Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6{<=}pitch{<=}3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving coronary artery phantom acquired with the ECG-triggered high-pitch scan mode were visually free from motion artifacts at heart rates of 60 and 70 bpm. However, image quality started to deteriorate for higher heart rates. At equivalent image quality, the ECG-triggered high-pitch scan mode demonstrated lower radiation dose than other cardiac scan techniques on the same DSCT equipment (25% and 60% dose reduction compared to ECG-triggered sequential step-and-shoot and ECG-gated spiral with x-ray pulsing). Conclusions: A high-pitch (up to pitch=3.2), high-temporal-resolution (up to 75 ms) dual-source CT scan mode produced equivalent image quality relative to single-source scans using a more typical pitch value (pitch=1.0). The resultant reduction in the overall acquisition time may offer clinical advantage for cardiovascular, trauma, and pediatric CT applications. In addition, ECG-triggered high-pitch scanning may be useful as an alternative to ECG-triggered sequential scanning for patients with low to moderate heart rates up to 70 bpm, with the potential to scan the heart within one heart beat at reduced radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An analysis of the effect of aperture shapes in reducing facsimile camera aliasing.

Optical-mechanical scanning techniques are frequently employed in instruments specifically designed to spectrally or radiometrically characterize variations in scene brightness. The effect of line scan sampling on the spatial detail of the reconstructed images has, therefore, received little attention. Emphasis of some recent applications of optical-mechanical scanning techniques is, however, on the spatial characterization of the scene which, as is shown here, can be severely degraded by aliasing generated in common scanner designs. The characteristics of aliasing are analyzed to establish quantitative bounds, and photosensor aperture shaping and line scan spacing are investigated as a means for reducing this degradation.

Katzberg, S. J.↗

Nonlinear optical characterization of ZnS thin film synthesized by chemical spray pyrolysis method

ZnS thin film was prepared by Chemical Spray Pyrolysis (CSP) method. The sample was characterized by X-ray diffraction method and Z scan technique. XRD pattern showed that ZnS thin film has hexagonal structure with an average size of about 5.6nm. The nonlinear optical properties of ZnS thin film was studied by open aperture Z-Scan technique using Q-switched Nd-Yag Laser at 532nm. The Z-scan plot showed that the investigated ZnS thin film has saturable absorption behavior. The nonlinear absorption coefficient and saturation intensity were also estimated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An investigation of photosensor aperture shaping in facsimile cameras

Optical-mechanical scanning techniques are generally employed in instruments specifically designed to spectrally or radiometrically characterize variations in scene brightness. The effect of aliasing, which can be caused by line scan sampling, on the spatial detail of the reconstructed image has, therefore, been of little concern. Emphasis of some recent applications of optical-mechanical scanning techniques in facsimile cameras is, however, on the spatial characterization of the scene which, as is shown, can be severely degraded by aliasing. The characteristics of aliasing are analyzed to establish quantitative bounds, and photosensor aperture shaping and line scan spacing are investigated as a means for reducing this degradation.

Katzberg, S. J.↗

Optical properties of petal-like aggregated nanocrystalline zinc oxide synthesized by laser ablation

Highlights: Black-Right-Pointing-Pointer Petal like ZnO nanocrystals are synthesized by high frequency laser ablation in water. Black-Right-Pointing-Pointer Optical band gap of ZnO nanocrystals was tunable by changing the laser pulse energy. Black-Right-Pointing-Pointer Nonlinear optical properties and limiting threshold were obtained by Z-scan technique. -- Abstract: The results of the investigations carried out on the third-order nonlinearity in zinc oxide (ZnO) nanocrystals (NCs) by Z-scan technique are included in this paper. ZnO NCs show negative nonlinearity and good nonlinear absorption behavior at 532 nm. The third-order optical susceptibility {chi}(3) increases with enlargement of NCs due to the size dependent enhancement of exciton oscillator strength. The synthesis of ZnO NCs was performed by laser ablation from a high-purity metallic target of Zn in distilled water medium. For the ablation process, a high frequency pulsed Nd:YAG laser was employed operating at 532 nm with 100 ns pulse duration. UV-vis absorption spectroscopy illustrated the enhancement of the size of ZnO NCs upon increasing the laser pulse energy applied in ablation process. Accordingly the corresponding optical band gap (E{sub g}) decrease by increasing the size of NCs. X-ray diffraction (XRD) associated with transmission electron microscopy (TEM) was utilized to characterize the crystalline phase and also for determining the ZnO NCs morphology.

