Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity profiles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Regularized iterative weighted filtered backprojection for helical cone-beam CT

Contemporary reconstruction methods employed for clinical helical cone-beam computed tomography (CT) are analytical (noniterative) but mathematically nonexact, i.e., the reconstructed image contains so called cone-beam artifacts, especially for higher cone angles. Besides cone artifacts, these methods also suffer from windmill artifacts: alternating dark and bright regions creating spiral-like patterns occurring in the vicinity of high z-direction derivatives. In this article, the authors examine the possibility to suppress cone and windmill artifacts by means of iterative application of nonexact three-dimensional filtered backprojection, where the analytical part of the reconstruction brings about accelerated convergence. Specifically, they base their investigations on the weighted filtered backprojection method [Stierstorfer et al., Phys. Med. Biol. 49, 2209-2218 (2004)]. Enhancement of high frequencies and amplification of noise is a common but unwanted side effect in many acceleration attempts. They have employed linear regularization to avoid these effects and to improve the convergence properties of the iterative scheme. Artifacts and noise, as well as spatial resolution in terms of modulation transfer functions and slice sensitivity profiles have been measured. The results show that for cone angles up to {+-}2.78 deg., cone artifacts are suppressed and windmill artifacts are alleviated within three iterations. Furthermore, regularization parameters controlling spatial resolution can be tuned so that image quality in terms of spatial resolution and noise is preserved. Simulations with higher number of iterations and long objects (exceeding the measured region) verify that the size of the reconstructible region is not reduced, and that the regularization greatly improves the convergence properties of the iterative scheme. Taking these results into account, and the possibilities to extend the proposed method with more accurate modeling of the acquisition process, the authors believe that iterative improvement with non-exact methods is a promising technique for medical CT applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of Whisper Statistics for Criticality Safety Code Validation

Whisper is computational software designed to assist with validation studies with the Monte Carlo particle transport package MCNP. Historical approaches rely on expert based judgment to select benchmarks while Whisper uses sensitivity/uncertainty (S/U) methods to select relevant benchmarks to a particular application model. Whisper will also derive a calculational margin and margin of subcriticality (MOS) that may be used to generate an upper subcritical limit (USL) for a particular application model. Whisper finds benchmark experiments whose isotope sensitivity profiles align best with the MCNP model in question, and assign a correlation coefficient ('ck' in Whisper parlance) to each selected benchmark as a measure of how closely those profiles agree. When ck values are high, there is less uncertainty between model and benchmarks and a higher USL is possible, relative to cases when ck values are low. The default Whisper settings recommends a 100,000 particles per cycle run for 500 active cycles, resulting in 50 M active neutron histories per application run. This is computationally intensive and may not be necessary to produce accurate results. A Whisper statistical study was done varying the neutron histories per cycle from 10,000 to the default 100,000. A lower number of neutron histories will allow Whisper to be used on low memory systems such as laptops. The intent of this paper is to present the changes in the Whisper results as the number of neutrons histories run is varied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparisons between a priori Uncertainty Quantification and Calculation/Measurement Discrepancies Applied to the MERCI UO{sub 2} Fuel Rod Decay Heat Experiment

