At least 73 records · Page 4

Frequency stabilization in injection controlled pulsed CO2 lasers

Longitudinal mode selection by injection has been demonstrated as a viable technique for tailoring a TEA-CO2 laser with pulse energies of a Joule or greater to fit the requirements of a coherent lidar transmitter. Once reliable generation of single-longitudinal-mode (SLM) pulses is obtained, one can study the intrapulse frequency variation and attempt to determine the sources of frequency sweeping, or chirp. These sources include the effect of the decaying plasma, the thermal gradient due to the energy dissipation associated with the laser mechanism itself, and the pressure shift of the center frequency of the laser transition. The use of the positive-branch unstable resonator as an efficient means of coupling a discharge with transverse spatial dimensions of the order of centimeters to an optical cavity mode introduces another concern: namely, what can be done to emphasize transverse mode discrimination in an unstable resonator cavity while maintaining high coupling efficiency. These issues are briefly discussed in the paper, and representative experimental examples are included.

Menzies, Robert T.

Swept group delay measurement

Direct recording of group delay measurements on a system under temperature and stress tests employs modulated carrier frequency sweep over an S or X band. Reference path and test paths to separate detectors utilize a power divider e.g., a directional coupler or a hybrid T junction. An initially balanced phase comparator is swept in frequency by modulated carrier over the band of interest for different conditions of temperature and/or mechanical stress to obtain characteristic group delay curves.

Trowbridge, D. L.

Single-stage electrohydraulic servosystem for actuating on airflow valve with frequencies to 500 hertz

An airflow valve and its electrohydraulic actuation servosystem are described. The servosystem uses a high-power, single-stage servovalve to obtain a dynamic response beyond that of systems designed with conventional two-stage servovalves. The electrohydraulic servosystem is analyzed and the limitations imposed on system performance by such nonlinearities as signal saturations and power limitations are discussed. Descriptions of the mechanical design concepts and developmental considerations are included. Dynamic data, in the form of sweep-frequency test results, are presented and comparison with analytical results obtained with an analog computer model is made.

Webb, J. A., Jr.

Gravitational radiation from rapidly rotating nascent neutron stars

We study the secular evolution and gravitational wave signature of a newly formed, rapidly rotating neutron star. The neutron star may arise from core collapse in a massive star or from the accretion-induced collapse of a white dwarf. After a brief dynamical phase, the nascent neutron star settles into an axisymmetric, secularly unstable state. Gravitational radiation drives the star to a nonaxisymmetric, stationary equilibrium configuration via the bar-mode instability. The emitted quasi-periodic gravitational waves have a unique signature: the wave frequency sweeps downward from a few hundred Hertz to zero, while the wave amplitude increase from zero to a maximum and then decays back to zero. Such a wave signal could detected by broadband gravitational wave interferometers currently being constructed. We also characterize two other types of gravitational wave signals that could arise in principle from a rapidly rotating, secularly unstable neutron star: a high-frequency (f greater than or approximately = 1000 Hz) wave which increases the pattern-speed of the star, and a wave that actually increases the angular momentum of the star.

Lai, Dong

Detecting isolated resonance curves using fixed frequency voltage control tests

Isolated resonance curves, or isolas, are resonance branches of the harmonically forced system that exist separately from the main nonlinear forced response curve, leading to excessive vibrations. Traditional stepped or swept sine simulations and tests rely on continuation along the frequency parameter, typically resulting in a jump phenomenon along the primary resonance branch, prior to the disconnected isola. The main objective of this research is to propose an approach to identify isolated resonance curves by performing continuation along the input amplitude that initializes the response from a low-amplitude solution in the linear regime. Furthermore, this is achieved with the open-loop fixed frequency voltage control method that continues along the shaker voltage parameter and measures the so-called S-curves, which are theoretically a continuous solution branch that connect to the isola. The methodology is demonstrated on a fixture-wing-pylon assembly with a vibro-impact nonlinearity localized in a pylon subcomponent attachment. Multi-harmonic balance simulations are deployed to compute both the nonlinear forced response curves and S-curves to demonstrate the isola detection strategy on a reduced-order finite element model of the nonlinear system. Swept sine and fixed frequency voltage control tests are then conducted on the physical structure to demonstrate the isola detection experimentally, revealing the existence of the large amplitude vibrations that are undetected in the forces levels and frequencies measured with traditional frequency sweeping.

