Search NASA⌕ Search

SEARCH · Search NASA

Results for “Seat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

66 records · Page 4

Constraining the Dynamo Layers in Jupiter and Saturn with Observations and Scaling Laws

The dipole-dominated magnetic fields of Jupiter and Saturn provide evidence for active dynamos operating within their deep interiors, yet the depth of the convecting dynamo layers remains poorly constrained. While magnetic field observations, gravity data, and interior models each provide partial insight, they have not been combined into a single, self-consistent picture of the internal structure. Here, we develop a framework that links observed magnetic field strength with intrinsic heat flux and gravity-constrained interior structure using energy-based dynamo scaling laws. By relating the axial magnetic field strength to the convective power, we infer the radial thickness of the dynamo-generating region for both Jupiter and Saturn. The constants of proportionality in the scaling relations are derived using independent constraints from Earth observations, Jupiter observations, and numerical dynamo simulations. Applied to Jupiter, this framework shows how the inferred dynamo layer thickness is coupled to the outer boundary of the dynamo region. Thinner dynamo layers are predicted when the outer boundary shifts to shallower depths, and no solutions are possible when the outer boundary is less than 73% of Jupiter’s radius. These results constrain plausible geometries for future numerical dynamo simulations. Extending the analysis to Saturn, we find a thick, deep-seated dynamo layer with an outer radius at 42% of the radius to be most plausible. An alternative solution with an inner radius of the dynamo region at 60% of the planetary radius, as suggested by ring seismology models, requires a very thin dynamo layer, occupying only 2%–3% of the total radius.

