Search NASA⌕ Search

SEARCH · Search NASA

Results for “SMACs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

68 records · Page 4

NASA Advanced Explorations Systems: Advancements in Life Support Systems

The NASA Advanced Exploration Systems (AES) Life Support Systems (LSS) project strives to develop reliable, energy-efficient, and low-mass spacecraft systems to provide environmental control and life support systems (ECLSS) critical to enabling long duration human missions beyond low Earth orbit (LEO). Highly reliable, closed-loop life support systems are among the capabilities required for the longer duration human space exploration missions assessed by NASA's Habitability Architecture Team (HAT). The LSS project is focused on four areas: architecture and systems engineering for life support systems, environmental monitoring, air revitalization, and wastewater processing and water management. Starting with the international space station (ISS) LSS systems as a point of departure (where applicable), the mission of the LSS project is three-fold: 1. Address discrete LSS technology gaps 2. Improve the reliability of LSS systems 3. Advance LSS systems towards integrated testing on the ISS. This paper summarized the work being done in the four areas listed above to meet these objectives. Details will be given on the following focus areas: Systems Engineering and Architecture- With so many complex systems comprising life support in space, it is important to understand the overall system requirements to define life support system architectures for different space mission classes, ensure that all the components integrate well together and verify that testing is as representative of destination environments as possible. Environmental Monitoring- In an enclosed spacecraft that is constantly operating complex machinery for its own basic functionality as well as science experiments and technology demonstrations, it's possible for the environment to become compromised. While current environmental monitors aboard the ISS will alert crew members and mission control if there is an emergency, long-duration environmental monitoring cannot be done in-orbit as current methodologies rely largely on sending environmental samples back to Earth. The LSS project is developing onboard analysis capabilities that will replace the need to return air and water samples from space for ground analysis. Air Revitalization- The air revitalization task is comprised of work in carbon dioxide removal, oxygen generation and recovery and trace contamination and particulate control. The CO2 Removal and associated air drying development efforts under the LSS project are focused both on improving the current SOA technology on the ISS and assessing and examining the viability of other sorbents and technologies available in academia and industry. The Oxygen Generation and Recovery technology development area encompasses several sub-tasks in an effort to supply O2 to the crew at the required conditions, to recover O2 from metabolic CO2, and to recycle recovered O2 back to the cabin environment. Current state-of-the-art oxygen generation systems aboard space station are capable of generating or recovering approximately 40% of required oxygen; for exploration missions this percentage needs to be greatly increased. A spacecraft cabin trace contaminant and particulate control system serves to keep the environment below the spacecraft maximum allowable concentration (SMAC) for chemicals and particulates. Both passive (filters) and active (scrubbers) methods contribute to the overall TC & PC design. Work in the area of trace contamination and particulate control under the LSS project is focused on making improvements to the SOA TC & PC systems on ISS to improve performance and reduce consumables. Wastewater Processing and Water Management- A major goal of the LSS project is the development of water recovery systems to support long duration human exploration beyond LEO. Current space station wastewater processing and water management systems distill urine and wastewater to recover water from urine and humidity condensate in the spacecraft at a approximately 74% recovery rate. For longer, farther missions into deep space, that recovery rate must be greatly increased so that astronauts can journey for months without resupply cargo ships from Earth.

