Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPACE ORIENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

General expressions and physical origin of the coupling coefficient of arbitrary tuned coupled electromagnetic resonators

The theory and operation of various devices and systems, such as wireless power transfer via magnetic resonant coupling, magneto-inductive wave devices, magnetic resonance spectroscopy probes, and metamaterials can rely on coupled tuned resonators. The coupling strength is usually expressed in terms of the coupling coefficient κ, which can have electrical κ{sub E} and/or magnetic κ{sub M} components. In the current article, general expressions of κ are derived. The relation between the complex Poynting equation in its microscopic form and κ is made and discussed in detail. It is shown that κ can be expressed in terms of the interaction energy between the resonators' modes. It thus provides a general form that combines the magnetic and electric components of κ. The expressions make it possible to estimate the frequencies and fields of the coupled modes for arbitrarily oriented and spaced resonators. Thus, enabling the calculation of system specific parameters such as the transfer efficiency of wireless power transfer systems, resonator efficiency for electron spin resonance probes, and dispersion relations of magneto-inductive and stereo-metamaterials structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast switchable ferroelectric liquid crystal gratings with two electro-optical modes

In this article, we reveal a theoretical and experimental illustration of the Ferroelectric liquid crystal (FLC) grating fabricated by mean of patterned alignment based on photo-alignment. The complexity related to the mismatching of the predefined alignment domains on the top and bottom substrate has been avoided by incorporating only one side photo aligned substrate while the other substrate does not have any alignment layer. Depending on the easy axis in the said alignment domains and the azimuth plane of the impinging polarized light, the diffracting element can be tuned in two modes i.e. DIFF/OFF switchable and DIFF/TRANS switchable modes, which can be applied to different applications. The diffraction profile has been illustrated theoretically that fits well with the experimental finding and thus the proposed diffraction elements with fast response time and high diffraction efficiency could find application in many modern devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

EMERGENCE OF SMALL-SCALE MAGNETIC LOOPS THROUGH THE QUIET SOLAR ATMOSPHERE

We investigate the emergence of magnetic flux in the quiet Sun at very small spatial scales, focusing on the magnetic connection between the photosphere and chromosphere. The observational data consist of spectropolarimetric measurements and filtergrams taken with the Hinode satellite and the Dutch Open Telescope. We find that a significant fraction of the magnetic flux present in internetwork regions appears in the form of {omega}-shaped loops. The emergence rate is 0.02 loops per hour and arcsec{sup -2}, which brings 1.1 x 10{sup 12} Mx s{sup -1} arcsec{sup -2} of new flux to the solar surface. Initially, the loops are observed as small patches of linear polarization above a granular cell. Shortly afterward, two footpoints of opposite polarity become visible in circular polarization within or at the edges of the granule and start moving toward the adjacent intergranular space. The orientation of the footpoints does not seem to obey Hale's polarity rules. The loops are continuously buffeted by convective motions, but they always retain a high degree of coherence. Interestingly, 23% of the loops that emerge in the photosphere reach the chromosphere (16 cases out of 69). They are first detected in Fe I 630 nm magnetograms and 5 minutes later in Mg I b 517.3 nm magnetograms. After about 8 minutes, some of them are also observed in Ca II H line-core images, where the footpoints produce small brightness enhancements.

99 GENERAL AND MISCELLANEOUS↗

Anisotropic Superfluidity in a Dipolar Bose Gas

We study the superfluid character of a dipolar Bose-Einstein condensate (DBEC) in a quasi-two dimensional geometry. We consider the dipole polarization to have some nonzero projection into the plane of the condensate so that the effective interaction is anisotropic in this plane, yielding an anisotropic dispersion relation. By performing direct numerical simulations of a probe moving through the DBEC, we observe the sudden onset of drag or creation of vortex-antivortex pairs at critical velocities that depend strongly on the direction of the probe's motion. This anisotropy emerges because of the anisotropic manifestation of a rotonlike mode in the system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient analysis of small-angle scattering curves for large biomolecular assemblies using Monte Carlo methods

