Search NASA⌕ Search

SEARCH · Search NASA

Results for “Screening design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Ocular Screening System

An ocular screening system designed for safe, convenient screening of large groups was developed at Marshall Space Flight Center, leading to the formation of Medical Sciences Corporation. The system identifies visual defects accurately and inexpensively, and includes a photorefractor telephoto lens and an electronic flash. Medical Sciences Corporation is using the device to test at schools, industrial plants, etc.

Source record↗

Volumetric 3D Display System with Static Screen

Current display technology has relied on flat, 2D screens that cannot truly convey the third dimension of visual information: depth. In contrast to conventional visualization that is primarily based on 2D flat screens, the volumetric 3D display possesses a true 3D display volume, and places physically each 3D voxel in displayed 3D images at the true 3D (x,y,z) spatial position. Each voxel, analogous to a pixel in a 2D image, emits light from that position to form a real 3D image in the eyes of the viewers. Such true volumetric 3D display technology provides both physiological (accommodation, convergence, binocular disparity, and motion parallax) and psychological (image size, linear perspective, shading, brightness, etc.) depth cues to human visual systems to help in the perception of 3D objects. In a volumetric 3D display, viewers can watch the displayed 3D images from a completely 360 view without using any special eyewear. The volumetric 3D display techniques may lead to a quantum leap in information display technology and can dramatically change the ways humans interact with computers, which can lead to significant improvements in the efficiency of learning and knowledge management processes. Within a block of glass, a large amount of tiny dots of voxels are created by using a recently available machining technique called laser subsurface engraving (LSE). The LSE is able to produce tiny physical crack points (as small as 0.05 mm in diameter) at any (x,y,z) location within the cube of transparent material. The crack dots, when illuminated by a light source, scatter the light around and form visible voxels within the 3D volume. The locations of these tiny voxels are strategically determined such that each can be illuminated by a light ray from a high-resolution digital mirror device (DMD) light engine. The distribution of these voxels occupies the full display volume within the static 3D glass screen. This design eliminates any moving screen seen in previous approaches, so there is no image jitter, and has an inherent parallel mechanism for 3D voxel addressing. High spatial resolution is possible with a full color display being easy to implement. The system is low-cost and low-maintenance.

Geng, Jason↗

Inverse Band Structure Design via Materials Database Screening: Application to Square Planar Thermoelectrics

Electronic band structure contains a wealth of information on the electronic properties of a solid and is routinely computed. However, the more difficult problem of designing a solid with a desired band structure is an outstanding challenge. In order to address this inverse band structure design problem, we devise an approach using materials database screening with materials attributes based on the constituent elements, nominal electron count, crystal structure, and thermodynamics. Our strategy is tested in the context of thermoelectric materials, for which a targeted band structure containing both flat and dispersive components with respect to crystal momentum is highly desirable. We screen for thermodynamically stable or metastable compounds containing d 8 transition metals coordinated by anions in a square planar geometry in order to mimic the properties of recently identified oxide thermoelectrics with such a band structure. In doing so, we identify 157 compounds out of a total of over half a million candidates. After further screening based on electronic band gap and structural anisotropy, we explicitly compute the band structures for the several of the candidates in order to validate the approach. We successfully find two new oxide systems that achieve the targeted band structure. Electronic transport calculations on these two compounds, Ba 2 PdO 3 and La 4 PdO 7 , confirm promising thermoelectric power factor behavior for the compounds. This methodology is easily adapted to other targeted band structures and should be widely applicable to a variety of design problems.