Geosciences↗

Combined Mesonet and Tracker

Title: Combined Mesonet and Trackers (UNL Mobile Mesonets) Authors University of Nebraska PI: Adam Houston, UNL Professor (ahouston2@unl.edu) Mailing Address: 126 Bessey Hall P.O. Box 880340 Lincoln, NE 68588-0340 CoMeT Overview The University of Nebraska-Lincoln operates three Combined Mesonet and Tracker (CoMeTs). CoMeTs are Ford Explorers (model years 2015, 2017, and 2019) with forward-mounted suites of meteorological sensors and dual moonroofs, combining the capability of a mobile mesonet to collect near-surface observations with the capability of an unmanned aircraft systems (UAS) tracker vehicle, which enables an observer in the second row of seats to see the aircraft and maintain compliance with Federal Aviation Administration policies on UAS operation. The CoMeTs collect observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155A, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, and vehicle heading using a KVH Industries C-100 fluxgate compass (Barbieri et al. 2019). The HMP155A and 109SS-L thermistor are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). This list of sensors is also included in the CoMeT data file metadata. Manufacturer specifications for these instruments are given in Table 1 of Hanft and Houston (2018). The reported measured quantities are summarized below.CoMeT-3 was funded through an equipment allocation included in the NSF TORUS award (AGS-1824649). Instrument Description The specific sensors included on each CoMeT are summarized in the table at the end of this section. In general each CoMeT collects observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210 barometer with a Gill pressure port, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, position using a Garmin 19x HVS receiver, and vehicle heading using a KVH Industries C-100 fluxgate compass. The HMP155 and 109SS are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). Fast temperature and corrected RH measurements (using sensors housed within the U-tube) have a time constant of 10-12 s based on data collected across a temperature and RH shock during the CLOUD-MAP 2017 calibration/validation tests on June 26, 2017. Vehicle speed was < 10 kts for this test. CoMeT-1 CoMeT-2 CoMeT-3 Slow Temperature Slow RH Vaisala HMP155A-L20-PT Part #: 22280-7 Vaisala HMP155E Part #: E1AA11A0B1A1A0A Vaisala HMP155E Part #: E1AA11A0B1A1A0A Fast temperature Campbell Scientific 109SS-L20-PT Part #: 21448-3 Campbell Scientific 109SS-L12-PW Part #: 21448-109 Campbell Scientific 109SS-L12-PW Part #: 21448-150 Pressure Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Wind RM Young 05103-L20-PT Part #: 18435-310 RM Young 05103-L20-PW Part #: 18435-244 RM Young 05103-L20-PW Part #: 18435-244 GPS Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Compass KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 Logger Campbell Scientific CR6-NA-XT-SW Part #: 28385-9 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Data Collection and Real-Time Processing The reported measured quantities are summarized in the table below. Quantity Units Source Epoch time Seconds GPS Latitude and longitude Degrees GPS Altitude m GPS Pressure hPa PTB210 Temperature (fast) deg C 109SS-L Temperature (slow) deg C HMP155 RH (slow) % HMP155 Vehicle speed m/s GPS Vehicle heading deg C-100 and GPS In addition to the measured variables, several derived variables are calculated. Corrected/fast relative humidity (%) Relative humidity is adjusted to the fast temperature following Richardson et al. (1998) and Houston et al. (2016). Water vapor mixing ratio (g/kg) Dew point temperature (&deg;C) Potential temperature (Kelvin) Virtual potential temperature (Kelvin) Equivalent potential temperature (Kelvin) Regular intercomparisons between all three CoMeTs were performed during TORUS 2019. Comparisons were also conducted between CoMeT-1 and CoMeT-2 during LAPSE-RATE (2018) on 14 July. In these intercomparisons, the vehicles were parked adjacent to each other aligned perpendicular to (and facing into) the wind. To minimize engine heating effects, intercomparisons were only conducted when the wind speed was >10 kts. Data Format Original data files for each deployment are saved as text files and then converted to NetCDF. NetCDF versions have units that are CF compliant and may not match the original units in the txt files. The naming convention for the NetCDF files is as follows: UNL.CoMeT3.{deployment date YYYYMMDD}.{start time of observation collection in UTC HHMM}.L2.