Search NASA⌕ Search

SEARCH · Search NASA

Results for “SSD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Method and apparatus for offloading compute resources to a flash co-processing appliance

Solid-State Drive (SSD) burst buffer nodes are interposed into a parallel supercomputing cluster to enable fast burst checkpoint of cluster memory to or from nearby interconnected solid-state storage with asynchronous migration between the burst buffer nodes and slower more distant disk storage. The SSD nodes also perform tasks offloaded from the compute nodes or associated with the checkpoint data. For example, the data for the next job is preloaded in the SSD node and very fast uploaded to the respective compute node just before the next job starts. During a job, the SSD nodes perform fast visualization and statistical analysis upon the checkpoint data. The SSD nodes can also perform data reduction and encryption of the checkpoint data.

97 MATHEMATICS AND COMPUTING↗

LLE Review 114 (January-March 2008)

This volume of the LLE Review, covering January-March 2008, features 'Cryogenic Targets: Current Status and Future Development', by D. R. Harding, D. H. Edgell, M. D. Wittman, L. M. Elasky, S. J. Verbridge, A. J. Weaver, L. D. Lund, W. Seka, W. T. Shmayda, R. T. Janezic, M. J. Shoup III, M. Moore, R. Junquist, and A. V. Okishev. In this article (p. 57), the authors report on the status of layering cryogenic DT and D{sub 2} targets at LLE for inertial confinement fusion (ICF) targets. This critical effort achieves the important milestone of routinely providing cryogenic DT targets that meet the 1.0-{micro}m (rms) OMEGA ice-quality-surface specification. The best D{sub 2}-ice layers produced so far (rms roughness of 1.1 {micro}m) are approaching the quality typically achieved in DT targets. Efforts to improve the consistency of this process are reported along with investigations supporting the National Ignition Campaign studying issues relevant to indirect-drive and direct-drive cryogenic targets. Additional highlights of recent research presented in this issue include the following: (1) an improved laser speckle smoothing scheme that augments the current NIF 1-D SSD system by using multiple-FM modulators (MultiFM 1-D SSD) (p. 73). With a judicious choice of modulator frequencies, MultiFM 1-D SSD smoothes resonances produced at the higher spatial frequencies and can attain similar or even faster smoothing rates compared to the baseline NIF 2-D SSD system. DRACO simulations have shown that MultiFM 1-D SSD beam smoothing is sufficient for the direct-drive-ignition targets and pulse shapes analyzed thus far, and may even allow reducing the bandwidth enough to eliminate the need for dual-tripler frequency conversion on the NIF. (2) describes a time-gated, monoenergetic proton radiography that provides unique measurements of implosion dynamics of spherical targets in direct-drive inertial confinement fusion (ICF) (p. 81). Radiographs obtained at different implosion times, from acceleration, through coasting, deceleration, to final stagnation, display a comprehensive picture of spherical ICF implosion. Critical information inferred from such images characterizes the spatial structure and temporal evolution of self-generated fields and plasma areal density. (3) describes a single-shot cross-correlator based on a pulse replicator that produces a discrete sequence of sampling pulses that are nonlinearly mixed with the pulse under test (p. 86). The combination of a high reflector and partial reflector replicates an optical pulse by multiple internal reflections and generates a sequence of spatially displaced and temporally delayed sampling pulses. This principle is used in a cross-correlator characterizing optical pulses at 1053 nm, where a dynamic range higher than 60 dB is obtained over a temporal range larger than 200 ps. The dynamic range can be extended with standard optical-density filters and the temporal range extended with larger optics. (4) presents a novel focal-spot diagnostic developed for OMEGA EP that will be used to characterize on-shot focal spots to support high-quality laser-matter interaction experiments (p. 94). The complex fields in the region of the high-energy focus are calculated using high-resolution measurements of the main beam wavefront using the focal-spot diagnostic (FSD) located on the short-pulse diagnostic package and a careful calibration of the transfer wavefront between the FSD instrument and target chamber center. The concept of this calibration procedure is experimentally verified in the Multi-Terawatt (MTW) Laser System, which serves as a development platform for OMEGA EP. A technique based on phase retrieval is employed for the transfer-wavefront calibration since the OMEGA EP infrastructure cannot be replicated in the MTW laser; however, this approach also shows promise as an alternative method for OMEGA EP. (5) report on a systematic study to improve the laser-damage resistance of multilayer high-reflector coatings for use at 351 nm on the OMEGA EP Laser System (p. 103). A series of ha