In 2008, an UO{sub 2} fuel rod was irradiated up to ∼ 3.5 GWd/tHL in the CEA/Saclay research reactor Osiris through the MERCI experiment. Some rod's pellets were analysed. Experimental results were obtained: - fuel rod decay heat measurement by calorimetry (cooling times from 27 minutes to 42 days), - evaluation of the amounts of some nuclei (U, Pu, Cs, Nd...) by isotopic dilution mass spectrometry, - nuclide activities. Comparison of type (C - M)/M where C is the calculated decay heat and M the experimentally measured decay heat was reported in reference. Neutronics flux was computed by CEA TRIPOLI-4 Monte-Carlo or APOLLO2 deterministic transport code system. Irradiation and cooling phases were simulated with CEA DARWIN/PEPIN2 code system. Good agreements were globally shown between numerical simulation results and experimental measurements on total decay heat. Uncertainty propagation in this previous work was established from Rebah's studies. These last years, within the framework of supports to its industrial partners EDF and Areva, the CEA/DEN has implemented two different approaches to propagate nuclear data uncertainties to depletion code outputs. A direct forward deterministic perturbation method using sensitivity profiles was implemented in the French industrial depletion code system DARWIN/PEPIN2. Meanwhile, a propagation based on Monte Carlo correlated sampling was achieved using the CEA uncertainty platform URANIE and the new generation depletion code MENDEL. Both methods will be described in this article. Uncertainties on nuclear data (independent fission yields, multigroup microscopic cross sections, radioactive decay constants, radioactive decay branching ratio and radioactive decay energies) are propagated to decay heat and isotopic concentrations. To match MERCI first study, flux computation is realized by APOLLO2. Furthermore, uncertainty quantification (UQ) is re-evaluated by both DARWIN/PEPIN2 and MENDEL codes. It is an important stage in the process of validating both depletion codes with their respective data library. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The effect of averaging adjacent planes for artifact reduction in matrix inversion tomosynthesis

Purpose: Matrix inversion tomosynthesis (MITS) uses linear systems theory and knowledge of the imaging geometry to remove tomographic blur that is present in conventional backprojection tomosynthesis reconstructions, leaving in-plane detail rendered clearly. The use of partial-pixel interpolation during the backprojection process introduces imprecision in the MITS modeling of tomographic blur, and creates low-contrast artifacts in some MITS planes. This paper examines the use of MITS slabs, created by averaging several adjacent MITS planes, as a method for suppressing partial-pixel artifacts. Methods: Human chest tomosynthesis projection data, acquired as part of an IRB-approved pilot study, were used to generate MITS planes, three-plane MITS slabs (MITSa3), five-plane MITS slabs (MITSa5), and seven-plane MITS slabs (MITSa7). These were qualitatively examined for partial-pixel artifacts and the visibility of normal and abnormal anatomy. Additionally, small (5 mm) subtle pulmonary nodules were simulated and digitally superimposed upon human chest tomosynthesis projection images, and their visibility was qualitatively assessed in the different reconstruction techniques. Simulated images of a thin wire were used to generate modulation transfer function (MTF) and slice-sensitivity profile curves for the different MITS and MITS slab techniques, and these were examined for indications of partial-pixel artifacts and frequency response uniformity. Finally, mean-subtracted, exposure-normalized noise power spectra (ENNPS) estimates were computed and compared for MITS and MITS slab reconstructions, generated from 10 sets of tomosynthesis projection data of an acrylic slab. The simulated in-plane MTF response of each technique was also combined with the square root of the ENNPS estimate to yield stochastic signal-to-noise ratio (SNR) information about the different reconstruction techniques. Results: For scan angles of 20 Degree-Sign and 5 mm plane separation, seven MITS planes must be averaged to sufficiently remove partial-pixel artifacts. MITSa7 does appear to subtly reduce the contrast of high-frequency 'edge' information, but the removal of partial-pixel artifacts makes the appearance of low-contrast, fine-detail anatomy even more conspicuous in MITSa7 slices. MITSa7 also appears to render simulated subtle 5 mm pulmonary nodules with greater visibility than MITS alone, in both the open lung and regions overlying the mediastinum. Finally, the MITSa7 technique reduces stochastic image variance, though the in-plane stochastic SNR (for very thin objects which do not span multiple MITS planes) is only improved at spatial frequencies between 0.05 and 0.20 cycles/mm. Conclusions: The MITSa7 method is an improvement over traditional single-plane MITS for thoracic imaging and the pulmonary nodule detection task, and thus the authors plan to use the MITSa7 approach for all future MITS research at the authors' institution.

