Search NASA⌕ Search

SEARCH · Search NASA

Results for “SMILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Novel covariance-based neutrality test of time-series data reveals asymmetries in ecological and economic systems

Systems as diverse as the interacting species in a community, alleles at a genetic locus, and companies in a market are characterized by competition (over resources, space, capital, etc) and adaptation. Neutral theory, built around the hypothesis that individual performance is independent of group membership, has found utility across the disciplines of ecology, population genetics, and economics, both because of the success of the neutral hypothesis in predicting system properties and because deviations from these predictions provide information about the underlying dynamics. However, most tests of neutrality are weak, based on static system properties such as species-abundance distributions or the number of singletons in a sample. Time-series data provide a window onto a system’s dynamics, and should furnish tests of the neutral hypothesis that are more powerful to detect deviations from neutrality and more informative about to the type of competitive asymmetry that drives the deviation. Here, we present a neutrality test for time-series data. We apply this test to several microbial time-series and financial time-series and find that most of these systems are not neutral. Our test isolates the covariance structure of neutral competition, thus facilitating further exploration of the nature of asymmetry in the covariance structure of competitive systems. Much like neutrality tests from population genetics that use relative abundance distributions have enabled researchers to scan entire genomes for genes under selection, we anticipate our time-series test will be useful for quick significance tests of neutrality across a range of ecological, economic, and sociological systems for which time-series data are available. Here, future work can use our test to categorize and compare the dynamic fingerprints of particular competitive asymmetries (frequency dependence, volatility smiles, etc) to improve forecasting and management of complex adaptive systems.

59 BASIC BIOLOGICAL SCIENCES↗

Hermalinda Coronado: Bringing kindness to every interaction

Of the more than 400 employees who find themselves in and out of the RLUOB building at TA-55 on any given day, there is one person that almost everyone knows, and that’s Hermalinda Coronado. Hermalinda is on the janitorial staff for both RLUOB and areas behind the fence near PF-4. She’s known for always wearing a smile and doing her work with excellence and integrity.

99 GENERAL AND MISCELLANEOUS↗

'I’m here because I want to make a difference.’

If you're at Los Alamos National Laboratory and happen to encounter Matt Johnson, don't be surprised if this busy leader smiles and stops to ask you how he can help. That’s the essence of the type of manager—and person—he is. As the leader of the Pit Technologies division at the Lab, Matt oversees six groups that cover national security manufacturing, operations and professional support. Matt started his career at the Lab in 2002. His first assignments included work with confinement vessels used at firing sites such as Nevada National Security Site. Matt's deep knowledge of high-strength steel made him a perfect fit for the research and fabrication of these explosive-proof containers. Shortly after joining the Lab, Matt accepted the position as the Welding and Joining team leader supporting national security manufacturing, the hydrotest program and welding efforts across the NNSA complex. Over time, Matt made his way across many programs at the Laboratory.

99 GENERAL AND MISCELLANEOUS↗

Finch: Toxicity Dose Response Curve Prediction of Chemical Compounds and Mixtures

A paradigm shift in chemical risk assessment is emphasizing mixture testing over single compound analysis, eliminating animal testing, and adopting advanced modeling approaches to understand mixture activity profiles. However, existing computational models largely focus on single chemicals, with few effective solutions for modeling complex mixtures that account for synergistic or antagonistic effects and multiple Modes of Action (MoA). Conventional methods like concentration addition (CA) and independent action (IA) are insufficient for this task as they are designed for simplistic interactions and struggle to account for the dynamic and multifaceted nature of chemical mixtures, such as overlapping MoA and non-linear interactions. Finch offers a novel approach utilizing deep learning (DL) embeddings and multi-task quantitative structure-activity relationship (QSAR) models to improve chemical exposure prediction. By leveraging molecular descriptors, physiochemical properties, and large language model (LLM) embeddings from SMILES inputs, Finch preserves critical information in a latent space thereby enhancing predictive accuracy. The multi-task learning aspect of Finch is highly advantageous, as it simultaneously optimizes multiple loss functions, leveraging all available data across tasks to develop generalized representations that effectively capture complex ingredient interactions within mixtures.

