Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling calorimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Burning characteristics and fiber retention of graphite/resin matrix composites

Graphite fiber reinforced resin matrix composites were subjected to controlled burning conditions to determine their burning characteristics and fiber retention properties. Two types of burning equipment were used. Small samples were burned with a natural gas fired torch to study the effects of fiber orientation and structural flaws such as holes and slits that were machined into the laminates. Larger laminate samples were burned in a Heat Release Rate Calorimeter. Unidirectional epoxy/graphite and polyimide/graphite composites and boron powder filled samples of each of the two composite systems were burn tested and exposed to a thermal radiation. The effects of fiber orientation, flaws, and boron filler additives to the resins were evaluated. A high char forming polyimide resin was no more effective in retaining graphite fibers than a low char forming epoxy resin when burning in air.

Bowles, K. J.↗

Upgrading the Fast Calorimeter Simulation in ATLAS

The tremendous need for simulated samples now and even more so in the future, encourages the development of fast simulation techniques. The Fast Calorimeter Simulation is a faster though less accurate alternative to the full calorimeter simulation with GEANT4. It is based on parametrizing the longitudunal and lateral energy deposits of single particles in the ATLAS calorimeter. Principal component analysis and machine learning techniques are used to improve the performance and decrease the memory need compared to the current version of the ATLAS Fast Calorimeter Simulation. The parametrizations are expanded to cover very high energies and very forward detector regions, to increase the applicability of the tool. A prototype of this upgraded Fast Calorimeter Simulation has been developed and first validations with single particles show substantial improvements over the previous version.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Safer Aviation Materials Tested

A series of thermally stable polymer samples were tested. These materials are called low heat release materials and are designed for aircraft interior decorative materials. The materials are designed to give off a minimum amount of noxious gases when heated, which increases the possibility that people can escape from a burning aircraft. New cabin materials have suitably low heat release so that fire does not spread, toxic chemicals are not given off, and the fire-emergency escape time for crew and passengers is lengthened. These low heat-release materials have a variety of advantages and applications: interiors for ground-based facilities, interiors of space vehicles, and many commercial fire-protection environments. A microscale combustion calorimeter at the Federal Aviation Administration's (FAA) Technical Center tested NASA Langley Research Center materials samples. The calorimeter is shown. A sharp, quantitative, and reproducible heat-release-rate peak is obtained in the microscale heat-release-rate test. The newly tested NASA materials significantly reduced the heat release capacity and total heat release. The thermal stability and flammability behavior of the samples was very good. The new materials demonstrated a factor of 4 reduction in total heat release over ULTEM (a currently used material). This information is provided in the following barchart. In other tests, the materials showed greater than a factor 9 reduction in heat-release capacity over ULTEM. The newly tested materials were developed for low dielectric constant, low color, and good solubility. A scale up of the material samples is needed to determine the repeatability of the performance in larger samples. Larger panels composed of the best candidate materials will be tested in a larger scale FAA Technical Center fire facility. The NASA Glenn Research Center, Langley (Jeff Hinkley), and the FAA Technical Center (Richard Lyon) cooperatively tested these materials for the Accident Mitigation aspects of Fire Prevention under NASA's Aviation Safety Program.

Palaszewski, Bryan A.↗

Hodoscope Measurements of the Spectrum of Cosmic Electrons Between 10 Gev and 100 Gev

In an attempt to reduce divergences among independent measurements of the electron spectrum above 10 GeV, electrons were detected with the aid of a large hodoscope which incorporates 8 trays of Geiger tubes and 10 scintillation counters into a calorimeter containing 33 radiation lengths of lead. This instrument was thoroughly calibrated up to 9 GeV with an electron synchrotron and was flown twice at a depth of 5 g/sq cm for a total of 30 hours at ceiling. Electron showers at 10 GeV are completely contained within the calorimeter where their ionization is sampled twelve times, and where hodoscope trays provide information on the geometrical distribution of shower particles. Electrons appeared in a histogram of number of events vs. a X2 measure of goodness of fit to electron shower curves as a clearly resolved peak standing well above the nuclear background. The initial ionization and the lateral spread of shower particles are consistent with those of calibration electrons. In contrast, the behavior of the nuclear continuum associated with minimum ionizing incident particles is different from that of calibration electrons but similar to that of nuclear events associated with incident helium nuclei. The differential electron spectrum from 10 to 100 GeV was obtained.

