Search NASA⌕ Search

SEARCH · Search NASA

Results for “SYSTEM ADVISOR MODEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Understanding Solar Photovoltaic System Performance: An Assessment of 75 Federal Photovoltaic Systems

This report presents a performance analysis of 75 photovoltaic systems based on PV system production data collected as part of a FEMP Federal PV Performance Assessment project combined with co-incident insolation, and ambient temperature to analyze how actual performance compares with a performance model. FEMP collaborated with 17 Federal agencies and sub-agencies to collect the information required to analyze the performance of each system. The systems represent a total capacity of 30,714 kW and range in size from 1 kW to 4,043 kW, with an average size of 410 kW, and were installed between 2011 and 2020. The data is analyzed for Key Performance Indicators, Availability, Performance Ratio and Energy Ratio by comparing the measured production data to model production data. The System Advisor Model (SAM) combines a description of the system (such as inverter capacity, de-rating for temperature, balance-of-system efficiency) with environmental parameters (coincident solar and temperature data) to calculate predicted performance. The performance metrics are calculated by lining up the measured production data with the model estimate on an hour-by-hour, day-by-day, or month-by-month basis (depending on the interval resolution of the production data). A report with system description, photo of the system, special assumptions made for the site, graph of measured production and model production, table of key performance indicators, and links to O&M resources that might improve performance was produced and delivered to site and agency staff with a short on-line briefing.

14 SOLAR ENERGY↗

Bifacial Simulation in SAM

A bifacial irradiance model is introduced within the System Advisor Model (SAM). The modeling steps and implementation in SAM are presented. The results of a bifacial simulation are compared against several other modeling programs and shown to match within 1 - 2 percent for fixed-axis and horizontal single axis tracked systems. An example case study is presented to demonstrate how the model can be used to evaluate bifacial systems, with a variety of results presented to illustrate different sensitivities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SAM International Case Studies: DPV Analysis in Mexico

Presentation demonstrates the use of the System Advisor Model (SAM) in international analyses, specifically Mexico. Two analyses are discussed with relation to SAM modelling efforts: 1) Customer impacts from changes to net metering and billing agreements and 2) Potential benefits of PV for Mexican solar customers, the Mexican Treasury, and the environment. Along with the SAM analyses, integration of the International Utility Rate Database (I-URDB) with SAM and future international SAM work are discussed. Presentation was created for the International Solar Energy Society's (ISES) webinar titled 'International use of the NREL System Advisor Model (SAM) with case studies'.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technoeconomic Modeling of Battery Energy Storage in SAM

Detailed comprehensive lead-acid and lithium-ion battery models have been integrated with photovoltaic models in an effort to allow System Advisor Model (SAM) to offer the ability to predict the performance and economic benefit of behind the meter storage. In a system with storage, excess PV energy can be saved until later in the day when PV production has fallen, or until times of peak demand when it is more valuable. Complex dispatch strategies can be developed to leverage storage to reduce energy consumption or power demand based on the utility rate structure. This document describes the details of the battery performance and economic models in SAM.

14 SOLAR ENERGY↗

Performance Modeling and Testing of Distributed Electronics in PV Systems; NREL (National Renewable Energy Laboratory)

Computer modeling is able to predict the performance of distributed power electronics (microinverters, power optimizers) in PV systems. However, details about partial shade and other mismatch must be known in order to give the model accurate information to go on. This talk will describe recent updates in NREL’s System Advisor Model program to model partial shading losses with and without distributed power electronics, along with experimental validation results. Computer modeling is able to predict the performance of distributed power electronics (microinverters, power optimizers) in PV systems. However, details about partial shade and other mismatch must be known in order to give the model accurate information to go on. This talk will describe recent updates in NREL’s System Advisor Model program to model partial shading losses.

