Search NASA⌕ Search

SEARCH · Search NASA

Results for “SUSPECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Reader agreement and accuracy of ultrasound features for hepatic steatosis

Purpose: The purpose of the study is to assess the reader agreement and accuracy of eight ultrasound imaging features for classifying hepatic steatosis in adults with known or suspected hepatic steatosis. Methods: This was an IRB-approved, HIPAA-compliant prospective study of adult patients with known or suspected hepatic steatosis. All patients signed written informed consent. Ultrasound images (Siemens S3000, 6C1HD, and 4C1 transducers) were acquired by experienced sonographers following a standard protocol. Eight readers independently graded eight features and their overall impression of hepatic steatosis on ordinal scales using an electronic case report form. Duplicated images from the 6C1HD transducer were read twice to assess intra-reader agreement. Intra-reader, inter-transducer, and inter-reader agreement were assessed using intraclass correlation coefficients (ICC). Features with the highest intra-reader agreement were selected as predictors for dichotomized histological steatosis using Classification and Regression Tree (CART) analysis, and the accuracy of the decision rule was compared to the accuracy of the radiologists’ overall impression. Results: 45 patients (18 males, 27 females; mean age 56 ± 12 years) scanned from September 2015 to July 2016 were included. Mean intra-reader ICCs ranged from 0.430 to 0.777, inter-transducer ICCs ranged from 0.228 to 0.640, and inter-reader ICCs ranged from 0.014 to 0.561. The CART decision rule selected only large hepatic vein blurring and achieved similar accuracy to the overall impression (74% to 75% and 68% to 72%, respectively). Conclusions: Large hepatic vein blurring, liver–kidney contrast, and overall impression provided the highest reader agreement. Large hepatic vein blurring may provide the highest classification accuracy for dichotomized grading of hepatic steatosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrasound versus computed tomography for the detection of ureteral calculi in the pediatric population: a clinical effectiveness study

Objective: To determine the diagnostic performance of ultrasound for diagnosing ureteral calculi in children using a clinical effectiveness approach. Methods: Billing records and imaging reports were used to identify children (≤ 18 years old) evaluated for suspected urolithiasis using ultrasound between March 2012 and March 2017. Patients without unenhanced CT within 24 h (reference standard) were excluded. Imaging (ultrasound and CT) reports were reviewed for presence, number, size, and location of calculi. Diagnostic performance of ultrasound (versus CT) was calculated on an individual ureter basis both by direct calculus visualization as well as direct visualization combined with suspected presence of ureteral stone based on indirect ultrasound findings. Results: 41 ureteral calculi were present in 38 of 69 (55.1%) patients. Mean patient age was 14.7 ± 3.6 years, and 35 of 69 (51%) patients were boys. Based on direct calculus visualization, ultrasound had a sensitivity of 12.8% (95% CI 5.6–26.7%), specificity of 100% (95% CI 96.3–100%), positive predictive value (PPV) of 100% (95% CI 56.6–100%), and negative predictive value (NPV) of 74.4% (95% CI 66.4–81.1%). When ultrasound examinations reported as suspicious for ureteral calculi based on indirect findings also were considered positive, ultrasound had a sensitivity of 41.0% (95% CI 27.1–56.6%), specificity of 95.0% (95% CI 88.7–97.8%), PPV of 76.2% (95% CI 54.9–89.4%), and NPV of 80.3% (95% CI 72.2–86.5%). Conclusions: In clinical practice, ultrasound has low sensitivity for directly visualizing ureteral calculi subsequently identified by CT, although sensitivity improves when considering suspicious examinations as positive.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Molecular Imaging of Cardiac Amyloidosis