Meegan, C. A.↗

Design, development and test of shuttle/Centaur G-prime cryogenic tankage thermal protection systems

The thermal protection systems for the shuttle/Centaur would have had to provide fail-safe thermal protection during prelaunch, launch ascent, and on-orbit operations as well as during potential abort. The thermal protection systems selected used a helium-purged polyimide foam beneath three rediation shields for the liquid-hydrogen tank and radiation shields only for the liquid-oxygen tank (three shields on the tank sidewall and four on the aft bulkhead). A double-walled vacuum bulkhead separated the two tanks. The liquid-hydrogen tank had one 0.75-in-thick layer of foam on the forward bulkhead and two layers on the larger area sidewall. Full scale tests of the flight vehicle in a simulated shuttle cargo bay that was purged with gaseous nitrogen gave total prelaunch heating rates of 88,500 Btu/hr and 44,000 Btu/hr for the liquid-hydrogen and -oxygen tanks, respectively. Calorimeter tests on a representative sample of the liquid-hydrogen tank sidewall thermal protection system indicated that the measured unit heating rate would rapidly decrease from the prelaunch rate of approx 100 Btu/hr/sq ft to a desired rate of less than 1.3 Btu/hr/sq ft once on orbit.

Knoll, Richard H.↗

Design, development, and test of Shuttle/Centaur G-prime cryogenic tankage thermal protection systems

The thermal protection systems (TPS) for the Shuttle/Centaur were designed to provide fail-safe thermal protection during prelaunch, launch ascent, and on-orbit operations as well as during potential abort, where the Shuttle and Centaur would return to earth. The TPS selected used a helium-purged polyimide foam beneath three radiation shields for the liquid-hydrogen (LH2) tank and radiation shields only for the liquid-oxygen (LO2) tank. A double-walled vacuum bulkhead separated the two tanks. The LH2 tank had one 1.9 cm-thick layer of foam on the forward bulkhead and two layers on the larger-area sidewall. Full scale tests of the flight vehicle in a simulated Shuttle cargo bay gave total prelaunch heating rates of 29.5 and 12.9 kW for the LH2 and LO2 tanks, respectively. Calorimeter tests on a representative sample of the LH2 tank sidewall TPS indicated that the measured unit heating one would rapidly decrease from the prelaunch rate of about 300 W/sq m to a desired rate less than 4 W/sq m once on-orbit.

Macneil, Peter N.↗

Progress Toward Fast Decay Energy Spectroscopy for Actinide Analysis

Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reduction Enhancement Mechanisms of a Low-Grade Iron Ore–Coal Composite by NaCl

The reduction behavior of a low iron grade with high SiO{sub 2} content ore–coal composite was investigated in the temperature range of 1143 K to 1263 K (870 °C to 990 °C). Sodium chloride was chosen as an additive to promote this reduction process. The effect of the sodium chloride addition and its mechanism was also investigated. Results showed that the added sodium chloride could enhance the reduction of wustite to iron due to the decrease of fayalite, and a higher metallization ratio of reduced sample was obtained. Thermogravimetric–differential scanning calorimeter analysis showed that sodium chloride could greatly facilitate the gasification process of coal and, thus, provide sufficient carbon monoxide to the reduction process of iron oxides. Meanwhile, sodium chloride promoted the reduction process of iron ore pellets directly as the coal gasification effect was excluded. Microstructures of reduced sample revealed that sodium chloride broke the structure of ore and enhanced the growth of newly formed iron particles. As the ore–coal composite with mol (C/Fe = 1.4) and 3 mass pct sodium chloride addition was roasted at 1233 K (960 °C) for 55 minutes, a reduced sample with metallization ration of 74.45 pct could be obtained.

36 MATERIALS SCIENCE↗

Summer Student Internship: Experimental and modeling experiences

My internship at the Los Alamos National Laboratory has been an information-filled summer. Loren Espada-Castillo brought me into her project and helped mentor and guide me through the summer. The project that I was brought into was the process of shooting materials with electrons. The electron beam we used conducts a series of shots in which electrons are generated and then fired towards a target, the sample holder. The sample holder holds either a single sample or three samples. The sample holder also consists of multiple calorimeters surrounding the sample/s. The goal is to shoot certain materials and then analyze how they react to the exposure of the electrons. We shot titanium, which was meant to serve as a containment vessel window.

