power readout ASIC, having the project historically named Gigasample Recorder of Analog waveforms from a PHotodetector (GRAPH). It is designed to read large aperture single photon imaging detectors using micro channel plates for charge multiplication, and measuring the detector's response on crossed strips anodes to extrapolate the incoming photon position. Each channel consists of a fast, low power and low noise charge sensitive amplifier, which provides a myriad of coarse and fine programmable options for gain and shaping settings. Further, the amplified signal is recorded using, to our knowledge novel, the Hybrid Universal sampLing Architecture (HULA) ADC. A kind of mixed signal double buffer memory, that enables concurrent waveform recording, and selected event digitized data extraction. The sampling frequency is freely adjustable between few kHz up to 125 MHz, while the chip's internal digital memory holds a history 2048 samples for each channel, with a digital headroom of 12 bits. An optimized region of interest sample-read algorithm allows to extract the information just around the event pulse peak, while selecting the next event, thus substantially reducing the operational dead time. The chip is designed in 130 nm TSMC CMOS technology, and its power consumption is around 47 mW per channel.

47 OTHER INSTRUMENTATION↗

Highly excited electron cyclotron for QCD axion and dark-photon detection

We propose using highly excited cyclotron states of a trapped electron to detect meV axion and dark-photon dark matter, marking a significant improvement over our previous proposal and demonstration [One-electron quantum cyclotron as a milli-ev dark-photon detector, .]. When the axion mass matches the cyclotron frequency ω c , the cyclotron state is resonantly excited, with a transition probability proportional to its initial quantum number, n c . The sensitivity is enhanced by taking n c ∼ 10 6 ( 0.1 meV ω c ) 2 . By optimizing key experimental parameters, we minimize the required averaging time for cyclotron detection to t ave ∼ 10 − 6 s, permitting detection of such a highly excited state before its decay. An open–end-cap trap design enables the external photon signal to be directed into the trap, rendering our background-free detector compatible with large focusing cavities, such as the BREAD proposal, while capitalizing on their strong magnetic fields. Furthermore, the axion conversion rate can be coherently enhanced by incorporating layers of dielectrics with alternating refractive indices within the cavity. Collectively, these optimizations enable us to probe the QCD axion parameter space from 0.1 to 2.3 meV (25–560 GHz), covering a substantial portion of the predicted postinflationary QCD axion mass range. This sensitivity corresponds to probing the kinetic mixing parameter of the dark photon down to ε ≈ 2 × 10 − 16 . Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