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Model-Based Detection Scheme for Spoofed Sensor Data in Grid-Connected Inverters

In this article, a novel method to detect spoofed sensor data (SSD) for grid-connected inverters is proposed. First, a Kalman filter is used to estimate the inverter status in the proposed method. Then, the impact of SSD on the residual between estimation and control reference is analyzed. By leveraging the standard error of residual, an adaptive cumulative sum (CUSUM) chart is developed to achieve fast SSD detection and improve robustness. In addition, the proposed SSD detection method is verified by the hardware experiment. A comparative experiment with a conventional method also demonstrates the rapidity and robustness of the proposed method. Lastly, the performance of the proposed method under different noise covariance matrices is analyzed. Comprehensive analysis shows that the proposed method meets the detection requirement in IEEE 1547 Standard.

42 ENGINEERING↗

ASA-FTL: An adaptive separation aware flash translation layer for solid state drives

Here, the flash-memory based Solid State Drive (SSD) presents a promising storage solution for increasingly critical data-intensive applications due to its low latency (high throughput), high bandwidth, and low power consumption. Within an SSD, its Flash Translation Layer (FTL) is responsible for exposing the SSD’s flash memory storage to the computer system as a simple block device. The FTL design is one of the dominant factors determining an SSD’s lifespan and performance. To reduce the garbage collection overhead and deliver better performance, we propose a new, low-cost, adaptive separation-aware flash translation layer (ASA-FTL) that combines sampling, data clustering and selective caching of recency information to accurately identify and separate hot/cold data while incurring minimal overhead. We use sampling for light-weight identification of separation criteria, and our dedicated selective caching mechanism is designed to save the limited RAM resource in contemporary SSDs. Using simulations of ASA-FTL with both real-world and synthetic workloads, we have shown that our proposed approach reduces the garbage collection overhead by up to 28% and the overall response time by 15% compared to one of the most advanced existing FTLs. We find that the data clustering using a small sample size provides significant performance benefit while only incurring a very small computation and memory cost. In addition, our evaluation shows that ASA-FTL is able to adapt to the changes in the access pattern of workloads, which is a major advantage comparing to existing fixed data separation methods.

97 MATHEMATICS AND COMPUTING↗

Mitigation of cross-beam energy transfer: Implication of two-state focal zooming on OMEGA

Cross-beam energy transfer (CBET) during OMEGA low-adiabat cryogenic experiments reduces the hydrodynamic efficiency by ∼35%, which lowers the calculated one-dimensional (1-D) yield by a factor of 7. CBET can be mitigated by reducing the diameter of the laser beams relative to the target diameter. Reducing the diameter of the laser beams by 30%, after a sufficient conduction zone has been generated (two-state zooming), is predicted to maintain low-mode uniformity while recovering 90% of the kinetic energy lost to CBET. A radially varying phase plate is proposed to implement two-state zooming on OMEGA. A beam propagating through the central half-diameter of the phase plate will produce a large spot, while a beam propagating through the outer annular region of the phase plate will produce a narrower spot. To generate the required two-state near-field laser-beam profile, a picket driver with smoothing by spectral dispersion (SSD) would pass through an apodizer, forming a beam of half the standard diameter. A second main-pulse driver would co-propagate without SSD through its own apodizer, forming a full-diameter annular beam. Hydrodynamic simulations, using the designed laser spots produced by the proposed zooming scheme on OMEGA, show that implementing zooming will increase the implosion velocity by 25% resulting in a 4.5× increase in the 1-D neutron yield. Demonstrating zooming on OMEGA would validate a viable direct-drive CBET mitigation scheme and help establish a pathway to hydrodynamically equivalent direct-drive–ignition implosions by increasing the ablation pressure (1.6×), which will allow for more stable implosions at ignition-relevant velocities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterizing Impacts of Storage Faults on HPC Applications: A methodology and insights