59 BASIC BIOLOGICAL SCIENCES↗

Characteristics of the HYDICE sensor

In 1992, in an effort to significantly improve knowledge in the field of hyperspectral imagery, the Naval Research Laboratories defined a set of requirements for a new generation sensor. Construction of this instrument, designated HYDICE, has recently been completed at Hughes Danbury Optical Systems. It is currently being flight tested on a Convair 580 operated by ERIM. This paper reports on some of the performance parameters measured to date. The majority of these are derived from laboratory test data. Optomechanical parameters include MTF, spatial co-registration, 'smile', spectral profile and spectral calibration. Detector-related parameters include system responsivity, signal to noise ratio, radiometric stability and gain linearity. The results are compared with the original system performance predictions.

Basedow, R. W.↗

High Accuracy In-Flight Wavelength Calibration of Imaging Spectrometry Data

Accurate wavelength calibration of imaging spectrometer data is essential if proper atmospheric transmission corrections are to be made to obtain apparent surface reflectance. Accuracies of 0.1 nm are necessary for a 10 nm-sampling instrument in order to match the slopes of the deep atmospheric water vapor features that dominate the 0.7-2.3 micrometer regions. The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is calibrated in the laboratory to determine the wavelength position and full-width-half-maximum (FWHM) response for each of the 224 channels. The accuracies are limited by the quality of the monochromator used as a source. The accuracies vary from plus or minus to plus or minus 1.5 nm depending on the wavelength region, in general decreasing with increasing wavelength. Green et al. make corrections to the wavelength calibrations by using the known positions of 14 atmospheric absorption features throughout the 0.4-2.5 micrometer wavelength region. These features, having varying width and intensity, were matched to the MODTRAN model with a non-linear least squares fitting algorithm. A complete calibration was developed for all 224 channels by interpolation. Instrument calibration cannot be assumed to be stable to 0.1 nm over a flight season given the rigors of thermal cycling and launch and landing loads. The upcoming sensor HYDICE will require a means for in-flight spectral calibration of each scene because the calibration is both temperature and pressure sensitive. In addition, any sensor using a two-dimensional array has the potential for systematic wavelength shifts as a function of cross-track position, commonly called 'smile'. Therefore, a rapid means for calibrating complete images will be required. The following describes a method for determining instrument wavelength calibration using atmospheric absorption features that is efficient enough to be used for entire images on workstations. This study shows the effect of the surface reflectance on the calibration accuracy and the calibration history for the AVIRIS B spectrometer over the 1992 flight season.

Goetz, Alexander F. H.↗

Dressing Down

Smiles and laughter reduce stress. They also renew energy and trust in ourselves and others. A characteristic of any good project manager is his or her willingness to challenge the conventional way of doing things. Use whatever tools you have available, including a sense of humor. Do you have examples of how you learned from experience, especially examples that challenged the status quo?

Schabes, Harvey↗

New Method for Calibration for Hyperspectral Pushbroom Imaging Systems

A new, easy-to-implement approach for achieving highly accurate spectral and radiometric calibration of array-based, hyperspectral pushbroom imagers is presented in this paper. The equivalence of the plane of the exit port of an integrating sphere to a Lambertian surface is utilized to provide a field-filling radiance source for the imager. Several different continuous wave lasers of various wavelengths and a quartz-tungsten-halogen lamp internally illuminate the sphere. The imager is positioned to "stare" into the port, and the resultant data cube is analyzed to determine wavelength calibrations, spectral widths of channels, radiometric characteristics, and signal-to-noise ratio, as well as an estimate of signal-to-noise performance in the field. The "smile" (geometric distortion of spectra) of the system can be quickly ascertained using this method. As the price and availability of solid state laser sources improve, this technique could gain wide acceptance.

Ryan, Robert↗

Working at the Ohio Aerospace Institute

The Ohio Aerospace Institute is a wonderful place to work. I enjoy coming to work everyday knowing that I will be surrounded by smiling faces. My mentor, Mary Auzenne, is the Program Manager of the LERCIP College Internship Program, however, I spend most of my time working with Akua Soadwa, the Assistant Program Manager. She is in charge of planning, coordinating, and managing every event that is involved with the college internship program such as the socials, picnic, banquet, workshops, and research symposium. My job is to make her job easier. I help out with the planning, coordinating, and managing of these events. When I first got on board Akua was in the process of planning the second social for the interns. The social is a way for the interns to interact with one another as well as to find out more about where the other interns are working at NASA. We ordered the food, went shopping, and set up the Guerin House for the party. I made sign-in sheets, which helped us get a rough count of the attendees. The next event was the Technical Presentation Workshop and the Professional Development Workshop. These workshops are designed to enhance skills of the interns. We were there to sign people in and direct them to the room where the presentation was to take place. I also took pictures of the workshop and provided copies for the presenters, as well as our files.