36 MATERIALS SCIENCE↗

Nonlinear optical properties of ZnO/poly (vinyl alcohol) nanocomposite films

Extensive studies have already been reported on the optical characteristics of ZnO/polymer nanocomposite films, using a variety of polymers including transparent polymers such as polystyrene, polymethyl methacrylate etc and many interesting results have been established regarding the non linear optical characteristics of these systems. Poly (vinyl alcohol)(PVA) is a water soluble polymer. Though the structural and optical studies of ZnO/PVA nanocomposite films have already been investigated, there are no detailed reports on the nonlinear optical characteristics of ZnO/PVA nanocomposite films, irrespective of the fact that these nanocomposite films can be synthesized using quite easy and cost effective methods. The present work is an attempt to study in detail the nonlinear optical behaviour of ZnO/PVA nanocomposite films using Z-scan technique. Highly transparent ZnO/PVA nanocomposite films were prepared from the ZnO incorporated PVA solution in water using spin coating technique. The ZnO nanoparticles were synthesized by the simple chemical route at room temperature. High-resolution transmission electron microscopy studies show that the ZnO nanoparticles are of size around 10 nm. The ZnO/PVA nanocomposite films were structurally characterized by X-ray diffraction technique, from which the presence of both PVA and ZnO in the nanocomposite was established. The optical absorptive nonlinearity in the nanocomposite films was investigated using open aperture Z-scan technique. The results indicate optical limiting type nonlinearity in the films due to two photon absorption in ZnO with efficiency more than 50%. These films also show a self defocusing type negative nonlinear refraction in closed aperture Z-scan experiment. The present studies indicate that, highly transparent and homogeneous films of ZnO/PVA nanocomposite can be obtained on glass substrates using simple methods, in a highly cost effective way, since PVA is water soluble. These nanocomposite films offer prospects of application as efficient optical limiters to protect light sensitive devices from the possible damage on exposure to high intensity radiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigations on the electrical, thermal and optical properties of the nonlinear optical allylthiourea mercury chloride single crystals

Graphical abstract: Display Omitted Highlights: ► The single crystals of dimension 10 × 5 × 5 mm{sup 3} of allylthiourea mercury chloride are synthesized using slow evaporation technique. ► The bandgap of allylthiourea mercury chloride crystal is found to be about 3.18 eV. ► The optical nonlinearity of the crystal sample are studied using the open aperture Z-scan technique employing a nanosecond laser at 532 nm, and three photon absorption effect has been found. ► An improved photo pyroelectric is used to find the thermal parameters of the crystal. ► The piezoelectric charge coefficient is determined. -- Abstract: Single crystals of dimension 10 × 5 × 5 mm{sup 3} of allylthiourea mercury chloride were synthesized from aqueous solution using slow evaporation technique at ambient temperature. The grown crystals are confirmed by elemental analysis. The band gap of Allylthiourea mercury chloride crystal was found to be about 3.18 eV. The optical nonlinearity of the crystal sample was studied using the open aperture Z-scan technique employing a nanosecond laser at 532 nm, and a three-photon absorption effect has been found. The electrical properties such as dielectric constant, dielectric loss and ac conductivity of the sample were carried out by Agillent E 4980 A LCR meter at different temperatures. An improved photopyroelectric technique was used to find the thermal parameters of the crystal. The piezo electric charge coefficient is also determined.

