Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Interlaboratory Reproducibility of Contour Method Data in a High Strength Aluminum Alloy

The contour method for residual stress measurement has seen significant development, but an experimental reproducibility study utilizing physical samples has not been published. A double-blind reproducibly study is reported, having scope beginning with EDM cutting and ending with residual stress calculation. A reinforced I-beam sample geometry is identified for its unique residual stress profile when extracted from residual stress bearing quenched aluminum bar (7050-T74). Contour measurements are prescribed on a midplane of symmetry with dimensions 24.0 mm by 50.0 mm. Fourteen identically prepared samples are fabricated from a single long bar with well characterized and uniform residual stress. Five samples throughout the bar are identified for planning measurements to validate sample uniformity and overall suitability of the residual stress field. The planning measurements employ a range of techniques: contour method, neutron diffraction, and hole-drilling. Eight samples are distributed to an international group of participants to execute their standard measurement practice. A double-blind process is followed to provide anonymity. Results are provided by eight participants: six being self-similar and two being quite different, the latter set aside as outliers. An average residual stress field is established from non-outlying results and the spatial distribution of reproducibility standard deviation is determined. The average stress field ranges from -60 to 70 MPa and the reproducibility standard deviation averages 8.1 MPa on the measurement plane. The average reproducibility standard deviation is about 3 × larger for points within 1.0 mm of plane boundaries (17.6 MPa) than for the remaining points (6.1 MPa). Reproducibility standard deviation (among different labs) for contour method residual stress measurement is found to be very similar to repeatability standard deviation (in a single lab) reported in prior work. The reproducibility observed here, for the entire measurement process, is also similar to that found in a prior reproducibility study limited to contour method data analysis.

36 MATERIALS SCIENCE↗

Fuel cladding post-quench LOCA embrittlement: mechanical test relevance

During a loss-of-coolant-accident (LOCA), the fuel cladding is submitted to a high temperature increase in a steam environment, along with an internal pressure increase which would eventually lead to ballooning and burst of the cladding. Steam could then penetrate through the burst opening and lead to inner surface oxidation and secondary-hydriding of the cladding. Post-quench cladding rupture can then occur either in two-sided oxidized area with wall thinning due to ballooning, or in single-sided oxidized area with large hydrogen content. Common tests involved in the evaluation of the post-quench ductility are Ring Compression Tests (RCT), Expansion Due to Compression Test (EDC) or Axial Tensile Tests (AT). Questions arise about these mechanical tests, as for instance, the influence on sample failure of the oxide layer thickness partitioning between inner and outer diameter. A systematic study was carried out to compare several mechanical tests on both single-sided and two-sided Zircaloy-4 oxidized samples. Five different mechanical tests were compared, including RCT: C-shaped ring Compression Test (CCT), Axial Tensile test (AT), Ring Tensile Test with well-defined machined gage section (RTT) and plain Ring Tensile Test (pRTT). All samples were taken from cladding tubes which had been oxidized in steam at 1200 Celsius degrees and then water-quenched. Mechanical tests were performed at room temperature and two to three samples were tested for each oxidation conditions and for every sample geometry to assess the reproducibility. Metallographic examinations were carried out to measure the ZrO{sub 2} and αZr(O) layer thicknesses and the ex-β/α(O) phase fraction. Mean hydrogen content measurements were also performed systematically on each sample. Results indicate that the different mechanical tests have not the same sensitivity to the oxide layer partitioning: RTT and pRTT load at failure seems to depend mainly on the cumulated oxide layer thickness rather than on its partitioning, whereas this parameter has an impact on CCT and AT test results. For all tensile tests, stresses at failure were derived from load-displacement curves. The failure of brittle samples was assumed to be governed by linear elastic fracture mechanics. Using conventional stress intensity factor solution, a value of the material fracture toughness controlling the sample failure was determined from experimental results and discussed. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in sample density between samples and standards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kiloampere, Variable-Temperature, Critical-Current Measurements of High-Field Superconductors

