Search NASA⌕ Search

SEARCH · Search NASA

Results for “SLIP BAND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

70 records · Page 4

Comparison of viscous shock layer and boundary layer reentry heating techniques for Orbiter nose cap

A comparison of two viscous shock layer methods and one boundary layer method for predicting the aerodynamic heating around the Orbiter nose cap during STS-5 entry is presented. The object of the study was to compare these methods with one another and with the measured Orbiter flight data for this trajectory. The nonequilibrium, chemically reacting viscous flow fields obtained by these methods are evaluated, and effects on heating rate of wall catalycity variation with time are presented. The effects of shock slip and combined wall/shock slip are considered at high altitudes (above 300,000 ft). Using the variable wall catalycity analysis, it is shown that heating rates can be predicted within a 5.7 percent flight data band for altitudes between 175,000 ft and 265,000 ft in this trajectory.

Ting, P. C.↗

Arcing in space structures in low Earth orbit

This report describes results of an experimental and theoretical program to investigate arcing of structures containing dielectric and conducting materials when they are biased negatively with respect to a plasma. An argon ion source generated Ar(+) ions of directed energy 20 to 40 eV and density approximately 10(exp 7) cm(exp -3) that impinged upon samples containing a dielectric material on top of a negatively biased Kovar plate. Arcing events were studied for bias voltages between -300 and -1000V with respect to the ion beam. The samples were Dow Corning 93-500 adhesive on Kovar, fused silica cover slips bonded on Kovar, and silicon solar cells mounted on Kovar. Measurements of discharge current, Kovar plate voltage, and radiation from the arc versus time were carried out. Microsecond duration exposure images and optical spectra in the 0.24 to 0.40 micron band were also acquired during arcing events. Arcing events were found to be associated with exposed adhesive and means were found to eliminate arcing altogether. The charging of a silica cover plate and the fields around the plate were calculated using a particle-in-cell code. Models were developed to explain the ignition of the arc and the physical processes occurring during the discharge.

Upschulte, B. L.↗

Detection and Location of Transverse Matrix Cracks in Cross-Ply Gr/Ep Composites Using Acoustic Emission

Transverse matrix cracking in cross-ply gr/ep laminates was studied with advanced acoustic emission (AE) techniques. The primary goal of this research was to measure the load required to initiate the first transverse matrix crack in cross-ply laminates of different thicknesses. Other methods had been previously used for these measurements including penetrant enhanced radiography, optical microscopy, and audible acoustic microphone measurements. The former methods required that the mechanical test be paused for measurements at load intervals. This slowed the test procedure and did not provide the required resolution in load. With acoustic microphones, acoustic signals from cracks could not be clearly differentiated from other noise sources such as grip damage, specimen slippage, or test machine noise. A second goal for this work was to use the high resolution source location accuracy of the advanced acoustic emission techniques to determine whether the crack initiation site was at the specimen edge or in the interior of the specimen.In this research, advanced AE techniques using broad band sensors, high capture rate digital waveform acquisition, and plate wave propagation based analysis were applied to cross-ply composite coupons with different numbers of 0 and 90 degree plies. Noise signals, believed to be caused by grip damage or specimen slipping, were eliminated based on their plate wave characteristics. Such signals were always located outside the sensor gage length in the gripped region of the specimen. Cracks were confirmed post-test by microscopic analysis of a polished specimen edge, backscatter ultrasonic scans, and in limited cases, by penetrant enhanced radiography. For specimens with three or more 90 degree plies together, there was an exact 1-1 correlation between AE crack signals and observed cracks. The ultrasonic scans and some destructive sectioning analysis showed that the cracks extended across the full width of the specimen. Furthermore, the locations of the cracks from the AE data were in excellent agreement with the locations measured with the microscope. The high resolution source location capability of this technique, combined with an array of sensors, was able to determine that the cracks initiated at the specimen edges, rather than in the interior. For specimens with only one or two 90 degree plies, the crack-like signals were significantly smaller in amplitude and there was not a 1-1 correlation to observed cracks. This was similar to previous results. In this case, however, ultrasonic and destructive sectioning analysis revealed that the cracks did not extend across the specimen. They initiated at the edge, but did not propagate any appreciable distance into the specimen. This explains the much smaller AE signal amplitudes and the difficulty in correlating these signals to actual cracks in this, as well as in the previous study.