14 SOLAR ENERGY↗

Side-by-Side Comparison of Subhourly Clipping Models

Over the past several years there have been numerous attempts at quantifying the inherent power clipping of inverters due to sub-hourly irradiance variability that is not captured in hourly PV performance models. Different models have been proposed to correct for these clipping losses in PV performance estimates, including matrix lookup models, distribution modeling of the PV power performance within a given hour, and machine learning methods. To date, there have been few comprehensive quantitative comparisons of these inverter clipping correction modeling approaches to evaluate the effectiveness of these approaches in predicting the actual behavior of PV system inverter clipping. In this study, we perform such a comparison, evaluating the Allen and Walker correction loss modeling approaches recently implemented in the System Advisor Model (SAM) against clipping losses modeled with 1-minute climate data. These comparisons were performed across a variety of climate locations and inverter loading ratios to thoroughly analyze the effectiveness of these modeling approaches relative to each other. Results from this analysis reveal that both clipping correction approaches improve annual energy accuracy to within 2% of 1-minute modeled energy yield. The two models predict annual clipping loss more accurately than simple hourly power limit clipping, with the Allen method typically being slightly more accurate at typical ILR values and the Walker method often being slightly more accurate at high ILR values The models can improve accuracy over the status quo clipping approach up to 3 percentage points in systems with ILR of 2.0, showing the importance of this modeling factor in energy yield estimates.

ENERGY PLANNING, POLICY, AND ECONOMY,MATHEMATICS A↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Off-design performance of molten salt-driven Rankine cycles and its impact on the optimal dispatch of concentrating solar power systems

This paper presents a model for improving off-design performance predictions for molten salt-driven Rankine power cycles, such as in concentrating solar power tower applications. The model predicts cycle off-design performance under various boundary conditions, including molten salt inlet temperature, mass flow rate, and ambient temperature. The model is validated using industry performance data and benchmarked with results from the literature. A complete concentrating solar power plant, inclusive of solar heliostat field and receiver, is then considered, by implementing the Rankine cycle off-design performance results into the National Renewable Energy Laboratory’s System Advisor Model software, which includes a tool that determines optimal power production schedules. The work improves upon the current System Advisor Model by updating off-design performance characteristics. A case study demonstrates the impact of cycle off-design behavior on annual performance for a stand-alone concentrating solar power system and a concentrating solar power-photovoltaic hybrid system. In addition, we demonstrate how cycle off-design performance influences optimal operator dispatch decisions and, thereby, overall system design and economics. We conclude that off-design cycle performance impacts “optimal” sub-system sizing, especially for a concentrating solar power-photovoltaic hybrid configuration in which concentrating solar power must dispatch in conjunction with photovoltaic generation.

14 SOLAR ENERGY↗

Economic Analysis Case Studies of Battery Energy Storage with SAM

Interest in energy storage has continued to increase as states like California have introduced mandates and subsidies to spur adoption. This energy storage includes customer sited behind-the-meter storage coupled with photovoltaics (PV). This paper presents case study results from California and Tennessee, which were performed to assess the economic benefit of customer-installed systems. Different dispatch strategies, including manual scheduling and automated peak-shaving were explored to determine ideal ways to use the storage system to increase the system value and mitigate demand charges. Incentives, complex electric tariffs, and site specific load and PV data were used to perform detailed analysis. The analysis was performed using the free, publically available System Advisor Model (SAM) tool. We find that installation of photovoltaics with a lithium-ion battery system priced at $300/kWh in Los Angeles under a high demand charge utility rate structure and dispatched using perfect day-ahead forecasting yields a positive net-present value, while all other scenarios cost the customer more than the savings accrued. Different dispatch strategies, including manual scheduling and automated peak-shaving were explored to determine ideal ways to use the storage system to increase the system value and mitigate demand charges. Incentives, complex electric tariffs, and site specific load and PV data were used to perform detailed analysis. The analysis was performed using the free, publically available System Advisor Model (SAM) tool. We find that installation of photovoltaics with a lithium-ion battery system priced at $300/kWh in Los Angeles under a high demand charge utility rate structure and dispatched using perfect day-ahead forecasting yields a positive net-present value, while all other scenarios cost the customer more than the savings accrued.

14 SOLAR ENERGY↗

Hybrid Solar Thermal Energy System for District Heating Application

Solar district heating (SDH) systems can be good alternatives to conventional systems when they are optimized with hybrid configurations and thermal energy storage (TES). In this scope, a hybrid renewable thermal energy system (RTES) model has been built combining flat plate collector (FPC) solar system with parabolic trough collector (PTC) system via a heat exchanger and coupled with TES. To undertake the hybridization of the system, System Advisor Model (SAM) software was modified, which allowed control over configurations and more accurate modelling of heat transfer between the collectors. The model is first compared to an existing hybrid solar district heating systems (DHS) system in Taars, Denmark. The results showed a good correlation with an overestimation of only 6.4% compared to most recent heat output. Then the same system configuration was modeled in different geographic locations to investigate the impact of changes in direct normal irradiance (DNI) to the heat sink thermal output of the hybrid system. The results showed that the annual net thermal power output in California, USA can be three times more than the annual net thermal power output in Taars, Denmark. Finally, multiple hybrid configurations with varying solar field sizes were simulated based on the heat demand of two different university campuses DHS. The results showed that, retrofit applications of this hybrid DHS system coupled with TES could reduce the natural gas consumption of the existing systems between 25% and 41%. The use of hybrid RTES highlighted in this paper can be extended to many more opportunities.

