Search NASA⌕ Search

SEARCH · Search NASA

Results for “STORAGE UNIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Impacts of Control, Penetration, and Distribution of Embedded Storage Network in Bulk Power System

The current shift in generation mix from fossil fuel plants towards variable and intermittent renewable energy sources is poised to create a future grid with reduced physical inertia and mismatch between generation and demand. Embedded storage, which is a concept of a coordinated network of storage units sited at the interface between the transmission and distribution system, is proposed as a mechanism to provide a buffer between generation and demand. This paper proposes an automated framework to model and integrate embedded storage in large-scale power systems with industry-grade grid-following (GFL) and grid-forming (GFM) control technologies. More importantly, the developed framework is used to explore the impacts of embedded storage control, penetration, location, and capacity in providing fast frequency response to the grid under contingency events such as generator trips and faults. The framework and study are conducted using the transient-stability simulation tool PSS/E and a realistic model of the Puerto Rico grid as a chosen test system. The simulation results show that GFL and GFM embedded storage, distributed throughout the system, with sufficient penetration and capacity, can effectively improve primary frequency response of the system under the studied contingency events.

Battery Energy Storage, embedded storage, grid-for↗

Transient performance evaluation of an integrated heat pipe-thermal storage system

Transient performance tests of an integrated heat pipe-thermal storage system have been conducted. This system was developed as a part of an Organic Rankine Cycle-Solar Dynamic Power System receiver for future power systems. The integrated system consists of potassium heat pipe elements that incorporate thermal energy storage canisters within the vapor space and an organic fluid (toluene) heater tube used as the condenser region of the heat pipe. The transient performance tests determined the operating characteristics and power input limits of the integrated heat pipe-thermal storage unit under conditions corresponding to re-acquisition of the sun during emergence from eclipse conditions and to the initial start-up of the solar dynamic power system. The tests demonstrated that the heat pipe-thermal storage element is not limited under conditions corresponding to emergence from eclipse during normal orbital operations and the heat pipe will successfully start-up from the frozen condition with full input power at the onset. Details of the test procedures and results of the tests are presented in this paper.

Keddy, E.↗

Thermal energy storage using large hollow steel ingots

High temperature thermal energy storage (to 500 C = 930 F) using hollow steel ingots is investigated. Preliminary studies indicate that the system should be reliable, be characterized by low operation and maintenance costs, and be associated with low development risk. The estimated installed system energy unit storage cost is $13.50/kWh-t.

Turner, R. H.↗

Equipment Procurement and Final Design for the MARVEL High-Grade Heat Extraction System (HGHES)

This summer I worked on the design of a high-grade heat extraction system (HGHES) of the MARVEL Project. The MARVEL project at INL is a first-of-a-kind terrestrial microreactor to help provide a test platform to demonstrate the use of a microreactor to end customers and enable technology developers to test enabling microreactor technologies with a functional nuclear reactor. One of the project's main requirements is the reactors’ ability to deliver high-grade thermal power to end users, both for industrial and commercial use. The project required communication with multiple vendors for custom-made equipment, working with a high-temperature and high-pressure helium coolant system, and research of a Thermal Storage Unit (TSU).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fuel-Cell-Powered Vehicle with Hybrid Power Management