Shull, Sarah A.↗

Effects of Acute Exposures to Carbon Dioxide upon Cognitive Functions

Carbon dioxide (CO2) originates from human metabolism and typically remains about 10-fold higher in concentration on the International Space Station (ISS) than at the earth's surface. There have been recurring complaints by crew members of episodes of "mental viscosity" adversely affecting their performance, and there is evidence from the ISS that associates CO2 levels with reports of headaches by crewmembers. Consequently, flight rules have been employed to control CO2 below 3 mm Hg, which is well below the existing Spacecraft Maximum Allowable Concentration (SMAC) of 10 mm Hg for 24-hour exposures, and 5.3 mm Hg for exposures of 7 to 180 days. Headaches, while sometime debilitating themselves, are also symptoms that can provide evidence that physiological defense mechanisms have been breached, and there is evidence that CO2 has effects at levels below the threshold for headaches. This concern appears to be substantiated in reports that CO2 at concentrations below 2 mm Hg substantially reduced some cognitive functions that are associated with the ability to make complex decisions in conditions that are characterized by volatility, uncertainty, complexity, ambiguity, and delayed feedback. These are conditions that could be encountered by crews in off-nominal situations or during the first missions beyond low earth orbit. Therefore, we set out to determine if decision-making under volatile, uncertain, confusing and ambiguous circumstances, where feedback is delayed or absent, is correlated with low levels of CO2 during acute exposures (several hours) in crew-like subjects and to determine if additional cognitive domains are sensitive to concentrations of CO2 at, or below, current ISS levels by using a test battery that is currently available onboard ISS. We enrolled 22 volunteers (8 females, 14 males) between the ages of 30-55 (38.8 +/- 7.0) years whose training and professional experience reflect that of the astronaut corps. Subjects were divided among 4 study groups. Exposures occurred in the 20-foot environmental chamber in Bldg 7 at JSC. Each group was exposed to each of four concentrations of CO2 (600, 1200, 2500, and 5000 ppm), and the exposure order was balanced across the groups which were randomly assigned to 4 possible complete exposure orders. Study participants and investigators were blinded to the exposure order. Each exposure lasted 4 hours and occurred on the same day each week for 4 consecutive weeks. Testing included the Strategic Management Simulation (SMS) methodology and the Cognition battery of psychometric measures that are being utilized aboard the ISS. Subjects participated in a familiarization session one week prior to the start of exposure sessions. Each exposure session followed the schedule noted in Figure 1 below. On the morning of each exposure, subjects completed the Cognition battery in a conference room at indoor ambient CO2 levels. Subjects then entered the exposure chamber and were acclimated to the environment for 15 minutes before completing another round of the Cognition battery. After a 20 minute rest, subject completed the approx.80 minute SMS. Subjects were allowed another 20 minute rest period before completing the final Cognition test battery in the exposure chamber. Subjects then returned to the conference room where they completed one final round of Cognition. Data from both testing methodologies are currently being analyzed and will be presented. Study investigators have not yet been unblinded to the coded exposure concentrations, but preliminary results suggest differences.

Ryder, V. E.↗

Trace Contaminant Control for the International Space Station's Node 1- Analysis, Design, and Verification

Trace chemical contaminant generation inside crewed spacecraft cabins is a technical and medical problem that must be continuously evaluated. Although passive control through materials selection and active control by adsorption and catalytic oxidation devices is employed during normal operations of a spacecraft, contaminant buildup can still become a problem. Buildup is particularly troublesome during the stages between the final closure of a spacecraft during ground processing and the time that a crewmember enters for the first time during the mission. Typically, the elapsed time between preflight closure and first entry on orbit for spacecraft such as Spacelab modules was 30 days. During that time, the active contamination control systems are not activated and contaminants can potentially build up to levels which exceed the spacecraft maximum allowable concentrations (SMACs) specified by NASA toxicology experts. To prevent excessively high contamination levels at crew entry, the Spacelab active contamination control system was operated for 53 hours just before launch.

Perry, J. L.↗

Polarimetric Remote Sensing of Atmospheric Aerosols: Instruments, Methodologies, Results, and Perspectives

Polarimetry is one of the most promising types of remote sensing for improved characterization of atmospheric aerosol. Indeed, aerosol particles constitute a highly variable atmospheric component characterized by a large number of parameters describing particle sizes, morphologies (including shape and internal structure), absorption and scattering properties, amounts, horizontal and vertical distribution, etc. Reliable monitoring of all these parameters is very challenging, and therefore the aerosol effects on climate and environment are considered to be among the most uncertain factors in climate and environmental research. In this regard, observations that provide both the angular distribution of the scattered atmospheric radiation as well as its polarization state at multiple wavelengths covering the UV–SWIR spectral range carry substantial implicit information on the atmospheric composition. Therefore, high expectations in improving aerosol characterization are associated with detailed passive photopolarimetric observations. The critical need to use space-borne polarimetry for global accurate monitoring of detailed aerosol properties was first articulated in the late 1980s and early 1990s. By now, several orbital instruments have already provided polarization observations from space, and a number of advanced missions are scheduled for launch in the coming years by international and national space agencies. The first and most extensive record of polarimetric imagery was provided by POLDER-I, POLDER-II, and POLDER/PARASOL multi-angle multi-spectral polarization sensors. Polarimetric observations with the POLDER-like design intended for collecting extensive multi-angular multi-spectral measurements will be provided by several instruments, such as the MAI/TG-2, CAPI/TanSat, and DPC/GF-5 sensors recently launched by the Chinese Space Agency. Instruments such as the 3MI/MetOp-SG, MAIA, SpexOne and HARP2 on PACE, POSP, SMAC, PCF, DPC–Lidar, ScanPol and MSIP/Aerosol-UA, MAP/Copernicus CO2 Monitoring, etc. are planned to be launched by different space agencies in the coming decade. The concepts of these future instruments, their technical designs, and the accompanying algorithm development have been tested intensively and analyzed using diverse airborne prototypes. Certain polarimetric capabilities have also been implemented in such satellite sensors as GOME-2/MetOp and SGLI/GCOM-C.