Characterization and Analytical Technique

Synthesis of Submillimeter Radiation for Spectroscopy

The frequency-multiplier submillimeter spectrometer (FMSS) is a laboratory apparatus for far-infrared molecular spectroscopy, embodying several advances over prior such apparatuses. The most innovative part of the FMSS is a source of monochromatic submillimeter- wavelength radiation that can be tuned over a wide frequency range, as needed for trace gas analyses and molecular- structure studies for which such apparatuses are typically used. The radiation source features a modular design and is built mostly from commercially available components. It includes a computer-controlled radio-frequency synthesizer, amplifiers, and frequency multipliers of a type heretofore used in local oscillators for heterodyne far-infrared receivers. In conjunction with the rest of the apparatus, this source makes it possible to perform measurements over large portions of the submillimeter-wavelength spectrum with resolution, accuracy, and sensitivity greater than those achievable in Fourier-transform infrared spectroscopy. In comparison with prior laboratory submillimeter- wavelength radiation sources, this source is much lighter in weight, less cumbersome, less power-hungry, and capable of sustained operation with less intervention by laboratory personnel. Also, unlike some prior submillimeter-wavelength sources, this source does not require a high-voltage power source. As shown in more detail in the figure, the radiation source includes a sweep frequency synthesizer connected to an external waveform generator, the output of which is used as a reference signal. The synthesizer is computer-controlled through a standard general-purpose interface bus (GPIB) and is operated in phase-locked continuous- wave mode for all measurements. The synthesizer output ranges in frequency from 11 to 18 GHz. For suppression of frequency spurs and harmonics, the output of the frequency synthesizer is fed through a tunable yttrium iron garnet (YIG) filter, which is swept in frequency simultaneously with the frequency synthesizer.

Maiwald, Frank

A finite viscoelastic constitutive model for low to high strain rate response of elastomers with application of strain rate-induced glass transition

Amorphous elastomers exhibit significant rate-stiffening and unique viscous flow characteristics across a wide range of strain rates, often undergoing glass transition above a strain rate threshold. We have developed a thermodynamically-consistent and micromechanically-inspired constitutive model for soft elastomeric materials to capture the rate-dependent stress-strain behavior and hysteresis when subjected to low to high strain rates. Here, our proposed constitutive model encapsulates the viscous flow of materials through molecular motion at low strain rates and local rearrangement and alignment of the molecules trying to overcome the intermolecular resistance at high strain rates, essentially covering the glass transition. We applied our constitutive model to uniaxial compression experiments performed at low and high strain rates for polyborosiloxane (PBS) to identify the material parameters, and subsequently, performed numerical simulations of single and multi-cycle compression, stress relaxation, and small amplitude oscillatory tension-compression. Our analyses indicate that the model predicts higher total energy dissipation with increasing strain rate; however, dissipation associated with molecular relaxation decreases (forming a cusp) because, beyond a crossover strain rate, intermolecular rearrangement and alignment become dominant, which is consistent with the onset of the glass transition. For cyclic loading-unloading, we observed that dissipation over a cycle remains constant at low strain rates but decreases non-monotonically at high strain rates before becoming constant, with the peak stress over the cycle becoming higher, which can be interpreted as more loading being carried elastically by the polymer network as the intermolecular rearrangement process occurs. Additionally, our model was able to predict the qualitative nature of the storage modulus and loss modulus in the limit of small strain over a wide range of frequency sweeps.