Szabo, Hortenzia↗

ASK Magazine; No. 21

THIS ISSUE FEATURES A VISUAL DEPICTION OF THE ACADEMY of Program and Project Leadership (APPL). I imagine a variety of initial reactions to the drawing. One might be, "What is a cartoon doing in a magazine about project management?" Or perhaps, "Wow, nice colors-and fun." Another may be to closely search the image for signs, symbols and meaning. Still another, to read a new level of innovation and creativity into the picture. Undoubtedly, some readers will raise questions about the cost. Of course, any reaction is a sign of engagement. The stronger, the more energized the emotional and cognitive processing, the better. It is a sign of attention and interaction. For I've heard it said, "You only need to worry if they don t care one way or the other." So what is the point of the picture? To stimulate interest, raise questions, promote discussion, and maybe raise a smile.. .That, at least, was my initial reaction when I was introduced to the work of Nancy Hegedus, who helps to create these drawings for Root Learning Inc. At the NASA PM Conference, I was first shown the work Nancy had been doing with the help of Goddard s Knowledge Management Architect, Dr. Ed Rogers. I was immediately drawn into the power of visualization as a tool for more effective learning, communicating, and conveying complex knowledge concepts. We need new tools in today s world, where information and data overwhelms by sheer volume. There are articles, pamphlets, communications, and white papers-all aiming to convince and influence. Reactions to these tend to be either avoidance or mind-numbing, heavy-eyed consent; the message never registers or enters the soul. That s one of the reasons that APPL s Knowledge Sharing Initiative (KSI) has turned to storytelling as a memorable way of transfer- ring knowledge, inspiring imitation of best practices, and spurring reflection. ASK Magazine s recent fourth birthday marks an important milestone in APPL s continuing quest to provide ongoing support to project managers and to promote mission success. And similar to storytelling, the power of visualization is receiving increasing attention in recent years as a way to stimulate engagement. Pictures and visual graphs are viewed as one of the most effective ways for displaying, describing, and generating discussion about quantitative and technically complex information. Prototypes, models, and simulations are considered essential for stimulating innovation through open and engaging discussions. There has also been extensive writing on the use of visual graphics, pictures, and cartoons to facilitate memory, creativity, openness, attention-and even well-being. For many of these reasons, I am excited to have a colorful visual depiction of the APPL world included in ASK. Without the addition of text or slides, the intent is to invite people into the world of the APPL mission-as well as its products, services, customers, and partners- in a fun and engaging manner. As project leaders strive to find ways to encourage engagement, learning, and transmission of knowledge, traditional technologies are proving to be as valuable as modern technologies. (But for those who want more information in the form of texts and slide presentations, we certainly have an abundance of those as well.)

Laufer, Alexander↗

Initial On-Orbit Spatial Resolution Characterization of OrbView-3 Panchromatic Images

Characterization was conducted under the Memorandum of Understanding among Orbital Sciences Corp., ORBIMAGE, Inc., and NASA Applied Sciences Directorate. Acquired five OrbView-3 panchromatic images of the permanent Stennis Space Center edge targets painted on a concrete surface. Each image is available at two processing levels: Georaw and Basic. Georaw is an intermediate image in which individual pixels are aligned by a nominal shift in the along-scan direction to adjust for the staggered layout of the panchromatic detectors along the focal plane array. Georaw images are engineering data and are not delivered to customers. The Basic product includes a cubic interpolation to align the pixels better along the focal plane and to correct for sensor artifacts, such as smile and attitude smoothing. This product retains satellite geometry - no rectification is performed. Processing of the characterized images did not include image sharpening, which is applied by default to OrbView-3 image products delivered by ORBIMAGE to customers. Edge responses were extracted from images of tilted edges in two directions: along-scan and cross-scan. Each edge response was approximated with a superposition of three sigmoidal functions through a nonlinear least-squares curve-fitting. Line Spread Functions (LSF) were derived by differentiation of the analytical approximation. Modulation Transfer Functions (MTF) were obtained after applying the discrete Fourier transform to the LSF.

