Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scintillation detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evaluation of light collection from highly scattering media using wavelength-shifting fibers

Opaque scintillators are designed to have a short scattering length such that scintillation photons are probabilistically confined to a small region of space about their origin. The benefit of this feature is that information on the interaction event topology can be recorded with greater fidelity than in traditional highly transparent media with sensors at large distances from the light production region. Opaque scintillator detectors rely on wavelength-shifting fibers to extract the scintillation light; however, the efficiency of light collection has not yet been directly measured in experiment. We measured the efficiency of light collection as a function of the optical parameters of an opaque liquid and the distance from the origin of the light to the fiber. We use the experimental data to validate a Monte Carlo model of light transport and collection and discuss a simple diffusion model that reproduces the results of Monte Carlo simulation with high fidelity. Furthermore, this combination of validated models has the potential for use in predictions of performance in various designs of future opaque scintillator detectors such as LiquidO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proton Quenching in Rare-Earth Inorganic Scintillators: GAGG:Ce and YSO:Ce

Scintillator detectors are an integral component of radiation detection systems for a variety of applications such as medical imaging, accelerator diagnostics, and space science. Typically, a scintillator detector’s response is characterized using gamma sources to understand the detection response to different types of radiation, including charged particle detection. However, there exists a nonlinearity of the amount of light produced from an incident gamma ray of specific energy and the light produced from an incident charged particle of the same energy. This important effect, known as quenching, must be accounted for to interpret energies from charged particles incident on detectors. In this article, we present results of quenching parameterization for two types of cerium-doped inorganic scintillators, Y2SiO5:Ce (YSO:Ce) and Gd3Al2Ga3O12:Ce (GAGG:Ce). We measured the light output from incident proton energies from 1 to 25 MeV using a 3-MV tandem accelerator and two reactions: Au(p,p)Au and 3He(d,p)⁴He. Using gamma-ray sources to calibrate the detectors, we compared the measured electron-equivalent energy versus the incident energy expected. Using an adaptation of the Birks semi-empirical formula, we extracted the Birks parameter (kB) to understand quenching. For one of the GAGG:Ce samples, the kB parameter of 0.0072 [g cm-2 MeV-1] is comparable to a similar study where the value of kB was 0.0065 [g cm-2 MeV-1]. For YSO:Ce, no other kB values were found in the literature. Three different types of GAGG:Ce were used to collect measurements of kB as a function of dopant concentration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

12 C(p,p') 12 C Reaction ( E p =19.5–30 MeV) for Active Interrogation of Special Nuclear Material

Passive detection of special nuclear material (SNM) is challenging due to its inherently low rate of spontaneous emission of penetrating radiation, the relative ease of shielding, and the fluctuating and frequently overwhelming background. Active interrogation, the use of external radiation to increase the emission rate of characteristic radiation from SNM, has long been considered to be a promising method to overcome those challenges. Current active-interrogation systems that incorporate radiography tend to use bremsstrahlung beams, which can deliver high radiation doses. Low-energy ion-driven nuclear reactions that produce multiple monoenergetic photons may be used as an alternative. The 12 C ( p , p ' ) 12 C reaction is one such reaction that could produce large yields of highly penetrating 4.4- and 15.1-MeV gamma rays. This reaction does not directly produce neutrons below the approximately 19.7 MeV threshold, and the 15.1-MeV gamma-ray line is well matched to the photofission cross section of 235 U and 238 U . In this article, we report the measurements of thick-target gamma-ray yields at 4.4 and 15.1 MeV from the 12 C ( p , p ' ) 12 C reaction at proton energies of 19.5, 25, and 30 MeV. Measurements are made with two 3 -in. EJ-309 cylindrical liquid scintillation detectors and thermoluminescent dosimeters placed at 0 ° and 90 ° , with an additional 1.5 -in. Na I ( Tl ) cylindrical scintillation detector at 0 ° . We estimate the highest yields of the 4.4- and 15.1-MeV gamma rays of 1.65 × 10 10 and 4.47 × 10 8 sr - 1 μ C - 1 at a proton energy of 30 MeV, respectively. The yields in all experimental configurations are greater than in a comparable deuteron-driven reaction that produces the same gamma-ray energies— 11 B ( d , n γ ) 12 C . However, a significant increase of the neutron radiation dose accompanies the proton energy increase from 19.5 to 30 MeV.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Spectral Hardness of X- and Gamma-Ray Emissions From Lightning Stepped and Dart Leaders

