Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sampling frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Air Classification of Forestry Residues for Fast Pyrolysis

Understanding critical biomass attributes through efficient fractionation is crucial for advancing sustainable pyrolysis for renewable energy and chemical production. This study investigates the intricate relationship between biomass preprocessing and pyrolysis product yields, employing the air classification technique for the treatment of loblolly pine residues with varying moisture content. A comprehensive exploration of the physicochemical properties of air-classified loblolly pine informs a sophisticated pyrolysis simulation model. Given the complex and multifaceted nature of biomass pyrolysis, operating across diverse temporal and spatial scales, a pyrolysis kinetics-based CFD–DEM simulation method is employed to predict product yields. Results showed that the elevated moisture content amplifies particle adhesiveness, necessitating augmented air velocities for effective separation, thereby influencing the efficiency of the separation process. While carbon and hydrogen contents exhibit relative stability across diverse moisture contents and blower frequencies, the oxygen content undergoes noticeable changes. For example, the oxygen contents were measured as 29.2 and 38.6 wt% in the light fraction of 30% moisture content sample at blower frequencies of 10 and 20 Hz, respectively. An intriguing finding emerges from pyrolysis simulation, indicating that a lower blower frequency in air classification moderately enhances bio-oil yield and significantly improves its quality, particularly in terms of water content. For instance, the water content in the bio-oil was about 1.5% and 10% in the heavy and light fractions, respectively from 10% moisture sample under 15 Hz blower frequency.

09 - BIOMASS FUELS↗

Structural and thermodynamic effects of hydration in Na-zeolite A (LTA) from low-temperature heat capacity

Zeolite A (Linde Type A; LTA) is an industrially important porous mineral that has recently been shown to exhibit framework flexibility upon changes in hydration level. Here, to investigate the flexibility transition from a thermodynamic perspective, we have performed heat capacity measurements on sodium zeolite A at seven incremental hydration levels ranging from zero to equilibrium with ambient air. Excess low-frequency vibrations beyond the predictions of the Debye model are found in all samples, and the frequency of these vibrations increases as a function of hydration level. This suggests that an increase in hydration causes a decrease in at least one type of framework flexibility for sodium zeolite A. In addition, a subtle excess heat capacity contribution from 150 to 280 K is observed only for low and intermediate hydration levels, which may arise from a transformation tied to framework flexibility previously observed in zeolite A via gas absorption calorimetry. Values of the standard thermodynamic functions C p,m °, Δ 0 T S m °, Δ 0 T H m °, and Φ m ° are also reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Poisson tensor completion parametric estimator

We introduce the Poisson tensor completion (PTC) estimator that exploits inter-sample relationships to compute a low-rank Poisson tensor decomposition of the frequency histogram for samples of a multivariate distribution. Our crucial observation is that the histogram bins are an instance of a space partitioning of counts and thus can be identified with a spatial non-homogeneous Poisson process. The Poisson tensor decomposition leads to a completion of the mean measure over all bins—including those containing few to no samples—and leads to our proposed estimator. A Poisson tensor decomposition models the underlying distribution of the count data and guarantees non-negative estimated values obviating the need for additional constraints to ensure non-negativity. Furthermore, we demonstrate that our PTC estimator is a substantial improvement over standard histogram-based estimators for sub-Gaussian probability distributions because of the concentration of norm phenomenon.

97 MATHEMATICS AND COMPUTING↗

Sensing depths in frequency domain thermoreflectance

In this work, a method is developed to calculate the length into a sample to which a Frequency Domain Thermoreflectance (FDTR) measurement is sensitive. Sensing depth and sensing radius are defined as limiting cases for the spherically spreading FDTR measurement. A finite element model for FDTR measurements is developed in COMSOL multiphysics and used to calculate sensing depth and sensing radius for silicon and silicon dioxide samples for a variety of frequencies and laser spot sizes. The model is compared to experimental FDTR measurements. Design recommendations for sample thickness are made for experiments where semi-infinite sample depth is desirable. For measurements using a metal transducer layer, the recommended sample thickness is three thermal penetration depths, as calculated from the lowest measurement frequency.