60 APPLIED LIFE SCIENCES↗

A second‐generation virtual‐pinhole PET device for enhancing contrast recovery and improving lesion detectability of a whole‐body PET/CT scanner

Purpose We have developed a second‐generation virtual‐pinhole (VP) positron emission tomography (PET) device that can position a flat‐panel PET detector around a patient's body using a robotic arm to enhance the contrast recovery coefficient (CRC) and detectability of lesions in any region‐of‐interest using a whole‐body PET/computed tomography (CT) scanner. Methods We constructed a flat‐panel VP‐PET device using 32 high‐resolution detectors, each containing a 4 4 MPPC array and 16 16 LYSO crystals of 1.0 1.0 3.0 mm 3 each. The flat‐panel detectors can be positioned around a patient's body anywhere in the imaging field‐of‐view (FOV) of a Siemens Biograph 40 PET/CT scanner by a robotic arm. New hardware, firmware and software have been developed to support the additional detector signals without compromising a scanner's native functions. We stepped a 22 Na point source across the axial FOV of the scanner to measure the sensitivity profile of the VP‐PET device. We also recorded the coincidence events measured by the scanner detectors and by the VP‐PET detectors when imaging phantoms of different sizes. To assess the improvement in the CRC of small lesions, we imaged an elliptical torso phantom measuring 316 228 162 mm 3 that contains spherical tumors with diameters ranging from 3.3 to 11.4 mm with and without the VP‐PET device. Images were reconstructed using a list mode Maximum‐Likelihood Estimation‐Maximization algorithm implemented on multiple graphics processing units (GPUs) to support the unconventional geometries enabled by a VP‐PET system. The mean and standard deviation of the CRC were calculated for tumors of different sizes. Monte Carlo simulation was also conducted to image clusters of lesions in a torso phantom using a PET/CT scanner alone or the same scanner equipped with VP‐PET devices. Receiver operating characteristic (ROC) curves were analyzed for three system configurations to evaluate the improvement in lesion detectability by the VP‐PET device over the native PET/CT scanner. Results The repeatability in positioning the flat‐panel detectors using a robotic arm is better than 0.15 mm in all three directions. Experimental results show that the average CRC of 3.3, 4.3, and 6.0 mm diameter tumors was 0.82%, 2.90%, and 5.25%, respectively, when measured by the native scanner. The corresponding CRC was 2.73%, 6.21% and 10.13% when imaged by the VP‐PET insert device with the flat‐panel detector under the torso phantom. These values may be further improved to 4.31%, 9.65% and 18.01% by a future dual‐panel VP‐PET insert device if DOI detectors are employed to triple its detector efficiency. Monte Carlo simulation results show that the tumor detectability can be improved by a VP‐PET device that has a single flat‐panel detector. The improvement is greater if the VP‐PET device employs a dual‐panel design. Conclusions We have developed a prototype flat‐panel VP‐PET device and integrated it with a clinical PET/CT scanner. It significantly enhances the contrast of lesions, especially for those that are borderline detectable by the native scanner, within regions‐of‐interest specified by users. Simulation demonstrated the enhancement in lesion detectability with the VP‐PET device. This technology may become a cost‐effective solution for organ‐specific imaging tasks.

Jiang, Jianyong↗

Enhancing nuclear data validation analysis by using machine learning

In this work, we demonstrate how machine learning (ML) techniques can be used as an auxiliary tool for nuclear data validation analysis. The output of the ML analysis can inform evaluators and validators on the quality, or lack thereof, of specific nuclear data and benchmark experiments with respect to simulating these experimental benchmark values. To this end, measured and simulated effective neutron multiplication factors, k eff , of 875 selected ICSBEP critical assemblies and the latter's sensitivities with respect to nuclear data as well as benchmarks' features (e.g., material nuclide, core geometry) are used as input for a random forest (RF) regression model. The RF is used to encode the complex inter-dependencies between thousands of nuclear data features (i.e., sensitivity profiles and aspects describing the measurements) and 875 simulated and experimental k eff values in order to understand what nuclear data features are most informative for predicting bias. The complexity of relationships and high-dimensional space is difficult-to-impossible to search fully using simply expert judgment. As a first proof-of-concept—step, it is demonstrated that this technique is able to correctly trace large discrepancies between simulated and experimental k eff back to fabricated shortcomings in nuclear data that were perturbed to simulated k eff values. In a second, real-case scenario, step, the RF algorithm is used to validate the ENDF/B-VIII.0 library in comparison to ENDF/B-VII.1 nuclear data. One case is showcased where the chosen ML algorithms highlighted nuclear data (the 19 F(n,inl) cross section from 0.4–0.9 MeV) that are shown to be problematic by comparing them to associated differential experimental data and nuclear data from other libraries. In addition to that, it is shown that the RF results point towards poor benchmark experiments and associated underestimated uncertainties (e.g., the PU-SOL-THERM-028 series). However, using the RF algorithm for validating nuclear data with respect to k eff is currently limited to pinpointing groups of questionable nuclear data due to the inherent correlations between features introduced by the nuclear data themselves and how k eff is simulated. Due to this, we recommend that the ML methods presented be used to augment—rather than replace—the expert knowledge of evaluators and validators.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Outcomes of WPEC SG47 on "Use of Shielding Integral Benchmark Archive and Database for Nuclear Data Validation"