district heating↗

Renewable energy analysis in indigenous communities using bottom-up demand prediction

This paper provides a methodology for the holistic analysis of hybrid renewable energy systems in rural communities. Electric demand is an important component for modeling and analysis of renewable energy systems. Typically, electric demand data is not available due to the internal privacy policies of utility providers. Therefore, this study proposes the use of bottom-up approaches for the development of the electric demand profile, considering the general homogeneity of residential and commercial buildings in rural communities. As a test case, this study develops the electric demand profile and investigates the technical and environmental feasibility of a hybrid renewable energy system for the New Town community on the Fort Berthold Indian Reservation (FBIR) in North Dakota. This study conducts the hybrid renewable energy system’s analysis by developing scripts in the LK scripting language and integrating System Advisor Model software’s open-source modules for modeling of renewable energy systems. Here, the results for the validation testbed of this study show that hybrid renewable resources have higher ratios of energy used for self-consumption to the total energy generated compared to stand-alone wind and PV farms.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design and Techno-Economic Analysis of a 150-MW Hybrid CSP-PV Plant

The interest in concentrated solar power (CSP) has increased significantly over the years since it is dispatchable and requires thermal storage instead of electric storage. When compared to photovoltaics (PV), CSP has a higher Levelized Cost of Electricity (LCOE). In this paper, we present the design of a hybrid power plant using CSP and PV technologies. The hybrid system offers a lower LCOE than CSP but will still have dispatchability. The 150-MW hybrid system consists of 100-MW CSP and 50-MW PV capacity. Furthermore, the CSP system (central receiver system) has a molten salt-based thermal storage of 12 hours. The geographical focus of this study is Pakistan, which is a developing country struggling with energy crises, but which has high solar potential. The hybrid system is modeled using the System Advisor Model (SAM). The results show that by hybridizing CSP with PV, the LCOE can be reduced by 18.5%.

concentrated solar power↗

Dynamically Downscaled Hourly Future Weather Data with 12-km Resolution Covering Most of North America

This is an hourly future weather dataset for energy modeling applications. The dataset is primarily based on the output of a regional climate model (RCM), i.e., the Weather Research and Forecasting (WRF) model version 3.3.1. The WRF simulations are driven by the output of a general circulation model (GCM), i.e., the Community Climate System Model version 4 (CCSM4). This dataset is in the EPW format, which can be read or translated by more than 25 building energy modeling programs (e.g., EnergyPlus, ESP-r, and IESVE), energy system modeling programs (e.g., System Advisor Model (SAM)), indoor air quality analysis programs (e.g., CONTAM), and hygrothermal analysis programs (e.g., WUFI). It contains 13 weather variables, which are the Dry-Bulb Temperature, Dew Point Temperature, Relative Humidity, Atmospheric Pressure, Horizontal Infrared Radiation Intensity from Sky, Global Horizontal Irradiation, Direct Normal Irradiation, Diffuse Horizontal Irradiation, Wind Speed, Wind Direction, Sky Cover, Albedo, and Liquid Precipitation Depth. The weather data is created for two emissions scenarios: RCP4.5 and RCP8.5 and spans two 10-year time slices in the future: 2045 - 2054 and 2085 - 2094. It offers a spatial resolution of 12 km by 12 km with extensive coverage across most of North America. Due to the enormous size of the entire dataset, in the first stage of its distribution, we provide 20 years of future weather data for the centroid of each Public Use Microdata Area (PUMA), excluding Hawaii. PUMAs are non-overlapping, statistical geographic areas that partition each state or equivalent entity into geographic areas containing no fewer than 100,000 people each. The 2,378 PUMAs as a whole cover the entirety of the U.S. The weather data can be utilized alongside the large-scale energy analysis tools, ResStock and ComStock, developed by National Renewable Energy Laboratory, whose smallest resolution is at the PUMA scale. The data for RCP4.5 is still being processed and will be published soon.

