Search NASA⌕ Search

SEARCH · Search NASA

Results for “SPECTRAL RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Search for TiO and Optical Nightside Emission from the Exoplanet WASP-33b

With a temperature akin to an M dwarf, WASP-33b is among the hottest Jupiters known, making it an ideal target for high-resolution optical spectroscopy. By analyzing both transmission and emission spectra, we aim to substantiate previous reports of atmospheric TiO and a thermal inversion within the planet’s atmosphere. We observed two transits and six arcs of the phase curve with the Echelle SpectroPolarimetric Device for the Observation of Stars (ESPaDOnS) on the Canada–France–Hawaii Telescope and High Resolution Echelle Spectrometer (HIRES) on the Keck telescope, which provide high spectral resolution and ample wavelength coverage. We employ the Doppler cross-correlation technique to search for the molecular signatures of TiO and H{sub 2}O in these spectra, using models based on the TiO line list of Plez. Though we cannot exclude line-list-dependent effects, our data do not corroborate previous indications of a thermal inversion. Instead we place a 3σ upper limit of 10{sup −9} on the volume mixing ratio of TiO for the T–P profile we consider. While we are unable to constrain the volume mixing ratio of water, our strongest constraint on TiO comes from dayside emission spectra. This apparent absence of a stratosphere sits in stark contrast to previous observations of WASP-33b as well as theoretical predictions for the atmospheres of highly irradiated planets. The discrepancy could be due to variances between line lists, and we stress that detection limits are only as good as the line list employed, and are only valid for the specific T–P profile considered due to the strong degeneracy between lapse rate (dT/dlogP) and molecular abundance.

79 ASTRONOMY AND ASTROPHYSICS↗

DRAGraces: A Pipeline for the GRACES High-resolution Spectrograph at Gemini

This paper describes the software Data Reduction and Analysis for GRACES (DRAGraces), which is a pipeline reducing spectra from Gemini Remote Access to the CFHT ESPaDOnS Spectrograph (GRACES) at the Gemini North Telescope. The code is written in the IDL language. It is designed to find all the GRACES frames in a given directory, automatically determine the list of bias, flat, arc, and science frames, and perform the whole reduction and extraction within a few minutes. We compare the output from DRAGraces with that of the Open source Pipeline for ESPaDOnS Reduction and Analysis (OPERA), a pipeline developed at the Canada–France–Hawaii Telescope (CFHT) that also can extract GRACES spectra. Both pipelines were developed completely independently, yet they give very similar extracted spectra. They both have their advantages and disadvantages. For instance, DRAGraces is more straightforward and easy to use and is less likely to be derailed by a parameter that needs to be tweaked, while OPERA offers a more careful extraction that can be significantly superior when the highest resolution is required and when the signal-to-noise ratio is low. One should compare both before deciding which one to use for their science. Yet, both pipelines deliver a fairly comparable resolution power (R ~ 52.8k and 36.6k for DRAGraces and R ~ 58k and 40k for OPERA in high- and low-resolution spectral modes, respectively), wavelength solution, and signal-to-noise ratio per resolution element.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic Search of Cataclysmic Variables Based on LightGBM in LAMOST-DR7

The search for special and rare celestial objects has always played an important role in astronomy. Cataclysmic Variables (CVs) are special and rare binary systems with accretion disks. Most CVs are in the quiescent period, and their spectra have the emission lines of Balmer series, HeI, and HeII. A few CVs in the outburst period have the absorption lines of Balmer series. Owing to the scarcity of numbers, expanding the spectral data of CVs is of positive significance for studying the formation of accretion disks and the evolution of binary star system models. At present, the research for astronomical spectra has entered the era of Big Data. The Large Sky Area Multi-Object Fiber Spectroscopy Telescope (LAMOST) has produced more than tens of millions of spectral data. the latest released LAMOST-DR7 includes 10.6 million low-resolution spectral data in 4926 sky regions, providing ideal data support for searching CV candidates. To process and analyze the massive amounts of spectral data, this study employed the Light Gradient Boosting Machine (LightGBM) algorithm, which is based on the ensemble tree model to automatically conduct the search in LAMOST-DR7. Finally, 225 CV candidates were found and four new CV candidates were verified by SIMBAD and published catalogs. This study also built the Gradient Boosting Decision Tree (GBDT), Adaptive Boosting (AdaBoost), and eXtreme Gradient Boosting (XGBoost) models and used Accuracy, Precision, Recall, the F1-score, and the ROC curve to compare the four models comprehensively. Experimental results showed that LightGBM is more efficient. The search for CVs based on LightGBM not only enriches the existing CV spectral library, but also provides a reference for the data mining of other rare celestial objects in massive spectral data.