In recent years, the increasing complexity in scientific simulations and emerging demands for training heavy artificial intelligence models require massive and fast data accesses, which urges high-performance computing (HPC) platforms to equip with more advanced storage infrastructures such as solid-state disks (SSDs). While SSDs offer high-performance I/O, it remains unclear about the reliability challenges faced by the HPC applications under the SSD-related failures, in particular, failures resulting in data corruptions. The goal of this paper is to understand the impact of SSD-related data corruptions on the behaviors of complex HPC applications. To this end, we propose FFIS, a FUSE-based fault injection framework that systematically introduces storage faults into the application layer to model the errors originated from SSDs. FFIS is able to plant different I/O related faults into the data returned from underlying file systems, which also enables the investigation on the error resilience characteristics of the scientific file format for the first time. We demonstrate the use of FFIS with three representative real HPC applications, show how each application reacts to the data corruptions, and provide insights on the error resilience of the widely-adopted HDF5 file format for the HPC applications.

Fang, Bo↗

SimpleSSD: Modeling Solid State Drives for Holistic System Simulation

Existing solid state drive (SSD) simulators unfortunately lack hardware and/or software architecture models. Consequently, they are far from capturing the critical features of contemporary SSD devices. More importantly, while the performance of modern systems that adopt SSDs can vary based on their numerous internal design parameters and storage-level configurations, a full system simulation with traditional SSD models often requires unreasonably long runtimes and excessive computational resources. In this work, we propose SimpleSSD, a high-fidelity simulator that models all detailed characteristics of hardware and software, while simplifying the nondescript features of storage internals. In contrast to existing SSD simulators, SimpleSSD can easily be integrated into publicly-available full system simulators. Here, in addition, it can accommodate a complete storage stack and evaluate the performance of SSDs along with diverse memory technologies and microarchitectures. Thus, it facilitates simulations that explore the full design space at different levels of system abstraction.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-112: Intensity-Based Pulmonary Image Registration: An Evaluation Study

Purpose: Accurate alignment of thoracic CT images is essential for dose tracking and to safely implement adaptive radiotherapy in lung cancers. At the same time it is challenging given the highly elastic nature of lung tissue deformations. The objective of this study was to assess the performances of three state-of-art intensity-based algorithms in terms of their ability to register thoracic CT images subject to affine, barrel, and sinusoid transformation. Methods: Intensity similarity measures of the evaluated algorithms contained sum-of-squared difference (SSD), local mutual information (LMI), and residual complexity (RC). Five thoracic CT scans obtained from the EMPIRE10 challenge database were included and served as reference images. Each CT dataset was distorted by realistic affine, barrel, and sinusoid transformations. Registration performances of the three algorithms were evaluated for each distortion type in terms of intensity root mean square error (IRMSE) between the reference and registered images in the lung regions. Results: For affine distortions, the three algorithms differed significantly in registration of thoracic images both visually and nominally in terms of IRMSE with a mean of 0.011 for SSD, 0.039 for RC, and 0.026 for LMI (p<0.01; Kruskal-Wallis test). For barrel distortion, the three algorithms showed nominally no significant difference in terms of IRMSE with a mean of 0.026 for SSD, 0.086 for RC, and 0.054 for LMI (p=0.16) . A significant difference was seen for sinusoid distorted thoracic CT data with mean lung IRMSE of 0.039 for SSD, 0.092 for RC, and 0.035 for LMI (p=0.02). Conclusion: Pulmonary deformations might vary to a large extent in nature in a daily clinical setting due to factors ranging from anatomy variations to respiratory motion to image quality. It can be appreciated from the results of the present study that the suitability of application of a particular algorithm for pulmonary image registration is deformation-dependent.

