Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scheduling Service”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SmartTransit.AI: A Dynamic Paratransit and Microtransit Application

New rideshare and shared mobility services have transformed urban mobility in recent years. Such services have the potential to improve efficiency and reduce costs by allowing users to share rides in high-capacity vehicles and vans. Most transit agencies already operate various ridepooling services, including microtransit and paratransit. However, the objectives and constraints for implementing these services vary greatly between agencies and can be challenging. First, off-the-shelf ridepooling formulations must be adapted for real-world conditions and constraints. Second, the lack of modular and reusable software makes it hard to implement and evaluate new ridepooling algorithms and approaches in real-world settings. We demonstrate a modular on-demand public transportation scheduling software for microtransit and paratransit services. The software is aimed at transit agencies looking to incorporate state-of-the-art rideshare and ridepooling algorithms in their everyday operations. We provide management software for dispatchers and mobile applications for drivers and users and conclude with results from the demonstration in Chattanooga, TN.

Pavia, Sophie↗

Advance Resource Provisioning in Bulk Data Scheduling

Today?s scientific and business applications generate mas- sive data sets that need to be transferred to remote sites for sharing, processing, and long term storage. Because of increasing data volumes and enhancement in current net- work technology that provide on-demand high-speed data access between collaborating institutions, data handling and scheduling problems have reached a new scale. In this paper, we present a new data scheduling model with ad- vance resource provisioning, in which data movement operations are defined with earliest start and latest comple- tion times. We analyze time-dependent resource assign- ment problem, and propose a new methodology to improve the current systems by allowing researchers and higher-level meta-schedulers to use data-placement as-a-service, so they can plan ahead and submit transfer requests in advance. In general, scheduling with time and resource conflicts is NP-hard. We introduce an efficient algorithm to organize multiple requests on the fly, while satisfying users? time and resource constraints. We successfully tested our algorithm in a simple benchmark simulator that we have developed, and demonstrated its performance with initial test results.

97 MATHEMATICS AND COMPUTING↗

On-Demand Transit: Features, Benefits, Challenges, Costs, and Evaluation

The U.S. Department of Energy's National Laboratory of the Rockies works in partnership with communities and transit agencies across North America to support and evaluate customized on-demand transit (ODT) systems. ODT, also known as on-demand mobility or microtransit, is a flexible form of public mobility. Unlike traditional fixed-route transit, ODT adjusts where and when service is provided rather than following predetermined schedules and routes. Having evolved from commercial ride-hailing business models, ODT leverages smartphone connectivity and real-time route optimization to provide highly responsive and dynamic service. ODT trips, which are usually shared, can function as a standalone service or as a first-/last-mile service connecting riders to other types of transit.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding the evolution of conditions data access through Frontier for the ATLAS Experiment

The ATLAS Distributed Computing system uses the Frontier system to access the Conditions, Trigger, and Geometry database data stored in the Oracle Offline Database at CERN by means of the HTTP protocol. All ATLAS computing sites use Squid web proxies to cache the data, greatly reducing the load on the Frontier servers and the databases. One feature of the Frontier client is that in the event of failure, it retries with different services. While this allows transient errors and scheduled maintenance to happen transparently, it does open the system up to cascading failures if the load is high enough. Throughout LHC Run 2 there has been an ever increasing demand on the Frontier service. There have been multiple incidents where parts of the service failed due to high load. A significant improvement in the monitoring of the Frontier service was required. The monitoring was needed to identify both problematic tasks, which could then be killed or throttled, and to identify failing site services as the consequence of a cascading failure is much higher. This presentation describes the implementation and features of the monitoring system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EVALUATING THE COMPETITIVENESS OF ENERGY STORAGE FOR MITIGATING THE STOCHASTIC, VARIABLE ATTRIBUTES OF RENEWABLES ON THE GRID