We review variable-temperature, transport critical-current ($I_\text{c}$) measurements made on commercial superconductors over a range of critical currents from less than 0.1 A to about 1 kA. We have developed and used a number of systems to make these measurements over the last 15 years. Two exemplary variable-temperature systems with coil sample geometries will be described: a probe that is only variable-temperature and a probe that is variable-temperature and variable-strain. The most significant challenge for these measurements is temperature stability, since large amounts of heat can be generated by the flow of high current through the resistive sample fixture. Therefore, a significant portion of this review is focused on the reduction of temperature errors to less than ±0.05 K in such measurements. A key feature of our system is a pre-regulator that converts a flow of liquid helium to gas and heats the gas to a temperature close to the target sample temperature. The pre-regulator is not in close proximity to the sample and it is controlled independently of the sample temperature. This allows us to independently control the total cooling power, and thereby fine tune the sample cooling power at any sample temperature. The same general temperature-control philosophy is used in all of our variable temperature systems, but the addition of another variable, such as strain, forces compromises in design and results in some differences in operation and protocol. These aspects are analyzed to assess the extent to which the protocols for our systems might be generalized to other systems at other laboratories. Our approach to variable-temperature measurements is also placed in the general context of measurement-system design, and the perceived advantages and disadvantages of design choices are presented. To verify the accuracy of the variable-temperature measurements, we compared critical-current values obtained on a specimen immersed in liquid helium (“liquid” or $I_{\text{c}}$ $_{\text{liq}}$) at 5 K to those measured on the same specimen in flowing helium gas (“gas” or Ic gas) at the same temperature. These comparisons indicate the temperature control is effective over the superconducting wire length between the voltage taps, and this condition is valid for all types of sample investigated, including Nb-Ti, Nb 3 Sn, and MgB 2 wires. The liquid/gas comparisons are used to study the variable-temperature measurement protocol that was necessary to obtain the “correct” critical current, which was assumed to be the $I_{\text{c}}$ $_{\text{liq}}$. We also calibrated the magnetoresistance effect of resistive thermometers for temperatures from 4 K to 35 K and magnetic fields from 0 T to 16 T. This calibration reduces systematic errors in the variable-temperature data, but it does not affect the liquid/gas comparison since the same thermometers are used in both cases.

47 OTHER INSTRUMENTATION↗

Low temperature magnetic behaviour of glass-covered magnetic microwires with gradient nanocrystalline microstructure

Slow nanocrystallization driving dynamics can be affected by the combination of two factors: sample residual stresses and sample geometry. This effect is evidenced at the initial stages of nanocrystallization of amorphous CoFeSiBCuNb magnetic microwires. Transmission electron microscopy observations indicate how crystallization at temperatures between 730 and 780 K results in a graded microstructure where the crystallization at the surface skin of the microwire, which remains almost amorphous, differs from that of the middle, where elongated grains are observed, and inner regions. However, samples annealed at higher temperatures present a homogeneous microstructure. The effect of gradient microstructure on magnetic properties has been also analyzed and a loss of bistable magnetic behaviour at low temperatures, from that obtained in the amorphous and fully nanocrystallized sample, has been observed and ascribed to changes in sign of magnetostriction for measuring temperatures below 100 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Grain Boundary and Lattice Fracture Toughness of UO 2 Measured Using Small-Scale Mechanics

Small-scale mechanical testing has been used to isolate the properties of individual grain boundaries and regions of the lattice in undoped UO 2 polycrystals. Notched microcantilever specimens were prepared by focused ion beam milling and tested in bending. Fracture toughness values were calculated from finite element analysis of the sample geometry at fracture load using the J-integral method. Lattice and grain boundary fracture toughness values of 1.17 ± 0.16 MPa m 1/2 and 1.08 ± 0.08 MPa m 1/2 , respectively, were obtained. The similarity between the lattice and grain boundary fracture toughness values is consistent with the preference for transgranular room-temperature fracture in UO 2 . The grain boundary and lattice fracture toughness values also agree well with the toughness of dense polycrystals, which suggests that microstructural-scale toughening mechanisms are limited in such samples.

36 MATERIALS SCIENCE↗

Multispectral Gamma-Ray Analysis Using Clover Detectors with Application to Uranium Fission Product Analysis

A high-efficiency gamma-ray counting system has been built at Los Alamos National Laboratory for use in analyzing nuclear forensics samples. This system consists of two clover high-purity germanium detectors and is surrounded by a thallium-doped sodium iodide annulus. Special precautions have been taken to ensure the system has a low background. The system is connected to XIA Pixie-4 fast digitizers and collects data in list-mode. This work is split into two main parts. The first part describes the proper steps and techniques to initialize the settings of a detector system connected to fast digitizers in order to optimize the system for resolution and throughput. The various counting modes for this particular system are described in detail, including the benefits and drawbacks of each mode. Steps are then shown to characterize the system by obtaining efficiency curves for various counting modes and sample geometries. Because of the close counting geometry involved with this system, true coincidence summing factors must be calculated, and are done so in part by measuring the peak-to-total ratios of the system in its various counting modes across a wide energy range. The dead-time for the system can be complicated due to the multiple inputs of the system. Techniques for calculating the dead-time of multiple-detector systems are discussed. The second part of this work shows the system’s usefulness in analyzing nuclear forensics samples, specifically irradiated enriched uranium. Three fission product parent-daughter pairs of different lifetimes are analyzed over a course of six months. The activities of each nuclide are calculated at each time step. Age dating techniques using the parent-daughter pairs are discussed, as well as the detection limits of each nuclide for a range of sample ages. Finally, avenues for further research are presented, as well as potential sources of error or uncertainty for this work.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Detection and imaging of chemicals and hidden explosives using terahertz time-domain spectroscopy and deep learning