79 ASTRONOMY AND ASTROPHYSICS↗

NACHOS, a CubeSat-based high-resolution UV-Visible hyperspectral imager for remote sensing of trace gases: system overview and science objectives

Here, the Nano-satellite Atmospheric Chemistry Hyperspectral Observation System (NACHOS) is a high-throughput (f/2.9), high spectral resolution (~1.3 nm optical resolution, 0.6 nm sampling) Offner-design hyperspectral imager operating in the 300-500 nm spectral region. The 1.5U instrument payload (1U optical system, 0.5U electronics module) is hosted by a 1.5U LANL-designed CubeSat bus to comprise a 3U complete satellite. Spectroscopically similar to NASA’s Ozone Monitoring Instrument (OMI), which provides wide-field global mapping of ozone and other gases at coarse spatial resolution, NACHOS fills the complementary niche of targeted measurements at much higher spatial resolution. With 350 across-track spatial pixels and a 15-degree across-track field of view, NACHOS will provide spectral imaging at roughly 0.4 km per pixel from 500 km altitude. NACHOS incorporates highly streamlined gas-retrieval algorithms for rapid onboard processing, alleviating the need to routinely downlink massive hyperspectral data cubes. We will discuss the instrument design, challenges in achieving mechanical robustness to launch vibration in such a compact instrument, the onboard calibration system, and gas-retrieval data downlink strategy. We will also discuss potential science missions, including monitoring of NO 2 as an easily detected proxy for anthropogenic fossil-fuel greenhouse gases, monitoring lowlevel SO 2 degassing at pre-eruptive volcanoes, H 2 CO from wildfires, and characterization of aerosols. The long-term vision is for a many-satellite constellation that could provide both high spatial resolution and frequent revisits for selected targets of interest. As an initial technology demonstration of this vision, the NACHOS project is currently slated to launch two CubeSats in early 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Development of a Low-Cost, Sensitivity-Optimized Fluorescence Sensor for Visible Spectrum Analysis

This paper presents an economically viable, sensitivity-optimized fluorescence sensor for detecting low concentrations of fluorophores in the visible spectrum range. The sensor employs a deep ultraviolet (DUV) 275-nm LED and a dichroic mirror to establish a co-axial optical path for excitation and emission. Instead of utilizing a general-purposed spectrometer optimized for high spectral resolution, the sensor strikes a balance between resolution and sensitivity by using an appropriate aperture size and optimized optical design tailored for the spectral characteristics of fluorophores. Here, the manuscript demonstrates measurements of ppb-level rare earth element (REE) samples containing terbium (Tb), europium (Eu), dysprosium (Dy), and samarium (Sm) in aqueous solutions. Through balanced design that optimizes collection of fluorescence emission without losing spectral information, this work shows the feasibility of developing a low-cost, compact, and highly sensitive fluorescence sensors with improved detection sensitivity when compared to bench-top commercial spectrofluorometers at far higher costs.

47 OTHER INSTRUMENTATION↗

Core line spread function calibration of the X-ray Imaging and Spectroscopy Mission Resolve X-ray calorimeter spectrometer

The Resolve X-ray imaging spectrometer onboard the X-ray Imaging and Spectroscopy Mission consists of a 36 pixel array of high-resolution X-ray calorimeters each with ∼ 5 eV full-width-at-half-maximum (FWHM) spectral resolution in the 0.3 to 12 keV band. The response to monochromatic X-rays (line spread function, LSF) is composed of a narrow Gaussian core and weak extended components caused by energy loss during thermalization. We report on the characterization of the Gaussian core LSF in an extensive ground calibration campaign. We also discuss the characterization of on-orbit resolution, which shows slightly higher FWHM than that obtained on the ground.

Astronomy and AstroPhysics↗

Towards mapping biodiversity from above: Can fusing lidar and hyperspectral remote sensing predict taxonomic, functional, and phylogenetic tree diversity in temperate forests?