Aerosols↗

Spaceflight Maximum Allowable Concentrations for Ethyl Acetate

Ethyl acetate is a simple organic compound that occurs naturally and is used industrially as a solvent. It has been detected in the ISS atmosphere and is known to off-gas from building materials. As NASA astronauts have been and will be exposed to ethyl acetate during space missions, Spaceflight Maximum Allowable Concentrations (SMACs) were developed following an extensive review of the available literature.

E Spencer Williams↗

Source Contaminant Control System Design, Operation, and Testing for the Trash Compaction and Processing System

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). This process involves heating the trash to high temperatures, which in turn releases gaseous contaminants. Effluent management scenarios involve releasing these gases back to the ISS cabin after processing and/or directly venting these gases out to space via the Vacuum Exhaust System (VES). Concerns for recovering the gases back to cabin are crew health, safety, and spacecraft environmental impact. The Heat Melt Compactor (HMC) at NASA Ames Research Center (ARC) serves as a test system that supports TCPS development by conducting risk reduction activities associated with an ISS flight demonstration. Previous gas effluent studies were conducted on the HMC. The results consisted of contaminants from the trash exhaust to exceed Spacecraft Maximum Allowable Concentrations (SMAC), which are selected airborne contaminants that can elicit toxicity symptoms to crewmembers via exposure. The Source Contaminant Control System (SCCS) aims to reduce that risk by converting the contaminants into carbon dioxide (CO2) and water (H2O) vapor. The SCCS is composed of a carbon adsorbent bed, to avoid catalyst poisoning, and a catalytic oxidizer (CatOx), which promotes oxidation of the contaminants to CO2 and H2O. In turn, the gases coming out of the SCCS should be compatible to the ISS cabin and systems such as the Trace Contaminant Control System (TCCS). Preparation for SCCS testing alongside the HMC Gen 3 are currently underway at ARC. The main objectives are to evaluate CatOx efficiency by CO2 conversion and characterize effectiveness of removal by comparing contaminant results before and after CatOx. This paper will report on the SCCS design, operation, and testing with results.

Janine Young↗

Effects of Spaceflight Relevant Carbon Dioxide Levels on Pathogenesis Related Microbial Characteristics

BACKGROUND Multiple stressors in the spaceflight environment have the potential to alter microbial pathogenesis and virulence characteristics, including microgravity, radiation, and hostile/confined conditions. This combination of factors may lead to a stacking of risks, potentially creating unexpected increase in the risk of infectious disease. One understudied variable is the higher CO2 atmospheric concentration. The current Spaceflight Maximum Allowance Concentration (SMAC) for 24-hour average CO2 is 0.4% (3 mm Hg). These elevated ambient CO2 levels aboard the ISS could potentially influence the diversity and phenotypic responses of the resident microbial communities from both the spacecraft environment (air, surface, water) and crewmembers (gut, nasal, skin microbiomes). METHODS For these studies, we will evaluate the response of Staphylococcus aureus, Streptococcus pneumoniae and Enterobacter aerogenes, which are opportunistic pathogens that are of medical significance and have been or are likely to be found aboard spacecraft. These microorganisms will be cultured in both spaceflight analog and control conditions at CO2levels representing terrestrial atmospheric concentration of 0.04% (0.3 mmHg), ISS elevated concentration of 0.4% (3 mm Hg), and an unexpected elevated concentration of 1 % (7.6 mmHg) to represent a worst case scenario. DISCUSSION Overwhelming evidence from studies performed in food microbiology, marine biology and terrestrial environmental biology suggest altered gene expression, selective bacterial inhibition, increased growth and diversity, and increased antibiotic resistance of bacterial communities individually and in biofilm formation when exposed to increased levels of CO2. While many of these findings are based on levels of CO2 higher than would be found during spaceflight exploration missions, the potential for subtle changes in CO2 levels to exacerbate infectious disease risks warrants an evaluation of pathogen responses to spaceflight CO2 conditions. Our study will provide answers to spaceflight relevant atmospheric conditions, as described in the Risk of Adverse Health Effects Due to Host-Microorganism Interaction (GapMicro 103).