36 MATERIALS SCIENCE

Vibration mitigation in interlocking metasurfaces

Interlocking metasurfaces (ILMs) are a new class of mechanical metamaterials with patterned surface features that enable joining of two adjacent bodies, serving as an alternative to welds, fasteners, or adhesives. While the strength of ILMs has been explored previously, it is also possible to envision ILMs that possess the ability to dampen vibration or tailor energy transmission across the interface. In this study, we explore the vibration transmission under frequency sweep and random excitation of three ILM designs. This is the first study to characterize the response of ILMs under vibration. We find that ILMs which are tightly coupled (e.g., small interference fit) behave as a linear system and depart only marginally from the behavior of a solid body. However, through strategic manipulation of the ILM topology, and in particular the fit clearances, we show that vibrations can be damped by over an order of magnitude. Design strategies to employ ILMs for vibration mitigation are developed using a first-order model.

Bolmin, O. [Carnegie Mellon Univ., Pittsburgh, PA

Broadband cross polarization for ultra-wideline magic-angle spinning NMR

Over the past decade, there has been a sustained interest in using frequency-swept (FS) pulses for the efficient acquisition of wideline and ultra-wideline (UW) NMR powder patterns. Such experiments are typically conducted under static conditions, employing both direct- and indirect-excitation methods (i.e., WCPMG and BRAIN-CP/WCPMG, respectively). Recently, Koppe et al. demonstrated that the WCPMG pulse sequence can be used to efficiently acquire wideline and UW NMR spectra with spinning sideband (SSB) manifolds under magic-angle spinning (MAS) conditions, capitalizing on the increased signal-to-noise ratios (SNR) afforded by MAS. To date, there have been only a few instances of broadband cross-polarization (CP) experiments using FS pulses under MAS conditions and no applications to systems exhibiting wideline and/or ultra-wideline powder patterns, despite the clear advantages these experiments could offer. Herein, we demonstrate that FS pulses selectively applied to a single sideband of the S spin can be used for efficient 1 H-S polarization transfer to S = 1/2 nuclides with large anisotropic chemical shift interactions at slow to moderate MAS rates. The Hartmann–Hahn matching conditions in BRAIN-CP/WCPMG-MAS experiments bear similarity to those of standard CP sequences, yet operate over UW frequency ranges and only require low-amplitude RF pulses on the S channel. Crucial to the success of the BRAIN-CP/WCPMG-MAS experiment is careful calibration of the RF amplitude, transmitter offset, and effective frequency sweep of the FS pulse applied to the S spins at a given MAS rate. Thus, by means of numerical simulations and experimental testing, we provide recommendations for the parameterization and setup of BRAIN-CP/WCPMG-MAS experiments for their most efficient use. Results showcasing the capability of the BRAIN-CP/WCPMG-MAS pulse sequence are presented, including applications to 119 Sn, 195 Pt, and 103 Rh NMR.

Kimball, James J. [Florida State University, Talla

Digital Filter Design for Point-on-Wave Sensors: Highlighting Frequency Response Limitations and Enhancing Grid Simulation Accuracy

Data is proving to be the backbone of today's and, more importantly, tomorrow's grid. As the system changes and introduces fast-acting devices like power electronics, overall observability tends to decrease from the utility point-of-view. This can be mitigated by adding more high-fidelity sensors onto the grid, although this incurs a cost. These sensors are never ideal, and each have unique frequency responses that may influence the data produced. This may, in turn, impact the protection and control of the power grid. This paper presents a methodology of representing these point-on-wave sensors digitally by estimating digital-filter representations of them, thereby introducing means of improving the sensor models used in electromagnetic-transient (EMT) simulations. This may help with identifying potential high-frequency, sensor-induced distortions, and system resonance compensation. Three commercial-grade medium-voltage point-on-wave sensors are utilized in a lab environment to obtain experimental frequency responses with a frequency sweep, and it is shown that both Infinite Impulse Response (IIR) and Finite Impulse Response (FIR) filter representations may approximate these responses with varying degrees of accuracy, though each has their own strengths and weaknesses. It is found that, in general, FIR estimation better approximates these sensors than IIR estimation does.

Wilson, Aaron [ORNL] (ORCID:0000000327331697)

Beam Synchronous for the Rest of Us!

