Search NASASearch

SEARCH · Search NASA

Results for “STRESS MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development and calibration of buried wire gages for wall shear stress measurements in fluid flow

Special methods were developed to arrange 'Buried Wire Gage' inserts flush to the contoured flow surfaces of instrument plugs of a boundary-layer flow apparatus. The fabrication process was aimed at producing proper bonding of the sensor wire to the substrate surface, without causing excessive surface waviness. A large number of gages were built and first calibrated for the resistance-temperature characteristics. The gages were then installed in a flow calibration apparatus and operated from a constant temperature anemometer system for a series of flow settings to derive the calibration constants of each of the gages. The flow settings included a range of subsonic freestream Mach numbers in order to help establish the gage calibration characteristics for compressible flow fields. This paper provides a description of the buried wire gage technique, an explanation of the method evolved for making proper gages, the procedure for calibrating the gages and the results of measurements performed for determining the calibration constants.

Murthy, Sreedhara V.

Stress Measurements on Blair High School Gymnasium: A Demonstration of Space Technology Transfer

This Report describes an actual demonstration of transfer to non-space use of technologies developed for space programs applications. Techniques used in assessing static and dynamic characteristics of the Blair High School gymnasium involved data acquisition by continuous scanning of strain gauge data acquired over a time of wide-temperature range, and analysis by a computer routine developed by Jet Propulsion Laboratory five years ago. The advantage of this method over conventional structural testing of uniquely designed structures was proved. More importantly, the process of demonstration was shown to be of great assistance to, and extension of, normal methods of disseminating information of new technologies. It is felt that significant benefit will derive from this improved mode oi concept transfer.

Kastel, Dean

Utilizing Non-Contact Stress Measurement System (NSMS) as a Health Monitor

Continuously monitor all 156 blades throughout the entire operating envelope without adversely affecting tunnel conditions or compromise compressor shell integrity, Calculate dynamic response and identify the frequency/mode to determine individual blade deflection amplitudes, natural frequencies, phase, and damping (Q), Log static deflection to build a database of deflection values at certain compressor conditions to use as basis for real-time online Blade Stack monitor, Monitor for stall, surge, flutter, and blade damage, Operate with limited user input, low maintenance cost, safe illumination of probes, easy probe replacement, and require little or no access to compressor.

Hayes, Terry

Correlation of predicted and measured thermal stresses on an advanced aircraft structure with similar materials

A laboratory heating test simulating hypersonic heating was conducted on a heat-sink type structure to provide basic thermal stress measurements. Six NASTRAN models utilizing various combinations of bar, shear panel, membrane, and plate elements were used to develop calculated thermal stresses. Thermal stresses were also calculated using a beam model. For a given temperature distribution there was very little variation in NASTRAN calculated thermal stresses when element types were interchanged for a given grid system. Thermal stresses calculated for the beam model compared similarly to the values obtained for the NASTRAN models. Calculated thermal stresses compared generally well to laboratory measured thermal stresses. A discrepancy of signifiance occurred between the measured and predicted thermal stresses in the skin areas. A minor anomaly in the laboratory skin heating uniformity resulted in inadequate temperature input data for the structural models.

Jenkins, J. M.

X-Ray Diffraction Measurements of Residual Stress in a Cold Sprayed Ni Coating

X-ray diffraction (XRD) was used to investigate the residual stress in a cold sprayed Ni coating which failed to form a bimetallic joint with NASA HR-1. The objective was to apply pure Ni by cold spray as a diffusion barrier between the Ni-based alloy NASA HR-1 and the Cu-based GRCop-42 for a thrust cell assembly. After additive manufacturing of the GRCop-42 cylinder, the commercially pure Ni coating was cold sprayed onto the cylinder. It was intended to have NASA HR-1 applied directly onto the Ni coating by Directed Energy Deposition (DED), however the bond failed during the first layer of DED. Residual stress measurements were collected via the Sin²ψ method in three equally spaced locations on the top surface of the Ni coating in both as-cold sprayed and heat-treated conditions. The results revealed both compressive and tension stresses on the as-cold sprayed sample and compressive stresses in the heat-treated sample. The results were illuminated when plotted at their respective positions and with their respective orientation angles around a circle. This showed rotational symmetry in the residual stress measurements, which correlated to the processing method used during application of the Ni coating.