Structure elucidation from small-angle scattering curves of large biomolecular assemblies is notoriously challenging. This is because the simulation of high-resolution features in the structure of large macromolecular assemblies, such as de novo protein assemblies, is computationally demanding when it needs to cover a broad range of length scales. Conventional methods, such as the numerical approximation to the Debye equation or the use of spherical harmonics, do not scale well as the size of the assembly increases, which limits their application to small structures (e.g. individual proteins). This work explores the effectiveness of a Monte Carlo method to simulate and fit scattering curves for large biomolecular assemblies spanning over ranges covering atomic and molecular detail (e.g. spacing and orientation of proteins in an assembly) as well as large-scale (hundreds of nanometres) features. Owing to its speed and scalability, it can be combined with a fitting algorithm to extract structural features from experimental small-angle scattering curves in biomolecular assemblies that are otherwise intractable for interpretation. This work first demonstrates the effectiveness of the tool using experimental small-angle X-ray scattering (SAXS) data from tile-like proteins that assemble into 1D tube-like macromolecular structures. Here, the diameter distribution of tubes is extracted from SAXS fits, and this is quantitatively compared with distributions from electron microscopy. SAXS data are also obtained from 2D sheet-like protein assemblies, and the proposed method is used to quantify structural features such as the separation distance between protein building blocks and the flexing of the sheet. An open-source implementation of the methodology is provided for use in a broad range of biological systems involving multi-scale scattering analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computer aided detection of surgical retained foreign object for prevention

Purpose: Surgical retained foreign objects (RFOs) have significant morbidity and mortality. They are associated with approximately $1.5 × 10{sup 9} annually in preventable medical costs. The detection accuracy of radiographs for RFOs is a mediocre 59%. The authors address the RFO problem with two complementary technologies: a three-dimensional (3D) gossypiboma micro tag, the μTag that improves the visibility of RFOs on radiographs, and a computer aided detection (CAD) system that detects the μTag. It is desirable for the CAD system to operate in a high specificity mode in the operating room (OR) and function as a first reader for the surgeon. This allows for fast point of care results and seamless workflow integration. The CAD system can also operate in a high sensitivity mode as a second reader for the radiologist to ensure the highest possible detection accuracy. Methods: The 3D geometry of the μTag produces a similar two dimensional (2D) depiction on radiographs regardless of its orientation in the human body and ensures accurate detection by a radiologist and the CAD. The authors created a data set of 1800 cadaver images with the 3D μTag and other common man-made surgical objects positioned randomly. A total of 1061 cadaver images contained a single μTag and the remaining 739 were without μTag. A radiologist marked the location of the μTag using an in-house developed graphical user interface. The data set was partitioned into three independent subsets: a training set, a validation set, and a test set, consisting of 540, 560, and 700 images, respectively. A CAD system with modules that included preprocessing μTag enhancement, labeling, segmentation, feature analysis, classification, and detection was developed. The CAD system was developed using the training and the validation sets. Results: On the training set, the CAD achieved 81.5% sensitivity with 0.014 false positives (FPs) per image in a high specificity mode for the surgeons in the OR and 96.1% sensitivity with 0.81 FPs per image in a high sensitivity mode for the radiologists. On the independent test set, the CAD achieved 79.5% sensitivity with 0.003 FPs per image in a high specificity mode for the surgeons and 90.2% sensitivity with 0.23 FPs per image in a high sensitivity mode for the radiologists. Conclusions: To the best of the authors’ knowledge, this is the first time a 3D μTag is used to produce a recognizable, substantially similar 2D projection on radiographs regardless of orientation in space. It is the first time a CAD system is used to search for man-made objects over anatomic background. The CAD system for the μTags achieved reasonable performance in both the high specificity and the high sensitivity modes.

60 APPLIED LIFE SCIENCES↗

No ordinary proteins: Adsorption and molecular orientation of monoclonal antibodies

The interaction of monoclonal antibodies (mAbs) with air/water interfaces plays a crucial role in their overall stability in solution. We aim to understand this behavior using pendant bubble measurements to track the dynamic tension reduction and x-ray reflectivity to obtain the electron density profiles (EDPs) at the surface. Native immunoglobulin G mAb is a rigid molecule with a flat, “Y” shape, and simulated EDPs are obtained by rotating a homology construct at the surface. Comparing simulations with experimental EDPs, we obtain surface orientation probability maps showing mAbs transition from flat-on Y-shape configurations to side-on or end-on configurations with increasing concentration. The modeling also shows the presence of β sheets at the surface. Overall, the experiments and the homology modeling elucidate the orientational phase space during different stages of adsorption of mAbs at the air/water interface. These finding will help define new strategies for the manufacture and storage of antibody-based therapeutics.