Purpose of Review: The aim of this review is to give an update on the molecular imaging tools currently available as well as to discuss the potential roles and limitations of molecular imaging in cardiac amyloidosis. Recent Findings: Molecular imaging plays a central role in the evaluation of patients with suspected cardiac amyloidosis. It can be used to diagnose and distinguish between the different types of cardiac amyloidosis. The diagnostic properties of bone scintigraphy are such that it allows reliable diagnosis of transthyretin cardiac amyloidosis without the need of endomyocardial biopsy in a significant proportion of patients. Furthermore, molecular tracers assessing amyloid plaque burden and sympathetic innervation may be useful for the non-invasive evaluation diagnosis and risk stratification of patients with suspected cardiac amyloidosis. Summary: Cardiac amyloidosis is an under-recognized cause of left ventricular hypertrophy and heart failure in the elderly. The role of molecular imaging in cardiac amyloidosis is expected to grow considering the arrival of new therapies and molecular imaging probes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A multifunctional CT technology: Reality or illusion for patient risk assessment?

A high-speed, multi-slice coronary computed tomography (CT) imaging has emerged as a promising or clinically available multifunctional technique for the assessment of myocardial ischemia, viability, ischemia-induced cardiac dysfunction, and coronary atherosclerotic alterations in patients with suspected or known coronary artery disease. Despite several technical issues remain to be resolved, cardiac CT imaging will have a reality as a multifunctional modality for guiding physicians in better decision-making for favorable clinical outcomes in patients with suspected coronary artery disease, provided that this imaging technology can contribute to characterization and localization of high-risk coronary atherosclerosis in combination with the quantitative evaluation of functional myocardial ischemia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}F-FDG-PET in Finnish patients with clinical suspicion of cardiac sarcoidosis: Female sex and history of atrioventricular block increase the prevalence of positive PET findings

Introduction: Fluorodeoxyglucose positron emission tomography (FDG-PET) is a non-invasive imaging modality that has been shown to be a feasible method to demonstrate myocardial inflammation. The aim of this study was to identify the patients suspected of having cardiac sarcoidosis (CS), who are most likely to benefit from PET imaging. Materials and methods: 137 patients suspected of having CS underwent a dedicated cardiac FDG-PET examination at Tampere University Hospital between August 2012 and September 2015. These examinations were retrospectively analyzed. Results: 33 and 12 of the 137 patients had abnormal left and right ventricular (LV and RV) FDG-uptake, respectively. Abnormal LV-uptake and RV-uptake were significantly associated with female sex and a history of advanced AV-block (P < 0.05). Abnormal RV-uptake was also associated with ventricular tachycardia and atrial fibrillation (P < 0.05). 56% of the 27 female patients with a history of AV-block had a pathological PET finding compared to only 6% of the 49 male patients without a history of AV-block. There were 17 female patients with history of both AV-block and ventricular tachycardia, 71% of them had abnormal PET finding. Conclusions: Abnormal FDG-PET findings were associated with female sex, AV-block, and arrhythmias in this clinical cohort.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of acute myocarditis by cardiac magnetic resonance imaging: Comparison of qualitative and quantitative analysis methods

Background: To compare cardiac magnetic resonance (CMR) qualitative and quantitative analysis methods for the noninvasive assessment of myocardial inflammation in patients with suspected acute myocarditis (AM). Methods: A total of 61 patients with suspected AM underwent coronary angiography and CMR. Qualitative analysis was performed applying Lake-Louise Criteria (LLC), followed by quantitative analysis based on the evaluation of edema ratio (ER) and global relative enhancement (RE). Diagnostic performance was assessed for each method by measuring the area under the curves (AUC) of the receiver operating characteristic analyses. The final diagnosis of AM was based on symptoms and signs suggestive of cardiac disease, evidence of myocardial injury as defined by electrocardiogram changes, elevated troponin I, exclusion of coronary artery disease by coronary angiography, and clinical and echocardiographic follow-up at 3 months after admission to the chest pain unit. Results: In all patients, coronary angiography did not show significant coronary artery stenosis. Troponin I levels and creatine kinase were higher in patients with AM compared to those without (both P < .001). There were no significant differences among LLC, T2-weighted short inversion time inversion recovery (STIR) sequences, early (EGE), and late (LGE) gadolinium-enhancement sequences for diagnosis of AM. The AUC for qualitative (T2-weighted STIR 0.92, EGE 0.87 and LGE 0.88) and quantitative (ER 0.89 and global RE 0.80) analyses were also similar. Conclusions: Qualitative and quantitative CMR analysis methods show similar diagnostic accuracy for the diagnosis of AM. These findings suggest that a simplified approach using a shortened CMR protocol including only T2-weighted STIR sequences might be useful to rule out AM in patients with acute coronary syndrome and normal coronary angiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser spot welding of additive manufactured 304L stainless steel