Abstract Aim Rapid global change is impacting the diversity of tree species and essential ecosystem functions and services of forests. It is therefore critical to understand and predict how the diversity of tree species is spatially distributed within and among forest biomes. Satellite remote sensing platforms have been used for decades to map forest structure and function but are limited in their capacity to monitor change by their relatively coarse spatial resolution and the complexity of scales at which different dimensions of biodiversity are observed in the field. Recently, airborne remote sensing platforms making use of passive high spectral resolution (i.e., hyperspectral) and active lidar data have been operationalized, providing an opportunity to disentangle how biodiversity patterns vary across space and time from field observations to larger scales. Most studies to date have focused on single sites and/or one sensor type; here we ask how multiple sensor types from the National Ecological Observatory Network’s Airborne Observation Platform (NEON AOP) perform across multiple sites in a single biome at the NEON field plot scale (i.e., 40 m × 40 m). Location Eastern USA. Time period 2017–2018. Taxa studied Trees. Methods With a fusion of hyperspectral and lidar data from the NEON AOP, we assess the ability of high resolution remotely sensed metrics to measure biodiversity variation across eastern US temperate forests. We examine how taxonomic, functional, and phylogenetic measures of alpha diversity vary spatially and assess to what degree remotely sensed metrics correlate with in situ biodiversity metrics. Results Models using estimates of forest function, canopy structure, and topographic diversity performed better than models containing each category alone. Our results show that canopy structural diversity, and not just spectral reflectance, is critical to predicting biodiversity. Main conclusions We found that an approach that jointly leverages spectral properties related to leaf and canopy functional traits and forest health, lidar derived estimates of forest structure, fine‐resolution topographic diversity, and careful consideration of biogeographical differences within and among biomes is needed to accurately map biodiversity variation from above.

54 ENVIRONMENTAL SCIENCES↗

Analysis of several high-resolution infrared bands of perdeutero-spiropentane, C5D8

Perdeutero-spiropentane (C5D8) has been synthesized and infrared spectra were taken from 400 to 4000 cm-1 at low sample pressures in a 22 meter multipass cell. The spectral resolution (0.0015 cm-1) reveals thousands of individual rovibrational transitions for several fundamental bands occurring in the spectral region of 500 to 1100 cm-1. C5D8 ground state constants reported in a previous study of a ?15 parallel band at 1054 cm-1 [1] were improved significantly in the present work by adding combination-differences derived from ?16 parallel and ?24 perpendicular band analyses. The larger data set at higher J values also allowed determination of the ground state K? = 2 splitting constant (?2? = 0.76(2) ×10-9 cm-1). For ?16, the band origin is 847.16933(5) cm-1 and changes in upper state rotational constants are ?A = –0.0013411(5) and ?B = –0.0002021(1) (in units of cm-1). Overlapping, and in Fermi resonance with ?16, is a second parallel band which, from Gaussian calculations at the anharmonic level, is assigned as the b2 combination ?8+?12, with band origin of 840.5434(1) and ?A = –0.0003500(7) and ?B = –0.0003502(1) cm-1. For ?24 analogous values are 556.41453(2) and ?A = –0.00032295(9) and ?B = –0.00016782(4) cm-1. The analyses also yields accurate values for the changes in both quartic and sextic centrifugal distortion constants and, for ?24, values for the l-doubling constants q+ and q-. Theoretical calculations of the rovibrational parameters aided in the analysis and the numerical values are in good agreement with experimental results.

Nibler, Joseph W.↗

Stochastic Real-Time Second-Order Green’s Function Theory for Neutral Excitations in Molecules and Nanostructures

We present a real-time second-order Green’s function (GF) method for computing excited states in molecules and nanostructures, with a computational scaling of O(N e 3 ), where N e is the number of electrons. The cubic scaling is achieved by adopting the stochastic resolution of the identity to decouple the 4-index electron repulsion integrals. To improve the time propagation and the spectral resolution, we adopt the dynamic mode decomposition technique and assess the accuracy and efficiency of the combined approach for a chain of hydrogen dimer molecules of different lengths. We find that the stochastic implementation accurately reproduces the deterministic results for the electronic dynamics and excitation energies. Furthermore, we provide a detailed analysis of the statistical errors, bias, and long-time extrapolation. Overall, the approach offers an efficient route to investigate excited states in extended systems with open or closed boundary conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Smart Scattering Scanning Near-Field Optical Microscopy