A A Medina-Colorado↗

Development of a Photoacoustic Formaldehyde Monitor

Key indoor air quality pollutant formaldehyde (H2CO) is tracked on International Space Station (ISS) using passive badges returned to the ground periodically for analysis. The process is time-consuming both in preparation and for analysis upon return 6-12 months later. Badges also require precious crew time for deploy, retrieval and stow. As NASA’s focus in space exploration shifts to the Moon and Mars, archival sample return becomes increasingly impractical, so the aim of this project is to develop a highly reliable real-time analyzer for H2CO at low concentrations with data downlinked. Potential sources of H2CO include materials off gassing, use of formalin as a tissue fixative in biological payloads and overheating of acetal polymers. The Spacecraft Maximum Allowable Concentration (SMAC) for H2CO is 100 ppb for exposures of 7 days or longer. ISS concentrations recently run only 10 - 30 ppb but have spiked as high as 60 ppb in the past. Gateway real time monitoring requirements call for a range of 8 - 140 ppb. For this project, a concentration range of 5 - 500 ppb H2CO is targeted. The core tunable diode laser spectroscopy (TDLS) technology was developed by Vista Photonics through the NASA and US Navy Small Business Innovation Research (SBIR) programs. Monitors based on this technology have been demonstrated on ISS, trialed on a nuclear submarine and are in production as Anomaly Gas Analyzers for both ISS and Orion. Initially, direct absorption TDLS was used exclusively in these monitors, however, the H2CO target concentration is much lower, and a longer wavelength required, so a photoacoustic spectroscopy (PAS) technique was adapted, where the laser excitation is detected by a sensitive microphone vs. a conventional photodetector. This paper will discuss the results of NASA-JSC laboratory testing of a prototype PAS based formaldehyde monitor and explore potential adaptations for Gateway missions and beyond.

Paul D Mudgett↗

Source Contaminant Control System Design, Operation, and Testing for the Trash Compaction and Processing System

The Trash Compaction and Processing System (TCPS) aims to reduce volume, biologically safen, physically stabilize, manage effluents, and recover resources from astronaut trash in the International Space Station (ISS). This process involves heating the trash to high temperatures, which in turn releases gaseous contaminants. Effluent management scenarios involve releasing these gases back to the ISS cabin after processing and/or directly venting these gases out to space via the Vacuum Exhaust System (VES). Concerns for recovering the gases back to cabin are crew health, safety, and spacecraft environmental impact. The Heat Melt Compactor (HMC) at NASA Ames Research Center (ARC) serves as a test system that supports TCPS development by conducting risk reduction activities associated with an ISS flight demonstration. Previous gas effluent studies were conducted on the HMC. The results consisted of contaminants from the trash exhaust to exceed Spacecraft Maximum Allowable Concentrations (SMAC), which are selected airborne contaminants that can elicit toxicity symptoms to crewmembers via exposure. The Source Contaminant Control System (SCCS) aims to reduce that risk by converting the contaminants into carbon dioxide (CO2) and water (H2O) vapor. The SCCS is composed of a carbon adsorbent bed, to avoid catalyst poisoning, and a catalytic oxidizer (CatOx), which promotes oxidation of the contaminants to CO2and H2O. In turn, the gases coming out of the SCCS should be compatible to the ISS cabin and systems such as the Trace Contaminant Control System (TCCS). Preparation for SCCS testing alongside the HMC Gen 3 are currently underway at ARC. The main objectives are to evaluate CatOx efficiency by CO2conversion and characterize effectiveness of removal by comparing contaminant results before and after CatOx. This paper will report on the SCCS design, operation, and testing with results.