36 MATERIALS SCIENCE↗

Multiple Mutations Associated with Emergent Variants Can Be Detected as Low-Frequency Mutations in Early SARS-CoV-2 Pandemic Clinical Samples

Genetic analysis of intra-host viral populations provides unique insight into pre-emergent mutations that may contribute to the genotype of future variants. Clinical samples positive for SARS-CoV-2 collected in California during the first months of the pandemic were sequenced to define the dynamics of mutation emergence as the virus became established in the state. Deep sequencing of 90 nasopharyngeal samples showed that many mutations associated with the establishment of SARS-CoV-2 globally were present at varying frequencies in a majority of the samples, even those collected as the virus was first detected in the US. A subset of mutations that emerged months later in consensus sequences were detected as subconsensus members of intra-host populations. Spike mutations P681H, H655Y, and V1104L were detected prior to emergence in variant genotypes, mutations were detected at multiple positions within the furin cleavage site, and pre-emergent mutations were identified in the nucleocapsid and the envelope genes. Because many of the samples had a very high depth of coverage, a bioinformatics pipeline, “Mappgene”, was established that uses both iVar and LoFreq variant calling to enable identification of very low-frequency variants. This enabled detection of a spike protein deletion present in many samples at low frequency and associated with a variant of concern.

60 APPLIED LIFE SCIENCES↗

Impacts of Non-Ideal Back Contact on Capacitance Measurements in CdTe Solar Cells

CdTe solar cells suffer from a non-ideal back contact which can strongly affect the equivalent circuit model and complicate capacitance measurements. Here, five different back contact materials are deposited on identical CdTe absorbers and their influence on capacitance measurements is characterized. A five-element equivalent circuit model is shown to represent a CdTe solar cell with a non-ideal back contact, and capacitance-frequency (C-f) measurements on each sample clearly show the influence of this contact. Capacitance-voltage (C-V) measurements on each sample show the influence of frequency on measured capacitance. In the AlGaOx/Au sample, temperature dependent C-fs show the back barrier height to be 240 meV, and ongoing measurements will give a comparison of back barrier heights for all samples. This study provides insight into the efficacy of various back contacts and highlights potential errors in the interpretation of capacitance measurements due to the presence of the back contact.

cadmium compounds↗

Retrospective on decadal progress of the NOAA/NPS ocean noise reference station network

The National Oceanic and Atmospheric Administration (NOAA), in partnership with the U.S. National Park Service (NPS), established the Ocean Noise Reference Station Network (NRS) in 2014 as a foundational component of NOAA’s Ocean Noise Strategy. This long-term effort aims to characterize baseline ocean ambient sound conditions across diverse marine environments and to inform management of noise impacts on protected species and habitats within U.S. waters. The NRS is now composed of 13 autonomous passive acoustic monitoring stations strategically positioned across the U.S. Exclusive Economic Zone (EEZ), extending from Arctic regions to tropical waters in depths ranging from 33 to 4,790 m. These locations include several National Marine Sanctuaries and National Parks, such as the recently designated Chumash Heritage National Marine Sanctuary off the coast of California. Each station is equipped to continuously sample low-frequency underwater sound at five kHz, enabling the detection of anthropogenic, geophysical, and biological acoustic signals. To date the network has sampled over 72 years of calibrated acoustic data. The spatial breadth and consistent methodology of the NRS allow for comparative acoustic assessments across diverse marine ecosystems. In addition to applied research functions, the NRS has served as a platform for education and training, offering opportunities for students to develop skills for marine science and data analysis. Looking forward, the NRS project team is focused on network expansion, improved data delivery, and broader integration with collaborative scientific initiatives. NRS recordings are being archived in partnership with NOAA’s National Centers for Environmental Information to enhance accessibility and long-term utility. Efforts are underway to develop standardized metadata and summary products to accompany raw audio files, making the data more usable for a wide range of stakeholders in the ocean science community. The NRS is evolving into a fully integrated national framework for ocean sound monitoring that supports scientific inquiry, management decision-making, national security interests, and public engagement with ocean acoustic environments.

Long-term monitoring↗

Impacts of Non-Ideal Back Contact on Capacitance Measurements in CdTe Solar Cells

CdTe solar cells suffer from a non-ideal back contact which can strongly affect the equivalent circuit model and complicate capacitance measurements. Here, five different back contact materials are deposited on identical CdTe absorbers and their influence on capacitance measurements is characterized. A five-element equivalent circuit model is shown to represent a CdTe solar cell with a non-ideal back contact, and capacitance-frequency (C-f) measurements on each sample clearly show the influence of this contact. Capacitance-voltage (C-V) measurements on each sample show the influence of frequency on measured capacitance. In the AlGaOx/Au sample, temperature dependent C-fs show the back barrier height to be 240 meV, and ongoing measurements will give a comparison of back barrier heights for all samples. This study provides insight into the efficacy of various back contacts and highlights potential errors in the interpretation of capacitance measurements due to the presence of the back contact.

