Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scintillation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Shaped scintillation detector systems for measurements of gamma ray flux anisotropy

The detection efficiencies of cylindrical detectors for various gamma ray photon angular distributions were studied in the energy range from .10 Mev to 15 Mev. These studies indicate that simple detector systems on small satellites can be used to measure flux anisotropy of cosmic gamma rays and the angular distribution of albedo gamma rays produced in planetary atmospheres. The results indicate that flat cylindrical detectors are most suitable for measuring flux anisotropy because of their angular response function. A general method for calculating detection efficiencies for such detectors is presented.

Trombka, J. I.↗

Scintillation light calibrations, systematic uncertainties, and triggering efficiency in the MicroBooNE detector

Scintillation light, produced alongside ionisation charge from particle interactions, plays a critical role in liquid argon time projection chamber (LArTPC) detectors. A detailed understanding of its production and detection mechanisms is essential for robust calibration, systematic uncertainty evaluation, and physics analysis. This article describes the MicroBooNE light simulation, light-based triggering schemes, photomultiplier tube gain calibration, light response stability, and light-based systematic uncertainties over the course of five years of data collection. In addition, we present a measurement of scintillation light triggering efficiency, focusing on the lowest-light regime relevant to rare-event searches and low-energy neutrino interactions. Finally, we discuss two notable observations in MicroBooNE's data, both reported here for the first time: an approximately 50% decline in MicroBooNE's light yield over time, concentrated in the first two years of running; and a higher than expected O(200 kHz) rate of single photoelectron noise. The results presented provide an important benchmark of long-term light detection performance in LArTPC neutrino detectors.

Abratenko, P. [Tufts U.]↗

Improved heavy-ion PID using scintillation light detector with neural network analysis: a Monte Carlo simulation study

The photon collection efficiency of gaseous scintillator detectors varies according to the position of the impinging charged particles in the medium that generates scintillation light. Thus, when impinging particles are distributed over a large area, the intrinsic photon-number resolution of the system is affected by a large variation. This work presents and discusses a method for adjusting the total number of detected photons to account for variation in the photon collection efficiency as a function of the position of the light source within the scintillating medium. The method was developed and validated by processing data from systematic simulation studies based on GEANT4 that model the response of the Energy Loss Optical Scintillation System (ELOSS) detector. The position of the charged particle is calculated using a deep neural network algorithm. This is accomplished by analyzing the distribution of scintillation light recorded by the array of photosensors. The estimated particle position is then used to calculate the correction factor and adjust the amount of captured light to account for variations in the photon collection efficiency. The neural network algorithm provides excellent tracking capabilities, achieving sub-millimeter position resolution and an angular resolution of 12 mrad, approaching the performance of traditional tracking detectors (e.g., drift chambers). The present method can be generalized to any optical scintillation system where the photon collection efficiency depends on the position of the impinging particle.

Heavy-ion detectors↗

LumaCam: a novel class of position-sensitive event mode particle detectors using scintillator screens

A new type of position-sensitive detectors is gaining attention in the neutron community. They are scintillator based detectors that detect the scintillation light on an individual photon basis via an image intensifier and a fast image sensor. Their readout operates in event mode i.e. it produces information about individual neutron interactions, reconstructed from the sensor data, thus enabling to achieve superior spatial and temporal resolutions compared to regular detectors. Although the development of current detectors is focused on neutrons, the concept is also applicable to the detection of other particles such as high-energy photons. This document provides a description on how these detectors are built, how they operate, and what their characteristics are. An example of a detector implementation based on a Timepix3 chip is described to illustrate the detector concept. This includes a detailed description of the algorithm that reconstructs the neutron interactions from the sensor data, one of the core components that sets it apart from established scintillator-based imaging detectors. Energy-resolved epithermal neutron radiography was performed at the ISIS EMMA beamline with this detector, illustrating some of the fundamental differences in the data that can be produced with the new type of detector compared to more established types of scintillator based neutron detectors. The term LumaCam is proposed to refer to this new class of position-sensitive event-mode detectors.