36 MATERIALS SCIENCE↗

Solvothermal synthesis and study of nonlinear optical properties of nanocrystalline thallium doped bismuth telluride

Nanocrystalline Bismuth telluride and thallium (4 mol %) doped Bismuth telluride were synthesized through hydrothermal method. The as-prepared products were characterized using Powder X-ray Diffraction, High Resolution Transmission Electron Microscopy, Energy Dispersive X-Ray Spectroscopy, UV-Visible spectroscopy and Fourier Transform Infrared Spectroscopy. Powder XRD results revealed the crystalline nature of the obtained phases. HRTEM showed the particle-like morphology of the products. The decrease in the absorption coefficient due to thallium doping was observed in FTIR spectra. The intensity dependent nonlinear optical properties of nanocrystalline bismuth telluride and thallium doped bismuth telluride were studied using the Z-scan technique in open-aperture configuration. Bismuth telluride doped with thallium showed enhanced nonlinear optical response compared to pristine bismuth telluride and hence could be used as a potential candidate for optical power limiting applications. - Graphical Abstract: Nonlinear transmission (Z-scan) curves of nanocrystalline bismuth telluride ({Delta}) and thallium doped bismuth telluride ({open_square}). Thallium doped bismuth telluride showed enhanced nonlinear absorption compared to bismuth telluride. Inset: TEM micrograph of bismuth telluride nanocrystallites. Highlights: Black-Right-Pointing-Pointer Synthesis of Nanocrystalline Bi{sub 2}Te{sub 3} and Thallium doped Bi{sub 2}Te{sub 3} through solvothermal method. Black-Right-Pointing-Pointer Reduced absorption coefficient due to thallium doping found from IR spectroscopy. Black-Right-Pointing-Pointer Open-aperture Z-scan technique for nonlinear optical studies. Black-Right-Pointing-Pointer Two photon absorption based model for theoretical fitting of Z-scan data. Black-Right-Pointing-Pointer Enhanced nonlinear absorption in Thallium doped Bi{sub 2}Te{sub 3} - potential candidate for optical power limiting applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of the compact proton beam therapy system dedicated to spot scanning with real-time tumor-tracking technology

Hokkaido University and Hitachi Ltd. have started joint development of the Gated Spot Scanning Proton Therapy with Real-Time Tumor-Tracking System by integrating real-time tumor tracking technology (RTRT) and the proton therapy system dedicated to discrete spot scanning techniques under the {sup F}unding Program for World-Leading Innovative R and D on Science and Technology (FIRST Program){sup .} In this development, we have designed the synchrotron-based accelerator system by using the advantages of the spot scanning technique in order to realize a more compact and lower cost proton therapy system than the conventional system. In the gated irradiation, we have focused on the issues to maximize irradiation efficiency and minimize the dose errors caused by organ motion. In order to understand the interplay effect between scanning beam delivery and target motion, we conducted a simulation study. The newly designed system consists of the synchrotron, beam transport system, one compact rotating gantry treatment room with robotic couch, and one experimental room for future research. To improve the irradiation efficiency, the new control function which enables multiple gated irradiations per synchrotron cycle has been applied and its efficacy was confirmed by the irradiation time estimation. As for the interplay effect, we confirmed that the selection of a strict gating width and scan direction enables formation of the uniform dose distribution.

43 PARTICLE ACCELERATORS↗

In situ plasmonic tip preparation and validation techniques for scanning tunneling microscopy

Among the many parts constituting a scanning tunneling microscope, the metallic tip is the component that directly interacts with the specimen and plays a critical role in visualizing the physical quantity of interest. While tip materials such as W and Pt–Ir are commonly used for topographic imaging and their preparation is well-documented, the preparation of plasmonic materials such as Ag for tip-enhanced Raman spectroscopy is relatively less standardized. Furthermore, we present several in situ Ag tip preparation and validation techniques for the microscopist to use depending on their intended application, including atomic resolution imaging, scanning tunneling spectroscopy (STM), and tip-enhanced Raman spectro-microscopy in ultrahigh vacuum. Besides optical applications, these methods are not limited to Ag but also applicable to other STM tip materials.