Energy storage has recently attracted significant interest as an enabling technology for integrating stochastic, variable renewable power into the electric grid. To meet the renewable portfolio standards targets imposed by 29 U.S. states and the District of Columbia, electricity production from wind technology has increased significantly. At the same time, wind turbines, like many renewables, produce power in a manner that is stochastic, variable, and non-dispatchable. These attributes introduce challenges to generation scheduling and the provision of ancillary services. To study the impacts of the stochastic variability of wind on regional grid operation and the role that energy storage could play to mitigate these impacts, Pacific Northwest National Laboratory (PNNL) has developed a series of linked, complex techno-economic-environmental models to address these key questions: a. What are the future expanded balancing requirements necessary to accommodate enhanced wind turbine capacity, so as to meet the renewable portfolio standards in 2020? Specific analyses are conducted for the four North American Electric Reliability Corporation (NERC) western sub-regions. b. What are the most cost-effective technological solutions for providing either fast ramping generation or energy storage to serve these balancing requirements? PNNL applied a stochastic approach to assess the future, expanded balancing requirements for the four western sub-regions with high wind penetration in 2020. The estimated balancing requirements are quantified for four sub-regions: Arizona-New Mexico-Nevada (AZNMNV), California-Mexico (CAMC), Northwest Power Pool (NWPP), and Rocky Mountain Power Pool (RMPP). Model results indicate that the new balancing requirements will span a spectrum of frequencies, from minute-to-minute variability (intra-hour balancing) to those indicating cycles over several hours (inter-hour balancing). The sharp ramp rates in the intra-hour balancing are of significant concern to grid operators. Consequently, this study focuses on analyzing the intra-hour balancing needs. A detailed, life-cycle cost (LCC) modeling effort was used to assess the cost competitiveness of different technologies to address the future, intra-hour balancing requirements. Technological solutions considered include combustion turbines, sodium sulfur (NaS) batteries, lithium ion (Li-ion) batteries, pumped-hydro energy storage (PHES), compressed air energy storage (CAES), flywheels, redox flow batteries, and demand response (DR). Hybrid concepts are also evaluated. For each technology, distinct power and energy capacity requirements are estimated. LCC results indicate that the most cost competitive technologies include electrochemical energy storage and Na-S and Li-Ion. This finding is consistent among the four sub-regions and is generally applicable to other regions.

arbitrage↗

Scaling Optimal Allocation of Cloud Resources Using Lagrange Relaxation

The rapid growth of Cloud Computing (CC) has increased the variety of computing resources, storage, and communication services that pose significant new challenges for the efficient use of cloud resources. The cost-efficient allocation of cloud resources has become a decisive premise for the adoption of CC services. The cost-efficient selection and scheduling of these resources to meet the demands of a scientific workflow is a challenging problem that is exacerbated by the inclusion of multiple CC providers. In this paper, we present a novel strategy for the cost-efficient selection of CC resources using Lagrange relaxation. Our approach is based on preselection of resources and demand decomposition to create a series of smaller sub-problems, which allow the estimation of the best cost-structures and selection of CC service providers for a subset of the time period of the planning horizon. Decomposition of the demand is achieved through the boundary analysis of a continuous relaxation of the problem. Using the metrics defined in terms of the cost and time of completion, we demonstrate excellent performance in relation to optimal solutions. Our method reduced the computational time from hours to seconds for a representative 36-month problem and provided high-quality solutions (< 0.05% relative error). Given the importance of selecting resources and scheduling complex scientific workflows, we believe that this novel strategy will be beneficial for many researchers and users of cloud computing resources.

De La Torre, Luis↗

BigData Express: Toward Predictable, Schedulable, and High-Performance Data Transfer [PowerPoint]

Topics include: • BigData Express: a schedulable, predictable, and high-performance data transfer service – A peer-to-peer, scalable, and extensible data transfer model – A visually appealing, easy-to-use web portal – A high-performance data transfer engine – A time-constraint-based scheduler – On-demand provisioning of end-to-end network paths with guaranteed QoS – Robust and flexible error handling – CILogon-based security

97 MATHEMATICS AND COMPUTING↗

Method and system for providing flexible reserve power for power grid

An optimization-based method and system is disclosed to enable heterogeneous loads and distributed energy resources (DERs) to participate in grid ancillary services, such as spinning and non-spinning reserves, and ramping reserves. The method includes receiving inputs for decision parameters for optimizing an objective for obtaining flexible reserve power, solving the objective for obtaining flexible reserve power, determining a reserve power schedule for a prediction horizon for providing flexible reserve power based on the objective, generating a service bid based on the reserve power schedule for the power grid; and when the service bid is accepted, providing flexible reserve power to the power grid based on the service bid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Use of Frequency Response Metrics to Assess the Planning and Operating Requirements for Reliable Integration of Variable Renewable Generation