{post-processing codes}.cdf example: UNL.CoMeT3.20190627.1931.L2.g1.f1.cdf Post-processing codes are included to track modifications to the raw data. These codes are closely connected to error flags associated with each record. Each letter corresponds to a particular instrument: g: GPS p: Barometer tf: Fast temperature ts: Slow temperature rh: Relative humidity f: Compass w: Wind monitor a: All instruments Each number corresponds to a particular post-processing action described more below. Measured and derived variables are included in the following table. Variable Heading Standard Name Units time Time seconds since 00:00:00, 01-01-1970 Alt Altitude meters lat Latitude degrees north lon Longitude degrees east fast_temp Air Temperature kelvin slow_temp Air Temperature kelvin pressure Air Pressure pascals logger_RH Relative Humidity percent calc_corr_RH Relative Humidity percent wind_speed Wind Speed meters per second wind_dir Wind From Direction degrees vehicle_dir Vehicle Direction degrees dewpoint Dew Point Temperature kelvin mixing_ratio Humidity Mixing Ratio g/g theta Air Potential Temperature kelvin theta_v Virtual Potential Temperature kelvin theta_e Equivalent Potential Temperature Kelvin error_flag The error_flag variable is a string that matches the post-processing codes listed above. All instruments will have an associated code, but will have a &ldquo;0&rdquo; if the datum is unchanged from the initial processed value. Error Codes The following table summarizes the error codes for data collected before 2020: Error Code Relevant CoMeT Description g1 1,2,3 Exact correction. GPS position and time reprocessed from raw data g2 1 As far as we can tell this is an exact correction to an error in the GPS time. During the correct time periods the time suddenly went backwards ~250s and stayed at this offset for 750s when it corrected itself. The offset was applied to the &ldquo;time warp&rdquo; period. p1 2 Approximate correction. Hole in the pressure tube connecting the pressure port to the barometer. Resulted in erroneously low air pressure measurements when the vehicle was in motion. Derived variables recalculated (dew point temperature [e depends on qv and p], water vapor mixing ratio, potential temperature, virtual potential temperature, equivalent potential temperature) a1 3 Exact correction. Missing data reprocessed from raw data a2 1 Bug fix to bias correction for ts1, ts2, and rh1: water vapor mixing ratio was off by a factor of 10 and virtual potential temperature was wrong because of this. f1 3 No correction, missing data. Fluxgate compass inoperable. Wind speed and direction calculated using GPS-derived vehicle heading instead. rh1 1 Approximate correction. Constant bias of +1.7% removed from relative humidity. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts1 1 Approximate correction. Constant bias of +0.6 K removed from slow temperature. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts2 1 Approximate correction. Constant bias of +1.0 K removed. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) References Bolton, D., 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., 108, 1046&ndash;1053, https://doi.org/10.1175/1520-0493(1980)108<1046:TCOEPT>2.0.CO;2. Hanft, W., and A. L. Houston, 2018: An Observational and Modeling Study of Mesoscale Air Masses with High Theta-E. Mon. Wea. Rev., 146, 2503&ndash;2524, https://doi.org/10.1175/MWR-D-17-0389.1.Wexler Houston, A. L., R. J. Laurence III, T. W. Nichols, S. Waugh, B. Argrow, and C. L. Ziegler, 2016: Intercomparison of unmanned aircraft-borne and mobile mesonet atmospheric sensors. Journal of Atmospheric and Oceanic Technology. 33, 1569-1582, doi: 10.1175/JTECH-D-15-0178.1. Lowe, P. R., 1977: An Approximating Polynomial for the Computation of Saturation Vapor Pressure. J. Applied Meteorology, 16, 100&ndash;103. Richardson, S. J., S. E. Frederickson, F. V. Brock, and J. A. Brotzge, 1998: Combination temperature and relative humidity probes: Avoiding large air temperature errors and associated relative humidity errors. Preprints, 10th Symp. On Meteorological Observations and Instrumentation, Phoenix, AZ, Amer. Meteor. Soc., 278&ndash;283. Waugh, S., and S. E. Frederickson, 2010: An improved aspirated temperature system for mobile meteorological observations, especially in severe weather. 25th Conf. on Severe Local Storms, Denver, CO, Amer. Meteor. Soc., P5.2. [Available online at https://ams.confex.com/ams/25SLS/techprogram/paper_176205.htm.]