36 MATERIALS SCIENCE↗

Calorimetric studies of the ammonia-water system with application to the outer solar system

A series of heating experiments was performed on the condensed ammonia-water system using a differential scanning calorimeter (DSC). The water-rich samples were cooled quickly to below 130 K, then heated at a variety of rates. Rather than a single peritectic melt at 176 K, expected for the equilibrium system of water ice and ammonia dihydrate, four enthalpic transitions were repeatedly seen in the temperature range 150-176 K. These transitions are generally consistent with the earlier calorimetric results of Van Kasteren (1973), who interpreted the lowest temperature exotherm as crystallization of an amorphous ammonia-water compound formed during cooling. We propose that both sets of experiments are seeing the crystallization of ammonia monohydrate, which is metastable relative to the dihydrate, followed by partial remelting and crystallization of dihydrate upon further heating. The apparent stability of the monohydrate in the dihydrate equilibrium field implies a potentially complex behavior of ammonia-water ices in satellites. Possible self-heating of the mixture by several tens of degrees up to the 170 K eutectic could make mobilization of ammonia-water liquids in icy satellite interiors energetically easier than previously thought.

Yarger, Jeffery↗

Study of muons near shower cores at sea level using the E594 neutrino detector

The E594 neutrino detector has been used to study the lateral distribution of muons of energy 3 GeV near shower cores. The detector consists of a 340 ton fine grain calorimeter with 400,000 cells of flash chamber and dimensions of 3.7 m x 20 m x 3.7 m (height). The average density in the calorimeter is 1.4 gm/sq cm, and the average Z is 21. The detector was triggered by four 0.6 sq m scintillators placed immediately on the top of the calorimeter. The trigger required at least two of these four counters. The accompanying extensive air showers (EAS) was sampled by 14 scintillation counters located up to 15 m from the calorimeter. Several off line cuts have been applied to the data. Demanding five particles in at least two of the trigger detectors, a total of 20 particles in all of them together, and an arrival angle for the shower 450 deg reduced the data sample to 11053 events. Of these in 4869 cases, a computer algorithm found at least three muons in the calorimeter.

Goodman, J. A.↗

Design of a sample acquistion system for the Mars exobiological penetrator

The Mars Exobiological Penetrator will be imbedded into several locations on the Martian surface. It contains various scientific instruments, such as an Alpha-Particle Instrument (API), Differential Scanning Calorimeter (DSC), Evolved Gas Analyzer (EGA) and accelerometers. A sample is required for analysis in the API and DSC. To avoid impact contaminated material, this sample must be taken from soil greater than 2 cm away from the penetrator shell. This study examines the design of a dedicated sampling system including deployment, suspension, fore/after body coupling, sample gathering and placement. To prevent subsurface material from entering the penetrator sampling compartment during impact, a plug is placed in the exit hole of the wall. A U-lever device is used to hold this plug in the penetrator wall. The U-lever rotates upon initial motion of the core-grinder mechanism (CGM), releasing the plug. Research points to a combination of coring and grinding as a plausible solution to the problem of dry drilling. The CGM, driven by two compressed springs, will be deployed along a tracking system. A slowly varying load i.e., springs, is favored over a fixed displacement motion because of its adaptability to different material hardness. However, to accommodate sampling in a low density soil, two dash pots set a maximum transverse velocity. In addition, minimal power use is achieved by unidirectional motion of the CGM. The sample will be transported to the scientific instruments by means of a sample placement tray that is driven by a compressed spring to avoid unnecessary power usage. This paper also explores possible modifications for size, weight, and time as well as possible future studies.

Thomson, Ron↗

Dual frequency comb spectroscopy of solid fuel pyrolysis and combustion: Quantifying the influence of moisture content in Douglas fir

As the fire research community develops multi-scale models to predict the spread of wildland fires, there is a need for well-controlled, small-scale experiments which provide benchmark data and fundamental understanding of the effects of key parameters on the combustion of wildland fuels. Here, we implement a unique suite of non-intrusive, quantitative diagnostics that simultaneously measure mass loss, surface temperature, in situ gas temperature and water vapor concentration, including the first implementation of dual frequency comb spectroscopy for the study of solid fuels. As a demonstration, we examine the effect of fuel moisture content on the burning of Douglas fir wood samples that are ignited under constant radiative heat flux from a cone calorimeter to provide benchmark data for multi-scale models. Peak flame temperatures 3 mm above the sample surface measured with the dual frequency comb laser spectrometer are in excess of 1200 K. The flame temperature decreases by over 150 K as fuel moisture content increases from 0.7% to 40%. This work demonstrates a platform for simultaneous, quantitative measurements of well-controlled small-scale experiments which provide benchmark data for the development of advanced modeling and simulations capable of capturing the complex physics present in wildland fire systems.