Scattering scanning near-field optical microscopy (s-SNOM) provides spectroscopic imaging from molecular to quantum materials with few nanometer deep subdiffraction limited spatial resolution. However, in its conventional implementation s-SNOM is slow to effectively acquire a series of spatio-spectral images, especially with large fields of view. This problem is further exacerbated for weak resonance contrast or when using light sources with limited spectral irradiance. Indeed, the generally limited signal-to-noise ratio prevents sampling a weak signal at the Nyquist sampling rate. Here, we demonstrate how acquisition time and sampling rate can be significantly reduced by using compressed sampling, matrix completion, and adaptive random sampling, while maintaining or even enhancing the physical or chemical image content. We use fully sampled real data sets of molecular, biological, and quantum materials as ground-truth physical data and show how deep under-sampling with a corresponding reduction of acquisition time by 1 order of magnitude or more retains the core s-SNOM image information. We demonstrate that a sampling rate of up to 6× smaller than the Nyquist criterion can be applied, which would provide a 30-fold reduction in the data required under typical experimental conditions. Furthermore, our smart s-SNOM approach is generally applicable and provides systematic full spatio-spectral s-SNOM imaging with a large field of view at high spectral resolution and reduced acquisition time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2nd and 3rd order spectral energy corrections with penumbral de-blurring methodology for opacity platform used on the National Ignition Facility

The Opacity Spectrometer (OpSpec) used in the National Ignition Facility’s opacity experiments measures x-ray spectra from 0.9 to 2.1 keV from the different experimental regions: the backlight source, emission source, and the absorption region with the transmission calculated from these regions. The OpSpec designs have gone through several iterations to help improve the signal-to-noise ratio, remove alternate crystal plane reflections, and improve spectral resolution, which helps to increase the validity of the opacity measurements. However, the source spans well outside the current working spectral range, and higher-order reflections are intrinsic to the crystal, which increases the overall signal seen in the data regions. The recorded data are the convolution of 1st order transmission, higher-order reflections, and the penumbra blurring. In conclusion, this work represents the details for deconvolving the 2nd and 3rd order spectral energy corrections with a penumbral de-blurring to correct the relative measurement of x-ray intensity of different spectral energies and further analysis of datasets relevant to the opacity experiments.

47 OTHER INSTRUMENTATION↗

Narrow-bandwidth tunable optical filter stabilized by Newton’s rings fringe analysis

The resolution of grating spectrometers is insufficient to resolve many features present in the emission spectra of solid-state quantum emitters. Spectral resolution may be improved by inserting a Fabry–Perot interferometer (FPI) whose length is tuned by a piezoelectric actuator. Yet piezo creep and thermal fluctuations cause instability that makes this solution unsuitable for measurement times longer than tens of seconds. To overcome this challenge, we employ active feedback derived from the Newton’s rings interference pattern formed by the reflection of a single-frequency laser from the FPI cavity. The resulting FPI transmission frequency is stable to within 50 MHz over several hours.

KC, Raju Bhai (ORCID:0000000267406588)↗

APOGEE Net: Improving the Derived Spectral Parameters for Young Stars through Deep Learning

Machine learning allows for efficient extraction of physical properties from stellar spectra that have been obtained by large surveys. The viability of machine-learning approaches has been demonstrated for spectra covering a variety of wavelengths and spectral resolutions, but most often for main-sequence (MS) or evolved stars, where reliable synthetic spectra provide labels and data for training. Spectral models of young stellar objects (YSOs) and low-mass MS stars are less well-matched to their empirical counterparts, however, posing barriers to previous approaches to classify spectra of such stars. In this work, we generate labels for YSOs and low-mass MS stars through their photometry. We then use these labels to train a deep convolutional neural network to predict logg, T {sub eff}, and Fe/H for stars with Apache Point Observatory Galactic Evolution Experiment (APOGEE) spectra in the DR14 data set. This “APOGEE Net” has produced reliable predictions of logg for YSOs, with uncertainties of within 0.1 dex and a good agreement with the structure indicated by pre-MS evolutionary tracks, and it correlates well with independently derived stellar radii. These values will be useful for studying pre-MS stellar populations to accurately diagnose membership and ages.