54 ENVIRONMENTAL SCIENCES↗

Containment seal

A containment seal seals a cable or tube to an opening accessing a containment vessel. The containment seal includes a lower body that attaches over the opening into the containment vessel. The cable or tube is inserted through a hole that extends axially through an upper body of the containment seal. Compression fittings are attached to the top and bottom ends of the upper body sealing the cable inside of the upper body. The cable sealed inside of the upper body in inserted through the lower body and into the opening accessing the containment vessel and a lower portion of the upper body is seated into the opening formed in the lower body. A retaining device compresses the upper body down against the lower body forming a seal between the upper body and lower body.

42 ENGINEERING↗

Deformable closure mechanism

A deformable closure mechanism for an aperture that may include an aperture seal that has a seal seat between an internal support structure and an external support structure. A barrier structure may be configured to resealably close the aperture, and have a central membrane and a barrier sealed that is inflatable in order to engage the barrier structure with the aperture seal.

Doggett, William R.↗

Micromobility Integrated Transit and Infrastructure for Efficiency (MITIE)

Nearly omnipresent in many cities of all sizes across the United States, micromobility vehicles-e-scooters, manual bicycles, e-bicycles, and larger seated electric scooters-are notably missing from SMART Mobility research. This project aims to expand the spectrum of modes currently being researched within SMART Mobility by exploring micromobility as an important tool toward meeting energy-efficient mobility goals. It expands on findings from SMART Mobility 1.0 that revealed preferences to reduce transportation-related expenses through use of a network of mobility-as-a-service (MaaS) and other shared mobility options, and builds on findings from a 2019 Vehicle Technology Analysis Program (VTAP) funded micromobility project conducted by our team. We will explore multiple facets of micromobility, including behavior and decision-making, the integration of micromobility within transportation infrastructure, energy estimates, and operations. Guiding research questions include: (1) What are the potential energy savings from low, medium, and high market penetration of micromobility (in passenger, multimodal, and freight domains)? (2) Which scenarios for micromobility use and related enablement of increased public transit use should be modeled/considered in the SMART 2.0 Workflow? (3) To what degree can micromobility supplement/complement transit system operations? (4) What are people's preferences towards micromobility? How do preferences vary across various sociodemographic segments? How can this knowledge inform operations? (5) What are optimal strategies to attain high user adoption and shift users toward more energy-efficient mode choices in terms of micromobility operation? How do these strategies affect energy savings, person-miles traveled, lifecycle energy use, and adoption rates? These questions will be addressed through applied research in five project emphasis areas: (1) Energy estimates of micromobility for Workflow scenarios: Expand and refine previous micromobility work to augment the Workflow approaches to modeling urban travel. (2) Multimodal connection with transit: Utilizing Mobility-Energy Productivity (MEP) tools to evaluate multimodal travel patterns enabled by micromobility, including assessing how to reduce barriers of inequity of access to mobility options and destinations. (3) Mode choice, induced demand, and infrastructure: Understanding the mode shift induced through micromobility to inform energy impact analysis. (4) Energy optimization of micromobility operations: Identification of micromobility operations parameters and development of operations scenarios to better understand present-day micromobility operations for integration into the Workflow, in partnership with BEAM and POLARIS modeling teams. (5) Micro-freight: Characterize the current state of micro-freight activities, including energy effects and geospatial analyses, to inform Workflow.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Micromobility Integrated Transit and Infrastructure for Efficiency (MITIE)

Nearly omnipresent in many cities of all sizes across the United States, micromobility vehicles-e-scooters, manual bicycles, e-bicycles, and larger seated electric scooters-are notably missing from SMART Mobility research. This project aims to expand the spectrum of modes currently being researched within SMART Mobility by exploring micromobility as an important tool toward meeting energy-efficient mobility goals. It expands on findings from SMART Mobility 1.0 that revealed preferences to reduce transportation-related expenses through use of a network of mobility-as-a-service (MaaS) and other shared mobility options, and builds on findings from a 2019 Vehicle Technology Analysis Program (VTAP) funded micromobility project conducted by our team. We will explore multiple facets of micromobility, including behavior and decision-making, the integration of micromobility within transportation infrastructure, energy estimates, and operations. Guiding research questions include: 1) what are the potential energy savings from low, medium, and high market penetration of micromobility (in passenger, multimodal, and freight domains)? 2) which scenarios for micromobility use and related enablement of increased public transit use should be modeled/considered in the SMART 2.0 Workflow? 3) to what degree can micromobility supplement/complement transit system operations? 4) what are people's preferences towards micromobility? How do preferences vary across various sociodemographic segments? How can this knowledge inform operations? 5) what are optimal strategies to attain high user adoption and shift users toward more energy-efficient mode choices in terms of micromobility operation? How do these strategies affect energy savings, person-miles traveled, lifecycle energy use, and adoption rates? These questions will be addressed through applied research in five project emphasis areas: 1) energy estimates of micromobility for Workflow scenarios: Expand and refine previous micromobility work to augment the Workflow approaches to modeling urban travel; 2) multimodal connection with transit: Utilizing Mobility-Energy Productivity (MEP) tools to evaluate multimodal travel patterns enabled by micromobility, including assessing how to reduce barriers of inequity of access to mobility options and destinations; 3) mode choice, induced demand, and infrastructure: Understanding the mode shift induced through micromobility to inform energy impact analysis; 4) energy optimization of micromobility operations: Identification of micromobility operations parameters and development of operations scenarios to better understand present-day micromobility operations for integration into the Workflow, in partnership with BEAM and POLARIS modeling teams; 5) micro-freight: Characterize the current state of micro-freight activities, including energy effects and geospatial analyses, to inform Workflow.

ADVANCED PROPULSION SYSTEMS↗

Fuel injector with duct assembly

Methods and systems are provided for a fuel injector of an internal combustion engine. In one example, a fuel injector includes a body having a flange shaped to seat within a shoulder of a passage of a cylinder head. The shoulder is positioned at an inner side of the cylinder head such that the fuel injector is coupled to the cylinder head at the inner side by the flange.