54 ENVIRONMENTAL SCIENCES↗

AC losses of Roebel and CORC ® cables at higher AC magnetic fields and ramp rates

We have measured ReBCO coated conductor-based conductor on round core (CORC ® ) and Roebel cables at 77 K in a spinning magnet calorimeter, which subjected the tapes in the samples to a radial magnetic field of 566 mT (peak) at frequencies up to 120 Hz (272 T s -1 , cyclic average) with an approximately sinusoidal waveform. The samples were oriented such that the field applied to the tapes within the cables was entirely radial, simplifying subsequent analysis. An expression for loss which included hysteretic, flux creep and eddy current losses was fit to both the CORC ® and the Roebel cables. This expression allowed easy comparison of the relative influence of eddy currents and flux creep (or power-law behavior) effects. The loss of both the CORC ® and Roebel cables measured here were seen to be essentially the sum of the hysteretic loss, flux creep effects, and the normal metal eddy current losses of the individual tapes. The losses of these cables were measured at high B × d B /d t with no coupling current loss observed under the present preparation conditions. The influence of flux creep effects on loss were not negligible. The losses of the CORC ® cable per meter of tape were seen to be reduced from the case of a flat tape because of the helical geometry of the tapes.

Physics↗

A High-Throughput MEMS-Based Differential Scanning Calorimeter for Direct Thermal Characterization of Antibodies

Calorimeters, which can be used for rapid thermal characterization of biomolecules, are getting intense attention in drug development. This paper presents a novel MEMS-based differential scanning calorimeter (DSC) for direct thermal characterization of protein samples. The DSC consisted of a pair of temperature sensors made by vanadium oxide (VOx) film with a temperature coefficient of resistivity of –0.025/K at 300 K, a microfluidic device with high thermal insulation (2.8 K/mW), and a Peltier heater for linear temperature scanning. The DSC exhibited high sensitivity (6.1 µV/µW), low noise (0.4 µW), high scanning rate (45 K/min), and low sample consumption volume (0.63 µL). The MEMS DSC was verified by measuring the temperature-induced denaturation of lysozyme at different pH, and then used to study the thermal stability of a monoclonal antibody (mAb), an antigen-binding fragment (Fab), and a dual variable domain immunoglobulin (DVD-Ig) at pH = 6. The results showed that lysozyme is a stable protein in the pH range of 4.0–8.0. The protein stability study revealed that the transition temperatures of the intact Fab fragment, mAb, and DVD proteins were comparable with conformational stability results obtained using conventional commercial DSC. These studies demonstrated that the MEMS DSC is an effective tool for directly understanding the thermal stability of antibodies in a high-throughput and low-cost manner compared to conventional calorimeters.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration of a calorimeter for measuring the performance of thermal control surfaces

The calibration to evaluate the heat leak in terms of the deviation from a perfect calorimeter is described. A thermal vacuum test was carried out to characterize the performance of the calorimeter. The calorimeter was equipped with a heater to control the sample disc temperature and with specific instrumentation to measure the heat leak. The radiation sink temperature of the black cavity target was varied from -192 to +31C, while the heater power was varied from 0 to 311 milliwatts. A steady state thermal model was developed to correlate the results. The calorimeter performance was characterized in terms of the heat leak as a percentage of the ideal heat flow of the calorimeter disc. Large deviations from ideal performance occur at low sink temperatures. The effect of the use of the heater is discussed. The effects of transient conditions during low Earth orbit are discussed. It is concluded that heat leak calibrations are necessary for a wide range of conditions.

Houseman, John↗

Energy Calibration of the Scintillating Optical Fiber Calorimeter Chamber (SOFCAL)

The Scintillating Optical Fiber Calorimeter (SOFCAL) detector is designed to make direct measures of the primary cosmic ray spectrum from -200 GeV/amu - 20 TeV/amu. The primary particles are resolved into groups according to their charge (p, He, CNO, Medium Z, Heavy Z) using both active and passive components integrated into the detector. The principal part of SOFCAL is a thin ionization calorimeter that measures the electromagnetic cascades that result from these energetic particles interacting in the detector. The calorimeter is divided into two sections: a thin passive emulsion/x-ray film calorimeter, and a fiber calorimeter that uses crossing layers of small scintillating optical fibers to sample the energy deposition of the cascades. The energy determination is made by fitting the fiber data to transition curves generated by Monte Carlo simulations. The fiber data must first be calibrated using the electron counts from the emulsion plates in the calorimeter for a small number of events. The technique and results of this calibration will be presented together with samples of the data from a balloon flight.

Christl, M. C.↗