Here, the goal of this work is to understand if an additively manufactured 304L stainless steel exhibits similar spot-welding behavior as wrought 304L stainless steel. Due to the many differences between an additively manufactured component and wrought product, it is important to determine how the material interacts with the laser and how it affects the weld bead morphology. In this paper, the laser coupling efficiency, weld size, and solidification of spot welds produced in wrought and additively manufactured 304L stainless steel were investigated. The coupling efficiency of wrought and additively manufactured 304L stainless steel of similar surface condition were approximately the same over a range of applied laser energies. Laser welding of the untreated (rougher) surface of additively manufactured 304L, however, showed improved coupling efficiency ranging between 3.3 and 100%. The rougher surface traps the incoming light and increases the coupling efficiency at lower laser energies, while at higher energy, the absorption efficiency is dominated by intrinsic absorption from the keyhole formation rather than surface roughness. The resulting spot weld microstructures differed from welds made in wrought 304L and additively manufactured 304L. Welds made in wrought 304L were fully austenitic containing what is suspected to be massive austenite, which suggests that these welds solidified as primary ferrite. Welds made in additively manufactured 304L were also fully austenitic and contained both cellular austenite and what is suspected to be massive austenite. These observations mean that welds made in additively manufactured 304L solidified as primary ferrite and primary austenite. The differences in weld microstructures made in wrought and AM 304L can be attributed to differences in the composition and solidification rate.

304L stainless steel↗

Detection of nuclear testing from surface concentration measurements: Analysis of radioxenon from the February 2013 underground test in North Korea

A method is outlined and tested to detect low level nuclear or chemical sources from time series of concentration measurements. The method uses a mesoscale atmospheric model to simulate the concentration signature from a known or suspected source at a receptor which is then regressed successively against segments of the measurement series to create time series of metrics that measure the goodness of fit between the signatures and the measurement segments. The method was applied to radioxenon data from the Comprehensive Test Ban Treaty (CTBT) collection site in Ussuriysk, Russia (RN58) after the Democratic People's Republic of Korea (North Korea) underground nuclear test on February 12, 2013 near Punggye. The metrics were found to be a good screening tool to locate data segments with a strong likelihood of origin from Punggye, especially when multiplied together to a determine the joint probability. Metrics from RN58 were also used to find the probability that activity measured in February and April of 2013 originated from the Feb 12 test. A detailed analysis of an RN58 data segment from April 3/4, 2013 was also carried out for a grid of source locations around Punggye and identified Punggye as the most likely point of origin. Thus, the results support the strong possibility that radioxenon was emitted from the test site at various times in April and was detected intermittently at RN58, depending on the wind direction. The method does not locate unsuspected sources, but instead, evaluates the probability of a source at a specified location. However, it can be extended to include a set of suspected sources. Extension of the method to higher resolution data sets, arbitrary sampling, and time-varying sources is discussed along with a path to evaluate uncertainty in the calculated probabilities.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Associations of urinary cadmium with circulating sex hormone levels in pre- and postmenopausal Japanese women