An interconnected electric power system is a complex system that must be operated within a safe frequency range in order to reliably maintain the instantaneous balance between generation and load. This is accomplished by ensuring that adequate resources are available to respond to expected and unexpected imbalances and restoring frequency to its scheduled value in order to ensure uninterrupted electric service to customers. Electrical systems must be flexible enough to reliably operate under a variety of"change" scenarios. System planners and operators must understand how other parts of the system change in response to the initial change, and need tools to manage such changes to ensure reliable operation within the scheduled frequency range. This report presents a systematic approach to identifying metrics that are useful for operating and planning a reliable system with increased amounts of variable renewable generation which builds on existing industry practices for frequency control after unexpected loss of a large amount of generation. The report introduces a set of metrics or tools for measuring the adequacy of frequency response within an interconnection. Based on the concept of the frequency nadir, these metrics take advantage of new information gathering and processing capabilities that system operators are developing for wide-area situational awareness. Primary frequency response is the leading metric that will be used by this report to assess the adequacy of primary frequency control reserves necessary to ensure reliable operation. It measures what is needed to arrest frequency decline (i.e., to establish frequency nadir) at a frequency higher than the highest set point for under-frequency load shedding within an interconnection. These metrics can be used to guide the reliable operation of an interconnection under changing circumstances.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Deep Reinforcement Learning From Demonstrations to Assist Service Restoration in Islanded Microgrids

Microgrids can be operated in island mode during utility grid outages to support service restoration and improve system resilience. To schedule and dispatch distributed energy resources (DERs) in an islanded microgrid, conventional model-based methods rely on accurate distribution network models and lack generalization and adaptability. Data-driven methods are promising for DER coordination but face practical challenges such as potential hazards to microgrids during online training and insufficient online training opportunities due to low outage rates. This paper presents a novel two-stage learning framework that builds on the deep deterministic policy gradient from demonstrations to identify an optimal restoration strategy. At the pre-training stage, imitation learning is applied to equip the control agent with expert experiences to guarantee acceptable initial performance. At the online training stage, action clipping, reward shaping, and expert demonstrations are leveraged to ensure safe exploration while accelerating the training process. In conclusion, the proposed method is illustrated using the IEEE 123-node system and compared with a representative model-based method and the standard deep deterministic policy gradient method to prove solution accuracy and demonstrate increased computational efficiency.

Du, Yan↗

Energy Storage for Power Systems Applications: A Regional Assessment for the Northwest Power Pool (NWPP)

Wind production, which has expanded rapidly in recent years, could be an important element in the future efficient management of the electric power system; however, wind energy generation is uncontrollable and intermittent in nature. Thus, while wind power represents a significant opportunity to the Bonneville Power Administration (BPA), integrating high levels of wind resources into the power system will bring great challenges to generation scheduling and in the provision of ancillary services. This report addresses several key questions in the broader discussion on the integration of renewable energy resources in the Pacific Northwest power grid. More specifically, it addresses the following questions: a) how much total reserve or balancing requirements are necessary to accommodate the simulated expansion of intermittent renewable energy resources during the 2019 time horizon, and b) what are the most cost effective technological solutions for meeting load balancing requirements in the Northwest Power Pool (NWPP).

17 WIND ENERGY↗

Fairchilde Puppet Environment

The software creates a minimal directory organization structure and data isolation methods so that groups and projects are differentiated and isolated by levels in the hierarchy naming schemes. It also allows various versions of Puppet server and client to be used by different groups and projects so that groups can maintain their own upgrade and patching schedules without introducing breaking changes and unnecessary service outages to other groups using the framework.