The Working Party on International Nuclear Data Evaluation Co-operation Subgroup 47 (WPECSG47) entitled "Use of Shielding Integral Benchmark Archive and Database for Nuclear Data Validation" was organised from 2019 and 2022 with the objectives to promote more systematic and wider use of shielding benchmark experiments in nuclear data (ND) and transport code validation and development, to provide feedback on the Shielding Integral Benchmark Archive and Database (SINBAD), and to promote its further development in coordination with the Expert Group on Physics of Reactor Systems (EGPRS). Altogether 9 meetings, the large majority (8) held remotely, were organised during the past 3 years to discuss the experience on the use of SINBAD, evaluation of new benchmarks and improvements to be contributed to the database which was severely neglected and lacking maintenance over the past ← 10+ years. Several proposals for new or updated benchmark evaluation were presented and discussed, such as FNG copper, LLNL pulsed spheres, CIAE iron sphere, KFK 1977 gamma measurements, Rez Fe sphere, ASPIS, ORNL Oxygen broomstick, TIARA and others. Complementing the database with new features was also discussed, for example providing the nuclear data sensitivity profiles more systematically would facilitate and better guide the use of data. Information on the geometry, (radiation source) and materials available in CAD format is expected to allow an easier and less error prone reference for computational model preparation and a potential input to CAD based workflows. Inputs for various transport codes and other benchmark data from participants have been shared via the NEA GitLab which could hopefully in the future evolve and form a bases for critically checked and validated benchmark data. Future development of SINBAD will be monitored by EGPRS and the newly created SINBAD Task Force.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using Machine Learning Methods to Predict Bias in Nuclear Criticality Safety

The manuscript provides a description of the application of machine-learning (ML) tools to the prediction of bias in criticality safety analysis. In particular, a set of over 1000 experiments included in the Whisper package were fed into a variety of ML algorithms (notably Random Forest and AdaBoost) implemented in SciKit-Learn using k-eigenvalue sensitivities (with and without energy dependence) for individual nuclides, and optionally, the simulated k eff as the training features. Ultimately, the ML model was used to predict the bias (k sim - k exp ). The results indicate that use of energy-integrated sensitivity profiles with k sim as training features led to the best predictions as quantified by root-mean square and mean absolute errors. In particular, the best-case estimates came from AdaBoost, with a mean absolute error of 0.00174, which is less than the mean experimental uncertainty of 0.00328 for the experiments included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reconstructing the three-dimensional latent image of extreme ultraviolet resists with resonant soft x-ray scattering

© 2019 Society of Photo-Optical Instrumentation Engineers (SPIE). Extreme ultraviolet (EUV) lithography is one of the most promising printing techniques for high-volume semiconductor manufacturing at the 14-nm half-pitch device node and beyond. However, key challenges around EUV photoresist materials, such as the exposure-dose sensitivity or the line-width roughness, continue to impede its full adoption into industrial nanofab facilities. Metrology tools are required to address these challenges by helping to assess the impact of the EUV materials' properties and processing conditions along different steps of the nanofabrication process. We apply the resonant soft x-ray scattering (RSoXS) technique to gain insights into the structure of patterned EUV resists before the development step takes place. By using energies around the carbon K-edge to take advantage of small differences in chemistry, the electronic density contrast between the exposed and unexposed regions of the resists could be enhanced in order to image the patterns with subnanometer precision. Critical-dimension grazing-incidence small-angle x-ray scattering is then performed at energies where the contrast is maximized, enabling the reconstruction of the three-dimensional shape of the latent image. We demonstrate the potential of RSoXS to provide a high-resolution height-sensitive profile of patterned EUV resists, which will help in quantifying the evolution of critical features, such as the line-edge roughness, at a key step of the nanofabrication process.