Kurtz, Eric↗

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Developing Microalgae-Based Non-Isocyanate Polyurethane Foam Materials

Polyurethane is a versatile material with a wide range of applications in the production of foam products such as car seats, mattresses, footwear, insulation foam, and more. The traditional process for producing polyurethane foam involves the fast reaction of isocyanate with water, which generates CO2 as a blowing agent. However, the use of isocyanate has raised concerns due to its potential for causing allergic reactions and aspiration symptoms. This has led to increased regulation of isocyanate, leading to a growing interest in developing alternatives. Non-isocyanate polyurethane (NIPU) has emerged as a promising alternative to traditional toxic PU production. The most promising approach for producing NIPU is the aminolysis of cyclic carbonate with diamine. The NIPU produced through this process has a polyhydroxyurethane structure, which is similar to traditional PU chemistry. We have demonstrated that microalgal oil is a favored feedstock, as it can provide high reactivity for industrial applications. However, the NIPU production process does not generate gas, and a blowing agent is required to achieve the desired foam structure. One of the challenges in producing NIPU foam is to match the bubble formation and curing rates. We have developed a novel approach to producing NIPU foam that utilizes carbamate as a bifunctional blowing and crosslinking agent. We have used vegetable oil and microalgal oil as feedstocks to produce various NIPU for characterization. The development of microalgal NIPU provides an exciting opportunity for reducing the environmental impact of foam production and improving the safety of the materials used in the production process. The production of value-added NIPU foam can also drive down the cost of microalgal biorefinery, advancing the commercialization of microalgal biofuel.

algae↗

Use of Captured CO2 for Production of Sustainable Polyurethane Foams in Automotive Applications

Captured CO2 has been investigated as a feedstock for the production of polyurethane (PU) foams for automotive applications. Previous work has shown successful incorporation of CO2 into polyols via three distinct reaction pathways. These CO2-derived polyols, as well as several commercially available polyols with varying CO2 content, were used to produce PU foams for automotive seating and NVH (noise, vibration, and harshness) applications. Foam formulations were optimized to maximize sustainable content while maintaining manufacturability constraints and performance requirements for each end use application. PU foams were first formulated at lab scale to confirm free rise and molded foam properties, then scaled up to pilot and industrial scales to evaluate production manufacturing feasibility. Finally, CO2-derived foams were used to produce molded components for end use product validation. Life cycle assessment (LCA) was used to quantify the environmental impact of using captured CO2 and bio-renewable content into polyols and PU foams through the metrics of global warming potential and embodied energy. Tradeoffs among environmental impacts, energy usage, manufacturability, and PU foam performance from the incorporation of CO2 and bio-renewable content will be discussed.

Lee, Ellen [Ford Motor Company]↗

Co-treating flue gas desulfurized effluent and produced water enables novel waste management and recovery of critical minerals

Herein this study reports a novel approach of resource recovery from co-managing two geographically co-located and chemically complementary wastewaters using a pilot-scale treatment process. Designed to treat flue gas desulfurized (FGD) effluent from combustion powerplants and produced water (PW) from energy industries, the process consists of soda-ash softening, nanofiltration (NF), and reverse osmosis (RO). Recovered products are barite, calcite, and low-salinity water. Using field-collected waters, the results show that softening at pH 8.5 produces calcite (yield: 30 kg/m 3 treated water), a chemical used as SO ₂(g) scrubbers. NF treatment under an applied pressure of 3.5 MPa yields a permeate stream laden with monovalent ions (water recovery 60%) and a concentrate stream with a sulfate concentration 1.8 times of the feedwater concentration. Mixing the NF concentrate and PW at a volumetric ratio of 1.0 precipitates a high-density barite material (4.1 g/cm 3 , yield: ~7.5 kg/m 3 mixture) – a critical mineral commonly used as a weighting agent in drilling. The RO treatment recovers >64% water as the permeate, which can be readily used as cooling make-up water at the powerplants. The RO concentrate stream can be further processed in a thermal evaporative system for additional water recovery and brine production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