47 OTHER INSTRUMENTATION↗

High resolution dual detector volume-of-interest cone beam breast CT - Demonstration with a bench top system

Purpose: In this study, we used a small field high resolution detector in conjunction with a full field flat panel detector to implement and investigate the dual detector volume-of-interest (VOI) cone beam breast computed tomography (CBCT) technique on a bench-top system. The potential of using this technique to image small calcifications without increasing the overall dose to the breast was demonstrated. Significant reduction of scatter components in the high resolution projection image data of the VOI was also shown. Methods: With the regular flat panel based CBCT technique, exposures were made at 80 kVp to generate an air kerma of 6 mGys at the isocenter. With the dual detector VOI CBCT technique, a high resolution small field CMOS detector was used to scan a cylindrical VOI (2.5 cm in diameter and height, 4.5 cm off-center) with collimated x-rays at four times of regular exposure level. A flat panel detector was used for full field scan with low x-ray exposures at half of the regular exposure level. The low exposure full field image data were used to fill in the truncated space in the VOI scan data and generate a complete projection image set. The Feldkamp-Davis-Kress (FDK) filtered backprojection algorithm was used to reconstruct high resolution images for the VOI. Two scanning techniques, one breast centered and the other VOI centered, were implemented and investigated. Paraffin cylinders with embedded thin aluminum (Al) wires were imaged and used in conjunction with optically stimulated luminescence (OSL) dose measurements to demonstrate the ability of this technique to image small calcifications without increasing the mean glandular dose (MGD). Results: Using exposures that produce an air kerma of 6 mGys at the isocenter, the regular CBCT technique was able to resolve the cross-sections of Al wires as thin as 254 {mu}m in diameter in the phantom. For the specific VOI studied, by increasing the exposure level by a factor of 4 for the VOI scan and reducing the exposure level by a factor of 2 for the full filed scan, the dual-detector CBCT technique was able to resolve the cross-sections of Al wires as thin as 152 {mu}m in diameter. The CNR evaluated for the entire Al wire cross-section was found to be improved from 5.5 in regular CBCT to 14.4 and 16.8 with the breast centered and VOI centered scanning techniques, respectively. Even inside VOI center, the VOI scan resulted in significant dose saving with the dose reduced by a factor of 1.6 at the VOI center. Dose saving outside the VOI was substantial with the dose reduced by a factor of 7.3 and 7.8 at the breast center for the breast centered and VOI centered scans, respectively, when compared to full field scan at the same exposure level. The differences between the two dual detector techniques in terms of dose saving and scatter reduction were small with VOI scan at 4x exposure level and full field scan at 0.5x exposure level. The MGDs were only 94% of that from the regular CBCT scan. Conclusions: For the specific VOI studied, the dual detector VOI CBCT technique has the potential to provide high quality images inside the VOI with MGD similar to or even lower than that of full field breast CBCT. It was also found that our results were compromised by the use of inadequate detectors for the VOI scan. An appropriately selected detector would better optimize the image quality improvement that can be achieved with the VOI CBCT technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Transverse Crack Detection in Composites

A modified ultrasonic C-scan technique was implemented for improving the detection of a certain type of damage in composite specimens. The type of damage being studied is transverse (through the thickness) cracking of unidirectional off-axis graphite-epoxy specimens. These cracks are difficult to detect using standard through-transmission C-scan techniques. The modification is based on mode conversion to produce transmitted shear waves from incident longitudinal waves. While mode conversion is used extensively with isotropic materials, its use with composites is more limited. This is largely because the computation of wave propagation parameters is significantly more complicated with highly anisotropic materials than with isotropic materials. The appropriate incident angles to produce the desired mode conversion were computed based on the mechanical properties of the composite. Once the angles were computed the technique was simple to implement and resulted in marked improvement in detection of the transverse cracks being studied.

Pereira, J. Michael↗

Two-Dimensional Measurement of n+-p Asymmetrical Junctions in Multicrystalline Silicon Solar Cells Using AFM-Based Electrical Techniques with Nanometer Resolution: Preprint

Lateral inhomogeneities of modern solar cells demand direct electrical imaging with nanometer resolution. We show that atomic force microscopy (AFM)-based electrical techniques provide unique junction characterizations, giving a two-dimensional determination of junction locations. Two AFM-based techniques, scanning capacitance microscopy/spectroscopy (SCM/SCS) and scanning Kelvin probe forcemicroscopy (SKPFM), were significantly improved and applied to the junction characterizations of multicrystalline silicon (mc-Si) cells. The SCS spectra were taken pixel by pixel by precisely controlling the tip positions in the junction area. The spectra reveal distinctive features that depend closely on the position relative to the electrical junction, which allows us to indentify theelectrical junction location. In addition, SKPFM directly probes the built-in potential over the junction area modified by the surface band bending, which allows us to deduce the metallurgical junction location by identifying a peak of the electric field. Our results demonstrate resolutions of 10-40 nm, depending on the techniques (SCS or SKPFM). These direct electrical measurements withnanometer resolution and intrinsic two-dimensional capability are well suited for investigating the junction distribution of solar cells with lateral inhomogeneities.