60 APPLIED LIFE SCIENCES↗

SU-E-T-31: A Fast Finite Size Pencil Beam (FSPB) Convolution Algorithm for a New Co-60 Arc Therapy Machine

Purpose: Present a fast Finite Size Pencil Beam (FSPB) convolution algorithm for a new Co-60 arc therapy machine. The FSPB algorithm accounts for (i) strong angular divergence (short SAD), (ii) heterogeneity effect for primary attenuation, and (iii) source energy spectrum. Methods: The FSPB algorithm is based on a 0.5×0.5-cm2 dose kernel calculated using the GEPTS (Gamma Electron and Positron Transport System) Monte Carlo code. The dose kernel is tabulated using a thin XYZ mesh (0.1 mm steps in lateral directions) for radius less than 1 cm and using an RZ mesh (with varying steps) for larger radial distance. To account for SSD effect, 11 dose kernels with SSDs varying between 30 cm to 80 cm are calculated. Maynord factor and “lateral stretching” are applied to account for differences between closest and actual SSD. Appropriate rotations and second order interpolation are used to calculate the dose from a given beamlet to a point. Results: Accuracy: Dose distributions in water with 80 cm SSD are calculated using the new FSPB convolution algorithm and full Monte Carlo simulation (gold standard). Figs 1–4 show excellent agreements between FSPB and Monte Carlo calculations for different field sizes and at different depths. The dose distribution for a prostate case is calculated using FSPB (Fig.5). Sixty conformal beams with rectum blocking are assumed. Figs 6–8 show the comparison with Monte Carlo simulation based on the same beam apertures. The excellent agreement demonstrates the accuracy of the new algorithm in handling SSD variation, oblique incidence, and scatter contribution.Speed: The FSPB convolution algorithm calculates 28 million dose points per second using a single 2.2-GHz CPU. The present algorithm is seven times faster than a similar algorithm from Gu et al. (Phys. Med. Biol. 54, 2009, 6287–6297). Conclusion: A fast and accurate FSPB convolution algorithm was developed and benchmarked.

60 APPLIED LIFE SCIENCES↗

SU-E-T-185: Clinically-Relevant Investigation of Flattening Filter Free Skin Dose

Purpose: Flattening-filter-free (FFF) beams are increasingly used for small-field treatments due to inherent advantages like higher MU efficiency and reduced treatment time and scatter dose. Removal of the flattening-filter increases the electron contamination and low-energy x-rays. As such, surface-dose characteristics are different from traditional flattened (FF) beams. The goal of this work is to investigate surface dose of 6/10 MV FFF and FF beams under conditions representative of emerging complex techniques like small-field stereotactic treatments which use small fields formed with multi-leaf-collimators (MLCs) at closer SSDs. Methods: A parallel-plate PTW Markus-chamber (N23343) placed in custom air- and water-equivalent phantoms was used to measure surface-dose at 2/3/4/6/8/10/20/30 cm{sup 2} field sizes, at 80/90/100 cm source-to-surface distances, and at fields defined by jaws and MLCs. The effect of dose rate (600 and 1400/2400 MU/min) was also investigated at 100 cm SSD. Measurements were performed on TrueBeam linac (Varian Medical Systems, Palo Alto, CA) for 6X/6XFFF/10X/10XFFF beam energies. Results: No dose-rate dependence was seen for FFF skin-dose. Air-phantom measurements were, on average, 5±3% larger than for water-phantom measurements. With SSD increase from 80 to 100 cm, skin-dose decreased by an average of 3.9±2.5%. FFF beams were found to be more sensitive to SSD changes in comparison to FF beams. The difference in skin dose between MLC- and jaw-fields was less variable with field size for FFF compared to FF beams. 10 MV beams showed greater difference in FFF-to-FF ratio, 50% (jaws) and 22% (MLC), between the largest and smallest field sizes compared to 6 MV beams, 30% (jaws) and 9% (MLC). Conclusion: Under clinically-relevant conditions, surface dose for FFF beams was higher at small field size (<10 cm), lower at largest field size (30 cm), more sensitive to SSD changes, and had less variation with field size compared to dose for FF beams.

60 APPLIED LIFE SCIENCES↗

MO-FG-204-02: Reference Image Selection in the Presence of Multiple Scan Realizations