Background: Exposure to cadmium has been suspected as a risk factor for breast cancer. The present study examined the associations between urinary cadmium levels and circulating sex hormone levels that are linked to breast cancer risk in healthy women. Methods: The study subjects were 396 premenopausal Japanese women who had regular menstrual cycles less than 40 days long and 207 postmenopausal Japanese women. Urinary cadmium was measured using spot urine samples. Plasma estradiol, testosterone, and dehydroepiandrosterone sulfate were measured. Additionally, the follicle-stimulating hormone, luteinizing hormone, and sex hormone-binding globulin were measured for premenopausal women. Results: In premenopausal women, the urinary cadmium level either expressed in μg per liter or per g of urine creatinine was significantly inversely associated with total and free testosterone levels after controlling for age, body mass index, smoking status, alcohol intake, and the phase of the menstrual cycle. Total and free testosterone levels were 14.6% and 15.0% lower, respectively, in women in the highest quartile of urinary cadmium per g creatinine in those in the lowest quartile. In postmenopausal women, the urinary cadmium in μg per liter as well as per g creatinine was significantly inversely associated with the estradiol level after controlling for covariates. The estradiol level was 25.8% lower in women in the highest tertile of urinary cadmium per g creatinine than in those in the lowest tertile. Conclusions: The data suggest inverse associations between urinary cadmium and the plasma estradiol or testosterone level in Japanese women. - Highlights: • Exposure to cadmium has been suspected as a risk factor for breast cancer. • Urinary cadmium and plasma sex-hormone levels were measured in Japanese women. • Urinary cadmium was inversely associated with testosterone in premenopausal women. • Urinary cadmium was inversely associated with estradiol in postmenopausal women.

60 APPLIED LIFE SCIENCES↗

Modulation of oxidative phosphorylation (OXPHOS) by radiation- induced biophotons

Highlights: • This paper provides evidence that the biophoton signals known to be emitted by irradiated cells, interfere with the processes of oxidative phosphorylation (OXPHOS) in cells receiving the signals. • The paper demonstrates that Complex 1 activity is completely supressed by these biophotons resulting in downstream compromise of ATP production. • The mechanism may help explain fatigue and immune compromise effects of low dose exposure to ionising radiation. Radiation-induced biophotons are an electromagnetic form of bystander signalling. In human cells, biophoton signalling is capable of eliciting effects in non-irradiated bystander cells. However, the mechanisms by which the biophotons interact and act upon the bystander cells are not clearly understood. Mitochondrial energy production and ROS are known to be involved but the precise interactions are not known. To address this question, we have investigated the effect of biophoton emission upon the function of the complexes of oxidative phosphorylation (OXPHOS). The exposure of bystander HCT116 p53 +/+ cells to biophoton signals emitted from β-irradiated HCT116 p53 +/+ cells induced significant modifications in the activity of Complex I (NADH dehydrogenase or NADH:ubiquinone oxidoreductase) such that the activity was severely diminished compared to non-irradiated controls. The enzymatic assay showed that the efficiency of NADH oxidation to NAD+ was severely compromised. It is suspected that this impairment may be linked to the photoabsorption of biophotons in the blue wavelength range (492–455 nm). The photobiomodulation to Complex I was suspected to contribute greatly to the inefficiency of ATP synthase function since it resulted in a lower quantity of H{sup +} ions to be available for use in the process of chemiosmosis. Other reactions of the ETC were not significantly impacted. Overall, these results provide evidence for a link between biophoton emission and biomodulation of the mitochondrial ATP synthesis process. However, there are many aspects of biological modulation by radiation-induced biophotons which will require further elucidation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Focal Salvage Guided by T{sub 2}-Weighted and Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Prostate Cancer Recurrences