36 MATERIALS SCIENCE↗

Multiparameter Screening on SlipChip Used for Nanoliter Protein Crystallization Combining Free Interface Diffusion and Microbatch Methods

This paper describes two SlipChip-based approaches to protein crystallization: a SlipChip-based free interface diffusion (FID) method and a SlipChip-based composite method that simultaneously performs microbatch and FID crystallization methods in a single device. The FID SlipChip was designed to screen multiple reagents, each at multiple diffusion equilibration times, and was validated by screening conditions for crystallization of two proteins, enoyl-CoA hydratase from Mycobacterium tuberculosis and dihydrofolate reductase/thymidylate synthase from Babesia bovis, against 48 different reagents at five different equilibration times each, consuming 12 {micro}L of each protein for a total of 480 experiments using three SlipChips. The composite SlipChip was designed to screen multiple reagents, each at multiple mixing ratios and multiple equilibration times, and was validated by screening conditions for crystallization of two proteins, enoyl-CoA hydratase from Mycobacterium tuberculosis and dihydrofolate reductase/thymidylate synthase from Babesia bovis. To prevent cross-contamination while keeping the solution in the neck channels for FID stable, the plates of the SlipChip were etched with a pattern of nanowells. This nanopattern was used to increase the contact angle of aqueous solutions on the surface of the silanized glass. The composite SlipChip increased the number of successful crystallization conditions and identified more conditions for crystallization than separate FID and microbatch screenings. Crystallization experiments were scaled up in well plates using conditions identified during the SlipChip screenings, and X-ray diffraction data were obtained to yield the protein structure of dihydrofolate reductase/thymidylate synthase at 1.95 {angstrom} resolution. This free-interface diffusion approach provides a convenient and high-throughput method of setting up gradients in microfluidic devices and may find additional applications in cell-based assays.

59 BASIC BIOLOGICAL SCIENCES↗

Optimizing Hammermill Performance Through Screen Selection and Hammer Design

Background: Mechanical preprocessing, which includes particle size reduction and mechanical separation, is one of the primary operations in the feedstock supply system for a lignocellulosic biorefinery. It is the means by which raw biomass from the field or forest is mechanically transformed into an on-spec feedstock with characteristics better suited for the fuel conversion process. Results: This work provides a general overview of the objectives and methodologies of mechanical preprocessing and then presents experimental results illustrating (1) improved size reduction via optimization of hammer mill configuration, (2) improved size reduction via pneumatic-assisted hammer milling, and (3) improved control of particle size and particle size distribution through proper selection of grinder process parameters. Conclusion: Optimal grinder configuration for maximal process throughput and efficiency is strongly dependent on feedstock type and properties, such moisture content. Tests conducted using a HG200 hammer grinder indicate that increasing the tip speed, optimizing hammer geometry, and adding pneumatic assist can increase grinder throughput as much as 400%.

09 BIOMASS FUELS↗

Composition Driven, Statistical Review of Cast Stone Screening Matrix Results

Recent studies in support of Cast Stone development for the Hanford Site were designed to screen the effects of mix components on properties and performance of the waste form. Dry blend components, including portland cement, blast furnace slag, and Class F fly ash, sourced from both southeastern and northwestern suppliers, were included in the screening matrix. Multiple decontaminated salt solutions (simulated) were combined with the dry blend components at various liquid to solid ratios following a statistically designed matrix of compositions. Properties of the resulting mixes and performance of the cured materials were then measured and related to the dry blend components and salt solutions that were used for each mix. At the conclusion of the screening matrix work, SRNL felt that additional insight into the study might be obtained by relating the properties and performance of the materials to the composition of each Cast Stone mix, as opposed to just the dry blend – salt solution combination. This memorandum provides the results of a statistically driven review of the screening matrix data as a function of the composition of each mix. It is meant to augment the results obtained by reviewing the screening matrix data as a function of the dry blend and salt solution combination.

Edwards, T. B.↗

Design and Analyses of High Aspect Ratio Nozzles for Distributed Propulsion Acoustic Measurements