Freychet, Guillaume↗

Effect of nonlinear three-dimensional optimized reconstruction algorithm filter on image quality and radiation dose: Validation on phantoms

A new technique called the nonlinear three-dimensional optimized reconstruction algorithm filter (3D ORA filter) is currently used to improve CT image quality and reduce radiation dose. This technical note describes the comparison of image noise, slice sensitivity profile (SSP), contrast-to-noise ratio, and modulation transfer function (MTF) on phantom images processed with and without the 3D ORA filter, and the effect of the 3D ORA filter on CT images at a reduced dose. For CT head scans the noise reduction was up to 54% with typical bone reconstruction algorithms (H70) and a 0.6 mm slice thickness; for liver CT scans the noise reduction was up to 30% with typical high-resolution reconstruction algorithms (B70) and a 0.6 mm slice thickness. MTF and SSP did not change significantly with the application of 3D ORA filtering (P>0.05), whereas noise was reduced (P<0.05). The low contrast detectability and MTF of images obtained at a reduced dose and filtered by the 3D ORA were equivalent to those of standard dose CT images; there was no significant difference in image noise of scans taken at a reduced dose, filtered using 3D ORA and standard dose CT (P>0.05). The 3D ORA filter shows good potential for reducing image noise without affecting image quality attributes such as sharpness. By applying this approach, the same image quality can be achieved whilst gaining a marked dose reduction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and performance evaluation of an experimental fine pitch detector multislice CT scanner

The authors have developed an experimental fine pitch detector multislice CT scanner with an ultrasmall focal spot x-ray tube and a high-density matrix detector through current CT technology. The latitudinal size of the x-ray tube focal spot was 0.4 mm. The detector dimension was 1824 channels (azimuthal direction)x32 rows (longitudinal direction) at row width of 0.3125 mm, in which a thinner reflected separator surrounds each detector cell coupled with a large active area photodiode. They were mounted on a commercial 64-slice CT scanner gantry while the scan field of view (50 cm) and gantry rotation speed (0.35 s) can be maintained. The experimental CT scanner demonstrated the spatial resolution of 0.21-0.22 mm (23.8-22.7 lp/cm) with the acrylic slit phantom and in-plane 50%-MTF 9.0 lp/cm and 10%-MTF 22.0 lp/cm. In the longitudinal direction, it demonstrated the spatial resolution of 0.24 mm with the high-resolution insert of the CATPHAN phantom and 0.34 mm as the full width at half maximum of the slice sensitivity profile. In low-contrast detectability, 3 mm at 0.3% was visualized at the CTDI{sub vol} of 47.2 mGy. Two types of 2.75 mm diameter vessel phantoms with in-stent stenosis at 25%, 50%, and 75% stair steps were scanned, and the reconstructed images can clearly resolve the stenosis at each case. The experimental CT scanner provides high-resolution imaging while maintaining low-contrast detectability, demonstrating the potentiality for clinical applications demanding high spatial resolution, such as imaging of inner ear, lung, and bone, or low-contrast detectability, such as imaging of coronary artery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dual-source spiral CT with pitch up to 3.2 and 75 ms temporal resolution: Image reconstruction and assessment of image quality