Purpose: Fusing information from multiple correlated realizations (e.g., 4DCT) can improve image quality. This process often involves ill-conditioned and asymmetric nonlinear registration and the proper selection of a reference image is important. This work proposes to examine post-registration variation indirectly for such selection, and develops further insights to reduce the number of cross-registrations needed. Methods: We consider each individual scan as a noisy point in the vicinity of an image manifold, related by motion. Nonrigid registration “transports” a scan along the manifold to the reference neighborhood, and the residual is a surrogate for local variation. To test this conjecture, 10 thoracic scans from the same session were reconstructed from a recently developed low-dose helical 4DCT protocol. Pairwise registration was repeated bi-directionally (81 times) and fusion was performed with each candidate reference. The fused image quality was assessed with SNR and CNR. Registration residuals in SSD, harmonic energy, and deformation Jacobian behavior were examined. The semi-symmetry is further utilized to reduce the number of registration needed. Results: The comparison of image quality between single image and fused ones identified reduction of local intensity variance as the major contributor of image quality, boosting SNR and CNR by 5 to 7 folds. This observation further suggests the criticality of good agreement across post-registration images. Triangle inequality on the SSD metric provides a proficient upper-bound and surrogate on such disagreement. Empirical observation also confirms that fused images with high residual SSD have lower SNR and CNR than the ones with low or intermediate SSDs. Registration SSD is structurally close enough to symmetry for reduced computation. Conclusion: Registration residual is shown to be a good predictor of post-fusion image quality and can be used to identify good reference centers. Semi-symmetry of the registration residual further reduces computation cost. Supported by in part by NIH R01 CA096679.

60 APPLIED LIFE SCIENCES↗

Cherenkov imaging method for rapid optimization of clinical treatment geometry in total skin electron beam therapy

Purpose: A method was developed utilizing Cherenkov imaging for rapid and thorough determination of the two gantry angles that produce the most uniform treatment plane during dual-field total skin electron beam therapy (TSET). Methods: Cherenkov imaging was implemented to gather 2D measurements of relative surface dose from 6 MeV electron beams on a white polyethylene sheet. An intensified charge-coupled device camera time-gated to the Linac was used for Cherenkov emission imaging at sixty-two different gantry angles (1° increments, from 239.5° to 300.5°). Following a modified Stanford TSET technique, which uses two fields per patient position for full body coverage, composite images were created as the sum of two beam images on the sheet; each angle pair was evaluated for minimum variation across the patient region of interest. Cherenkov versus dose correlation was verified with ionization chamber measurements. The process was repeated at source to surface distance (SSD) = 441, 370.5, and 300 cm to determine optimal angle spread for varying room geometries. In addition, three patients receiving TSET using a modified Stanford six-dual field technique with 6 MeV electron beams at SSD = 441 cm were imaged during treatment. Results: As in previous studies, Cherenkov intensity was shown to directly correlate with dose for homogenous flat phantoms (R{sup 2} = 0.93), making Cherenkov imaging an appropriate candidate to assess and optimize TSET setup geometry. This method provided dense 2D images allowing 1891 possible treatment geometries to be comprehensively analyzed from one data set of 62 single images. Gantry angles historically used for TSET at their institution were 255.5° and 284.5° at SSD = 441 cm; however, the angles optimized for maximum homogeneity were found to be 252.5° and 287.5° (+6° increase in angle spread). Ionization chamber measurements confirmed improvement in dose homogeneity across the treatment field from a range of 24.4% at the initial angles, to only 9.8% with the angles optimized. A linear relationship between angle spread and SSD was observed, ranging from 35° at 441 cm, to 39° at 300 cm, with no significant variation in percent-depth dose at midline (R{sup 2} = 0.998). For patient studies, factors influencing in vivo correlation between Cherenkov intensity and measured surface dose are still being investigated. Conclusions: Cherenkov intensity correlates to relative dose measured at depth of maximum dose in a uniform, flat phantom. Imaging of phantoms can thus be used to analyze and optimize TSET treatment geometry more extensively and rapidly than thermoluminescent dosimeters or ionization chambers. This work suggests that there could be an expanded role for Cherenkov imaging as a tool to efficiently improve treatment protocols and as a potential verification tool for routine monitoring of unique patient treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-66: Characteristics of Electron Beams From Varian Trubeam

