Search NASASearch

SEARCH · Search NASA

Results for “SOLAR SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Spectral measurements by the filter method on Lewis' carbon arc solar simulators

There exists a problem in the measuring of the spectral irradiance of solar simulators. This difficulty has manifested intself in both monochromator and filter measurements. This report is the discussion of the measurements by Eppley Laboratory on the Lewis carbon arc solar Simulators, the further analysis of the method of filter radiometry made by Lewis personnel, and the comparison with the monochromator measurements. Previously when the filter technique was used it was assumed that the a priori knowledge of the source's spectral characteristics must be known. In this report it will be shown that for a carb0n arc source a knowledge of the source is not required after the filters have been properly chosen.

RADIOMETRY

Variation in spectral irradiance of the SES solar simulator

A test to determine the spectral characteristics of the solar simulation produced by the solar environment simulator (SES) comprised a statistical analysis to determine the spectral variance, and its effect on the average absorptivity of surface coatings.

Mcnutt, A. E.

Solar simulation testing of an earth satellite at Goddard Space Flight Center

The use of solar simulation to evaluate the thermal performance of a spacecraft is still relatively new and controversial. Reference 1 reports successful use of carbon arcs in testing the Telstar spacecraft. Additional information on the use of the carbon arc as a solar source should be useful in evaluating its effectiveness as a thermal design technique. At Goddard Space Flight Center carbon arcs have been used for achieving the solar simulation testing of spacecraft sized for the Delta and Scout boosters. This report presents data and experience from such testing, using the results from the flight backup Ariel II (UK-2/S-52) international satellite as an example.

ENVIRONMENTAL TESTING

Evaluation of flat-plate collector efficiency under controlled conditions in a solar simulator

The measured thermal efficiencies of 35 collectors tested with a solar simulator, along with the correlation equations used to generalize the data, are presented. The single correlation used is shown to apply to all the different types of collectors tested, including one with black paint and one cover, one with a selective surface coating and two covers, and an evacuated-tube collector. The test and correlation technique is also modified by using a shield so that collectors larger than the simulator test area can also be tested. This technique was verified experimentally for a shielded collector for which the collector shielded area was 31% of the solar simulator radiation area. A table lists all the collectors tested, the collector areas, and the experimental constants used to correlate the data for each collector.

Johnson, S. M.

Evaluation of flat-plate collector efficiency under controlled conditions in a solar simulator

The measured thermal efficiencies of 35 collectors tested with a solar simulator, along with the correlation equations used to generalize the data, are presented in this report. The single correlation used is shown to apply to all the different types of collectors tested, including one with black paint and one cover, one with a selective surface coating and two covers, and an evacuated-tube collector. The test and correlation technique is also modified by using a shield so that collectors larger than the simulator test area can also be tested. This technique was verified experimentally for a shielded collector for which the collector shielded area was 31% of the solar simulator radiation area. A table lists all the collectors tested, the collector areas, and the experimental constants used to correlate the data for each collector.

Johnson, S. M.

Design data package and operating procedures for MSFC solar simulator test facility

Design and operational data for the solar simulator test facility are reviewed. The primary goal of the facility is to evaluate the performance capacibility and worst case failure modes of collectors, which utilize either air or liquid transport media. The facility simulates environmental parameters such as solar radiation intensity, solar spectrum, collimation, uniformity, and solar attitude. The facility also simulates wind conditions of velocity and direction, solar system conditions imposed on the collector, collector fluid inlet temperature, and geometric factors of collector tilt and azimuth angles. Testing the simulator provides collector efficiency data, collector time constant, incident angle modifier data, and stagnation temperature values.

Source record

Low-cost, air mass 2 solar simulator

A low cost air mass 2 solar simulator for testing flat-plate solar collectors was developed and operated at Lewis. Total cost was less than $10,800/sq m ($1000/sq ft). It consists of an array of 143 tungsten-halogen 300-watt lamps, each having integral dichroic coated reflectors. A second array of 143 respective hexagonal-shaped plastic Fresnel lenses are located approximately 1 focal length from the lamps. The simulator will produce a uniform collimated beam covering an area of 1.2 by 1.2m(4 by 4 ft). Design features, construction details, and component costs are given, as well as measured results on a 12-lamp prototype.

Yass, K.

The Large Area Pulsed Solar Simulator (LAPSS)

The Large Area Pulsed Solar Simulator (LAPSS) has been installed at JPL. It is primarily intended to be used to illuminate and measure the electrical performance of photovoltaic devices. The simulator, originally manufactured by Spectrolab, Sylmar, CA, occupies an area measuring about 3 m wide x 12 m long. The data acquisition and data processing subsystems have been modernized. Tests on the LAPSS performance resulted in better than plus or minus 2 percent uniformity of irradiance at the test plane and better than plus or minus 0.3 percent measurement repeatability after warm-up. Glass absorption filters reduce the ultraviolet light emitted from the xenon flash lamps. This results in a close match to three different standard airmass zero and airmass 1.5 spectral irradiances. The 2-ms light pulse prevents heating of the device under test, resulting in more reliable temperature measurements. Overall, excellent electrical performance measurements have been made of many different types and sizes of photovoltaic devices. Since the original printing of this publication, in 1993, the LAPSS has been operational and new capabilities have been added. This revision includes a new section relating to the installation of a method to measure the I-V curve of a solar cell or array exhibiting a large effective capacitance. Another new section has been added relating to new capabilities for plotting single and multiple I-V curves, and for archiving the I-V data and test parameters. Finally, a section has been added regarding the data acquisition electronics calibration.