14 SOLAR ENERGY↗

Preparation and characterization of RF magnetron sputtered CuO/CaTi{sub 4}O{sub 9} thin films with enhanced third-order nonlinear optical properties

The titanate, is a material of interest for various energy applications, including photovoltaics, catalysts, and high-rate energy storage devices. Herein, its related materials, CuO/CaTi{sub 4}O{sub 9} [CCTO] thin films, were successfully fabricated on SrTiO{sub 3} (100) substrates by RF magnetron sputtering assisted with subsequent oxygen annealing. This obtained CCTO thin films were then systemically studied by X-ray powder diffraction (XRD), atomic force microscopy (AFM), scan electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and high-resolution transmission electron microscopy (HRTEM). It was found that CuO and CaTi{sub 4}O{sub 9} (001) particles were closely accumulated together on the surface of the substrate in the annealing process after comparing with that of the as-prepared thin film, which was verified by SEM and AFM results. Furthermore, we investigated the third-order nonlinear optical (NLO) properties of the as-prepared and annealed CCTO thin film by means of the Z-scan technique using 650 nm femtosecond laser pulse. Post-deposition oxygen annealing was found to modify the morphological characteristics of the films, resulting in enhancing their NLO properties. The observation of NLO performance of annealed CCTO thin film indicates that RF magnetron sputtering is a feasible method for the fabrication of optical thin films, which can be expanded to fabricate other NLO materials from the corresponding dispersions. Naturally, we concluded that the CCTO thin film occupy a better NLO property, and thus enlarge its application in nonlinear optics. - Highlights: • The CCTO thin film was prepared using the RF magnetron sputtering and oxygen annealing. • The film was prepared on the SrTiO{sub 3}(100) substrates with a Ca{sub 2}CuO{sub 3} target. • The oxygen annealing was found can effectively enhance the film quality and NLO property. • The film was characterized using XPS, SEM, AFM, TEM, XRD and Z-scan techniques.

36 MATERIALS SCIENCE↗

Chemical Imaging of Ambient Aerosol Particles: Observational Constraints on Mixing State Parameterization

A new parameterization for quantifying the mixing state of aerosol populations has been applied for the first time to samples of ambient particles analyzed using spectro-microscopy techniques. Scanning transmission x-ray microscopy/near edge x-ray absorption fine structure (STXM/NEXAFS) and computer controlled scanning electron microscopy/energy dispersive x-ray spectroscopy (CCSEM/EDX) were used to probe the composition of the organic and inorganic fraction of individual particles collected on June 27th and 28th during the 2010 Carbonaceous Aerosols and Radiative Effects (CARES) study in the Central Valley, California. The first field site, T0, was located in downtown Sacramento, while T1 was located near the Sierra Nevada Mountains. Mass estimates of the aerosol particle components were used to calculate mixing state metrics, such as the particle-specific diversity, bulk population diversity, and mixing state index, for each sample. Both microscopy imaging techniques showed more changes over these two days in the mixing state at the T0 site than at the T1 site. The STXM data showed evidence of changes in the mixing state associated with a build-up of organic matter confirmed by collocated measurements and the largest impact on the mixing state was due to an increase in soot dominant particles during this build-up. The CCSEM/EDX analysis showed the presence of two types of particle populations; the first was dominated by aged sea salt particles and had a higher mixing state index (indicating a more homogeneous population), the second was dominated by carbonaceous particles and had a lower mixing state index.