Campfield, Michael P↗

Alternative cooling resource for removing the residual heat of reactor

The Recirculated Cooling Water (RCW) system of a Candu reactor is a closed cooling system which delivers demineralized water to coolers and components in the Service Building, the Reactor Building, and the Turbine Building and the recirculated cooling water is designed to be cooled by the Raw Service Water (RSW). During the period of scheduled outage, the RCW system provides cooling water to the heat exchangers of the Shutdown Cooling System (SDCS) in order to remove the residual heat of the reactor, so the RCW heat exchangers have to operate at all times. This makes it very hard to replace the inlet and outlet valves of the RCW heat exchangers because the replacement work requires the isolation of the RCW. A task force was formed to prepare a plan to substitute the recirculated water with the chilled water system in order to cool the SDCS heat exchangers. A verification test conducted in 2007 proved that alternative cooling was possible for the removal of the residual heat of the reactor and in 2008 the replacement of inlet and outlet valves of the RCW heat exchangers for both Wolsong unit 3 and 4 were successfully completed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Safer Transportation and Disposal of Remote Handled Transuranic Waste - 12033

Since disposal of remote handled (RH) transuranic (TRU) waste at the Waste Isolation Pilot Plant (WIPP) began in 2007, the Department of Energy (DOE) has had difficulty meeting the plans and schedule for disposing this waste. PECOS Management Services, Inc. (PECOS) assessed the feasibility of proposed alternate RH-TRU mixed waste containerisation concepts that would enhance the transportation rate of RH-TRU waste to WIPP and increase the utilization of available WIPP space capacity for RH-TRU waste disposal by either replacing or augmenting current and proposed disposal methods. In addition engineering and operational analyses were conducted that addressed concerns regarding criticality, heat release, and worker exposure to radiation. The results of the analyses showed that the concept, development, and use of a concrete pipe based design for an RH-TRU waste shipping and disposal container could be potentially advantageous for disposing a substantial quantity of RHTRU waste at WIPP in the same manner as contact-handled RH waste. Additionally, this new disposal method would eliminate the hazard associated with repackaging this waste in other containers without the requirement for NRC approval for a new shipping container. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of A Hardware-In-the-Loop (HIL) Testbed for Cyber-Physical Security in Smart Buildings

As smart buildings move towards open communication technologies, providing access to the Building Automation System (BAS) through the building's intranet, or even remotely through the Internet, has become a common practice. However, BAS was historically developed as a closed environment and designed with limited cyber-security considerations. Thus, smart buildings are vulnerable to cyber-attacks with the increased accessibility. This study introduces the development and capability of a Hardware-in-the-Loop (HIT) testbed for testing and evaluating the cyber-physical security of typical BASs in smart buildings. The testbed consists of three subsystems: (1) a real-time HIL emulator simulating the behavior of a virtual building as well as the Heating, Ventilation, and Air Conditioning (HVAC) equipment via a dynamic simulation in Modelica; (2) a set of real HVAC controllers monitoring the virtual building operation and providing local control signals to control HVAC equipment in the HIL emulator; and (3) a BAS server along with a web-based service for users to fully access the schedule, setpoints, trends, alarms, and other control functions of the HVAC controllers remotely through the BACnet network. The server generates rule-based setpoints to local HVAC controllers. Based on these three subsystems, the HIL testbed supports attack/fault-free and attack/fault-injection experiments at various levels of the building system. The resulting test data can be used to inform the building community and support the cyber-physical security technology transfer to the building industry.

Li, Guowen↗

Analysis and design of DC-link capacitor in cascaded H-bridge multilevel active front-end converter

Medium-voltage grid-tied systems often use a cascaded H-bridge multi-level active front-end. In this converter, dc link bus capacitors play an important role in stabilizing the converter and enabling both active and reactive power injections. The present work provides analytical expressions for the capacitor current, which are essential for optimizing system design (especially capacitor size vs. lifetime). Then, the expression is incorporated into the grid connected bidirectional power system model. Consequently, this work contributes to the guiding principles to choose accurate dc link capacitor ratings against grid-side power delivery requirements. DC-link capacitors come with an expiration date which is dependent on the operating power and voltage values. Lack of information about the lifetime of the dc-link capacitor creates uncertainty in the duration of online operation of the converter, thus increasing the probability of a contingency outage. The lifetime of the capacitor can range from only a few seconds of online operation of the station due to under-sizing, to a compromised quality of power flowing through other solid state devices which may not have been designed for the transients that are caused by over-sizing of the dc-link capacitor. A better estimate of the lifetime of these capacitors can help maximize usage and maintain scheduled outages more efficiently, without disruption in service.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Federated Architecture for Secure and Transactive Distributed Energy Resource Management Solutions (FAST-DERMS)