Purpose: Salvage treatment of the entire prostate for local recurrent cancer after primary radiotherapy is associated with high toxicity rates. Our goal was to show that, using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for the visualization of a recurrence, focal salvage treatment can be performed, with, potentially, a reduction in toxicity. Methods and Materials: We performed MRI, including a DCE sequence, in 7 patients with biopsy-proven locally recurrent prostate cancer. The specific regions of interest suspect for containing tumor were delineated using DCE and T{sub 2}-weighted MRI scans. Subsequently, focal salvage high-dose-rate brachytherapy plans were created to illustrate the principle of focal salvage. Total salvage treatment plans were also created for comparison. Results: The transfer constant (K{sup trans}) values from the DCE were 0.33-0.67 min{sup -1} for areas suspect for tumor and 0.07-0.25 min{sup -1} for normal tissue. In 4 cases, a focal salvage plan could be generated; 93-100% of the gross tumor volume was covered with the prescribed dose, with relative sparing of the bladder, rectum, and urethra. In the total salvage plans, 24-53% of the gross tumor volume was covered, and the organs at risk received high doses. In 3 cases, a focal salvage plan could not be created because of multifocal tumor, seminal vesicle extension, or capsular extension. Conclusion: Focal salvage treatment plans can be created in patients with local recurrent prostate cancer after radiotherapy. DCE-MRI supports the localization of the target area. This could lead to less toxicity in patients with local recurrent prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Radiotherapy for Locally Advanced Non-Small-Cell Lung Cancer Does Not Underdose the Microscopic Disease and has the Potential to Increase Tumor Control

Purpose: To evaluate doses to the microscopic disease (MD) in adaptive radiotherapy (ART) for locally advanced non-small-cell lung cancer (NSCLC) and to model tumor control probability (TCP). Methods and Materials: In a retrospective planning study, three-dimensional conformal treatment plans for 13 patients with locally advanced NSCLC were adapted to shape and volume changes of the gross tumor volume (GTV) once or twice during conventionally fractionated radiotherapy with total doses of 66 Gy; doses in the ART plans were escalated using an iso-mean lung dose (MLD) approach compared to non-adapted treatment. Dose distributions to the volumes of suspect MD were simulated for a scenario with synchronous shrinkage of the MD and GTV and for a scenario of a stationary MD despite GTV shrinkage; simulations were performed using deformable image registration. TCP calculations considering doses to the GTV and MD were performed using three different models. Results: Coverage of the MD at 50 Gy was not compromised by ART. Coverage at 60 Gy in the scenario of a stationary MD was significantly reduced from 92% {+-} 10% to 73% {+-} 19% using ART; however, the coverage was restored by iso-MLD dose escalation. Dose distributions in the MD were sufficient to achieve a TCP >80% on average in all simulation experiments, with the clonogenic cell density the major factor influencing TCP. The combined TCP for the GTV and MD was 19.9% averaged over all patients and TCP models in non-adaptive treatment with 66 Gy. Iso-MLD dose escalation achieved by ART increased the overall TCP by absolute 6% (adapting plan once) and by 8.7% (adapting plan twice) on average. Absolute TCP values were significantly different between the TCP models; however, all TCP models suggested very similar TCP increase by using ART. Conclusions: Adaptation of radiotherapy to the shrinking GTV did not compromise dose coverage of volumes of suspect microscopic disease and has the potential to increase TCP by >40% compared with radiotherapy planning without ART.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Detection of Mucosal Recurrent Nasopharyngeal Carcinomas After Radiotherapy With Narrow-Band Imaging Endoscopy