47 OTHER INSTRUMENTATION↗

The scintillator surface detector of the Pierre Auger observatory

Data collected so far by the Pierre Auger Observatory have enabled major advances in ultra-high energy cosmic ray physics and demonstrated that improved determination of masses of primary cosmic-ray particles, preferably on an event-by-event basis, is necessary for understanding their origin and nature. Improvement in primary mass measurements was the main motivation for the upgrade of the Pierre Auger Observatory, called AugerPrime. As part of this upgrade, scintillator detectors are added to the existing water-Cherenkov surface detector stations. By making use of the differences in detector response to the electromagnetic particles and muons between scintillator and water-Cherenkov detectors, the electromagnetic and muonic components of cosmic-ray air showers can be disentangled. Since the muonic component is sensitive to the primary mass, such combination of detectors provides a powerful way to improve primary mass composition measurements over the original Auger surface detector design. In this paper, the so-called Scintillator Surface Detectors are discussed, including their design characteristics, production process, testing procedure and deployment in the field.

Detector design and construction technologies and ↗

Defect-resistant plastic scintillation radiation detector compositions and fabrication methods

Scintillating plastics resistant to crazing and fogging, methods of making and using the same are disclosed. The scintillating plastics include: one or more primary polymers present in an amount ranging from about 40 wt % to about 95 wt %; one or more secondary polymers present in an amount ranging from about 1 wt % to about 60 wt %; and one or more fluors present in an amount ranging from about 0.1 wt % to about 50 wt %. Methods of making such plastics include: creating a homogenous mixture of precursor materials including primary polymer, secondary polymer, and fluor in the amounts set forth above; and polymerizing the homogenous mixture. Methods of using such plastics include: exposing the scintillating plastic to one or more extreme environmental conditions for a predetermined amount of time without generating crazing or fogging within the scintillating plastic. Various additional features and specific embodiments of these inventive concepts are also disclosed.

36 MATERIALS SCIENCE↗

Photon detector response function methodology using MCNP and shift hybrid radiation transport code for wide-area contamination assay applications

Here, radiation transport modeling using the Monte Carlo N-Particle (MCNP) radiation transport code and Monte Carlo code, Shift, were employed to model detector responses for a variety of wide-area photon contamination scenarios. In this study, 2" × 2" and 3" × 3" cylindrical NaI(Tl) scintillation detector configurations at source detector-distances of 0.5 cm, 1 cm, 2.54 cm, 10 cm, and 30 cm were modeled. Media of soil, concrete, and steel were evaluated for contamination depths ranging from surface to a depth of an infinite thickness in each medium for photon energies ranging from 20 keV to 3 MeV, which correspond to the energies that current detectors can discern. Monoenergetic photon surface contamination detector responses for each of the media, source–detector distances, and detectors were estimated using MCNP v6.2. Shift was harnessed for improved variance reduction of particle transport in highly attenuating media to obtain average cell fluxes in the two MCNP NaI(Tl) scintillation detector configurations. Average cell flux values in Shift were coupled with detector responses from MCNP to convert average cell flux in a void to energy distribution of pulses in the NaI(Tl) scintillation detector crystal of interest. An optimized detector response function methodology was developed by coupling the MCNP radiation transport method with the Consistent Adjoint Driven Importance Sampling (CADIS) hybrid radiation transport method built into Shift to significantly decrease the runtime of thousands of MCNP pulse height simulations. The methodology may be utilized to quickly and accurately facilitate the assessment of a broad range of wide-area environmental contamination assay and decommissioning cleanup applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron capture measurements at UMass lowell research reactor

A new facility was designed around the thermal column beam port of the 1 MW Research Reactor at the University of Massachusetts Lowell. Thermal neutrons are collimated to a 1-inch diameter beam and incident on samples to induce the radiative neutron capture. New measurements of capture gamma rays are planned for Mn, Cu, Ni, Cr, and Gd samples in the next few years. The experiments will be carried out in close collaboration with the ENSDF (Evaluated Nuclear Structure Data File) evaluation group at Brookhaven National Laboratory. The gamma rays are measured using an array of high-resolution HPGe detectors. Some of the HPGe detectors use active Compton shields that were designed from scintillation detectors and improve significantly the signal-to-background in the measured gamma-ray spectra with HPGe. The experimental spectra will be validated by the GEANT4 simulations of the array and theoretical models of the emission of gamma rays from the compound nucleus. In conclusion, the new experimental results on the capture gamma ray intensities will be incorporated in future ENSDF evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