During the 2022 New Mexico monsoon season, we deployed two X-ray scintillation detectors, coupled with a 180 MHz data acquisition system to detect X-rays from natural lightning at the Langmuir Lab mountain-top facility, located at 3.3 km above mean sea level. Data acquisition was triggered by an electric field antenna calibrated to pick up lightning within a few km of the X-ray detectors. We report the energies of over 240 individual photons, ranging between 13 keV and 3.8 MeV, as registered by the LaBr3(Ce) scintillation detector. These detections were associated with four lightning flashes. Particularly, four-stepped leaders and seven dart leaders produced energetic radiation. Importantly, the reported photon energies allowed us to confirm that the X-ray energy distribution of natural stepped and dart leaders follows a power-law distribution with an exponent ranging between 1.09 and 1.96, with stepped leaders having a harder spectrum. Characterization of the associated leaders and return strokes was done with four different electric field sensing antennas, which can measure a wide range of time scales, from the static storm field to the fast change associated with dart leaders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of scintillated imaging detectors for MeV X-ray radiography

Radiographic imaging at X-ray energies in the MeV range poses a complex problem. Detection of high energy X-rays depends heavily on the ability of the detection material, in this work the scintillator, to attenuate and ultimately stop the X-ray. Attenuation is more readily achieved by increasing material thickness, however thick scintillators are plagued with relatively high internal scattering, leading to an overall decrease in spatial resolution and image quality.

42 ENGINEERING↗

Analysis of fusion alphas interaction with RF waves in D-T plasma at JET

This work studies the influence of RF waves in ICRH range of frequency on fusion alphas during the recent JET D-T campaign. Fusion alphas from D-T reactions are born with energies of about 3.5MeV and therefore have significant Doppler shift enabling synergistic interaction between them and RF waves at broad range of frequencies including the ones foreseen for future fusion machines ITER and SPARC. Resonant interaction between RF waves and alphas, also called synergistic effects, will modify the alpha distribution and ultimately will have an impact on alpha orbit losses and heating. Data from JET 3.43T/2.3MA pulses based on the hybrid scenario during the DTE2 campaign were used for the analysis in this study. The impact of synergistic effects on alpha orbit losses and alpha heating is assessed. Conclusions are based on analysis of experimental data for fast alphas losses, i.e. measurements from neutral particle analyser, fast ion losses scintillator detector, Faraday cups, and TRANSP simulations. Experimental data and TRANSP analysis indicate that there are indeed changes in the alphas' distribution function due to interaction with RF waves. Data from the scintillator detector and the Faraday cups were compared for pulses with and without ICRH power and versus cases with enhanced alpha losses due to MHD activities. The trends from these diagnostics consistently show no additional alpha losses due to interaction with RF waves. TRANSP predictions for the impact of the synergistic effects on alpha heating show up to 42% increase in alpha electron heating and up to 25% increase in alpha ion heating. These effects however become negligibly small, less than 1%, when alpha heating is compared to the total auxiliary hearting power in the investigated JET pulses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field Test Report Neutron Scintillator Array Dry Storage Cask Scanner FY2024

