Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Adhesively Bonded Copper and Polyimide for Flexible Printed Circuit Boards: A Data-Driven Degradation Study Under Accelerated Aging

The long-term durability of polyimide laminated adhesive based flexible printed circuit boards (PCBs) is critical to the microelectronics industry. The interface of the adhesive layer binding the polyimide and copper layers is particularly vulnerable since decreased bonding strength can lead to deadhesion, performance loss, and premature device failure. Here, in this study, adhesive-bonded polyimide and copper samples are subjected to 1000 h of damp heat exposure (85 °C/85%RH) to evaluate the impact of moisture and copper inclusion on the adhesive bonding performance. Significant copper diffusion through the adhesive layer is observed, which, combined with moisture uptake, is found to substantially weaken interfacial adhesion in copper-containing samples, thereby reducing device lifetime. Observed surface and bulk material changes are correlated to adhesion strength using the network structural equation modeling (netSEM) approach, resulting in a robust predictive model of performance degradation based on measurable materials properties.

Chemistry↗

Mechanical detwinning device for anisotropic resistivity measurements in samples requiring dismounting for particle irradiation

Uniaxial stress is used to detwin samples of orthorhombic iron based superconductors to study their intrinsic electronic anisotropy. Here we describe the development of a new detwinning setup enabling variable-load stress-detwinning with easy sample mounting/dismounting without the need to re-solder the contacts. It enables the systematic study of the anisotropy evolution as a function of an external parameter when the sample is modified between the measurements. In our case, the external parameter is the dose of 2.5 MeV electron irradiation at low temperature. We illustrate the approach by studying resistivity anisotropy in single crystals of Ba 1-x K x Fe 2 As 2 at x =0.25 where the much discussed unusual re-entrance of tetragonal C 4 phase, C 4 → C 2 → C 4 , is observed on cooling. With the described technique we found a significant anisotropy increase in C 2 phase after electron irradiation with dose of 2.35 C/cm 2 .

47 OTHER INSTRUMENTATION↗

Time-resolved cryogenic electron tomography for the study of transient cellular processes

Cryogenic electron tomography (cryo-ET) is the highest resolution imaging technique applicable to the life sciences, enabling sub-nanometer visualization of specimens preserved in their near native states. The rapid plunge freezing process used to prepare samples lends itself to time-resolved studies, which researchers have pursued for in vitro samples for decades. Here, we focus on developing a freezing apparatus for time-resolved studies in situ. The device mixes cellular samples with solution-phase stimulants before spraying them directly onto an electron microscopy grid that is transiting into cryogenic liquid ethane. By varying the flow rates of cell and stimulant solutions within the device, we can control the reaction time from tens of milliseconds to over a second prior to freezing. In a proof-of-principle demonstration, the freezing method is applied to a model bacterium, Caulobacter crescentus, mixed with an acidic buffer. Through cryo-ET we resolved structural changes throughout the cell, including surface-layer protein dissolution, outer membrane deformation, and cytosolic rearrangement, all within 1.5 seconds of reaction time. This new approach, Time-Resolved cryo-ET (TR-cryo-ET), enhances the capabilities of cryo-ET by incorporating a sub-second temporal axis and enables the visualization of induced structural changes at the molecular, organelle, or cellular level.

59 BASIC BIOLOGICAL SCIENCES↗

Modular system and method for mercury speciation in a fluid sample

Modular Hg analysis devices and methods are described for use in mercury speciation protocols. Modules can be selected and removably connected to one another to specifically target mercury species in a sample so as to accurately determine the presence or quantity of different mercury species in a fluid sample. Modules can include reductants for reducing inorganic mercury to form elemental mercury and amalgamation agents to capture the elemental mercury. Modules can include filters for capture of particulates as well as capture agents, e.g., solid phase extraction agents, for capture of organic mercury species.