Purpose: The purpose of this study was to compare the electron beam data between Truebeam and 2300ix Varian accelerators for percent depth dose for broad beam and small circular cutouts, cone factors, head scatter factor as a function of cone size and SSD, phantom scatter factor, blocking factor, distance factor and virtual source position. Methods: Measurements were performed for Truebeam and 2300ix Varian accelerators. The main energies used were: 6, 9, 12, 16 and 20 MeV. PDD was measured at SSD = 100 cm for open beam and small circular cutouts (r = 0.5, 1.0, 1.5, 2.0, 3.0, 4.0 and 6.6cm) for different energies. Measurements to determine the head scatter factor (H) were done as a function of radius for six representative energies and five cone sizes (6, 10, 15, 20 and 25cm2). The phantom scatter factor (PSF) is defined as the ratio of blocking factor in water at reference depth and head scatter factor in air. PSF was measured as a function of radius and electron energy. Distance factor was measured for all energies and cones for three SSD’s (100, 110 and 120cm). Results: The percent depth dose (PDD) was measured for small cutouts of radius r = 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 and 5.6cm. Blocking factor (BF) was measured for Truebeam and 2300ix accelerators, for different circular cutouts and energies for a 10×10 cone. Cone factors were compared between the two accelerators for different energies and applicator sizes. Conclusion: Cone factors measured for the two accelerator types differ by up to 5% for the largest applicator size. Blocking factors differs by up to 3%, with the largest variation for the smallest field size (0.5cm). Distance factor for different SSD’s differ by up to 4.5%.

43 PARTICLE ACCELERATORS↗

SU-F-T-533: Study of Dosimetric Properties of Cadmium Free Alloy Used in Compensator Based IMRT

Purpose: To study the dosimetric properties of cadmium free alloy which is used in compensator based IMRT. Methods: A mixture of 30% of lead,52% of bismuth and 18% of tin was used to prepare alloy. We prepared slabs of different thicknesses ranging from 0.71 cm to 6.14 cm. Density of alloy was measured by Archimedes’ principle using SI-234 Denver instrument and water as buoyant liquid. Transmission, linear attenuation coefficient (µ), tissue phantom ration (TPR), beam hardening, surface dose (Ds), percentage depth dose (PDD) and effect of scatter were measured and analyze for different field size and different thickness of compensator for 6 MV photon beam. Measurements were carried out at 100 cm SSD and 160 cm SSD. Results: Density of alloy was found to be 9.5456 gm/cm3. Melting point of alloy is 90–95 °C. For a field size of 10×10 cm2 µ was 0.4253 cm-1 at 100 cm SSD. Calculated TPR was found to be within 3 % of measured TPR. Ds was found to be decreasing with increasing thickness of compensator. 1cm, 1.98 cm and 4.16 cm thick compensator slab decreased surface dose by 4.2%, 6.1% and 9.5% respectively for a field size of 10×10cm2 at 100 cm SSD. As field size increases Ds increases for a given compensator thickness. This is due to increase in amount of scattered dose from wider collimator opening. For smaller field size, PDDs are increased from 3.0% to 5.5% of open beam PDDs as compensator thickness increases from 1 cm to 6.14 cm at a depth of 10 cm in water. For larger field size variation in PDDs is not significant. Conclusion: High degree of modulation can be achieved from this compensator material, which is essential in compensator based IMRT. Dosimetric properties analyzed in this study establish this alloy as a reliable, cost effective, reusable compensator material.

60 APPLIED LIFE SCIENCES↗

Uniform irradiation of adjustable target spots in high-power laser driver

For smoothing and shaping the on-target laser patterns flexibly in high-power laser drivers, a scheme has been developed that includes a zoom lens array and two-dimensional smoothing by spectral dispersion (SSD). The size of the target pattern can be controlled handily by adjusting the focal length of the zoom lens array, while the profile of the pattern can be shaped by fine tuning the distance between the target and the focal plane of the principal focusing lens. High-frequency stripes inside the pattern caused by beamlet interference are wiped off by spectral dispersion. Detailed simulations indicate that SSD works somewhat differently for spots of different sizes. For small spots, SSD mainly smooths the intensity modulation of low-to-middle spatial frequency, while for large spots, SSD sweeps the fine speckle structure to reduce nonuniformity of middle-to-high frequency. Spatial spectra of the target patterns are given and their uniformity is evaluated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Construction of Prototype Lightweight Mirrors