Prosser, W. H.↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

Kenneth J Pederson↗

Challenges Associated with In-Situ Calibration of Load Cells in Force Limited Vibration Testing

The difference in mounting configuration between flight and test can significantly impact the effectiveness of the test in environmental vibration testing. Many tests are performed with large electrodynamic shakers, which utilize interfaces that seek to replicate a fixed base, such as slip tables and head expanders. This fixed base configuration is rarely seen in flight configurations; rather a more realistic configuration would include a flexible mounting structure with its own compliance and dynamics. This causes significant over and under tests in various frequency bands depending on the differences between the test article and fixture dynamics. The traditional way of avoiding these high loads is to limit the acceleration responses at multiple locations on the test article. However, the effectiveness of this approach is highly dependent upon the validity of the test article’s analytical in order to derive accurate acceleration response limit specifications. Also this technique requires limiting the acceleration responses at many locations throughout the test article, which may not be implementable due to such things as access and cleanliness issues An improved environmental vibration testing technique known as force limiting incorporates measurements of the forces between the test article and shaker system interface and limiting them to a specification that more accurately replicates the interface impedance of the structure the test article will be mounted to in flight. In effect this transforms the high mechanical impedance at the test article to shaker interface to more closely match the mechanical impedance of the flight interface, which avoids producing the unrealistically high interface loads. Typically force gauges or load cells are used to measure these interface forces. However, utilizing load cells can present a multitude of challenges depending upon such things as their installation method, geometric layout, and test fixture setup. Regardless, it is extremely important to perform an in-situ calibration of the load cells prior to vibration testing at any significant levels. This paper will discuss the challenges associated with utilizing load cells during the NASA Evolutionary Xenon Thruster – Commercial (NEXT-C) gridded ion thruster proto-flight vibration test performed at the NASA Glenn Research Center’s Structural Dynamics Laboratory.

K. J. Pederson↗

Transpression as the main deformational event in an Archaean greenstone belt, northeastern Minnesota

Deformed and metamorphosed sedimentary and volcanic rocks of the Vermilion district constitute an Archean greenstone belt trending east-west between higher grade rocks of the Vermilion Granitic Complex to the north and the Giants Range batholith to the south. Metamorphic grade is low throughout, being lowest in the center of the belt (chlorite zone of the greenschist facies). All the measured strain, a cleavage or schistosity, and a mineral lineation in this belt are attributed to the main phase of deformation D sub 2 that followed an earlier nappe-forming event D sub 1, which left little evidence of penetrative fabric. Previous work assumed that the D sub 2 deformation resulted from north-south compression across the district. It is now believed that a significant component of this deformation resulted from dextral shear across the whole region. Thus the Vermilion fault, a late-state largely strike-slip structure that bounds the Vermilion district to the north, may simply be the latest, most brittle expression of a shear regime that was much more widespread in space and time. Features that are indicative of shear include ductile shear zones with sigmoidal foliation patterns, highly schistose zones with the development of shear bands, feldspar clasts or pyrite cubes with asymmetric pressure shadows, and the fact that the asymmetry of the F sub 2 folds is predominantly Z for at least 15 km south of the Vermilion fault.

Hudleston, P. J.↗

Ku band deployed assembly and gimbal

Requirements for shuttle orbiter missions to locate satellites for servicing and to communicate when out of touch with a direct ground link were established. A Ku Band deployed antenna system providing an integrated radar and communications function was designed to meet these requirements. The unique features of the gimbal assembly are described with emphasis on the following: edge mounted antenna to minimize stowage volume in shuttle and maximize gain; unique two axis housing and shaft arrangement to accommodate two runs of waveguide and 55 electrical conductors without requiring slip rings; maximum use of aluminum in gimbal structure to reduce costs; and lubricant chosen to survive Earth and space environments.