Looney, Brian B.↗

Nanoscale optical tomography with cathodoluminescence spectroscopy

In one aspect, a cathodoluminescence (CL) spectroscopic tomography device includes a sample stage to support a sample. An electron beam source scans an electron beam over the sample to yield light emission by the sample. A reflective element directs the light emission by the sample to a light detector. A controller controls operation of the sample stage, the electron beam source, and the light detector. In one aspect, a CL spectroscopic tomography device includes an electron beam source which directs an electron beam at an object to yield an emission by the object. A detector detects the emission. A controller receives information from the detector related to the detected emission. The controller derives a two-dimensional (2D) CL map from the information related to the detected emission, and derives a three-dimensional (3D) CL tomogram from the 2D CL map.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thin film design of amorphous hafnium oxide nanocomposites enabling strong interfacial resistive switching uniformity

A design concept of phase-separated amorphous nanocomposite thin films is presented that realizes interfacial resistive switching (RS) in hafnium-oxide-based devices. The films are formed by incorporating an average of 7% Ba into hafnium oxide during pulsed laser deposition at temperatures ≤400°C. The added Ba prevents the films from crystallizing and leads to ~20-nm-thin films consisting of an amorphous HfO x host matrix interspersed with ~2-nm-wide, ~5-to-10-nm-pitch Ba-rich amorphous nanocolumns penetrating approximately two-thirds through the films. This restricts the RS to an interfacial Schottky-like energy barrier whose magnitude is tuned by ionic migration under an applied electric field. Resulting devices achieve stable cycle-to-cycle, device-to-device, and sample-to-sample reproducibility with a measured switching endurance of ≥10 4 cycles for a memory window ≥10 at switching voltages of ±2 V. Each device can be set to multiple intermediate resistance states, which enables synaptic spike-timing–dependent plasticity. The presented concept unlocks additional design variables for RS devices.

36 MATERIALS SCIENCE↗

Analytical comparisons of handheld LIBS and XRF devices for rapid quantification of gallium in a plutonium surrogate matrix

This work compares a portable laser-induced breakdown spectroscopy (LIBS) analyzer to a portable X-ray fluorescence (XRF) device for quantification of gallium (Ga) in a plutonium surrogate matrix of cerium (Ce) for the first time. Calibration methods are developed with spectra of Ce–Ga samples from both devices. Here, metrics such as limit of detection (LoD) and mean average percent error (MAPE) are examined to evaluate calibration performance. While the portable LIBS device can yield a nearly instantaneous analytical measurement, its accuracy is hampered by self-absorption. By employing a self-absorption correction and increasing gating delay, LIBS calibrations with errors in the low single percents and LoDs of 0.1% Ga were constructed. The XRF device produces calibrations with superlative sensitivity, yielding LoDs for gallium in the low tens of parts-per-million (ppm), two orders of magnitude lower than the corrected LIBS models. However, a clear trade-off of measurement fidelity is established between the instantaneous analysis of the LIBS device and the minutes-long XRF measurement yielding superior detection limits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spin and Charge Interconversion in Dirac-Semimetal Thin Films

We use spin torque ferromagnetic resonance and ferromagnetic-resonance-driven spin pumping to detect spin-charge interconversion at room temperature in heterostructure devices that interface an archetypal Dirac semimetal, Cd 3 As 2 , with a metallic ferromagnet, Ni 0.80 Fe 0.20 (permalloy). Angle-resolved photoemission directly reveals the Dirac-semimetal nature of the samples prior to device fabrication and high-resolution transmission electron microscopy is used to characterize the crystalline structure and the relevant heterointerfaces. We find that the spin-charge interconversion efficiency in Cd 3 As 2 /permalloy heterostructures is comparable to that in heavy metals and that it is enhanced by the presence of an interfacial oxide. Spin torque ferromagnetic resonance measurements reveal an in-plane spin polarization regardless of an oxidized or pristine interface. We discuss the underlying mechanisms for spin-charge interconversion by comparing our results with first principles calculations and conclude that extrinsic mechanisms dominate the observed phenomena. Our results indicate a need for caution in interpretations of spin-transport and spin-charge conversion experiments in Cd 3 As 2 devices that seek to invoke the role of topological Dirac and Fermi arc states.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Using electron channeling contrast imaging to inform and improve the growth of high-efficiency GaAs solar cells on nanopatterned GaAs substrates