Mueller, R. L.

The Large Area Pulsed Solar Simulator (LAPSS)

A Large Area Pulsed Solar Simulator (LAPSS) has been installed at JPL. It is primarily intended to be used to illuminate and measure the electrical performance of photovoltaic devices. The simulator, originally manufactured by Spectrolab, Sylmar, California, occupies an area measuring about 3 meters wide by 12 meters long. The data acquisition and data processing subsystems have been modernized. Tests on the LAPSS performance resulted in better than +/- 2 percent uniformity of irradiance at the test plane and better than +/- 0.3 percent measurement repeatability after warm-up. Glass absorption filters are used to reduce the level of ultraviolet light emitted from the xenon flash lamps. This provides a close match to standard airmass zero and airmass 1.5 spectral irradiance distributions. The 2 millisecond light pulse prevents heating of the device under test, resulting in more reliable temperature measurements. Overall, excellent electrical performance measurements have been made of many different types and sizes of photovoltaic devices.

Mueller, R. L.

Design concepts to improve high performance solar simulator

By improving several important components of the well known off-axis solar simulator system, a considerable step forward was made. The careful mathematical studies on the optics and the thermal side of the problem lead to a highly efficient system with low operational costs and a high reliability. The actual performance of the simulator is significantly better than the specified one, and the efficiency is outstanding. No more than 12 lamps operating at 18 kW are required to obtain one Solar Constant in the 6 m beam. It is now known that by using sophisticated optics, even larger facilities of high performance can be designed without leaving the proven off-axis concept and using a spherical mirror. Using high performance optics is a means of reducing costs at a given size of beam because the number of lamps is one of the most cost driving factors in the construction of a solar simulator.

Juranek, H. J.

A new rapid method of solar simulator calibration

A quick method for checking solar simulator spectra content is presented. The method is based upon a solar cell of extended spectral sensitivity and known absolute response, and a dichroic mirror with the reflection transmission transition close to the peak wavelength of the Thekaekara AMO distribution. It compromises the need for spectral discrimination with the ability to integrate wide spectral regions of the distribution which was considered important due to the spiky nature of the high pressure xenon lamp in common use. The results are expressed in terms of a single number, the blue/red ratio, which, combined with the total (unfiltered) output, provides a simple adequate characterization. Measurements were conducted at eleven major facilities across the country and a total of eighteen simulators were measured including five pulsed units.

Ross, B.

Return to Mercury: A Comparison of Solar Simulation and Flight Data for the MESSENGER Spacecraft

The MErcury, Surface, Space, ENvironment GEochemistry and Ranging (MESSENGER) spacecraft is a NASA Discovery Mission spacecraft developed and operated by the Johns Hopkins University Applied Physics Laboratory. It was launched on August 3, 2004 and is currently on a course for Mercury orbit insertion in March 2011. To date the mission trajectory has taken the spacecraft to minimum solar distances of 0.332 and 0.313 AU and on January 14, 2008 the first flyby of Mercury in 33 years. From launch through the latest perihelion passage temperature performance data has been collected for the sun facing Digital Sun Sensors (DSS), the sun facing phased array and low gain (omni) antennas, the solar arrays, the sunshade and the two sun facing attitude control 4.4 N thrusters. Prior to launch, extensive solar simulation testing was conducted at the Glenn Research Center, Tank 6 solar simulation facility in Cleveland Ohio. Flight hardware qualification units representing these Sun exposed components were tested in solar environments that represented near mission minimum solar distance as to verify the thermal designs and the material used in fabrication. The paper will review the thermal designs of these components and their thermal performance to date as compared to the solar simulation testing.

Ercol, Carl J.

Design and Performance of a Triple Source Air Mass Zero Solar Simulator

Simulating the sun in a laboratory for the purpose of measuring solar cells has long been a challenge for engineers and scientists. Multi-junction cells demand higher fidelity of a solar simulator than do single junction cells, due to a need for close spectral matching as well as AM0 intensity. A GaInP/GaAs/Ge solar cell for example, requires spectral matching in three distinct spectral bands (figure 1). A commercial single source high-pressure xenon arc solar simulator such as the Spectrolab X-25 at NASA Glenn Research Center, can match the top two junctions of a GaInP/GaAs/Ge cell to within 1.3% mismatch, with the GaAs cell receiving slightly more current than required. The Ge bottom cell however, is mismatched +8.8%. Multi source simulators are designed to match the current for all junctions but typically have small illuminated areas, less uniformity and less beam collimation compared to an X-25 simulator. It was our intent when designing a multi source simulator to preserve as many aspects of the X-25 while adding multi-source capability.

Jenkins, Phillip

Flat-plate collector performance determined experimentally with a solar simulator

The NASA is constructing a new office building at Langley Research Center that will utilize solar energy for heating and cooling. A collector technology program is described which includes testing collectors in an indoor facility under simulated solar radiation. Tests have been conducted on five collectors to date and performance data are presented. The collector performance obtained with the solar simulator will be correlated with data obtained by conducting tests outdoors at Lewis.

Vernon, R. W.