Deal, T. E.↗

Solar plasma: Viking 1975 interplanetary spacecraft dual-frequency Doppler data

Viking 1975 interplanetary S- and X-band Doppler data are surveyed. These data show consistency with differenced range versus integrated Doppler (DRVID) data when there is solar plasma and with Faraday rotation data otherwise. An increase of solar plasma effects with decreasing sun-earth-probe (SEP) angle (approaching Mars orbit insertion) is demonstrated. The 2-way/3-way data indicate a homogeneous solar plasma structure over a 8,000-km spread. Occasional cycle slips in the data are pinpointed and tabulated.

Wu, S. C.↗

Photogeological analysis of Europan tectonic features

Preliminary photogeological analyses of the Pelorus Linea and Sidon Flexus regions of Europa were conducted to explore the proposal by Schenk that lateral motion of crustal blocks has occurred in a 'rift zone' including possible strike-slip, tension fracturing, and geometric plate rotation about an Euler pole. These analyses revealed features interpreted as tensional structures and block rotation in a strike-slip regime consistent with the Schenk hypotheses and implied the presence of at least two stages of crustal deformation consistent with a chronology developed by Lucchitta. Confirmation of regional scale Euler pole rotation was ambiguous, however. Up to 80 kilometers of possible extension was identified in the rift zone; to accommodate this, 'cryosubduction' is speculatively proposed as a mechanism for recycling Europan 'ice lithosphere'. The cumulative width of wedge-shaped bands included in the rift zone was measured and plotted versus distance from the inferred rotation pole. Three sharp decreases in the total width were noted. These occur roughly where certain triple bands cross the rift zone suggesting that the bands are structural features that predate and influence the zone. While the curve hints at one or more sinusoidal relationships consistent with rotation geometry, given the low photographic resolution and the preliminary nature of this examination the question of whether the observations represent coherent regional rotation modified by crosscutting structures or instead imply independent local rotations separated by these structures is unanswered by this analysis.

Tufts, B. R.↗

Cool Sportswear

New athletic wear design based on the circulating liquid cooling system used in the astronaut's space suits, allows athletes to perform more strenuous activity without becoming overheated. Techni-Clothes gear incorporates packets containing a heat-absorbing gel that slips into an insulated pocket of the athletic garment and is positioned near parts of the body where heat transfer is most efficient. A gel packet is good for about one hour. Easily replaced from a supply of spares in an insulated container worn on the belt. The products, targeted primarily for runners and joggers and any other athlete whose performance may be affected by hot weather, include cooling headbands, wrist bands and running shorts with gel-pack pockets.

Source record↗

A high-power communications technology satellite for the 12 and 14 GHz bands.

Description of the mission, subsystems and communication capabilities of a joint Communications Technology Satellite (CTS) scheduled for launch in 1975 by the Canadian Department of Communications in cooperation with NASA. The principal objectives of the mission are TV transmission at 12 GHz to low-cost ground terminals, up-link TV transmission at 14 GHz transportable terminals, and flight tests of spacecraft subsystems and components for future communications satellites. The major advanced spacecraft subsystems are a novel superefficiency TWT design, a 0.4 mlb Mercury Bombardment ion engine for north-south station keeping, a 3-axis stabilization system to maintain a high antenna boresight pointing accuracy, a liquid metal slip ring experiment, and a lightweight extendible solar array with an initial power output greater than 1 kW.

Franklin, C. A.↗

Surface Deformation Due to the May 27, 1995 Sakhalin Earthquake and Related Events Measured by JERS-1 SAR Interferometry

A large (M&subw;=7.0) earthquake on May 27, 1995 completely destroyed the town of Neftegorsk in the northern part of Sakhalin Island and caused more than 2000 human deaths. The shallow, right-lateral, strick-slip earthquake resulted in extensive surface ruptures and up to 7 m of horizontal displacement as reported by field workers. The sourthern part of the mainshock epicenter zone was imaged by the JERS-1 SAR (synthetic aperature radar) one month (April 28) before and two weeks after (June 11) the mainshock. Despite drastically changed surface conditions in the 44 days between the two images, due primarily to spring thaw, we obtained reasonably good interferometric correlation with the L-band (24 cm) SAR pair. The interoferogram records the distribution of deformation reflecting displacement during both the mainshock and aftershocks. The ability to map the deformation pattern can aid the assessment and mitigation of damage.