Patterned substrates provide opportunities for reducing the cost of high-efficiency III-V devices by incorporating mechanically weak layers beneficial for substrate reuse (e.g. by spalling). In this work, the functionality of electron channeling contrast imaging (ECCI) as a tool to efficiently understand and mitigate defect formation is exemplified by developing a process in which high-quality III-V material can be grown on nanopatterned GaAs substrates. Reactive ion etching used in the patterning process was found to damage the GaAs substrate surface, leading to the formation of stacking faults in the epitaxial material as observed by ECCI. Etching the patterned substrates in a 1 NH4OH: 1 H2O2: 50 DI H2O solution for 10 s prior to growth removed the substrate surface damage and stacking faults were no longer present. Growth of solar cell device structures initially produced samples with many macroscale flaws creating shunts in the devices, which complicated the assessment of material quality by device measurements. However, ECCI revealed that the epitaxial material surrounding macroscale flaws was free from any crystallographic defects such as stacking faults and threading dislocations. With this knowledge, we focused on refining the patterning process to eliminate the macroscale flaws. Solar cells were then grown on the improved nanopatterned substrates and exhibited device structures with defect densities less than 5 x 105 cm -2 and average conversion efficiency of 24.8%, nearly identical to devices grown on unpatterned epi-ready substrates (25.0%).

14 SOLAR ENERGY↗

Porous membrane enabled mass spectrometry characterization of microfluidic devices

A system for sampling a liquid includes a sample fluid conduit including a membrane having pores. The membrane prevents the passage of the sample liquid through the pores at a first pressure of the sample liquid in the sample fluid conduit. A surface sampling capture probe has a distal end. The capture probe includes a solvent supply conduit and a solvent exhaust conduit. A solvent composition flowing at the distal end of the capture probe establishes a liquid junction with the membrane and establishes a second pressure within the liquid junction at the membrane. The second pressure is lower than the first pressure. Sample liquid will be drawn through the pores of the membrane by the second pressure at the liquid junction. A method for sampling a liquid and for performing chemical analysis on a liquid are also disclosed.

Cahill, John F.↗

Porous membrane enabled mass spectrometry characterization of microfluidic devices

A system for sampling a liquid includes a sample fluid conduit including a membrane having pores. The membrane prevents the passage of the sample liquid through the pores at a first pressure of the sample liquid in the sample fluid conduit. A surface sampling capture probe has a distal end. The capture probe includes a solvent supply conduit and a solvent exhaust conduit. A solvent composition flowing at the distal end of the capture probe establishes a liquid junction with the membrane and establishes a second pressure within the liquid junction at the membrane. The second pressure is lower than the first pressure. Sample liquid will be drawn through the pores of the membrane by the second pressure at the liquid junction. A method for sampling a liquid and for performing chemical analysis on a liquid are also disclosed.

Cahill, John F.↗

Complete Strain Mapping of Nanosheets of Tantalum Disulfide

Quasi-two-dimensional (quasi-2D) materials hold promise for future electronics because of their unique band structuresthat result in electronic and mechanical properties sensitive to crystal strains in all three dimensions. Quantifying crystal strain is a prerequisite to correlating it with the performance of the device, and calls for high resolution but spatially resolved rapid characterization methods. Here we show that using fly-scan nano X-ray diffraction we can accomplish a tensile strain sensitivity below 0.001% with a spatial resolution of better than 80 nm over a spatial extent of 100 µm on quasi 2D flakes of 1T-TaS2. Coherent diffraction patterns were collected from a ~100 nm thick sheet of 1T-TaS2 by scanning 12keV focused X-ray beam across and rotating the sample. We demonstrate that the strain distribution around micron and sub-micron sized ‘bubbles’ that are present in the sample may be reconstructed from these images. The experiments use state of the art synchrotron instrumentation, and will allow rapid and non-intrusive strain mapping of thin film samples and electronic devices based on quasi 2D materials.

nano X-ray diffraction↗

Carrier recombination parameters in diamond after surface boron implantation and annealing