Laura Wilson

Stress dependence of ultrasonic velocity in unidirectional graphite/epoxy composites for longitudinal waves propagating along the direction of stress

Measurements of stress-induced velocity changes for propagation along the direction of applied stress in graphite/epoxy composites are presented. A linear relation between normalized velocity shift and stress is demonstrated for propagation and stress direction perpendicular to the fiber direction. The ratio of the SAC to the elastic compliance for this loading direction was assessed and found to have a value similar to that of numerous other materials which have very different linear elastic properties. Measurements with stress and propagation along the fibers yielded unusual behavior; the curves were very nonlinear and even shifted direction at higher loads.

Prosser, William H.

Comparison of Measured and Calculated Stresses in Built-up Beams

Web stresses and flange stresses were measured in three built-up beams: one of constant depth with flanges of constant cross-section, one linearly tapered in depth with flanges of constant cross section, and one linearly tapered in depth with tapered flanges. The measured stresses were compared with the calculated stresses obtained by the methods outlined in order to determine the degree of accuracy that may be expected from the stress analysis formulas. These comparisons indicated that the average measured stresses for all points in the central section of the beams did not exceed the average calculated stresses by more than 5 percent. It also indicated that the difference between average measured flange stresses and average calculated flange stresses on the net area and a fully effective web did not exceed 6.1 percent.

Levin, L Ross

Method for measuring biaxial stress in a body subjected to stress inducing loads

A method is described for measuring stress in test articles including the steps of obtaining for a calibrating specimen a series of transit time differentials between the second wave echo for a longitudinal wave and the first wave echo for each of a pair of shear waves propagated through the specimen as it is subjected to known stress load of a series of stress loads for thus establishing a series of indications of the magnitudes for stress loads induced in the specimen, and thereafter obtaining a transit time differential between the second wave echo for a longitudinal wave and the first wave echo for each of a pair of shear waves propagated in the planes of the stress axes of a test article and comparing the transit time differential thus obtained to the series of transit time differentials obtained for the specimen to determine the magnitude of biaxial stress in the test article.

Clotfelter, W. N.

Fiber Creep Evaluation by Stress Relaxation Measurements

A simple bend stress relaxation (BSR) test has been used to measure the creep related properties of a chemically vapor-deposited SiC fiber. Time, temperature, and strain dependent BSR data were analyzed to ascertain the ability of the stress relaxation results to predict tensile creep as a function of the same parameters. The predictions compared very well to actual creep data obtained by axial measurements, indicating that the BSR test could be used for determining both creep and stress relaxation of polycrystalline ceramic fibers under tensile loading.

Morscher, Gregory N.

Development of buried wire gages for measurement of wall shear stress in Blastane experiments

Buried Wire Gages operated from a Constant Temperature Anemometer System are among the special types of instrumentation to be used in the Boundary Layer Apparatus for Subsonic and Transonic flow Affected by Noise Environment (BLASTANE). These Gages are of a new type and need to be adapted for specific applications. Methods were developed to fabricate Gage inserts and mount those in the BLASTANE Instrumentation Plugs. A large number of Gages were prepared and operated from a Constant Temperature Anemometer System to derive some of the calibration constants for application to fluid-flow wall shear-stress measurements. The final stage of the calibration was defined, but could not be accomplished because of non-availability of a suitable flow simulating apparatus. This report provides a description of the Buried Wire Gage technique, an explanation of the method evolved for making proper Gages and the calibration constants, namely Temperature Coefficient of Resistance and Conduction Loss Factor.

Murthy, S. V.

Ultrasonics used to measure residual stress

Ultrasonic method is used to measure residual stress in metal structures. By using this method, various forms of wave propagation in metals are possible, and more thorough analysis of complex geometric structures may be had.

Source record