Sakhalin Island JERS-1↗

Slip Analysis in a Ni-base Superalloy

A Ni-base superalloy single crystal with Gamma/Gamma' structure was tested at room temperature along the , <110> and <111> directions. Consistent with previously reported investigations, this alloy did not obey the Schmid law and the CRSS (critical resolved shear stress) was noticeably lower for the <111>-oriented samples. Furthermore, the strain hardening rate decreased and the degree of deformation localization increased in the order of <111>, and <110> orientations. The appearance and orientation of deformation traces were found to depend on the loading orientation as well as the amount of strain. In general, when Gamma'-particles were sheared, the traces followed the expected octahedral shear planes. It is demonstrated that the wavy deformation traces that do not follow the {111} planes are associated with changes in the gamma-channels width and the falling off of the gamma-particles. In this paper the evolution of deformation bands are discussed in terms of plastic localization at microscopic, mesoscopic and macroscopic levels.

Westbrooke, Eboni F.↗

Structural interpretations based on ERTS-1 imagery, Bighorn Region, Wyoming-Montana

Structural analysis is being carried out on bands MSS 5 and 7 of scene 1085-17294. Geologic strucutre is primarily revealed in the topographic relief and drainage. Topographic linears are particularly well developed in the bighorn uplift. Many of these occur along known faults and shear zones in the Precambrian core; several have not been previously mapped. These linears, however, do not continue into the younger rocks of the flanks or do so in a much less marked manner than in the core. Linears are far less abundant in the basin or are manifested only in very subtle tonal contrasts and somewhat straight drainage segments. Some of the linears are aligned along trends previously postulated on the basis of surface mapping to be lineaments. The imagery reveals little or no evidence of strike-slip displacements along these lineaments.

Hoppin, R. A.↗

Fracture and Stress Evolution on Europa: New Insights Into Fracture Interpretation and Ice Thickness Estimates Using Fracture Mechanics Analyses

The work completed during the funding period has provided many important insights into fracturing behavior in Europa's ice shell. It has been determined that fracturing through time is likely to have been controlled by the effects of nonsynchronous rotation stresses and that as much as 720 deg of said rotation may have occurred during the visible geologic history. It has been determined that there are at least two distinct styles of strike-slip faulting and that their mutual evolutionary styles are likely to have been different, with one involving a significant dilational component during shear motion. It has been determined that secondary fracturing in perturbed stress fields adjacent to older structures such as faults is a prevalent process on Europa. It has been determined that cycloidal ridges are likely to experience shear stresses along the existing segment portions as they propagate, which affects propagation direction and ultimately induces tailcracking at the segment tip than then initiates a new cycle of cycloid segment growth. Finally, it has been established that mechanical methods (e.g., flexure analysis) can be used to determine the elastic thickness of the ice shell, which, although probably only several km thick, is likely to be spatially variable, being thinner under bands but thicker under ridged plains terrain.

Kattenhorn, Simon↗

The performance of suppressed carrier receivers in a pulsed RFI environment

This paper investigates the tracking performance of a Costas loop in the presence of single and multiple in-band pulsed RFI signals and receiver additive noise. It is shown that the loop's tracking performance is very sensitive to the pulse durations of the RFI signals, as well as their repetition rates and peak powers relative to those of the desired signal. The presence of in-band RFI can affect the loop's tracking performance in basically three ways. 1) The loop tracks the composite phase of the RFI instead of the phase of the desired signal when the effective RFI power is greater than that of the signal. 2) When the effective RFI power is not sufficiently large to capture the loop, there still will exist static phase error biases which cause the loop to lock at a phase between that of the desired signal and the composite RFI. 3) There is an increase in the rms phase jitter over the nominal design. These latter two effects degrade the bit error probability performance of the receiver. More significantly, if the nominal loop bandwidth is not designed properly to account for the increase in jitter phenomenon, frequency cycle slipping may result.

Simon, M. K.↗