This document provides system-level specifications for a federated architecture for secure and transactive distributed energy resource management solutions (FAST-DERMS), presents a solution, and describes operational concepts for the proposed solution. FAST-DERMS enables the provision of reliable, resilient, and secure transmission and distribution (T&D) grid services through the scalable aggregation and near-real-time management of utility-scale and small-scale distributed energy resources (DERs). We first present the principles and objectives of FAST-DERMS. Then, after discussing important system concepts, we present the specifications for FAST-DERMS and a solution that employs a distributed and federated control methodology in which the DERs connected to a single point of common coupling with the rest of the system, such as individual substations, are optimized coordinately to provide system-level grid services. FAST-DERMS aims to aggregate and coordinate the operations of DERs to support T&D grid operations. The key optimization and control component of this FAST-DERMS reference implementation is a flexible resource scheduler (FRS) that aggregates the DERs within a substation service area. These FRSs operate at the substation level and perform constrained economic dispatch of DERs, either directly or through a transactive market or aggregator, as shown in Figure ES-1. An FRS Coordinator at the distribution system operator (DSO) level aggregates distribution substations operated by FRSs and interfaces with the transmission system operator (TSO) to provide transmission services. FAST-DERMS also allows for the integration of the FRS Coordinator with an existing distribution utility management system that could be employed by the DSO to enhance distribution grid operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Energy Resource Optimization Using a Software as Service (SaaS) Approach at the University of California, Davis Campus

Together with OSIsoft LLC as its private sector partner and matching sponsor, the Lawrence Berkeley National Laboratory (Berkeley Lab) won an FY09 Technology Commercialization Fund (TCF) grant from the U.S. Department of Energy. The goal of the project is to commercialize Berkeley Lab's optimizing program, the Distributed Energy Resources Customer Adoption Model (DER-CAM) using a software as a service (SaaS) model with OSIsoft as its first non-scientific user. OSIsoft could in turn provide optimization capability to its software clients. In this way, energy efficiency and/or carbon minimizing strategies could be made readily available to commercial and industrial facilities. Specialized versions of DER-CAM dedicated to solving OSIsoft's customer problems have been set up on a server at Berkeley Lab. The objective of DER-CAM is to minimize the cost of technology adoption and operation or carbon emissions, or combinations thereof. DER-CAM determines which technologies should be installed and operated based on specific site load, price information, and performance data for available equipment options. An established user of OSIsoft's PI software suite, the University of California, Davis (UCD), was selected as a demonstration site for this project. UCD's participation in the project is driven by its motivation to reduce its carbon emissions. The campus currently buys electricity economically through the Western Area Power Administration (WAPA). The campus does not therefore face compelling cost incentives to improve the efficiency of its operations, but is nonetheless motivated to lower the carbon footprint of its buildings. Berkeley Lab attempted to demonstrate a scenario wherein UCD is forced to purchase electricity on a standard time-of-use tariff from Pacific Gas and Electric (PG&E), which is a concern to Facilities staff. Additionally, DER-CAM has been set up to consider the variability of carbon emissions throughout the day and seasons. Two distinct analyses of value to UCD are possible using this approach. First, optimal investment choices for buildings under the two alternative objectives can be derived. Second, a week-ahead building operations forecaster has been written that executes DER-CAM to find an optimal operating schedule for buildings given their expected building energy services requirements, electricity prices, and local weather. As part of its matching contribution, OSIsoft provided a full implementation of PI and a server to install it on at Berkeley Lab. Using the PItoPI protocol, this gives Berkeley Lab researchers direct access to UCD's PI data base. However, this arrangement is in itself inadequate for performing optimizations. Additional data not included in UCD's PI database would be needed and the campus was not able to provide this information. This report details the process, results, and lessons learned of this commercialization project.

25 ENERGY STORAGE↗