Fermilab’s Tevatron Clock (TCLK) infrastructure has been an integral part of the accelerator control network since the 1980’s. This 10MHz Manchester encoded protocol has enabled flexible, real-time event distribution for thousands of devices connected to the timing network with a high degree of reliability. Forthcoming upgrades to the Fermilab complex (PIP-II, LBNF, ACORN) necessitate higher levels of precision to maintain inter-bunch timing for Instrumentation and Control purposes. This presents as an opportunity to refine the event distribution protocol for tighter synchronization between machines, experiments, and eventually far-site operations. This paper outlines a method by which beam-synchronous events may be distributed through asynchronous serial protocols via integration with local LLRF and global PPS reference signals. This method is ideal for synchrotron machines with aggressive frequency sweeps (such as Fermilab's 38~53MHz Booster) and allows for precision timing to be maintained across machines without specialized hardware.

43 PARTICLE ACCELERATORS

An evaluation of random analysis methods for the determination of panel damping

An analysis is made of steady-state and non-steady-state methods for the measurement of panel damping. Particular emphasis is placed on the use of random process techniques in conjunction with digital data reduction methods. The steady-state methods considered use the response power spectral density, response autocorrelation, excitation-response crosspower spectral density, or single-sided Fourier transform (SSFT) of the response autocorrelation function. Non-steady-state methods are associated mainly with the use of rapid frequency sweep excitation. Problems associated with the practical application of each method are evaluated with specific reference to the case of a panel exposed to a turbulent airflow, and two methods, the power spectral density and the single-sided Fourier transform methods, are selected as being the most suitable. These two methods are demonstrated experimentally, and it is shown that the power spectral density method is satisfactory under most conditions, provided that appropriate corrections are applied to account for filter bandwidth and background noise errors. Thus, the response power spectral density method is recommended for the measurement of the damping of panels exposed to a moving airflow.

Bhat, W. V.

Locations of solar radio bursts

Measurements of the positions of the sources of solar radio bursts at decameter wavelengths, 20- to 60-MHz range, provide information about physical conditions in a region of the corona extending from about one-half to several solar radii from the surface of the sun. Position measurements in the 20- to 60-MHz range were made with the Clark Lake sweep-frequency grating interferometer. Although the resolution of the instrument is sufficient to measure source position accurately, the highly variable effect of refraction in the earth's ionosphere severely limits the observations, distorting position determinations to such an extent as to make much of the position data useless unless ionospheric refraction can be taken into account. A method was developed for the removal of the refractive effect from the data to permit determination of true source position. With this technique it is considered possible to measure spatial extent of radio sources that will provide information about emission processes and physical parameters in the corona.

Fitzenreiter, R.

Effect of saturated frequency chirping on mode-locked laser pulses.

A dye-induced nonlinear frequency chirping is analytically shown to have significant modifications on the nature of the output mode-locked lasers. It is shown that the saturated frequency sweeping is responsible for substantial pulse broadening as well as substructures.

Kim, D. M.

Stimulation of the Harris instability in the ionosphere

Observations made with a sweep frequency rf sounder on the satellite ISIS 1 in the topside ionosphere are reported, and the interpretation of diffuse signals at the lower harmonics of the electron cyclotron frequency is discussed. These signals are attributed to the stimulation of Harris instabilities of longitudinal plasma waves at multiples of the cyclotron frequency in a single electron distribution. The Harris instability is excited most readily when the frequency is near the midpoint between the harmonics of the cyclotron frequency. The cause of these instabilities is the large electron velocity anisotropy which results from collisionless cyclotron damping of the energy from the high power sounder pulse.

Benson, R. F.

Modal test - Measurement and analysis requirements

Data from the Viking Orbiter Modal Test Program are used to illustrate modal test measurement and analysis requirements. The test was performed using a multiple shake dwell technique where data were acquired one channel at a time and recorded on paper tape. Up to ten shakers were used simultaneously, with a complete set of data consisting of 290 strain-gage readings and 125 accelerometer readings. The data analysis provided information sufficient to minimize errors in the data. The list of analyses in order of value is orthogonality, residual mass, frequency sweep, data checks to assure good test data, multilevel trends, global kinetic energy, and global strain energy.

Wada, B. K.