TCPS↗

The Air Quality Monitor “Benzene” Anomaly: Ground Testing and On-going Effects

The International Space Station (ISS) Air Quality Monitors (AQMs) have provided targeted in-flight analysis of volatile organic compounds (VOCs) in the ISS atmosphere since early 2013. During their initial half decade of use covering multiple sets of units, the AQMs performed well, meeting their validation criteria and showing excellent accuracy compared to archival samples. In addition to routine environmental monitoring, the AQMs have also been used during a number of contingency situations and investigations related to Environmental Control and Life Support Systems (ECLSS). These include a potential ammonia leak, increases in atmospheric ethanol, and efforts to locate potential sources of polydimethylsiloxanes that lead to the production of dimethylsilanediol (DMSD) in the US Water Processor Assembly (WPA). As the fleet of AQMs has aged, several issues have arisen. These have ranged from pervasive problems on electronics boards to loss of sensitivity due to operating in an elevated CO2 environment. The most notable issue encountered during on-orbit operations was incorrect identification of compounds. This initially occurred in mid-2020, when AQM1 reported the presence of benzene. While the AQM team questioned the validity of these results, the concentration of the “benzene” continued to increase and eventually exceeded the 30- and 180-day Spacecraft Maximum Allowable Concentration (SMAC). This led to wide-ranging efforts by a number of groups aimed at understanding the situation and identifying the source of the “benzene.” AQM1 failed after being relocated to the Russian Segment as part of the investigation, and the unit was returned for evaluation. When archive samples collected while the AQM was measuring elevated benzene showed no detectable benzene, the focus of the investigation shifted to determining the cause of the false positive readings. Here, we will discuss the results of this investigation by the AQM team, potential causes of the interference, and subsequent reporting of AQM1 results.

W T Wallace↗

Development of a Photoacoustic Formaldehyde Monitor

Key indoor air quality pollutant formaldehyde (H 2 CO) is tracked on International Space Station (ISS) using passive badges returned to the ground periodically for analysis. The process is time-consuming both in preparation and for analysis upon return 6-12 months later. Badges also require precious crew time for deploy, retrieval and stow. As NASA’s focus in space exploration shifts to the Moon and Mars, archival sample return becomes increasingly impractical, so the aim of this project is to develop a highly reliable real-time analyzer for H 2 CO at low concentrations with data downlinked. Potential sources of H 2 CO include materials off gassing, use of formalin as a tissue fixative in biological payloads and overheating of acetal polymers. The Spacecraft Maximum Allowable Concentration (SMAC) for H 2 CO in air is 100 ppb for exposures of 7 days or longer. ISS concentrations of H 2 CO are running only 10 - 30 ppb in the recent several years but have spiked as high as 60 ppb. Gateway real time monitoring requirements for H 2 CO call for a range of 8 - 138 ppb. For this project, a concentration range of 5 - 500 ppb H 2 CO is targeted. The core tunable diode laser spectroscopy (TDLS) technology used for this project was developed by Vista Photonics through the NASA and US Navy Small Business Innovation Research (SBIR) programs. Monitors based on TDLS have been demonstrated on ISS, trialed on a nuclear submarine and are being certified as portable Anomaly Gas Analyzers (AGA) for both ISS and Orion. Initially, direct absorption TDLS was used exclusively in these devices. The H 2 CO target concentration, however, is low ppb, and a longer wavelength is required, so a photoacoustic spectroscopy (PAS) technique was adapted, where the laser excitation is detected by a sensitive microphone vs. a conventional photodetector. This paper will discuss the results of NASA-JSC laboratory testing of a prototype PAS based formaldehyde in air monitor and briefly discuss next steps.