Purpose: This study evaluated the feasibility of screening mucosal recurrent nasopharyngeal carcinoma with narrow-band imaging (NBI) endoscopy. Methods and Materials: One hundred and six patients were enrolled. All patients underwent conventional white-light (WL) endoscopic examination of the nasopharynx followed by NBI endoscopy. Biopsies were performed if recurrence was suspected. Results: We identified 32 suspected lesions by endoscopy in WL and/or NBI mode. Scattered brown spots (BS) were identified in 22 patients, and 4 of the 22 who had negative MRI findings were histopathologically confirmed to be neoplasias that were successfully removed via endoscopy. A comparison of the visualization in NBI closer view corresponded to histopathological findings in 22 BS, and the prevalence rates of neoplasias in tail signs, round signs, and irregularities signs were 0% (0/6), 0% (0/7), and 44.4% (4/9), respectively (p = 0.048). The sensitivity, specificity, and diagnostic capability were 37.5%, 92.9% and 0.652 for WL, 87.5%, 74.5% and 0.810 for NBI, and 87.5%, 87.8%, and 0.876 for NBI closer view, respectively. NBI closer view was effective in increasing specificity compared with NBI alone (87.8% vs. 74.5%, p < 0.05), and in increasing sensitivity and diagnostic capability compared to WL alone (87.5% vs. 37.5%, p < 0.05; 0.876 vs. 0.652, p = 0.0001). Conclusions: Although NBI in endoscopy can improve sensitivity of mucosal recurrent nasopharyngeal neoplasias, false-positive (nonneoplasia BS) results may be obtained in areas with nonspecific inflammatory changes due to postradiation effects. NBI closer view not only can offer a timely, convenient, and highly reliable assessment of mucosal recurrent nasopharyngeal carcinoma, it can also make endoscopic removal possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A 2011 Updated Systematic Review and Clinical Practice Guideline for the Management of Malignant Extradural Spinal Cord Compression

Purpose: To update the 2005 Cancer Care Ontario practice guidelines for the diagnosis and treatment of adult patients with a suspected or confirmed diagnosis of extradural malignant spinal cord compression (MESCC). Methods: A review and analysis of data published from January 2004 to May 2011. The systematic literature review included published randomized control trials (RCTs), systematic reviews, meta-analyses, and prospective/retrospective studies. Results: An RCT of radiation therapy (RT) with or without decompressive surgery showed improvements in pain, ambulatory ability, urinary continence, duration of continence, functional status, and overall survival. Two RCTs of RT (30 Gy in eight fractions vs. 16 Gy in two fractions; 16 Gy in two fractions vs. 8 Gy in one fraction) in patients with a poor prognosis showed no difference in ambulation, duration of ambulation, bladder function, pain response, in-field failure, and overall survival. Retrospective multicenter studies reported that protracted RT schedules in nonsurgical patients with a good prognosis improved local control but had no effect on functional or survival outcomes. Conclusions: If not medically contraindicated, steroids are recommended for any patient with neurologic deficits suspected or confirmed to have MESCC. Surgery should be considered for patients with a good prognosis who are medically and surgically operable. RT should be given to nonsurgical patients. For those with a poor prognosis, a single fraction of 8 Gy should be given; for those with a good prognosis, 30 Gy in 10 fractions could be considered. Patients should be followed up clinically and/or radiographically to determine whether a local relapse develops. Salvage therapies should be introduced before significant neurologic deficits occur.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The use of analgesics for intentional self-poisoning: Trends in U.S. poison center data

In the U.S., intentional self-poisonings with analgesics that are available without a prescription increased from 2000 to 2018. Given concerns regarding mental health outcomes during the COVID-19 pandemic, we examined and compared trends in pediatric and adult intentional self-poisoning with acetaminophen, aspirin, ibuprofen, and naproxen from 2016 to 2021 using the National Poison Data System (NPDS) to see if these trends have continued. We extracted annual case counts of all suspected suicide attempts from intentional poisoning, and of suspected suicide attempts resulting in major effects or death, from the NPDS for non-prescription single ingredient adult formulation acetaminophen, non-prescription single ingredient adult formulation aspirin, single ingredient formulation ibuprofen, and single ingredient formulation naproxen. We enumerated the cases by year, age, and gender. Most cases of intentional self-poisoning within the review period involved acetaminophen and ibuprofen and the 13–19-year-olds constituted the highest proportion of intentional self-poisoning cases across age groups for all four analgesics. Cases involving females predominated cases involving males by 3:1 or greater. Here, the 13–19-year-old age group also represented the largest proportion of cases that resulted in major clinical effects or deaths. An increasing trend in suicide poisoning cases with acetaminophen and ibuprofen was observed in the 6-19-years age group and this trend appeared to exacerbate from 2020 to 2021 corresponding with the start of the COVID-19 pandemic period.