Array↗

Validation of Photovoltaic Modeling Tool Solargraf Against Measured Data

Solargraf is a cloud-based 3D design tool by Enphase Energy that allows users to design solar and storage systems with a variety of elements. Through a Cooperative Research and Development Agreement (CRADA), Enphase Energy collaborated with the National Renewable Energy Laboratory (NREL) to validate Solargraf's 3D design simulation against measured PV system performance. This study follows the same methodology of similar validation studies completed at NREL. The predicted performance results from simulations in both Solargraf and NREL's System Advisor Model (SAM) tool were compared with measured data to evaluate performance predictions.

14 SOLAR ENERGY↗

Spaced out: An economic framework to explore the impacts of PV panel spacing on large-scale farming in Colorado

CONTEXT Agrivoltaic systems co-locate solar technologies with agricultural operations on an integrated plot of land and potentially provide benefits to both energy and agricultural systems. To date, large-scale (>5-MW) agrivoltaic projects in the United States have been limited to grazing and ecovoltaic applications, raising questions about the impact and scalability of agrivoltaic crop systems. Many agrivoltaic designs raise the height of the solar panels to accommodate agricultural practices while keeping energy density high. However, raising the panels results in increased photovoltaic (PV) development costs, which often are higher than the economic returns of crop production underneath the panels. This leads to unfavorable project economics and the need for other agrivoltaic solutions than raising panels. OBJECTIVE To explore other solutions, we perform an initial feasibility analysis for an agrivoltaic solution that can integrate with large-scale farming practices by increasing the row spacing in between panels. Increased PV row spacing is a low-cost approach for scaling agrivoltaics to accommodate crop production and this spacing can be tailored to required crop equipment for different regions. Increasing row spacing will reduce the power density (PV installed per acre), but in areas that are not land limited, these agrivoltaic designs could be economically feasible. Our analysis establishes a framework for a feasibility analysis for where and with what crops spaced out panel agrivoltaic solutions might be economical. METHODS Using a case study for large-scale agriculture crops in Colorado, we establish a framework for wide-row agrivoltaic economic feasibility analysis. We utilized the System Advisor Model to calculate technoeconomic metrics to compare different row spacing solutions and capture tradeoffs of these system designs. RESULTS AND CONCLUSIONS We find that, in some circumstances, wider row agrivoltaic solutions that allow for continued mechanized crop production can provide economic benefits over a traditional utility-scale PV system. For most crops examined in this analysis, roughly $\$$200/acre in agricultural profit justified spacing out the panels to at least 31.7 ft. to accommodate agrivoltaic configurations versus PV only configurations. Additionally, opportunities for increased agricultural revenue with agrivoltaic systems allow PV project economics to tolerate a larger range of CAPEX variability while remaining economically viable relative to the PV only configurations. SIGNIFICANCE This framework can be adapted for a wide variety of crops and regions and allows for examination of economically favorable sites for future agrivoltaic systems that utilize different configuration and expand opportunities for agrivoltaics.

14 SOLAR ENERGY↗

NREL Tools Help Identify and Evaluate Renewable Energy Projects

NREL offers no-cost, publicly available web tools that can be used throughout the development of behind-the-meter renewable energy projects. These tools help gauge initial project potential, optimize system sizing, and refine project economics. This flyer compares four tools that can be used at various stages of project development: Economic Site Analysis (ESA) Tool, PVWatts Calculator, REopt (TM) Lite, and System Advisor Model (SAM).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improvement in PV Plant LCOE from Convection Heat Transfer Changes from Altered Plant Layout

Heat transfer modeling that accounts for how convective cooling changes with PV array layout has been found to improve system LCOE in certain climates conditions. Analysis of fixed tilt systems performed using the System Advisor Model reveals that reducing system ground coverage ratio from 0.46 to 0.35 can lead to as much as a 1.7% increase in module annual energy output in Phoenix. Depending on climate conditions, these energy increases due to changing convective cooling flow can lead to LCOE improvements for systems with increased row spacing despite the increased wiring and land costs associated with increased module row spacing. While the energy gain from decreasing system ground coverage ratio can be largely attributed to increased plane of array irradiance, the convection cooling considerations presented here can have a non-negligible impact on PV power plant energy output and economic viability depending on climate conditions and array spacing parameters.

heat transfer↗

NREL's Tools for AgriPV Modeling

As part of the Tools and Apps for Agrivoltaics session, NREL presents their tools that have capabilities for modeling PV and agricultural dual use sites. These include the System Advisor Model (SAM), bifacial_radiance open-source raytracing tool, and a simplified agriPV calculator available in the InSPIRE website.

agriculture↗