During two weeks of Field Testing at the Idaho National Laboratory INTEC Cask Farm in July and August 2024, the LLNL Dry Storage Cask Scanner Array was lifted on top of an MC-10 dry storage fuel cask and operated to acquire neutron and gamma-ray data from the 24 fuel bundle positions. Neutron and gamma-ray data acquisition scans across the top of the cask of varying dwell times were performed July 15-18, 2024 and August 19-22, 2024 to evaluate the ability of the scanner data to reveal asymmetries in the fuel positions that reflect asymmetries in the MC-10 cask fuel bundle loading. The MC-10 cask 24 position fuel bundle loading at the INTEC Cask Farm is well documented, including the locations of six empty fuel bundle positions. This loading presents an opportunity to test the ability of the scanner system to detect diversion of spent fuel bundles as well as to validate the MC-10 cask MCNP modeling. The cask scanner array consists of six Stilbene crystal scintillator detectors and a linear actuator frame that moves the six detectors across the MC-10 dry storage cask to obtain data above each of the 24 fuel bundle positions. The detectors are connected to a pulse-shape discrimination data acquisition system capable of generating separate neutron and gamma-ray spectra for each detector and for each scan position. From the prior single detector Field Test in 2021 and iteration with MCNP modeling, the neutron and gamma-ray data were analyzed in multiple energy regions to identify an analysis method that would provide the strongest and most consistent signature of the asymmetric MC-10 cask fuel loading1 . From both the 2021 Field Test and the current Field Test results, the neutron capture gamma-ray count rate around 2.2 MeV provides the strongest signature of the asymmetric MC-10 cask fuel loading and has qualitative agreement with MCNP calculations. Counting all gamma-rays produces a similar signature. Neutrons emerging from the cask top are moderated and captured by the hydrogen in the polyethylene moderator and scintillator detector, producing a 2.2 MeV gamma ray which is seen in the scintillator gamma-ray spectrum. The count rate in the 2.2 MeV gamma-ray region is ~50 c/s, which is ~1000x higher than the ~0.05 n/s rate in the > 4MeV neutron region, and ~50x greater than the ~1 n/s rate in the neutrons > 500 keV region. Analysis of the 2.2 MeV neutron-capture Compton-scattered gamma-rays produces a statistically significant signature of the INTEC Cask Farm MC-10 asymmetric fuel loading. MCNP simulations indicate that the average neutron energy spectrum offers the potential to detect a large asymmetry from several missing bundles as well as individual missing fuel bundles. Testing this feature will require measurements on a cask with single missing elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Research and Development Studies for Reactor Neutrino Experiments in Turkey (RNET)

The program of the Reactor Neutrino Experiments of Turkey includes a small portable Water-based liquid scintillator detector to detect neutrinos from the Akkuyu nuclear power plant, planned to begin operating in 2023. The small near-field detector will weigh about 2-3 tons and will be placed less than 100 meters from the reactor cores. The Reactor Neutrino Experiments of Turkey program also includes a medium-size 30-ton Water-based liquid scintillator detector, which will be placed 1-2 km away from the reactor cores and will be used as a far detector. Both detectors and their responses to neutrino interactions were simulated using a GEANT4-based RAT-PAC simulation package. Here, we will share the technical and physical details of both detectors, and discuss the ongoing R&D effort for neutrino studies in Turkey.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of a deuterated detector for gamma-ray beam intensity measurements

Laser-Compton scattering sources of quasi-monochromatic γ-ray beams have been in operation for over 30 years, with new facilities being under construction or proposed. To sustain a high-quality experimental physics program, continuous monitoring of these beams is essential by measuring the spectral, temporal, and spatial characteristics. In this work, we introduce a new method for determining the γ-ray beam intensity by using photodisintegration of deuterons in an active target detector approach. Measurements were performed using deuterated liquid scintillator detectors at several incident gamma energies between 4 and 13 MeV at the High Intensity γ-ray Source, Durham, USA. The results demonstrate that an instrument based on a deuterated active detector can be used to monitor the intensity of the γ-ray beam with high efficiency and operational simplicity.

Compton scattering↗

A portable and monoenergetic 24 keV neutron source based on 124Sb-9Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the 124Sb-9Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from 124Sb decays while letting through the neutrons. To increase the 124Sb activity and thus the neutron flux, a >1 GBq 124Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20–25 keV to be 6.00±0.30 neutrons per cm2 per second and the total gamma flux to be 245±8 gammas per cm2 per second (numbers scaled to 1 GBq activity of the 124Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

Dark Matter detectors (WIMPs, axions, etc.)↗

Development of a Convolutional Neural Network Classifier for Data Starved Spectra - 20199