This contract and the work described was in support of a Seven Segment Demonstrator (SSD) and demonstration of a different technology for construction of lightweight mirrors. The objectives of the SSD were to demonstrate functionality and performance of a seven segment prototype array of hexagonal mirrors and supporting electromechanical components which address design issues critical to space optics deployed in large space based telescopes for astronomy and for optics used in spaced based optical communications systems. The SSD was intended to demonstrate technologies which can support the following capabilities; Transportation in dense packaging to existing launcher payload envelopes, then deployable on orbit to form space telescope with large aperture. Provide very large (less than 10 meters) primary reflectors of low mass and cost. Demonstrate the capability to form a segmented primary or quaternary mirror into a quasi-continuous surface with individual subapertures phased so that near diffraction limited imaging in the visible wavelength region is achieved. Continuous compensation of optical wavefront due to perturbations caused by imperfections, natural disturbances, and equipment induced vibrations/deflections to provide near diffraction limited imaging performance in the visible wavelength region. Demonstrate the feasibility of fabricating such systems with reduced mass and cost compared to past approaches. While the SSD could not be expected to satisfy all of the above capabilities, the intent was to start identifying and understanding new technologies that might be applicable to these goals.

Robinson, William G.↗

Adaptive Full Aperture Wavefront Sensor Study

This grant and the work described was in support of a Seven Segment Demonstrator (SSD) and review of wavefront sensing techniques proposed by the Government and Contractors for the Next Generation Space Telescope (NGST) Program. A team developed the SSD concept. For completeness, some of the information included in this report has also been included in the final report of a follow-on contract (H-27657D) entitled "Construction of Prototype Lightweight Mirrors". The original purpose of this GTRI study was to investigate how various wavefront sensing techniques might be most effectively employed with large (greater than 10 meter) aperture space based telescopes used for commercial and scientific purposes. However, due to changes in the scope of the work performed on this grant and in light of the initial studies completed for the NGST program, only a portion of this report addresses wavefront sensing techniques. The wavefront sensing techniques proposed by the Government and Contractors for the NGST were summarized in proposals and briefing materials developed by three study teams including NASA Goddard Space Flight Center, TRW, and Lockheed-Martin. In this report, GTRI reviews these approaches and makes recommendations concerning the approaches. The objectives of the SSD were to demonstrate functionality and performance of a seven segment prototype array of hexagonal mirrors and supporting electromechanical components which address design issues critical to space optics deployed in large space based telescopes for astronomy and for optics used in spaced based optical communications systems. The SSD was intended to demonstrate technologies which can support the following capabilities: Transportation in dense packaging to existing launcher payload envelopes, then deployable on orbit to form a space telescope with large aperture. Provide very large (greater than 10 meters) primary reflectors of low mass and cost. Demonstrate the capability to form a segmented primary or quaternary mirror into a quasi-continuous surface with individual subapertures phased so that near diffraction limited imaging in the visible wavelength region is achieved. Continuous compensation of optical wavefront due to perturbations caused by imperfections, natural disturbances, and equipment induced vibrations/deflections to provide near diffraction limited imaging performance in the visible wavelength region. Demonstrate the feasibility of fabricating such systems with reduced mass and cost compared to past approaches.

Robinson, William G.↗

Harmonia: A Globally Coordinated Garbage Collector for Arrays of Solid-state Drives

Solid-State Drives (SSDs) offer significant performance improvements over hard disk drives (HDD) on a number of workloads. The frequency of garbage collection (GC) activity is directly correlated with the pattern, frequency, and volume of write requests, and scheduling of GC is controlled by logic internal to the SSD. SSDs can exhibit significant performance degradations when garbage collection (GC) conflicts with an ongoing I/O request stream. When using SSDs in a RAID array, the lack of coordination of the local GC processes amplifies these performance degradations. No RAID controller or SSD available today has the technology to overcome this limitation. This paper presents Harmonia, a Global Garbage Collection (GGC) mechanism to improve response times and reduce performance variability for a RAID array of SSDs. Our proposal includes a high-level design of SSD-aware RAID controller and GGC-capable SSD devices, as well as algorithms to coordinate the global GC cycles. Our simulations show that this design improves response time and reduces performance variability for a wide variety of enterprise workloads. For bursty, write dominant workloads response time was improved by 69% while performance variability was reduced by 71%.

99 GENERAL AND MISCELLANEOUS↗