Figure 1 depicts a hybrid electric utility vehicle that is powered by hydrogenburning proton-exchange-membrane (PEM) fuel cells operating in conjunction with a metal hydride hydrogen-storage unit. Unlike conventional hybrid electric vehicles, this vehicle utilizes ultracapacitors, rather than batteries, for storing electric energy. This vehicle is a product of continuing efforts to develop the technological discipline known as hybrid power management (HPM), which is oriented toward integration of diverse electric energy-generating, energy-storing, and energy- consuming devices in optimal configurations. Instances of HPM were reported in five prior NASA Tech Briefs articles, though not explicitly labeled as HPM in the first three articles: "Ultracapacitors Store Energy in a Hybrid Electric Vehicle" (LEW-16876), Vol. 24, No. 4 (April 2000), page 63; "Photovoltaic Power Station With Ultracapacitors for Storage" (LEW- 17177), Vol. 27, No. 8 (August 2003), page 38; "Flasher Powered by Photovoltaic Cells and Ultracapacitors" (LEW-17246), Vol. 27, No. 10 (October 2003), page 37; "Hybrid Power Management" (LEW-17520), Vol. 29, No. 12 (December 2005), page 35; and "Ultracapacitor-Powered Cordless Drill" (LEW-18116-1), Vol. 31, No. 8 (August 2007), page 34. To recapitulate from the cited prior articles: The use of ultracapacitors as energy- storage devices lies at the heart of HPM. An ultracapacitor is an electrochemical energy-storage device, but unlike in a conventional rechargeable electrochemical cell or battery, chemical reactions do not take place during operation. Instead, energy is stored electrostatically at an electrode/electrolyte interface. The capacitance per unit volume of an ultracapacitor is much greater than that of a conventional capacitor because its electrodes have much greater surface area per unit volume and the separation between the electrodes is much smaller.

Eichenberg, Dennis J.↗

Cyber-Resilient Frequency Control of Power Grids with Energy Storage Systems

The integration of synchronous generators and energy storage systems operated through communication networks introduces new challenges and vulnerabilities to the electric grid, where cyber attacks can corrupt sensor measurements or control inputs and interrupt functions such as frequency regulation. This paper proposes a defense methodology for the design of resilient operating constraints imposed on each generation and storage unit in order to prevent any attack sequence from driving the system's frequency to unsafe conditions. The resilient operating constraints are found by using ellipsoidal approximations of the reachable set of the power system, leading to a convex optimization problem with linear matrix inequalities. Numerical results in a single-area power system with synchronous generation and energy storage demonstrate how the resilient constraints provide security guarantees against any type of attack affecting frequency measurements or controller setpoints.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mineralogy and reactive fluid chemistry evolution of hydraulically fractured Caney shale of Southern Oklahoma

Here, this study investigates geochemical rock-fluid interactions as a potential cause of rapid loss of permeability and productivity in hydraulically fractured shale reservoirs. It also interrogates the effects of these reactions in transforming depleted shale reservoirs into impermeable carbon storage units. The study employs batch reactor experiments where rock-powder samples are reacted with field fracturing fluid under reservoir temperature (95°C).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coordinated Frequency Regulation in Grid-Forming Storage Network via Safety-Consensus

Inverter-based storages are poised to play a prominent role in future power grid with massive renewable generation. Grid-forming inverters (GFMs) are emerging as a dominant technology with synchronous generators (SG)-like characteristics through primary control loops. Advanced secondary-layer control schemes, e.g., consensus algorithms, allow GFM-interfaced storage units to participate in frequency regulations and restore nominal frequency following grid disturbances. However, it is imperative to ensure critical frequency safety limits are not violated while the grid transitions from pre- to post-disturbance operating point. This paper presents a novel safety-enforced consensus method, having three distinct objectives: safe transient frequency evolution, minimizing frequency deviation, and coordinated power sharing. The proposed technique is illustrated using a GFM-interfaced grid-wide storage network on the IEEE 68-bus system under multiple grid transient scenarios.

consensus control↗

Comparative Analysis of Model Predictive Control and MPC-Informed Rule-Based Control for Thermal Storage Operation in Ultra-Low Temperature 4th Generation District Heating Networks