79 ASTRONOMY AND ASTROPHYSICS↗

Microsecond fingerprint stimulated Raman spectroscopic imaging by ultrafast tuning and spatial-spectral learning

Label-free vibrational imaging by stimulated Raman scattering (SRS) provides unprecedented insight into real-time chemical distributions. Specifically, SRS in the fingerprint region (400–1800 cm -1 ) can resolve multiple chemicals in a complex bio-environment. However, due to the intrinsic weak Raman cross-sections and the lack of ultrafast spectral acquisition schemes with high spectral fidelity, SRS in the fingerprint region is not viable for studying living cells or large-scale tissue samples. Here, we report a fingerprint spectroscopic SRS platform that acquires a distortion-free SRS spectrum at 10 cm -1 spectral resolution within 20 µs using a polygon scanner. Meanwhile, we significantly improve the signal-to-noise ratio by employing a spatial-spectral residual learning network, reaching a level comparable to that with 100 times integration. Collectively, our system enables high-speed vibrational spectroscopic imaging of multiple biomolecules in samples ranging from a single live microbe to a tissue slice.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reagent-free Hyperspectral Diagnosis of SARS-CoV-2 Infection in Saliva Samples

Rapid, reagent-free pathogen-agnostic diagnostics that can be performed at the point of need are vital for preparedness against future outbreaks. Yet, many current strategies are pathogen-specific and require several reagents. We present hyperspectral sensing, using light to non-invasively measure the composition of several molecules to form a spectral signature, to overcome these barriers. To generate these spectral signatures, we present the ProSpectral TM V1, a novel, miniaturized hyperspectral platform with high spectral resolution with two mini-spectrometers. Furthermore, we developed state-of-the-art ML pipelines for near real-time analysis of spectral signatures in saliva samples. We found that we could accurately identify SARS-CoV-2 infection status in double-blinded saliva samples and demonstrate 100% accuracy on a hold out test dataset. To our knowledge, this establishes the fastest hyperspectral diagnostic platform and in a small form factor, and executable with liquid samples, without ligands or reagents, all while maintaining PCR level specificity and sensitivity.

59 BASIC BIOLOGICAL SCIENCES↗

Multichannel spectral estimation in acoustics: A state-space approach

Spectral estimation is a necessary methodology to analyze the frequency content of noisy data sets especially in acoustic applications. Many spectral techniques have evolved starting with the classical Fourier transform methods based on the well-known Wiener-Khintchine relationship relating the covariance-to-spectral density as a transform pair culminating with more elegant model-based parametric techniques that apply prior knowledge of the data to produce a high-resolution spectral estimate. Multichannel spectral representations are a class of both nonparametric, as well as parametric, estimators that provide improved spectral estimates. In any case, classical nonparametric multichannel techniques can provide reasonable estimates when coupled with peak-peaking methods as long as the signal levels are reasonably high. Furthermore, parametric multichannel methods can perform quite well in low signal level environments even when applying simple peak-picking techniques. In this paper, the performance of both nonparametric (periodogram) and parametric (state-space) multichannel spectral estimation methods are investigated when applied to both synthesized noisy structural vibration data as well as data obtained from a sounding rocket flight. It is demonstrated that for the multichannel problem, state-space techniques provide improved performance, offering a parametric alternative compared to classical methods.

42 ENGINEERING↗

Resonant inelastic x-ray scattering in warm-dense Fe compounds beyond the SASE FEL resolution limit

Resonant inelastic x-ray scattering (RIXS) is a widely used spectroscopic technique, providing access to the electronic structure and dynamics of atoms, molecules, and solids. However, RIXS requires a narrow bandwidth x-ray probe to achieve high spectral resolution. The challenges in delivering an energetic monochromated beam from an x-ray free electron laser (XFEL) thus limit its use in few-shot experiments, including for the study of high energy density systems. Here we demonstrate that by correlating the measurements of the self-amplified spontaneous emission (SASE) spectrum of an XFEL with the RIXS signal, using a dynamic kernel deconvolution with a neural surrogate, we can achieve electronic structure resolutions substantially higher than those normally afforded by the bandwidth of the incoming x-ray beam. We further show how this technique allows us to discriminate between the valence structures of Fe and Fe2O3, and provides access to temperature measurements as well as M-shell binding energies estimates in warm-dense Fe compounds.

74 ATOMIC AND MOLECULAR PHYSICS↗