14 SOLAR ENERGY↗

Strategies to perform magnetization reversals in ferromagnets

Systems and methods for reversing a magnetization in a ferromagnet include a nanometer-scale cylindrical ferromagnetic sample having a height to diameter aspect ratio on the order of 2 or greater. A temporally-varying external field comprising an r.f. Pi pulse is applied to the ferromagnetic sample to cause a precession magnetization vector inclined at an angle with respect to the longest axis of the ferromagnetic sample to continuously rotate around the longest axis. One or more parameters of the temporally-varying external field is continuously adjusted based on at least magnetization dynamics of the ferromagnetic sample and/or an angular dependence of a precession frequency of the ferromagnetic sample.

Ketterson, John B.↗

Synthesis, Crystal Structure, and Cooperative 3d–5d Magnetism in Rock Salt Type Li 4 NiOsO 6 and Li 3 Ni 2 OsO 6

Two new transition metal oxides with the nominal chemical compositions of Li 4 NiOsO 6 and Li 3 Ni 2 OsO 6 were successfully synthesized. Both compounds crystallize in an ordered rock salt structure type in the monoclinic C2/m space group. The crystal structures were determined using both synchrotron X-ray and time-of-flight neutron, powder diffraction data. In both phases, Ni2+ ions are present while oxidation states of osmium are +6 and +5 in Li 4 NiOsO 6 and Li 3 Ni 2 OsO 6 , respectively. Ni2+ ions in the hypothetical fully ordered phase form a honeycomb arrangement in the ab crystallographic plane and these hexagons are centered by osmium ions. Furthermore, the magnetic layers are separated along the c axis by the octahedra, which are centered by Li+ (or Li+/Ni 2+ , depending on the chemical compositions). Crystal structure refinements reveal that there is some degree of mixed occupancy in cationic positions. Temperature dependent magnetic susceptibility data for both phases show ferrimagnetic transitions with predominant antiferromagnetic (AFM) interactions among 3d electrons of nickel and Sd electrons of osmium. Iso-thermal magnetization loops as a function of the applied magnetic field below the transition temperatures confirm the ferrimagnetic nature in magnetic transitions. Temperature dependent heat capacity data, however, did not exhibit any anomaly in either phase, indicating the absence of long-range magnetic ordering. The lack of long-range order for both Os 5+ and Os 6+ -based compounds was also confirmed by low temperature neutron diffraction data down to 10 K. Temperature dependent AC magnetic susceptibility data in various frequencies for both samples indicate that Li 4 NiOsO 6 exhibits spin-glass-like behavior, while the transition temperature for Li 3 Ni 2 OsO 6 is nearly frequency independent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Search and identification of transient and variable radio sources using MeerKAT observations: a case study on the MAXI J1820+070 field

ABSTRACT Many transient and variable sources detected at multiple wavelengths are also observed to vary at radio frequencies. However, these samples are typically biased towards sources that are initially detected in wide-field optical, X-ray, or gamma-ray surveys. Many sources that are insufficiently bright at higher frequencies are therefore missed, leading to potential gaps in our knowledge of these sources and missing populations that are not detectable in optical, X-rays, or gamma-rays. Taking advantage of new state-of-the-art radio facilities that provide high-quality wide-field images with fast survey speeds, we can now conduct unbiased surveys for transient and variable sources at radio frequencies. In this paper, we present an unbiased survey using observations obtained by MeerKAT, a mid-frequency (∼GHz) radio array in South Africa’s Karoo Desert. The observations used were obtained as part of a weekly monitoring campaign for X-ray binaries (XRBs) and we focus on the field of MAXI J1820+070. We develop methods to efficiently filter transient and variable candidates that can be directly applied to other data sets. In addition to MAXI J1820+070, we identify four likely active galactic nuclei, one source that could be a Galactic source (pulsar or quiescent XRB) or an AGN, and one variable pulsar. No transient sources, defined as being undetected in deep images, were identified leading to a transient surface density of <3.7 × 10−2 deg−2 at a sensitivity of 1 mJy on time-scales of 1 week at 1.4 GHz.

Rowlinson, A. (ORCID:0000000211957022)↗

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

A Nonlinear Least Squares Phasor Estimation Algorithm with a Trust Metric

The paper presents a separable nonlinear least squares (NLLS)-based approach for estimation of fundamental-frequency phasors from sampled point-on-wave measurements. An analytical connection is established between the NLLS cost function and the discrete Fourier transform (DFT)-based periodogram of the input signal. This periodogram-based interpretation of the cost function offers an intuitive and easy-to-implement solution for the frequency estimate. Using the residual error of the NLLS-fit, the paper also presents an insightful measure for ascertaining the quality of the phasor estimates and their validity, especially for data windows containing signal transients.