The integration of thermal storage and heat pumps in district heating networks (DHNs) can significantly enhance operational flexibility and energy efficiency; however, the practical deployment of advanced control strategies is often hindered by forecasting requirements and computational complexity. This study presents a comparative analysis of thermal storage control strategies in an ultra-low-temperature fourth-generation DHN, focusing on the development of a simplified rule-based control (RBC) explicitly informed by Model Predictive Control (MPC) behavior. The proposed methodology systematically analyzes the charging and discharging decisions of an MPC-controlled system under ideal forecasting conditions and extracts recurrent control patterns as a function of key system variables, including outdoor temperature, thermal demand, and electricity price. These patterns are translated into a set of structured time- and condition-based rules, resulting in an MPC-informed RBC that embeds predictive insights while preserving implementation simplicity and operational transparency. The approach is validated on a realistic mixed-use urban district in Denver, Colorado, USA, equipped with a centralized air-source heat pump, distributed water-to-water heat pumps, and a central thermal storage unit. Results show that the tuned RBC attains approximately 96% of ideal MPC economic performance (-27% of costs), preserves values of technical and environmental indicators (reduction only of 2-3%), and substantially reduces complexity. Sensitivity analyses further demonstrate the robustness of the RBC under varying operational conditions (i.e., ambient temperature, electricity price). Overall, the study demonstrates that MPC-informed rule-based control represents an effective trade-off between control performance and real-world applicability, enabling the integration of additional system components while maintaining simplicity, robustness, and ease of implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-temperature thermal storage systems for advanced solar receivers materials selections

Advanced space power systems that use solar energy and Brayton or Stirling heat engines require thermal energy storage (TES) systems to operate continuously through periods of shade. The receiver storage units, key elements in both Brayton and Stirling systems, are designed to use the latent heat of fusion of phase-change materials (PCMs). The power systems under current consideration for near-future National Aeronautics and Space Administration space missions require working fluid temperatures in the 1100 to 1400 K range. The PCMs under current investigation that gave liquid temperatures within this range are the fluoride family of salts. However, these salts have low thermal conductivity, which causes large temperature gradients in the storage systems. Improvements can be obtained, however, with the use of thermal conductivity enhancements or metallic PCMs. In fact, if suitable containment materials can be found, the use of metallic PCMs would virtually eliminate the orbit associated temperature variations in TES systems. The high thermal conductivity and generally low volume change on melting of germanium and alloys based on silicon make them attractive for storage of thermal energy in space power systems. An approach to solving the containment problem, involving both chemical and physical compatibility, preparation of NiSi/NiSi2, and initial results for containment of germanium and NiSi/NiSi2, are presented.

Wilson, D. F.↗

Micro-Environmental Control System (Final Report)

This project developed an innovative micro-environmental control system (µX) that enables office buildings to reduce energy used for heating and cooling by 15% or more. The µX is a compact, quiet, and ergonomic device that is designed to be installed under an office workstation; it is designed to maintain occupant comfort when room thermostat setpoints are incremented by 4°F or more (warmer in the summer and cooler in the winter) to save energy. When ambient room temperatures are outside of the usual comfort range, the µX maintains occupant comfort by delivering personalized cooling or heating locally to each office worker. The µX provides personalized cooling using a micro vapor compression system that includes a new high-performance micro-scroll compressor and a novel thermal storage unit. The vapor compression system operates at night to freeze a phase-change material (PCM). During the workday, the cooling stored in the PCM is released as a cool breeze of air to make occupants more comfortable. The micro-scroll compressor was developed specifically for this application; it is smaller than any of its type, minimizing the amount of power needed. In heating mode, the µX maintains occupant comfort using a foot heating mat with an infrared reflective box. The µX R&D project was conducted by Syracuse University in collaboration with United Technologies Research Center, Air Innovations, Bush Technical, and Cornell University. Over the course of the initial three-year project, the team developed and evaluated four versions of the unit, advancing the concept to Technology Readiness Level 6. The capabilities of individual proof-of-concept prototypes were verified in tests that were conducted with: 1) units in psychrometric chambers, 2) an instrumented manikin in a laboratory, and 3) human subjects in laboratories that simulate office environments. The tests verified that the µX prototypes met or exceeded all performance targets required to enable office buildings to reduce energy used for heating and cooling by 15% or more by maintaining occupant comfort when thermostat setpoints are incremented by 4°F or more.