59 BASIC BIOLOGICAL SCIENCES↗

Ultrafast dense DNA functionalization of quantum dots and rods for scalable 2D array fabrication with nanoscale precision

Scalable fabrication of two-dimensional (2D) arrays of quantum dots (QDs) and quantum rods (QRs) with nanoscale precision is required for numerous device applications. However, self-assembly–based fabrication of such arrays using DNA origami typically suffers from low yield due to inefficient QD and QR DNA functionalization. In addition, it is challenging to organize solution-assembled DNA origami arrays on 2D device substrates while maintaining their structural fidelity. Here, we reduced manufacturing time from a few days to a few minutes by preparing high-density DNA-conjugated QDs/QRs from organic solution using a dehydration and rehydration process. We used a surface-assisted large-scale assembly (SALSA) method to construct 2D origami lattices directly on solid substrates to template QD and QR 2D arrays with orientational control, with overall loading yields exceeding 90%. Our fabrication approach enables the scalable, high fidelity manufacturing of 2D addressable QDs and QRs with nanoscale orientational and spacing control for functional 2D photonic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Design and life-cycle considerations for unconventional-reservoir wells

This paper provides an overview of design and life-cycle considerations for certain unconventional-reservoir wells. An overview of unconventional-reservoir definitions is provided. Well design and life-cycle considerations are addressed from three aspects: upfront reservoir development, initial well completion, and well-life and long-term considerations. Upfront-reservoir-development issues discussed include well spacing, well orientation, reservoir stress orientations, and tubular metallurgy. Initial-well-completion issues include maximum treatment pressures and rates, treatment diversion, treatment staging, flowback and cleanup, and dewatering needs. Well-life and long-term discussions include liquid loading, corrosion, refracturing and associated fracture reorientation, and the cost of abandonment. These design considerations are evaluated with case studies for five unconventional-reservoir types: shale gas (Barnett shale), tight gas (Jonah feld), tight oil (Bakken play), coalbed methane (CBM) (San Juan basin), and tight heavy oil (Lost Hills field). In evaluating the life cycle and design of unconventional-reservoir wells, 'one size' does not fit all and valuable knowledge and a shortening of the learning curve can be achieved for new developments by studying similar, more-mature fields.

01 COAL, LIGNITE, AND PEAT↗

OpenStudio: A Platform for Ex Ante Incentive Programs

Many utilities operate programs that provide ex ante (up front) incentives for building energy conservation measures (ECMs). A typical incentive program covers two kinds of ECMs. ECMs that deliver similar savings in different contexts are associated with pre-calculated 'deemed' savings values. ECMs that deliver different savings in different contexts are evaluated on a 'custom' per-project basis. Incentive programs often operate at less than peak efficiency because both deemed ECMs and custom projects have lengthy and effort-intensive review processes--deemed ECMs to gain confidence that they are sufficiently context insensitive, custom projects to ensure that savings are claimed appropriately. DOE's OpenStudio platform can be used to automate ex ante processes and help utilities operate programs more efficiently, consistently, and transparently, resulting in greater project throughput and energy savings. A key concept of the platform is the OpenStudio Measure, a script that queries and transforms building energy models. Measures can be simple or surgical, e.g., applying different transformations based on space-type, orientation, etc. Measures represent ECMs explicitly and are easier to review than ECMs that are represented implicitly as the difference between a with-ECM and without-ECM models. Measures can be automatically applied to large numbers of prototype models--and instantiated from uncertainty distributions--facilitating the large scale analysis required to develop deemed savings values. For custom projects, Measures can also be used to calibrate existing building models, to automatically create code baseline models, and to perform quality assurance screening.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Apparatus and method for electroforming high aspect ratio micro-parts

A fixture is disclosed to more easily affix a workpiece in the proper orientation and spacing with sealed electrical interconnection within an electrochemical plating bath. The workpiece can be any planar metallic or non-metallic substrate such as a silicon wafer commonly used in LIGA or microsystem fabrication. The fixture described allows the workpiece to be submerged deep within an electrolytic cell, facing upwards, and allows easy transfer from one cell to another. The edges, backside, and electrical connections are sealed and protected from the electrolyte.