Detecting concealed chemicals and explosives remains a critical challenge in global security. Terahertz time-domain spectroscopy (THz-TDS) offers a promising non-invasive and stand-off detection technique owing to its ability to penetrate optically opaque materials without causing ionization damage. While many chemicals exhibit distinct spectral features in the terahertz range, conventional terahertz-based detection methods often struggle in real-world environments, where variations in sample geometry, thickness, and packaging can lead to inconsistent spectral responses. In this study, we present a chemical imaging system that integrates THz-TDS with deep learning to enable accurate pixel-level identification and classification of different explosives. Operating in reflection mode and enhanced with plasmonic nanoantenna arrays, our THz-TDS system achieves a peak dynamic range of 96 dB and a detection bandwidth of 4.5 THz, supporting practical, stand-off operation. By analyzing individual time-domain pulses with deep neural networks, the system exhibits strong resilience to environmental variations and sample inconsistencies. Blind testing across eight chemicals—including pharmaceutical excipients and explosive compounds—resulted in an average classification accuracy of 99.42% at the pixel level. Notably, the system maintained an average accuracy of 88.83% when detecting explosives concealed under opaque paper coverings, demonstrating its robust generalization capability. These results highlight the potential of combining advanced terahertz spectroscopy with neural networks for highly sensitive and specific chemical and explosive detection in diverse and operationally relevant scenarios.

Imaging and sensing↗

Single-Use Destructive Assay for Uranium Hexafluoride Sampling

Sampling uranium hexafluoride (UF6) for the determination of enrichments by destructive analysis (DA) is a critical component in the International Atomic Energy Agency’s layered safeguards approach for uranium processing facilities. Typically, gram-quantity UF6 samples are collected during inspections and stored under tag-and-seal until transportation to an off-site analytical laboratory. The shipping times can be long, and evolving restrictions on radioactive/corrosive materials shipments may increasingly limit the IAEA’s ability to transport UF6 samples easily. Pacific Northwest National Laboratory has developed a low-cost UF6 sampling technology called Single-Use Destructive Assay (SUDA) that addresses these challenges, as well as provides DA sample geometries that can be tailored for different analytical methods, including potential on-site analyses. The SUDA samplers, along with a unique holder, are designed for direct attachment to existing taps at uranium processing facilities, allowing gaseous UF6 to come into direct contact with a zeolite film. The SUDA technology features the ability to capture uranium in a more easily shipped and handled form as the solid, more stable, and relatively less hazardous hydrated uranyl fluoride (UO2F2•nH2O), which is formed through the controlled hydrolysis of UF6. We have recently simulated uranium collection under enrichment plant sampling conditions to further improve our understanding of SUDA sampling. Presented here is our recent work on measuring the relationship between sampling conditions and uranium collection, which includes control of the uranium-mass-to-zeolite ratio and assessing variable UF6 gas and sampling parameters that can affect collection using the SUDA sampler.

Pope, Timothy R.↗

Statistical variability and confidence intervals for planar dose QA pass rates

Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics of various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intrinsic and extrinsic effects on the fracture toughness of ductile metallic glasses

The potential application of metallic glasses (MGs) as structural materials demands accurate measurements of their toughness and the understanding of the underlying factors affecting it. Currently, it is challenging to precisely measure the toughness of MGs, especially ductile MGs. Measured toughness values are widely scattered, even for MGs with identical compositions. That is attributed to the combined effect of intrinsic and extrinsic factors including processing, sample geometries, and loading conditions. A fundamental understanding of the influences of these elements is thus of great significance. In the present study, molecular dynamics simulations are performed to investigate the influence of intrinsic and extrinsic effects on the fracture toughness of CuZr MGs. In particular, focused is placed on the effects of cooling rate, notch shape and size, strain rate, and temperature. The results indicate that the fracture toughness of a MG scales with the cooling rate used to prepare it. This is attributed to increased free volume content generated at high cooling rates, which enhances plastic deformation and amplifies the associated energy dissipation during plastic deformation events. Fracture toughness also increases with the strain rate, arguably due to strain rate-induced crack extension delay. Overall, the results demonstrate that the largest fracture toughness are achieved when MG samples are fabricated at high cooling rates and subjected to high strain rate deformation. In addition, results suggest that the fracture toughness decreases with increasing temperature, due to the significant decrease in strength. Here, the correlations revealed between these crucial intrinsic and extrinsic parameters and the calculated MG fracture toughness support the development of a framework to understand the root of the discrepancies in the measurement of the toughness of MGs and provide insights into the design of tough MGs for structural applications.