A series of three convergent, round-to-rectangular high aspect ratio (HAR) nozzles were designed for acoustic testing at the NASA Glenn Research Center Nozzle Acoustic Test Rig (NATR). The HAR nozzles had exit area aspect ratios of 8:1, 12:1, and 16:1. The nozzles were designed to mimic a distributed propulsion system array with a slot nozzle. The nozzle designs were screened using Reynolds-Averaged Navier-Stokes (RANS) simulations. In addition to meeting the geometric constraints required for testing in the NATR, the HAR nozzles were designed to be free of flow features that would produce unwanted noise (e.g., flow separations) and to have uniform flow at the nozzle exit. Multiple methods were used to generate HAR nozzle designs. The final HAR nozzle designs were generated in segments using a computer code that parameterized each segment. RANS screening simulations showed that intermediate nozzle designs suffered flow separation, a normal shockwave at the nozzle exit (caused by an aerodynamic throat produced by boundary layer growth), and non-uniform flow at the nozzle exit. The RANS simulations showed that the final HAR nozzle designs were free of flow separations, but were not entirely successful at producing a fully uniform flow at the nozzle exit. The final designs suffered a pair of counter-rotating vortices along the outboard walls of the nozzle. The 16:1 aspect ratio HAR nozzle had the least uniform flow at the exit plane; the 8:1 aspect ratio HAR nozzles had a fairly uniform flow at the nozzle exit plane.

acoustic measure↗

Enhanced Attenuation of Uranium in the Subsurface

Over time, the focus for the Hanford Site has moved from production to decommissioning and site remediation. Several hundred metric tons of near-surface vadose zone sediment have been excavated from the 300 Area in an effort to remove the source of the uranium contamination (DOE/RL, 2011). Despite remediation efforts, uranium continues to be problematic with concentrations greater than the maximum contaminant level (MCL, which is 30 µg/L) for drinking water. Due to the close proximity of the Columbia River, the uranium continues to be a focus of investigation and remediation. After finding that the uranium concentrations were not decreasing as quickly as expected (based on the 1996 ROD) the Tri-Parties set new milestones, including an update of the conceptual model for the 300 Area uranium plume (Williams et al., 2007). In order to more accurately complete a feasibility study and identify how to remediate the uranium in the groundwater, the DOE authorized a remedial investigation/feasibility study (RI/FS). RI/FSs are designed to screen technologies to determine effectiveness, implementability, and cost (see Chapter 2b). These studies are designed to be conducted concurrently as part of the CERCLA process, so the data collected during site characterization (part of the RI) can inform the treatability studies and field tests conducted under the FS (EPA 1988). For the 300 Area, this study included laboratory, field, and modeling components as well as additional sediment and groundwater characterization to determine a suitable remediation strategy to reduce the uranium concentration in the groundwater plume within the expected time frame and cost.

300 area, uranium, polyphosphate, Hanford book pro↗

WE-D-207-00: CT Lung Cancer Screening and the Medical Physicist: Moving Forward

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

WE-D-207-01: Background and Clinical Implementation of a Screening Program

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

WE-D-207-02: Capturing Data Elements and the Role of Imaging Informatics

In the United States, Lung Cancer is responsible for more cancer deaths than the next four cancers combined. In addition, the 5 year survival rate for lung cancer patients has not improved over the past 40 to 50 years. To combat this deadly disease, in 2002 the National Cancer Institute launched a very large Randomized Control Trial called the National Lung Screening Trial (NLST). This trial would randomize subjects who had substantial risk of lung cancer (due to age and smoking history) into either a Chest X-ray arm or a low dose CT arm. In November 2010, the National Cancer Institute announced that the NLST had demonstrated 20% fewer lung cancer deaths among those who were screened with low-dose CT than with chest X-ray. In December 2013, the US Preventive Services Task Force recommended the use of Lung Cancer Screening using low dose CT and a little over a year later (Feb. 2015), CMS announced that Medicare would also cover Lung Cancer Screening using low dose CT. Thus private and public insurers are required to provide Lung Cancer Screening programs using CT to the appropriate population(s). The purpose of this Symposium is to inform medical physicists and prepare them to support the implementation of Lung Screening programs. This Symposium will focus on the clinical aspects of lung cancer screening, requirements of a screening registry for systematically capturing and tracking screening patients and results (such as required Medicare data elements) as well as the role of the medical physicist in screening programs, including the development of low dose CT screening protocols. Learning Objectives: To understand the clinical basis and clinical components of a lung cancer screening program, including eligibility criteria and other requirements. To understand the data collection requirements, workflow, and informatics infrastructure needed to support the tracking and reporting components of a screening program. To understand the role of the medical physicist in implementing Lung Cancer Screening protocols for CT, including utilizing resources such as the AAPM Protocols and the ACR Designated Lung Screening Center program. UCLA Department of Radiology has an Institutional research agreement with Siemens Healthcare; Dr. McNitt-Gray has been a recipient of Research Support from Siemens Healthcare in the past. Dr. Aberle has been a Member of Advisory Boards for the LUNGevity Foundation (2011-present) and Siemens Medical Solutions. (2013)