Environmental Molecular Sciences Laboratory↗

Preparation and nonlinear optical properties of indium nanocrystals in sodium borosilicate glass by the sol–gel route

Graphical abstract: The sodium borosilicate glass doped with indium nanocrystals have been successfully prepared by sol–gel methods. And the indium nanocrystals in tetragonal crystal system have formed uniformly in the glass, and the average diameter of indium nanocrystals is about 30 nm. The third-order optical nonlinear refractive index γ, absorption coefficient β, and susceptibility χ{sup (3)} of the glass are determined to be −4.77 × 10{sup −16} m{sup 2}/W, 2.67 × 10{sup −9} m/W, and 2.81 × 10{sup −10} esu, respectively. Highlights: ► Indium nanocrystals embedded in glass matrix have been prepared by sol–gel route. ► The crystal structure and composition are investigated by XRD and XPS. ► Size and distribution of indium nanocrystals is determined by TEM. ► The third-order optical nonlinearity is investigated by using Z-scan technique. -- Abstract: The sodium borosilicate glass doped with indium nanocrystals have been successfully prepared by sol–gel route. The thermal stability behavior of the stiff gel is investigated by thermogravimetric (TG) and differential thermal (DTA) analysis. The crystal structure of the glass is characterized by X-ray powder diffraction (XRD). Particle composition is determined by X-ray photoelectron spectroscopy (XPS). Size and distribution of the nanocrystals are characterized by transmission electron microscopy (TEM) as well as high-resolution transmission electron microscopy (HRTEM). Results show that the indium nanocrystals in tetragonal crystal structure have formed in glass, and the average diameter is about 30 nm. Further, the glass is measured by Z-scan technique to investigate the nonlinear optical (NLO) properties. The third-order NLO coefficient χ{sup (3)} of the glass is determined to be 2.81 × 10{sup −10} esu. The glass with large third-order NLO coefficient is promising materials for applications in optical devices.

36 MATERIALS SCIENCE↗

Compositional dependence of the nonlinear refractive index of new germanium-based chalcogenide glasses

In this paper, we report results of n{sub 2} measurements of new chalcogenide glasses in the Ge-Sb-S-Se system using a modified Z-Scan technique. Measurements were made with picosecond pulses emitted by a 10 Hz Q-switched mode-locked Nd-YAG laser at 1064 nm under conditions suitable to characterize ultrafast nonlinearities. The nonlinear index increases up to 500 times the n{sub 2} of fused silica with an increase in the Ge/Se ratio and a decrease with an increase of the Ge/Sb ratio. We confirmed, using Raman spectroscopy, that the nonlinear refractive index depends on the number of Ge-S(Se) and Sb-S(Se) bonds in the glass network. Sulfide glasses were shown to have a nonlinear FOM near or <1, at 1064 nm. - Graphical abstract: In this paper, we report results of n{sub 2} measurements of new chalcogenide glasses in the Ge-Sb-S-Se system using a modified Z-Scan technique. n{sub 2} is found to increase with an increase of normalized photon energy, regardless of chalcogen type, but does not depend on the concentration of lone pair electron.

36 MATERIALS SCIENCE↗

Precursor and Neutral Loss Scans in an RF Scanning Linear Quadrupole Ion Trap

Methodology for performing precursor and neutral loss scans in an RF scanning linear quadrupole ion trap is described and compared to the unconventional ac frequency scan technique. In the RF scanning variant, precursor ions are mass selectively excited by a fixed frequency resonance excitation signal at low Mathieu q while the RF amplitude is ramped linearly to pass ions through the point of excitation such that the excited ion’s m/z varies linearly with time. Ironically, a nonlinear ac frequency scan is still required for ejection of the product ions since their frequencies vary nonlinearly with the linearly varying RF amplitude. In the case of the precursor scan, the ejection frequency must be scanned so that it is fixed on a product ion m/z throughout the RF scan, whereas in the neutral loss scan, it must be scanned to maintain a constant mass offset from the excited precursor ions. Both simultaneous and sequential permutation scans are possible; only the former are demonstrated here. The scans described are performed on a variety of samples using different ionization sources: protonated amphetamine ions generated by nanoelectrospray ionization (nESI), explosives ionized by low-temperature plasma (LTP), and chemical warfare agent simulants sampled from a surface and analyzed with swab touch spray (TS). We lastly conclude that the ac frequency scan variant of these MS/MS scans is preferred due to electronic simplicity. In an accompanying manuscript, we thus describe the implementation of orthogonal double resonance precursor and neutral loss scans on the Mini 12 using constant RF voltage. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