Blonski, Slawomir↗

Optical Design and Performance of the Ultra-Compact Imaging Spectrometer

We present the optical design and performance of the Ultra-Compact Imaging Spectrometer (UCIS) currently under development at Caltech's Jet Propulsion Laboratory. The new instrument demonstrates a low optical bench mass of less than 0.5 kg and compact size that enables Mars Rover or other in situ planetary applications. UCIS is a F/4, wide field (30deg) design, covering the spectral range 500-2600 nm and is enabled by a simple all aluminum two-mirror telescope and Offner spectrometer. We discuss here the optical design and alignment method that enables this compact and low mass imaging spectrometer and demonstrate successful spectrometer alignment with smile and keystone levels at 2-3% of a pixel width.

Imaging spectroscopy↗

The Hyperspectral Thermal Emission Spectrometer (HyTES): Preliminary Results

The Hyperspectral Thermal Emission Spectrometer (HyTES) is being developed as part of the risk reduction activities associated with the Hyperspectral Infrared Imager (HyspIRI). HyspIRI is one of the Tier 2 Decadal Survey Missions. HyTES will provide information on how to place the filters on the HyspIRI Thermal Infrared Instrument (TIR) as well as provide antecedent science data. The pushbroom design has 512 spatial pixels over a 50-degree field of view and 256 spectral channels between 7.5 micrometers to 12 micrometers. HyTES includes many key enabling state-of-the-art technologies including a high performance convex diffraction grating, a quantum well infrared photodetector (QWIP) focal plane array, and a compact Dyson-inspired optical design. The Dyson optical design allows for a very compact and optically fast system (F/1.6). It also minimizes cooling requirements due to the fact it has a single monolithic prism-like grating design which allows baffling for stray light suppression. The monolithic configuration eases mechanical tolerancing requirements which are a concern since the complete optical assembly is operated at cryogenic temperatures ((is) approximately 100K). The QWIP allows for optimum spatial and spectral uniformity and provides adequate responsivity or D-star to allow 200mK noise equivalent temperature difference (NEDT) operation across the LWIR passband. Assembly of the system is nearly complete. After completion, alignment results will be presented which show low keystone and smile distortion. This is required to minimize spatial-spectral mixing between adjacent spectral channels and spatial positions. Predictions show the system will have adequate signal to noise for laboratory calibration targets.

Moon Mineralogical Mapper (M3).↗

Long-Wave Infrared Dyson Spectrometer

Preliminary results are presented for an ultra compact long-wave infrared slit spectrometer based on the dyson concentric design. The dyson spectrometer has been integrated in a dewar environment with a quantum well infrared photodetecor (QWIP), concave electron beam fabricated diffraction grating and ultra precision slit. The entire system is cooled to cryogenic temperatures to maximize signal to noise ratio performance, hence eliminating thermal signal from transmissive elements and internal stray light. All of this is done while maintaining QWIP thermal control. A general description is given of the spectrometer, alignment technique and predicated performance. The spectrometer has been designed for optimal performance with respect to smile and keystone distortion. A spectral calibration is performed with NIST traceable targets. A 2-point non-uniformity correction is performed with a precision blackbody source to provide radiometric accuracy. Preliminary laboratory results show excellent agreement with modeled noise equivalent delta temperature and detector linearity over a broad temperature range.

imaging↗

Diurnal Variations of Stratospheric Ozone Measured by Ground-Based Microwave Remote Sensing at the Mauna Loa NDACC Site: Measurement Validation and GEOSCCM Model Comparison