36 MATERIALS SCIENCE↗

Characterization of tissue magnetic susceptibility-induced distortions for MRIgRT

Purpose: MR image geometric integrity is one of the building blocks of MRI-guided radiotherapy. In particular, tissue magnetic susceptibility-induced effects are patient-dependent and their behavior is difficult to assess and predict. In this study, the authors investigated in detail the characteristics of susceptibility ({chi}) distortions in the context of MRIgRT, including the case of two common MR-linac system configurations. Methods: The magnetic field distortions were numerically simulated for several imaging parameters and anatomical sites, i.e., brain, lung, pelvis (with air pockets), and prostate. The simulation process consisted of (a) segmentation of patient CT data into susceptibility relevant anatomical volumes (i.e., soft-tissue, bone and air/lung), (b) conversion of CT data into susceptibility masks by assigning bulk {chi} values to the structures defined at (a), (c) numerical computations of the local magnetic fields by using a finite difference algorithm, and (d) generation of the geometric distortion maps from the magnetic field distributions. For each patient anatomy, the distortions were quantified at the interfaces of anatomical structures with significantly different {chi} values. The analysis was performed for two specific orientations of the external main magnetic field (B{sub 0}) characteristic to the MR-linac systems, specifically along the z-axis for a bore MR scanner and in the (x,y)-plane for a biplanner magnet. The magnetic field local perturbations were reported in ppm. The metrics used to quantify the geometric distortions were the maximum, mean, and range of distortions. The numerical simulation algorithm was validated using phantom data measurements. Results: Susceptibility-induced distortions were determined for both quadratic and patient specific geometries. The numerical simulations showed a good agreement with the experimental data. The measurements were acquired at 1.5 and 3 T and with an encoding gradient varying between 3 and 20 mT/m by using an annular phantom mimicking the water-air and water-oil {chi} interfaces. For quadratic geometries, the magnitude of field distortion increased rapidly with the size of the inhomogeneity up to about 10 mm and then tended to plateau. This trend became more evident for materials with a larger {Delta}{chi} relative to water. The simulations showed only a slight increase in the maximum distortion values when the B{sub 0} orientation was varied with regard to the shape of the {chi} inhomogeneity. In the case of patient anatomy, the largest distortion values arose at the air-soft-tissue interface. Considering the two MR-linac system configurations and comparing the field distortion values corresponding to all organ structures, the distortions tended to be larger for the biplanar magnet. The authors provide a reference table with ppm values which can be used to easily evaluate the geometric distortions for patient data as a function of B{sub 0} and the strength of the encoding gradient. Conclusions: The susceptibility distortions were quantified as a function of multiple parameters such as the {chi} inhomogeneity size and shape, the magnitude of B{sub 0} and the readout gradient, and the orientation of B{sub 0} with respect to the sample geometry. The analysis was performed for several anatomical sites and corresponding to two B{sub 0} orientations as featured by MR-linac systems.

60 APPLIED LIFE SCIENCES↗

Millimeter-Thick Liquid Crystalline Elastomer Actuators Prepared by-Surface-Enforced Alignment

Here, liquid crystalline elastomers (LCE) are thermally cyclable, compliant actuators with compelling mechanical properties. The large and programmable deformation of LCE has led to numerous functional examinations spanning optics, medical devices, and robotics. A well-established method to prepare complex LCE actuators is to utilize surface-enforced photoalignment. Herein, a facile and scalable approach is reported to circumvent the physical limits of surface-enforced alignment (e.g., samples that are 50 µm or less) to amplify the achievable force output in LCE. Applying an approach termed direct layering, the thermomechanical response of LCE elements prepared with +1 disclination patterns in a range of compositions and thicknesses is contrasted. The design and preparation of +1 disclination patterns and arrays is explored to assess the contribution of sample geometry and overlap to deformation and force output. The methodology detailed in this contribution allows for the preparation of elements ≈1 mm in thickness that are capable of actuating large objects. Furthermore, the fabrication of these elements uniquely enables the realization of mechanical instabilities to hasten the actuation rate in response to thermal change and to enable leaping.