42 ENGINEERING↗

Probing orientation information using 3-dimensional reciprocal space volume analysis

We present that the crystallographic texture of polycrystalline materials is the result of how these materials are processed and what external forces materials have experienced. Neutron and X-ray diffraction are standard methods to characterize global crystallographic textures. However, conventional neutron and X-ray texture analyses rely on pole figure inversion routines derived from intensity analysis of individual reflections or powder Rietveld analysis to reconstruct and model the orientation distribution from slices through reciprocal space. In this work, we describe an original approach to directly probe the crystallographic texture information of rolled aluminum from the intensity distribution in 3-dimensional reciprocal space volumes measured simultaneously. Using the TOPAZ time-of-flight Laue neutron diffractometer, reciprocal space analysis allowed determination of “pole spheres” with <1° angular resolution. Finally, these pole spheres are compared with reconstructed pole figures from classic texture analysis.

36 MATERIALS SCIENCE↗

Orientational atom interferometers sensitive to gravitational waves

We present an atom interferometer that differs from common atom interferometers as it is not based on the spatial splitting of electronic wave functions, but on orienting atoms in space. As an example we present how an orientational atom interferometer based on highly charged hydrogen-like atoms is affected by gravitational waves. We show that a monochromatic gravitational wave will cause a frequency shift that scales with the binding energy of the system rather than with its physical dimension. For a gravitational wave amplitude of h=10{sup -23} the frequency shift is of the order of 110 {mu}Hz for an atom interferometer based on a 91-fold charged uranium ion. A frequency difference of this size can be resolved by current atom interferometers in 1 s.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NEXAFS Microscopy and Resonant Scattering: Composition and Orientation Probed in Real and Reciprocal Space

Near Edge X-ray Absorption Fine Structure (NEXAFS) spectromicroscopy, resonant scattering and resonant reflectivity are specialized, synchrotron radiation based, soft X-ray characterization tools that provide moiety-specific contrast and either real-space imaging at {approx}30 nm spatial resolution, or scattering signals which can be inverted to provide chemically sensitive information at an even higher spatial resolution (<5 nm). These X-ray techniques complement other real and reciprocal space characterization tools such as various microscopies and conventional electron, X-ray and neutron scattering. We provide an overview of these synchrotron based tools, describe their present state-of-the-art and discuss a number of applications to exemplify their unique aspects.

43 PARTICLE ACCELERATORS↗

Interference in electron–molecule elastic scattering

General formulas describing the multiple scattering of electron by polyatomic molecules have been derived within the framework of the model of non-overlapping atomic potentials. These formulas are applied to different carbon molecules, both for fixed-in-space and randomly oriented molecules. Here, the molecular continuum wave function is represented as a plane wave plus a linear combination of the Green’s functions for free motion and the derivatives of these functions. Far from the target the electron spherical waves interfere as in the case of the Young’s double slits experiment. This interference manifests itself as diffraction oscillations in the differential and total cross sections for elastic electron scattering. The amplitude of electron scattering by a molecule is defined by the phase shifts for each of the atoms forming the target and its geometry. The numerical calculation of the scattering amplitude in closed form (rather than in the form of S-matrix expansion) is reduced to solving a system of algebraic equations. The number of atoms in a molecule and the atomic phase shifts for the orbital angular momenta included in the calculation define the number of equations.