60 APPLIED LIFE SCIENCES↗

Aging behavior of an in-situ TiB{sub 2}/Al-Cu-Li-x matrix composite

Transmission electron microscopy, differential scanning calorimetry and hardness tests have been performed on an in-situ TiB{sub 2}/Al-3.3Cu-1.0Li-0.60Mg-0.40Ag-0.14Zr-0.13Si composite to study its aging behavior at 175 °C. A cubic phase suspected to be the σ (Al{sub 5}Cu{sub 6}Mg{sub 2}) phase or its variant is precipitated at all aging stages studied, and this phase is not typically observed in the Al-Cu-Li alloys. The primary hardening (aging for 3 h) phases consist of δ′ (Al{sub 3}Li), β′ (Al{sub 3}Zr) and the cubic phase. After aging for 18 h, all precipitates including T{sub 1} (Al{sub 2}CuLi), S (Al{sub 2}CuMg), θ′ (Al{sub 2}Cu), δ′, β′ and the cubic phase have appeared, and the formation of T{sub 1} and S results in a rapid increase in hardness. With prolonging of aging time, the apparent coarsening of T{sub 1} and S results in a decline in hardness. - Highlights: •The aging behavior of an in-situ TiB{sub 2}/Al-Cu-Li-x composite was studied. •A cubic phase suspected to be σ (Al{sub 5}Cu{sub 6}Mg{sub 2}) or its variant was precipitated. •The hardness change was dominated by the evolution of T{sub 1} (Al{sub 2}CuLi) and S (Al{sub 2}CuMg).

36 MATERIALS SCIENCE↗

VirtualToxLab — A platform for estimating the toxic potential of drugs, chemicals and natural products

The VirtualToxLab is an in silico technology for estimating the toxic potential (endocrine and metabolic disruption, some aspects of carcinogenicity and cardiotoxicity) of drugs, chemicals and natural products. The technology is based on an automated protocol that simulates and quantifies the binding of small molecules towards a series of proteins, known or suspected to trigger adverse effects. The toxic potential, a non-linear function ranging from 0.0 (none) to 1.0 (extreme), is derived from the individual binding affinities of a compound towards currently 16 target proteins: 10 nuclear receptors (androgen, estrogen α, estrogen β, glucocorticoid, liver X, mineralocorticoid, peroxisome proliferator-activated receptor γ, progesterone, thyroid α, and thyroid β), four members of the cytochrome P450 enzyme family (1A2, 2C9, 2D6, and 3A4), a cytosolic transcription factor (aryl hydrocarbon receptor) and a potassium ion channel (hERG). The interface to the technology allows building and uploading molecular structures, viewing and downloading results and, most importantly, rationalizing any prediction at the atomic level by interactively analyzing the binding mode of a compound with its target protein(s) in real-time 3D. The VirtualToxLab has been used to predict the toxic potential for over 2500 compounds: the results are posted on (http://www.virtualtoxlab.org). The free platform — the OpenVirtualToxLab — is accessible (in client–server mode) over the Internet. It is free of charge for universities, governmental agencies, regulatory bodies and non-profit organizations. -- Highlights: ► In silico technology for estimating the toxic potential of drugs and chemicals. ► Simulation of binding towards 16 proteins suspected to trigger adverse effects. ► Mechanistic interpretation and real-time 3D visualization. ► Accessible over the Internet. ► Free of charge for universities, governmental agencies, regulatory bodies and NPOs.

60 APPLIED LIFE SCIENCES↗