Purpose: To present the theory for image reconstruction of a high-pitch, high-temporal-resolution spiral scan mode for dual-source CT (DSCT) and evaluate its image quality and dose. Methods: With the use of two x-ray sources and two data acquisition systems, spiral CT exams having a nominal temporal resolution per image of up to one-quarter of the gantry rotation time can be acquired using pitch values up to 3.2. The scan field of view (SFOV) for this mode, however, is limited to the SFOV of the second detector as a maximum, depending on the pitch. Spatial and low contrast resolution, image uniformity and noise, CT number accuracy and linearity, and radiation dose were assessed using the ACR CT accreditation phantom, a 30 cm diameter cylindrical water phantom or a 32 cm diameter cylindrical PMMA CTDI phantom. Slice sensitivity profiles (SSPs) were measured for different nominal slice thicknesses, and an anthropomorphic phantom was used to assess image artifacts. Results were compared between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2. In addition, image quality and temporal resolution of an ECG-triggered version of the DSCT high-pitch spiral scan mode were evaluated with a moving coronary artery phantom, and radiation dose was assessed in comparison with other existing cardiac scan techniques. Results: No significant differences in quantitative measures of image quality were found between single-source scans at pitch=1.0 and dual-source scans at pitch=3.2 for spatial and low contrast resolution, CT number accuracy and linearity, SSPs, image uniformity, and noise. The pitch value (1.6{<=}pitch{<=}3.2) had only a minor impact on radiation dose and image noise when the effective tube current time product (mA s/pitch) was kept constant. However, while not severe, artifacts were found to be more prevalent for the dual-source pitch=3.2 scan mode when structures varied markedly along the z axis, particularly for head scans. Images of the moving coronary artery phantom acquired with the ECG-triggered high-pitch scan mode were visually free from motion artifacts at heart rates of 60 and 70 bpm. However, image quality started to deteriorate for higher heart rates. At equivalent image quality, the ECG-triggered high-pitch scan mode demonstrated lower radiation dose than other cardiac scan techniques on the same DSCT equipment (25% and 60% dose reduction compared to ECG-triggered sequential step-and-shoot and ECG-gated spiral with x-ray pulsing). Conclusions: A high-pitch (up to pitch=3.2), high-temporal-resolution (up to 75 ms) dual-source CT scan mode produced equivalent image quality relative to single-source scans using a more typical pitch value (pitch=1.0). The resultant reduction in the overall acquisition time may offer clinical advantage for cardiovascular, trauma, and pediatric CT applications. In addition, ECG-triggered high-pitch scanning may be useful as an alternative to ECG-triggered sequential scanning for patients with low to moderate heart rates up to 70 bpm, with the potential to scan the heart within one heart beat at reduced radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical model based iterative reconstruction (MBIR) in clinical CT systems. Part II. Experimental assessment of spatial resolution performance

Purpose: Statistical model based iterative reconstruction (MBIR) methods have been introduced to clinical CT systems and are being used in some clinical diagnostic applications. The purpose of this paper is to experimentally assess the unique spatial resolution characteristics of this nonlinear reconstruction method and identify its potential impact on the detectabilities and the associated radiation dose levels for specific imaging tasks. Methods: The thoracic section of a pediatric phantom was repeatedly scanned 50 or 100 times using a 64-slice clinical CT scanner at four different dose levels [CTDI{sub vol} =4, 8, 12, 16 (mGy)]. Both filtered backprojection (FBP) and MBIR (Veo{sup ®}, GE Healthcare, Waukesha, WI) were used for image reconstruction and results were compared with one another. Eight test objects in the phantom with contrast levels ranging from 13 to 1710 HU were used to assess spatial resolution. The axial spatial resolution was quantified with the point spread function (PSF), while the z resolution was quantified with the slice sensitivity profile. Both were measured locally on the test objects and in the image domain. The dependence of spatial resolution on contrast and dose levels was studied. The study also features a systematic investigation of the potential trade-off between spatial resolution and locally defined noise and their joint impact on the overall image quality, which was quantified by the image domain-based channelized Hotelling observer (CHO) detectability index d′. Results: (1) The axial spatial resolution of MBIR depends on both radiation dose level and image contrast level, whereas it is supposedly independent of these two factors in FBP. The axial spatial resolution of MBIR always improved with an increasing radiation dose level and/or contrast level. (2) The axial spatial resolution of MBIR became equivalent to that of FBP at some transitional contrast level, above which MBIR demonstrated superior spatial resolution than FBP (and vice versa); the value of this transitional contrast highly depended on the dose level. (3) The PSFs of MBIR could be approximated as Gaussian functions with reasonably good accuracy. (4) Thez resolution of MBIR showed similar contrast and dose dependence. (5) Noise standard deviation assessed on the edges of objects demonstrated a trade-off with spatial resolution in MBIR. (5) When both spatial resolution and image noise were considered using the CHO analysis, MBIR led to significant improvement in the overall CT image quality for both high and low contrast detection tasks at both standard and low dose levels. Conclusions: Due to the intrinsic nonlinearity of the MBIR method, many well-known CT spatial resolution and noise properties have been modified. In particular, dose dependence and contrast dependence have been introduced to the spatial resolution of CT images by MBIR. The method has also introduced some novel noise-resolution trade-off not seen in traditional CT images. While the benefits of MBIR regarding the overall image quality, as demonstrated in this work, are significant, the optimal use of this method in clinical practice demands a thorough understanding of its unique physical characteristics.