60 APPLIED LIFE SCIENCES↗

Ultrafast creation of a light-induced semimetallic state in strongly excited 1T-TiSe 2

Screening, a ubiquitous phenomenon associated with the shielding of electric fields by surrounding charges, has been widely adopted as a means to modify a material’s properties. While most studies have relied on static changes of screening through doping or gating thus far, here we demonstrate that screening can also drive the onset of distinct quantum states on the ultrafast timescale. By using time- and angle-resolved photoemission spectroscopy, we show that intense optical excitation can drive 1T-TiSe 2 , a prototypical charge density wave material, almost instantly from a gapped into a semimetallic state. By systematically comparing changes in band structure over time and excitation strength with theoretical calculations, we find that the appearance of this state is likely caused by a dramatic reduction of the screening length. In summary, this work showcases how optical excitation enables the screening-driven design of a nonequilibrium semimetallic phase in TiSe 2 , possibly providing a general pathway into highly screened phases in other strongly correlated materials.

36 MATERIALS SCIENCE↗

Selection and Characterization of Vegetable Crop Cultivars for use in Advanced Life Support Systems

Cultivar evaluation for controlled environments is a lengthy and multifaceted activity. The chapters of this thesis cover eight steps preparatory to yield trials, and the final step of cultivar selection after data are collected. The steps are as follows: 1. Examination of the literature on the crop and crop cultivars to assess the state of knowledge. 2. Selection of standard cultivars with which to explore crop response to major growth factors and determine set points for screening and, later, production. 3. Determination of practical growing techniques for the crop in controlled environments. 4. Design of experiments for determination of crop responses to the major growth factors, with particular emphasis on photoperiod, daily light integral and air temperature. 5. Developing a way of measuring yield appropriate to the crop type by sampling through the harvest period and calculating a productivity function. 6. Narrowing down the pool of cultivars and breeding lines according to a set of criteria and breeding history. 7. Determination of environmental set points for cultivar evaluation through calculating production cost as a function of set points and size of target facility. 8. Design of screening and yield trial experiments emphasizing efficient use of space. 9. Final evaluation of cultivars after data collection, in terms of production cost and value to the consumer. For each of the steps, relevant issues are addressed. In selecting standards to determine set points for screening, set points that optimize cost of production for the standards may not be applicable to all cultivars. Production of uniform and equivalent- sized seedlings is considered as a means of countering possible differences in seed vigor. Issues of spacing and re-spacing are also discussed.

Langhans, Robert W.↗

Simple Low-Frequency Beam Pickup

Detection of the field induced by a beam outside of the beam pipe can be used as a beam diagnostic. Wires placed in longitudinal slots in the outside wall of the beam pipe can be used as a beam pickup. This has a very small beam-coupling impedance and avoids complications of having a feedthrough. The signal can be reasonably high at low frequencies. We present a field waveform at the outer side of a beam pipe, obtained as a result of calculations and measurements. We calculate the beam-coupling impedance due to a long longitudinal slot in the resistive wall and the signal induced in a wire placed in such a slot and shielded by a thin screen from the beam. These results should be relevant for impedance calculations of the slot in an antechamber and for slots in the PEP-II distributed ion pump screens. The design of the low-frequency beam position monitor is very simple. It can be used in storage rings, synchrotron light sources, and free electron lasers, like LINAC coherent light source.

43 PARTICLE ACCELERATORS↗