Photoacoustic Formaldehyde Monitor↗

The Air Quality Monitor “Benzene” Anomaly: Ground Testing and On-going Effects

The International Space Station (ISS) Air Quality Monitors (AQMs) have provided targeted in-flight analysis of volatile organic compounds (VOCs) in the ISS atmosphere since early 2013. During their initial half decade of use covering multiple sets of units, the AQMs performed well, meeting their validation criteria and showing excellent accuracy compared to archival samples. In addition to routine environmental monitoring, the AQMs have also been used during a number of contingency situations and investigations related to Environmental Control and Life Support Systems (ECLSS). These include a potential ammonia leak, increases in atmospheric ethanol, and efforts to locate potential sources of polydimethylsiloxanes that lead to the production of dimethylsilanediol (DMSD) in the US Water Processor Assembly (WPA). As the fleet of AQMs has aged, several issues have arisen. These have ranged from pervasive problems on electronics boards to loss of sensitivity due to operating in an elevated CO2 environment. The most notable issue encountered during on-orbit operations was incorrect identification of compounds. This initially occurred in mid-2020, when AQM1 reported the presence of benzene. While the AQM team questioned the validity of these results, the concentration of the “benzene” continued to increase and eventually exceeded the 30- and 180-day Spacecraft Maximum Allowable Concentration (SMAC). This led to wide-ranging efforts by a number of groups aimed at understanding the situation and identifying the source of the “benzene.” AQM1 failed after being relocated to the Russian Segment as part of the investigation, and the unit was returned for evaluation. When archive samples collected while the AQM was measuring elevated benzene showed no detectable benzene, the focus of the investigation shifted to determining the cause of the false positive readings. Here, we will discuss the results of this investigation by the AQM team, potential causes of the interference, and subsequent reporting of AQM1 results.

W T Wallace↗

High Risk Spacecraft Materials Offgassing

NASA-STD-6001B, Determination of Offgassed Products (Test 7), provides the offgassing characteristics under standardized conditions for materials and assembled articles to be located within habitable spacecraft environments. Experience with Test 7 has found certain material types to be of higher risk for offgassing undesirable compounds aboard spacecraft than others. Formaldehyde and acrolein are historically high T value offgassed components of the offgassed compound target list because they have low spacecraft maximum allowable concentration (SMAC) values assigned by the JSC Toxicology Group. Carbon disulfide, benzene, acrylonitrile, and furan are additional target compounds of concern due to their lower thresholds of toxicity as determined by the JSC Toxicology Group. Materials offgassing siloxanes are also of concern due to their degradation effects on environmental control and life support system (ECLSS) components and performance. Spacecraft materials and articles defined in this manuscript as high risk were identified after examining and condensing data for these compounds of concern from approximately 3000 tests performed over 30 years. Summaries of high risk material and article types based on highest Multi-Purpose Crew Vehicle (MPCV) T values are also presented. Historical analysis shows high risk components are produced largely from test materials and articles in the general categories of electronic/powered components, foams, paints/coatings/films, adhesives/tapes, epoxy/resins, liquids/gels, Nomex® with surface treatments, markers/pens/inks, dry film lubricants, thermoplastics, hygiene items (deodorants, lip balms), and silicone rubber. These data are intended to be a resource for spacecraft materials and processes managers, designers, and toxicologists. High risk materials and articles intended for use aboard spacecraft should be tested in accordance with NASA-STD-6001B Test 7.

Vanessa D Buchanan↗

The Air Quality Monitor “Benzene” Anomaly: Ground Testing and On-going Effects

The International Space Station (ISS) Air Quality Monitors (AQMs) have provided targeted in-flight analysis of volatile organic compounds (VOCs) in the ISS atmosphere since early 2013. During their initial half decade of use covering multiple sets of units, the AQMs performed well, meeting their validation criteria and showing excellent accuracy compared to archival samples. In addition to routine environmental monitoring, the AQMs have also been used during a number of contingency situations and investigations related to Environmental Control and Life Support Systems (ECLSS). These include a potential ammonia leak, increases in atmospheric ethanol, and efforts to locate potential sources of polydimethylsiloxanes that lead to the production of dimethylsilanediol (DMSD) in the US Water Processor Assembly (WPA). As the fleet of AQMs has aged, several issues have arisen. These have ranged from pervasive problems on electronics boards to loss of sensitivity due to operating in an elevated CO2 environment. The most notable issue encountered during on-orbit operations was incorrect identification of compounds. This initially occurred in mid-2020, when AQM1 reported the presence of benzene. While the AQM team questioned the validity of these results, the concentration of the “benzene” continued to increase and eventually exceeded the 30- and 180-day Spacecraft Maximum Allowable Concentration (SMAC). This led to wide-ranging efforts by a number of groups aimed at understanding the situation and identifying the source of the “benzene.” AQM1 failed after being relocated to the Russian Segment as part of the investigation, and the unit was returned for evaluation. When archive samples collected while the AQM was measuring elevated benzene showed no detectable benzene, the focus of the investigation shifted to determining the cause of the false positive readings. Here, we will discuss the results of this investigation by the AQM team, potential causes of the interference, and subsequent reporting of AQM1 results.

William T Wallace↗