60 APPLIED LIFE SCIENCES↗

Selected Uses of TSUNAMI in Critical Experiment Design and Analysis

Validation in criticality safety is performed by comparing the results of critical experiments with the calculated results from models of the experiments using the computational method to be validated. Laboratory critical experiments are controlled systems that achieve a k eff of approximately 1 and enable investigation of the parameters at which such a critical condition is achieved. For the critical experiments used in a validation to capture the biases of the materials and neutron energy spectra of interest, those materials must be included in the experiment such that they influence k eff or another observable parameter with statistical significance. This paper discusses the use of sensitivity uncertainty (S/U) methods to develop critical experiments for various purposes. S/U techniques are useful for understanding the underlying components of nuclear data which affect the k eff or another parameter of a given configuration. S/U calculations are most commonly used to compare existing experiments to applications of interest; however, S/U techniques can also be used to identify, optimize, or assess features of proposed experiments so that they can better test specific portions of nuclear data or match an application of interest. The S/U techniques discussed here are from the TSUNAMI code system. The two primary codes discussed in this work are TSUNAMI-3D, which implements the KENO criticality code to calculate the sensitivity of k eff to nuclear data, and TSAR, which calculates the sensitivity of a reactivity difference between two configurations based on their TSUNAMI-3D generated sensitivity profiles. The methods used in these tools are discussed in more detail in the SCALE manual. This paper is one of a series on the development and use of TSUNAMI tools. The other papers address development of TSUNAMI methods and a review of TSUNAMI applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using Machine Learning to Predict MCNP Bias

For many real-world applications in radiation transport where simulations are compared to experimental measurements, like in nuclear criticality safety, the bias (simulated - experimental k eff ) in the calculation is an extremely important quantity used for code validation. The objective of this project is to accurately predict the bias of MCNP6 [1] criticality calculations using machine learning (ML) algorithms, with the intention of creating a tool that can complement the current nuclear criticality safety methods. In the latest release of MCNP6, the Whisper tool is available for criticality safety analysts and includes a large catalogue of experimental benchmarks, sensitivity profiles, and nuclear data covariance matrices. This data, coming from 1100+ benchmark cases, is used in this study of ML algorithms for criticality safety bias predictions.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Investigating Region-wise Sensitivities for Nuclear Criticality Safety Validation

Whisper is a criticality safety statistical analysis package that uses the sensitivity profile data developed by MCNP6 for a given application and the covariance files for the nuclear data to determine a baseline Upper-Subcritical-Limit (USL) for a given application [1]. Whisper is designed to give a quantifiable basis for the selection of criticality benchmarks used to determine the appropriate calculational margin.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Nuclear Data Adjustment with Whisper for Criticality Safety Applications [Slides]

Nuclear data adjustment is used by Whisper to compute residual nuclear data uncertainties within a full suite of benchmarks; in order to do so, a complete set of nuclear data covariances, benchmarks and k-effective sensitivity profiles (for both benchmarks and applications) is required. For applications that are similar to the full benchmark suite, the residual uncertainties add a small margin to the overall USL calculation. For applications that are dissimilar to the full benchmark suite, the residual uncertainties add a reasonable margin to the overall USL calculation (more conservative). This methodology helps to overcome any issues in the released covariance libraries where nuclear data uncertainties appear to be too large.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