Chatterjee, Kaustav↗

Temperature-dependent complex dielectric permittivity: a simple measurement strategy for liquid-phase samples

Abstract Microwaves (MWs) are an emerging technology for intensified and electrified chemical manufacturing. MW heating is intimately linked to a material’s dielectric permittivity. These properties are highly dependent on temperature and pressure, but such datasets are not readily available due to the limited accessibility of the current methodologies to process-oriented laboratories. We introduce a simple, benchtop approach for producing these datasets near the 2.45 GHz industrial, medical, and scientific (ISM) frequency for liquid samples. By building upon a previously-demonstrated bireentrant microwave measurement cavity, we introduce larger pressure- and temperature-capable vials to deduce temperature-dependent permittivity quickly and accurately for vapor pressures up to 7 bar. Our methodology is validated using literature data, demonstrating broad applicability for materials with dielectric constant ε' ranging from 1 to 100. We provide new permittivity data for water, organic solvents, and hydrochloric acid solutions. Finally, we provide simple fits to our data for easy use.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SAIL-Isotopologue (SAIL-iso) Field Campaign Report

The SAIL-iso project took place from November 19, 2022 to June 3, 2023 as part of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Surface Atmosphere Integrated Field Laboratory (SAIL) project at the main project site in Gothic, Colorado. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in a remote mountainous watershed. Water vapor isotopologue and humidity measurements were determined using a Los Gatos Research Triple Water Vapor Isotope Analyzer (TWVIA). The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through Teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. Multiple sources of uncertainty are introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) Vienna Standard Mean Ocean Water – Standard Light Antarctic Precipitation (VSMOW-SLAP) calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ 18 O.

54 ENVIRONMENTAL SCIENCES↗

Water vapor isotopic composition during TRACER IOP

The TRACER-Iso project took place from June 1 to September 30, 2022 as part of the intensive observation period (IOP) of the Tracking Aerosol Convection Interactions (TRACER) project at the main project site at the La Porte, Texas, municipal airport. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in deep convection in a polluted urban setting. Water vapor isotopologue and humidity measurements were determined using a Picarro L2130 Water Vapor Isotope Analyzer. The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, and a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. There are multiple sources of uncertainty introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) VSMOW-SLAP calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ18O.

54 ENVIRONMENTAL SCIENCES↗

High signal-to-noise ratio differential conductance spectroscopy

The scanning tunneling microscope (STM) has enabled manipulation and interrogation of surfaces with atomic-scale resolution. Electronic information about a surface is obtained by combining the imaging capability of the STM with scanning tunneling spectroscopy, i.e., measurement of current-voltage (I/V) characteristics of the surface. We propose a change in the STM feedback loop that enables capturing a higher quality dI/dV image. A high frequency dither voltage is added to the bias voltage of the sample, and the fundamental frequency component of the resulting current is demodulated. The in-phase component of this signal is then plotted along with the X and Y position data, constructing the dI/dV image. Here, we show that by incorporating notch filters in the STM feedback loop, we may utilize a high-amplitude dither voltage to significantly improve the quality of the obtained dI/dV image.

42 ENGINEERING↗

Fast estimation of the look-elsewhere effect using Gaussian random fields

Abstract We discuss the use of Gaussian random fields to estimate the look-elsewhere effect correction. We show that Gaussian random fields can be used to model the null-hypothesis significance maps from a large set of statistical problems commonly encountered in physics, such as template matching and likelihood ratio tests. Some specific examples are searches for dark matter using pixel arrays, searches for astronomical transients, and searches for fast-radio bursts. Gaussian random fields can be sampled efficiently in the frequency domain, and the excursion probability can be fitted with these samples to extend any estimation of the look-elsewhere effect to lower p values. In addition, in cases where the Gaussian random field is stationary and the parameter space is Euclidean, the look-elsewhere effect correction can be computed analytically. We demonstrate these methods using two example template matching problems. Finally, we apply these methods to estimate the trial factor of a $$4^3$$ 4 3 accelerometer array for the detection of dark matter tracks in the Windchime project. When a global significance of $$3\sigma $$ 3 σ is required, the estimated trial factor for such an accelerometer array is $$10^{14}$$ 10 14 for a one-second search, and $$10^{22}$$ 10 22 for a 1-year search.

Qin, Juehang (ORCID:0000000182288949)↗