74 ATOMIC AND MOLECULAR PHYSICS↗

PRECISION POINTING OF IBEX-Lo OBSERVATIONS

Post-launch boresight of the IBEX-Lo instrument on board the Interstellar Boundary Explorer (IBEX) is determined based on IBEX-Lo Star Sensor observations. Accurate information on the boresight of the neutral gas camera is essential for precise determination of interstellar gas flow parameters. Utilizing spin-phase information from the spacecraft attitude control system (ACS), positions of stars observed by the Star Sensor during two years of IBEX measurements were analyzed and compared with positions obtained from a star catalog. No statistically significant differences were observed beyond those expected from the pre-launch uncertainty in the Star Sensor mounting. Based on the star observations and their positions in the spacecraft reference system, pointing of the IBEX satellite spin axis was determined and compared with the pointing obtained from the ACS. Again, no statistically significant deviations were observed. We conclude that no systematic correction for boresight geometry is needed in the analysis of IBEX-Lo observations to determine neutral interstellar gas flow properties. A stack-up of uncertainties in attitude knowledge shows that the instantaneous IBEX-Lo pointing is determined to within {approx}0.{sup 0}1 in both spin angle and elevation using either the Star Sensor or the ACS. Further, the Star Sensor can be used to independently determine the spacecraft spin axis. Thus, Star Sensor data can be used reliably to correct the spin phase when the Star Tracker (used by the ACS) is disabled by bright objects in its field of view. The Star Sensor can also determine the spin axis during most orbits and thus provides redundancy for the Star Tracker.

79 ASTRONOMY AND ASTROPHYSICS↗

Developing new optical imaging techniques for single particle and molecule tracking in live cells

Differential interference contrast (DIC) microscopy is a far-field as well as wide-field optical imaging technique. Since it is non-invasive and requires no sample staining, DIC microscopy is suitable for tracking the motion of target molecules in live cells without interfering their functions. In addition, high numerical aperture objectives and condensers can be used in DIC microscopy. The depth of focus of DIC is shallow, which gives DIC much better optical sectioning ability than those of phase contrast and dark field microscopies. In this work, DIC was utilized to study dynamic biological processes including endocytosis and intracellular transport in live cells. The suitability of DIC microscopy for single particle tracking in live cells was first demonstrated by using DIC to monitor the entire endocytosis process of one mesoporous silica nanoparticle (MSN) into a live mammalian cell. By taking advantage of the optical sectioning ability of DIC, we recorded the depth profile of the MSN during the endocytosis process. The shape change around the nanoparticle due to the formation of a vesicle was also captured. DIC microscopy was further modified that the sample can be illuminated and imaged at two wavelengths simultaneously. By using the new technique, noble metal nanoparticles with different shapes and sizes were selectively imaged. Among all the examined metal nanoparticles, gold nanoparticles in rod shapes were found to be especially useful. Due to their anisotropic optical properties, gold nanorods showed as diffraction-limited spots with disproportionate bright and dark parts that are strongly dependent on their orientation in the 3D space. Gold nanorods were developed as orientation nanoprobes and were successfully used to report the self-rotation of gliding microtubules on kinesin coated substrates. Gold nanorods were further used to study the rotational motions of cargoes during the endocytosis and intracellular transport processes in live mammalian cells. New rotational information was obtained: (1) during endocytosis, cargoes lost their rotation freedom at the late stage of internalization; (2) cargoes performed train-like motion when they were transported along the microtubule network by motor proteins inside live cells; (3) During the pause stage of fast axonal transport, cargoes were still bound to the microtubule tracks by motor proteins. Total internal reflection fluorescence microscopy (TIRFM) is another non-invasive and far-field optical imaging technique. Because of its near-field illumination mechanism, TIRFM has better axial resolution than epi-fluorescence microscopy and confocal microscopy. In this work, an auto-calibrated, prism type, angle-scanning TIRFM instrument was built. The incident angle can range from subcritical angles to nearly 90°, with an angle interval less than 0.2°. The angle precision of the new instrument was demonstrated through the finding of the surface plasmon resonance (SPR) angle of metal film coated glass slide. The new instrument improved significantly the precision in determining the axial position. As a result, the best obtained axial resolution was ~ 8 nm, which is better than current existing instruments similar in function. The instrument was further modified to function as a pseudo TIRF microscope. The illumination depth can be controlled by changing the incident angle of the excitation laser beam or adjusting the horizontal position of the illumination laser spot on the prism top surface. With the new technique, i.e., variable-illumination-depth pseudo TIRF microscopy, the whole cell body from bottom to top was scanned.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