25 ENERGY STORAGE↗

Low-power anisotropic molecular electronic memristors

A molecular electronic memristor, programmable resistive memory device, promises to revolutionize next-generation flexible data storage units, offering fast, dense and ultralow power solutions. Here we report anisotropic resistive switching in molecular κ-(BEDT-TTF) 2 Cu[N(CN) 2 ]Cl memristors, consisting of alternatively segregated bis(ethylenedithio)tetrathiafulvalene (BEDT-TTF) and Cu[N(CN) 2 ]Cl layers. Electron resistance switching behavior controlled by charge tunneling in molecular memristors show a low set voltage of 0.5 V (10 V/cm) with the ON/OFF ratio of 2.3×10 3 along a-axis and a high-level endurance of 1.25×10 4 cycles along all axes. Finally, the findings of such molecular electronic crystals promise for low-power data storage memristors.

36 MATERIALS SCIENCE↗

Identification of Faults Susceptible to Induced Seismicity Final Report

The primary objective of this project (referred to as the State of Stress project or SoS project) was to predict the presence of faults susceptible to movement in the presence of fluid injection as a consequence of vertical pressure migration from the storage unit to the crystalline basement. These faults included those difficult to resolve with traditional interpretations of surface seismic: faults with no or minimal offset, faults in the crystalline basement where no seismic reflectors are present, subseismic faults (due to size), and faults undetected (e.g., due to unfavorable orientation with surface seismic survey).

25 ENERGY STORAGE↗

Design and implementation of I/O performance prediction scheme on HPC systems through large-scale log analysis

Abstract Large-scale high performance computing (HPC) systems typically consist of many thousands of CPUs and storage units used by hundreds to thousands of users simultaneously. Applications from large numbers of users have diverse characteristics, such as varying computation, communication, memory, and I/O intensity. A good understanding of the performance characteristics of each user application is important for job scheduling and resource provisioning. Among these performance characteristics, I/O performance is becoming increasingly important as data sizes rapidly increase and large-scale applications, such as simulation and model training, are widely adopted. However, predicting I/O performance is difficult because I/O systems are shared among all users and involve many layers of software and hardware stack, including the application, network interconnect, operating system, file system, and storage devices. Furthermore, updates to these layers and changes in system management policy can significantly alter the I/O behavior of applications and the entire system. To improve the prediction of the I/O performance on HPC systems, we propose integrating information from several different system logs and developing a regression-based approach to predict the I/O performance. Our proposed scheme can dynamically select the most relevant features from the log entries using various feature selection algorithms and scoring functions, and can automatically select the regression algorithm with the best accuracy for the prediction task. The evaluation results show that our proposed scheme can predict the write performance with up to 90% prediction accuracy and the read performance with up to 99% prediction accuracy using the real logs from the Cori supercomputer system at NERSC.

97 MATHEMATICS AND COMPUTING↗

A Comprehensive Review on the Development of Solid–State Metal–Air Batteries Operated on Oxide–Ion Chemistry

The recently developed solid oxide metal–air redox battery (SOMARB) operating on oxide-ion chemistry represents an emerging and promising energy storage technology, which is well suited for managing grid stability and efficiently harvesting renewable energy. Compared to widely reported metal–air batteries operating on liquid-phase alkali-ion or alkaline chemistries, the SOMARB uniquely features a direct reduction of the high concentration of O 2 molecules in the gas phase without invoking the detrimental formation of a diffusion-blocking oxide phase on the surface of the oxygen electrode. A typical SOMARB is composed of a reversible solid oxide cell (RSOC) and an energy storage unit (ESU), which is capable of storing a high capacity of energy at high power without safety concerns. In this article, the SOMARB concept birth and development are reviewed and discussed with the fundamental differences separating it from other types of metal–air batteries, along with the challenges and opportunities around commercialization. Particular focus is placed on the functional materials tailored for ESU and RSOC applications, including recent experimental and computational efforts to boost the redox activity of Fe-based ESU materials and the performance of intermediate temperature RSOCs. Lastly, candid opinions are offered on the challenges and opportunities facing the future development of SOMARBs toward large-scale energy storage applications.