The Institute for Clean Energy Technology (ICET) at Mississippi State University is exploring the utility of machine learning in augmenting its mobile radiation surveying platforms, which are currently being developed as means to survey depleted uranium contaminated areas in support of remediation and decommissioning efforts. Mobile survey platforms provide a means to efficiently scan large areas of interest while reducing human exposure to radiation and other hazards. The survey platforms can also be used for scanning for any gamma emitting isotope in addition to depleted uranium. The spectral data that the platforms collect may be data starved with relatively low counts and poorly defined spectral features depending on the speed of the platforms and scintillation detector selection. Such data-starved spectra are difficult to use for isotope identification, requiring advanced knowledge of the possible radionuclides that could be present and environmental factors that could attenuate signals or introduce background noise. These factors in combination with the volume of survey data increases the time it takes to perform analysis of survey data when the source type is unknown. There are a number of algorithms in the field of machine learning that can be used to classify data that would be challenging and time-consuming for a human to identify. Supervised machine learning algorithms train models based on extensive amounts of human-labeled training data. Once sufficiently trained, these models can be used to quickly make high-fidelity predictions on new data. Convolutional neural networks are machine learning algorithms that excel in learning representations of 'shapes'. They do this by taking numerical input data and convolving them with spatial feature detectors referred to as filters. These filters are incrementally adjusted to reduce the prediction error on the data during the backpropagation step of training. Discussed in this paper is the development of a convolutional neural network classifier (CNNC) that can utilize spectral survey data for source discrimination and isotope identification. Bench-top laboratory experiments data using LaBr{sub 3}(Ce) scintillation detectors were used to train and evaluate the performance of the developed CNNC. The CNNC is capable of discriminating a variety of gamma emitting source types, differentiating different forms of uranium (depleted vs. natural), and estimating the amount of uranium for a known geometry. The discussed CNNC may be useful in scenarios where survey systems are deployed in situations where hazardous radioactive material maybe present, but the type is unknown. When used in remediation applications the CNNC can be used to screen-out false positives, helping reduce remediation costs. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

DUAL-PARTICLE DOSEMETER BASED ON ORGANIC SCINTILLATOR

Abstract Traditionally available handheld dosemeters are generally sensitive to only one type of radiation: neutrons or photons. Some dosemeters also rely on very specific attenuation correlations between response and dose, are not scalable in size and multiple dosemeters are required to characterise mixed-particle fields. The research presented here serves as a proof-of-concept for a method to simultaneously measure dose rates from neutrons and photons using a particle discriminating organic scintillation detector without the need for spectral deconvolution. The method was compared with traditional instruments and to simulation. Isotopic photon dose rates measured with this method were within 4% of simulated truth, whereas fission spectrum neutron dose rates were measured within 21%. Measurements of dose rates from both particles agree with simulated truth better than traditional instruments. This new method allows for measurement of dose equivalent from both neutrons and photons with a single instrument and no reliance on spectral deconvolution.

Miller, C. A.↗

Silicon Photomultipliers Coupled to Scintillators With the Emission Maximum at 550 nm

A majority of the silicon photomultipliers (SiPMs) are sensitive to blue and near-ultraviolet (NUV) photons that are not optimized for scintillators with the emission maximum at wavelengths longer than 500 nm. The red–green–blue (RGB) SiPM is developed for the maximum photon detection efficiency (PDE) at 550 nm, which is a good match for some high-light-yield scintillators, such as CsI:Tl (CsI) and Gd 1.5 Y 1.5 Ga 2 Al 3 O 12 :Ce (GYGAG). Comparisons are made for the performance of these scintillators coupled to the RGB SiPM and a blue-sensitive SiPM. Because it takes tens of nanoseconds for the microcells to recharge after registering a photon hit, the linearity of these scintillation detectors was studied for high-energy gammas where numerous scintillation photons are generated. In addition, the energy resolution of the 662-keV gamma emitted by 137 Cs was measured for temperatures between –20 °C and 50 °C. The nonlinearity was observed above 1 MeV for all measurements, and however, it can be corrected by energy calibration using a third-degree polynomial. For CsI, the energy resolution is better with the blue-sensitive SiPM because of the lower dark count rate (DCR). In contrast, GYGAG coupled to the RGB SiPM has a better energy resolution for temperatures below 30 °C because of the well-matched emission spectrum and PDE distribution. Nevertheless, the advantage disappears for temperatures above 30 °C due to the higher DCR. It would be useful to further develop the RGB SiPM with a lower DCR and higher operating temperatures.

42 ENGINEERING↗

Analysis of 83m Kr prompt scintillation signals in the PIXeY detector

Prompt scintillation signals from 83m Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber. Because 83m Kr decays in two steps, there are two prompt scintillation pulses for each calibration event, denoted S1a and S1b. We study the ratio of S1b to S1a signal sizes in the Particle Identification in Xenon at Yale (PIXeY) experiment and its dependence on the time separation between the two signals (Δ t), notably its increase at low Δ t. Finally, in PIXeY data, the Δ t dependence of S1b/S1a is observed to exhibit two exponential components: one with a time constant of 0.05 ± 0.02 μ s, which can be attributed to processing effects and pulse overlap and one with a time constant of 10.2 ± 2.2 μs that increases in amplitude with electric drift field, the origin of which is not yet understood.

47 OTHER INSTRUMENTATION↗