In this study, an optical pump–probe technique was used to detect spatial distribution of carrier lifetimes across the thickness of a high-quality diamond device structure. Two samples with as-received and boron implanted surfaces were compared to assess the role of implantation and related processing on carrier recombination mechanisms. It was found that the two implanted surfaces show very different behaviors despite undergoing the same treatment. At one of the surfaces, carrier lifetimes remained relatively unchanged, indicating surface recombination rates in the 102–103 cm/s range. At the other surface, carrier lifetimes were almost a magnitude lower and correlated with the locally detected nitrogen vacancy defect that was attributed to the elevated concentration of residual nitrogen.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bayesian Framework for Multi-Timescale State Estimation in Low-Observable Distribution Systems

To support the smart grid paradigm, there has been a significant increase in sensor deployments and metering infrastructure in distribution systems. However, the measurements provided by these sensors and metering devices are typically sampled at different rates and could suffer from losses during the aggregation process. It is crucial to effectively reconcile the time-series measurements for a reliable state estimation. While weighted least squares has been the traditional approach for state estimation, sparsity-based approaches like matrix completion have become popular due to their superior performance in low-observability conditions. This paper proposes a Bayesian framework for both multi-timescale data aggregation and matrix completion based state estimation. Specifically, the multiscale time-series data aggregated from heterogenous sources are reconciled using a multitask Gaussian process that exploits the spatio-temporal correlations. Here, the resulting consistent timeseries alongwith the confidence bound on the imputations are fed into a Bayesian matrix completion method augmented with linearized power-flow constraints to accurately estimate the states in low-observability conditions. Results on three phase unbalanced IEEE 37 and IEEE 123 bus test systems reveal the superior performance of the proposed Bayesian framework. The computational complexity for the proposed Bayesian framework is also quantified.

42 ENGINEERING↗

Performance of plane wavefront Fizeau interferometers in power spectral density measurements with tilted plane optics

Binary pseudo-random array (BPRA) test samples are useful devices for calibrating the instrument transfer function (ITF) of Fizeau interferometers, interferometric microscopes, and other optical and non-optical surface and wavefront metrology instruments. The intrinsic white noise character of the power spectral density (PSD) function of the BPRA pattern simplifies the extraction of the ITF from the measured PSD. The ITF determined in a dedicated calibration experiment can be used to reconstruct the surface height profile from the measured data, effectively enhancing the instrument’s spatial resolution. For a high confidence reconstruction procedure, a reliable analytical model of the IFT is desirable. Usually, the model accounts for the contributions to the ITF related the imperfections of the instrument’s optical and detector systems. Here, we experimentally demonstrate that in the case of surface height metrology with Fizeau interferometers, the PSD measurements and, therefore, the efficacy of the ITF calibration of the tool, are strongly affected by the instrument data acquisition and processing procedures, as well as by the shape of the optic under test and its alignment with respect to the interferometer.

Yashchuk, V V↗

KBase Narrative - Atacama Trench & Sn Clemente 2018 cruise Metagenomes -Decontamination through Metagenomic Fractionation and analysis of Metabolic Potential-

Deep-sea microbiomes sampled with traditional or pressure-retaining instrumentation A fundamental property of life in the sea is that with increasing depth must come increased adaptation to elevated hydrostatic pressures. This project aims to assess technology for the accurate characterization of microbial biodiversity and biochemistry at greater depths, and validate its use in some of the deepest and least-explored waters in the Ocean: Hadal Trench. Compared to the 0.1 megapascal (MPa) of surface waters, organisms inhabiting at the average depth of the Ocean (3800 m) have to deal with pressures of 38 MPa (5,500 psi). The effects of these high pressure have been most thoroughly investigated in microorganisms, where it has been found to affect membrane integrity and transport, cytoskeletal assembly and both DNA and protein synthesis. We will explore the diversity and activity of microorganisms from 2000 m to >8,000 m depths within the highly productive water column of hadal trenches, comparing seawater samples obtained with and without substantial pressure changes during recovery. A pressure retaining device was used to sample the microbial communities of the watercolumn with reduced decompression during retreival (Peoples et. al., 2019). References: Peoples LM, Norenberg M, Price D, McGoldrick M, Novotny M, Bochdansky A, Bartlett DH. A full-ocean-depth rated modular lander and pressure-retaining sampler capable of collecting hadal-endemic microbes under in situ conditions. Deep Sea Research Part I: Oceanographic Research Papers. 2019 Jan 1;143:50-7.

Plominsky, Alvaro M.↗