08 HYDROGEN↗

Supply chain optimization of sustainable aviation fuel from carinata in the Southeastern United States

We report carinata is a purpose-grown oilseed feedstock for renewable fuels, including sustainable aviation fuel (SAF) that can replace conventional aviation fuel (CAF). Given carinata is a new crop in the Southeastern United States, it is crucial to analyze its sustainability from a supply chain perspective. This study developed a mixed-integer linear programming (MILP) model and simulated it for 20 years, starting from a farm (county-level data) and ending at the airport. About 2.06 million ha in Alabama, Florida, and Georgia combined were found suitable for carinata production. Given the three-year rotation period, about 0.69 million hectares can be cultivated annually, approximately 65% of which was in Georgia. About 2.4% of the combined SAF annual demand of four major airports (about 210 thousand t) in the study area is satisfied at that level of carinata cultivation. However, all available SAF was supplied to the Atlanta airport as this decision minimizes the supply chain cost. A total of 1343 storage units, one oil extraction mill, and one biorefinery were needed to meet the overall demand. We found that SW Georgia is the top supplier of carinata seeds. The unit cost of production and carbon intensity were estimated to be $\$$0.89 L -1 (or $\$$26.79 GJ -1 ) and 0.91 kg CO 2 e L -1 (or 27.28 kg CO 2 e GJ -1 ), respectively. This carbon intensity of carinata-based SAF was 67.8% lower than that of CAF. With variations included in SAF demand, yield, and soil carbon sequestration, carbon savings remained between 66.5% and 67.8%. Given the GHG advantage of SAF over CAF, there is justification for subsidies required to make SAF competitive.

10 SYNTHETIC FUELS↗

The Peaking Potential of Long-Duration Energy Storage in the United States Power System

In this work, we investigated the peaking potential for storage with durations of 4 h up to durations of 168 h (1 week). The peaking potential for a given storage duration is the amount of storage that can be added to a power system before that storage can no longer serve the peak net demand period at full rated capacity. We found that for the United States, 168 h of storage would be sufficient to serve about 27 % of peak demand, or about 215 GW in the current system. However, more than one-half of this amount could be served by storage with 12 h or less of capacity. As deployment of wind and solar grows, the peaking potential increases significantly, and under decarbonization scenarios, approximately one-half of the peak demand could be served by storage of up to 168 h; but again, the majority of this storage could be with durations of up to 12 h. The potential is also driven by the mix of wind and solar, and by storage efficiency, with the deployment of solar having the largest impact for both storage peaking potential and the mix of durations.

capacity expansion↗

Challenges of designing, operating, and managing brine extraction at a carbon dioxide storage site

Developing and deploying commercial-scale carbon dioxide (CO 2 ) storage at a site requires operational strategies to manage pressure and CO 2 plume distribution. In the natural gas storage and oil and gas industries, fluid extraction has been successfully implemented as a strategy to manage pressure and control fluid distribution (i.e., hydrocarbon recovery and natural gas storage efficiency, respectively). The technical challenges of integrating brine extraction at CO 2 storage sites are expected to be similar, if not identical, to those in the natural gas storage and petroleum industries. Major technical challenges of using brine extraction to manage storage in a storage unit include (1) designing and completing the brine extraction wells, (2) locating the brine extraction well, (3) assessing the efficacy of brine extraction, and (4) handling the extracted brine. The design and completion of the brine extraction well include the well type (i.e., vertical or horizontal) and perforated interval. The location of the well is influenced by the timing of extraction operations (i.e., prior or after CO 2 injection starts) and project objectives (i.e., desired directional movement of the CO 2 plume and avoid or minimize CO 2 extraction). The efficacy of brine extraction requires a baseline projection of the pressure and CO 2 plume distribution. Options for handling extracted brine include subsurface disposal, surface disposal, and industrial use. Here this paper addresses means of overcoming technical challenges that may likely be encountered before or after CO 2 injection starts.

25 ENERGY STORAGE↗