36 MATERIALS SCIENCE↗

Comparison of sparse domain approaches for 4D SPECT dynamic image reconstruction

Purpose: Dynamic imaging (DI) provides additional diagnostic information in emission tomography in comparison to conventional static imaging at the cost of being computationally more challenging. Dynamic single photon emission computed tomography (SPECT) reconstruction is particularly difficult because of the limitations in the sampling geometry present in most existing scanners. We have developed an algorithm Spline Initialized Factor Analysis of Dynamic Structures (SIFADS) that is a matrix factorization method for reconstructing the dynamics of tracers in tissues and blood directly from the projections in dynamic cardiac SPECT, without first resorting to any 3D reconstruction. Methods: SIFADS is different from "pure" factor analysis in dynamic structures (FADS) in that it employs a dedicated spline-based pre-initialization. In this paper, we analyze the convergence properties of SIFADS and FADS using multiple metrics. The performances of the two approaches are evaluated for numerically simulated data and for real dynamic SPECT data from canine and human subjects. Results: For SIFADS, metrics analyzed for reconstruction algorithm convergence show better features of the metric curves vs iterations. In addition, SIAFDS provides better tissue segmentations than that from pure FADS. Measured computational times are also typically better for SIFADS implementations than those with pure FADS. Conclusion: The analysis supports the utility of the pre-initialization of a factorization algorithm for better dynamic SPECT image reconstruction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image fusion for neutron tomography of nuclear fuel

Image fusion, the process of combining different images together, can be useful to create a more complete picture. In this work, image fusion is applied to neutron tomography of nuclear fuel with the goal of enhancing the information obtained about the fuel. Different reconstruction methods, such as Feldkamp, Davis and Kress filtered back projection and Simultaneous Reconstruction Technique, were combined to enhance image quality. This methodology was shown to reduce noise and ring artifacts without sacrificing sharp edges, allowing for a more accurate representation of sample geometry. Technique enhancements and future applications for the neutron imaging community are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of Orientation of Weld Line on Formability of Electron Beam-Welded Dissimilar Thickness Titanium Sheets

Recently, manufacturing industries are looking forward to get insight into the influence of weld orientation on formability of tailor-welded blanks (TWBs) of titanium sheets for design and fabrication of lightweight components. Hence, commercially pure titanium (CP Ti) sheets of 1.0 and 1.2 mm thickness were joined together by electron beam welding process using accelerating voltage of 55 kV, beam current of 14.9 mA and welding speed of 865 mm/min. Two different types of TWBs with weld line perpendicular to the rolling direction (WL ⊥ RD) and weld line parallel to the rolling direction (WL || RD) were fabricated, and subsequently, the tensile test, microstructure and microhardness characterizations were conducted to ensure quality of weld. The limiting dome height (LDH) tests were carried out using laboratory-scale setup to evaluate forming behavior of both the above TWBs in terms of FLD, strain distribution, weld line movement and failure location. It was found that the tensile stress–strain response and formability performance of TWBs were significantly influenced by weld line orientation with lower ductility, ultimate tensile strength and LDH in TWB of WL || RD. Moreover, significant weld line movement and non-uniform strain distribution with necking and subsequently fracture were observed away from the weld line in thinner 1.0 mm CP Ti sheets depending on both sample geometry and weld line orientation.

36 MATERIALS SCIENCE↗

Influence of Local Inhomogeneity of Thermomechanical Treatment Conditions on Microstructure Evolution in Aluminum Alloys

The influence of local inhomogeneity of the stress–strain condition on structure and texture evolution during thermomechanical treatment of aluminum alloys is studied in this work. For this purpose, laboratory rolling and plane strain tests that simulated roughing mill thermomechanical modes were performed. For all processes, the local inhomogeneity of structure evolution was estimated. For this purpose, x-ray texture analysis, EBSD and optical microscopy were used. Additionally, the calculations which allow to evaluate local inhomogeneity of stress–strain conditions for the each process were performed. The experimental results were compared with mathematical simulation output. They indicated structure and texture evolution inhomogeneities, especially during the plane strain and industrial rolling processes. In the plane strain test, typical local deformation zones occurred with different resulting grain size and texture effects than those observed in both rolling processes. This difference was mainly associated with different stress states, strain intensity and strain rate distribution throughout the deformation zone. This study demonstrated that the inhomogeneity of these parameters has a strong impact on structure and texture evolution in the first stage of thermomechanical treatment. In the center layer, laboratory rolling could adequately generate the structure and texture effects observed during rolling of ingots in a commercial mill. Plane strain tests can generate useful results only in the case of adequate choice of sample geometry.

36 MATERIALS SCIENCE↗