There is presently renewed interest in diurnal variations of stratospheric and mesospheric ozone for the purpose of supporting homogenization of records of various ozone measurements that are limited by the technique employed to being made at certain times of day. We have made such measurements for 19 years using a passive microwave remote sensing technique at the Mauna Loa Observatory (MLO) in Hawaii, which is a primary station in the Network for Detection of Atmospheric Composition Change (NDACC). We have recently reprocessed these data with hourly time resolution to study diurnal variations. We inspected differences between pairs of the ozone spectra (e.g., day and night) from which the ozone profiles are derived to determine the extent to which they may be contaminated by diurnally varying systematic instrumental or measurement effects. These are small, and we have reduced them further by selecting data that meet certain criteria that we established. We have calculated differences between profiles measured at different times: morning-night, afternoon-night, and morning-afternoon and have intercompared these with like profiles derived from the Aura Microwave Limb Sounder (Aura-MLS), the Upper Atmosphere Research Satellite Microwave Limb Sounder (UARS-MLS),t he Superconducting Submillimeter-Wave Limb-Emission Sounder (SMILES), and Solar Backscatter Ultraviolet version 2 (SBUV2) measurements. Differences between averages of coincident profiles are typically less than 1.5 percent of typical nighttime values over most of the covered altitude range with some exceptions. We calculated averages of ozone values for each hour from the Mauna Loa microwave data, and normalized these to the average for the first hour after midnight for comparison with corresponding values calculated with the Goddard Earth Observing System Chemistry Climate Model (GEOSCCM). We found that the measurements and model output mostly agree to better than 1.5 percent of the midnight value, with one noteworthy exception: The measured morning-night values are significantly (2-3 percent) higher than the modeled ones from 3.2 to 1.8 hPa (approximately 39-43 km), and there is evidence that the measured values are increasing compared to the modeled values before sunrise in this region.

GEOSCCM model comparison↗

The Earth's Exosphere and Its Response to Space Weather

Neutral-Plasma charge exchange is a fundamental physical process that occurs ubiquitously across the universe. In geospace, charge exchange occurs in the Earth’s topside ionosphere, polar wind, plasmasphere, inner magnetosphere, and magnetosheath. Past and current space missions have profiled plasma and electromagnetic characteristics in various parts of the Earth’s magnetospheric system. However, observations of the exosphere, i.e., neutrals above 500 km altitude, are still sparse and, in some regions, non-existent, which limits our understanding of the neutral contribution to the overall dynamics of the geospace environment. Cold exospheric neutrals (< 10 eV) play an important role in the Sun-Earth interaction. Variability of exospheric density provides key information of the Earth’s atmospheric loss under dynamic space environment conditions. Various neutral species and their density variations in the polar wind can alter ion outflow patterns, modifying global magnetospheric dynamics. Exospheric neutrals also provide an energy sink for the inner magnetosphere by creating Energetic Neutral Atoms (ENAs) through charge exchange with high-energy ring current ions, which subsequently leave our geospace system unimpeded by magnetic fields. Exospheric neutrals also provide a means to observe the global interaction of the solar wind – magnetosphere, through global imaging of the system via ENAs (e.g., the TWINS and IMAGE missions) and soft X-rays (e.g., the upcoming LEXI and SMILE missions), the byproducts of neutral-plasma charge exchange. In the coming decade, we advocate that our community needs to increase our exploration of the neutral populations in the outermost reaches of the Earth’s atmosphere. It is imperative that we improve both in-situ and remote-sensing technologies for measuring key neutral species in our exosphere. We also encourage dedicated exosphere missions and to stimulate model developments of our exosphere and its interaction with the co-located magnetospheric system and neighboring Ionosphere - Thermosphere - Mesosphere system.

Hyunju Connor↗

Soft X-Ray Imaging of Earth's Dayside Magnetosheath and Cusps Using Hybrid Simulations

Interactions between solar wind ions and neutral hydrogen atoms in Earth's exosphere can lead to the emission of soft X-rays. Upcoming missions such as SMILE and LEXI aim to use soft X-ray imaging to study the global structure of the magnetosphere. Although the magnetosheath and dayside magnetopause can often be driven by kinetic physics, it has typically been omitted from fluid simulations used to predict X-ray emissions. We study the possible results of soft X-ray imaging using hybrid simulations under quasi-radial interplanetary magnetic fields, where ion-ion instabilities drive ultra-low frequency foreshock waves, leading to turbulence in the magnetosheath, affecting the dynamics of the cusp and magnetopause. We simulate soft X-ray emission to determine what may be seen by missions such as LEXI, and evaluate the possibility of identifying kinetic structures. While kinetic structures are visible in high-cadence imaging, current instruments may not have the time resolution to discern kinetic signals.

J Ng↗