Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor, radiation, Detection Material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Preconcentrating Minicolumn Sensors for Trace Environmental Monitoring

Preconcentrating minicolumn sensors represent an effective approach to achieve a substantial preconcentration factor within a sensing device, enabling very low detection limits as is required for environmental sensing. A selectively sorbent phase collects and concentrates analyte molecules as sample liquid is pumped through the column, ultimately equilibrating the entire sorbent phase with the analyte concentration in the sample. At equilibration, the amount on the column will be proportional to the analyte concentration when working at trace concentrations. We have demonstrated radiometric detection for the detection of radionuclides with this sensor, incorporating scintillating material in the column with the sorbent phase. The pertechnetate form of 99-technetium can be sensed using a mixed column bed containing anion exchange resin and scintillating plastic beads, collecting scintillation light with a pair of photomultiplier (PMT) tubes external to the transparent column body. For hexavalent chromium, we can also collect anions with anion exchange resin. In this case, optical fibers are coupled to the column body to measure the optical absorbance as a function of the amount of hexavalent chromium captured by the column. Both sensors can detect their respective analytes to levels below water standards.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation and Nuclear Materials Detection Research and Development at ORNL

Research and development is underway to improve radiation and nuclear detection capabilities. This research and development in radiation and nuclear detection includes areas such as advanced materials, applied research and engineering for designing and fabricating customized detection equipment, and theoretical modeling and computational support. Oak Ridge National Laboratory (ORNL) has a distinctive set of detector materials fabrication and characterization capabilities and recently created a Center for Radiation Detection Materials and Systems. Applied research and engineering efforts have led to the development of improved detectors for specific applications including safeguards, treaty monitoring, and science experiments. All sizes, types, and capabilities of detector systems have been addressed from miniature to man-portable and from neutrons to gamma radiation. Dedicated test beds, in-house and in the field, have been established to analyze, characterize, and improve detection systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid metal organic scintillator materials system and particle detector

We describe the preparation and characterization of two zinc hybrid luminescent structures based on the flexible and emissive linker molecule, trans-(4-R,4'-R') stilbene, where R and R' are mono- or poly-coordinating groups, which retain their luminescence within these solid materials. For example, reaction of trans-4,4'-stilbenedicarboxylic acid and zinc nitrate in the solvent dimethylformamide (DMF) yielded a dense 2-D network featuring zinc in both octahedral and tetrahedral coordination environments connected by trans-stilbene links. Similar reaction in diethylformamide (DEF) at higher temperatures resulted in a porous, 3-D framework structure consisting of two interpenetrating cubic lattices, each featuring basic to zinc carboxylate vertices joined by trans-stilbene, analogous to the isoreticular MOF (IRMOF) series. We demonstrate that the optical properties of both embodiments correlate directly with the local ligand environments observed in the crystal structures. We further demonstrate that these materials produce high luminescent response to proton radiation and high radiation tolerance relative to prior scintillators. These features can be used to create sophisticated scintillating detection sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Passive Magnetoelastic Radiation Sensor

A passive gamma detection technology, consisting of a fielded sensor and a separate analysis system, is described. The sensor is a small cylinder, about 2.5 mm in diameter and 15 mm in length. It requires no onboard power sources or physical connections for power or data transfer, and retains its cumulative response to radiation. The sensor consists of an amorphous magnetoelastic wire held in a longitudinally-stressed state by a radiation-sensitive material. When the radiation-sensitive material is subjected to gamma radiation, it mechanically degrades, relaxing the stress on the wire and lowering the wire’s magnetic permeability. The changes in permeability are observed by switching the magnetic domains in the wire and measuring the reduction in the Faraday voltage as the stress is diminished. The analysis package is built around an excitation-detection coil set and can communicate wirelessly with the sensor through a metallic or nonmetallic barrier at distances up to about 25 mm. The sensor response is linear up to a dose of at least 7 kGy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of COTS Rad Detection Apps

Mobile applications are currently under distribution to smart phones utilizing the built-in charge coupled-device (CCD) camera as a radiation detector. The CCD detector has a very low but measurable gamma interaction cross section so the mechanism is feasible, especially for higher dose rate environments. Given that in a large release of radioactive material these ‘crowd sourced’ measurements will be put forth for consideration, a testing and evaluation of the accuracy and uncertainty of the Apps is a critical endeavor. Not only is the accuracy of the reported measurement of concern to the immediate user’s safety, a quantitative uncertainty is required for a government response such as the Federal Radiological Monitoring and Assessment Center (FRMAC) to accept the values for consideration in the determination of regions exceeding protective action guidelines. Already, prompted by the Fukushima nuclear material releases, several repositories of this crowd-sourced data have been created (http://japan.failedrobot.com, http://www.stubbytour.com/nuc/index_en.asp, and http://www.rdtn.org) although the question remains as to the reliability of measurements incorporated into these repositories. In cases of conflict between the real-time published crowd-sourced data and governmental protective actions prepared literature should be on-hand documenting why the difference, if any, exists. Four applications for iOS devices were obtained along with hardware to benchmark their performance. Gamma/X-Ray Detector by Stephan Hotto, Geiger Camera by Senscare, and RadioactivityCounter App by Hotray LTD are all the applications available for distribution within the US that utilize the CCD camera sensor for detection of radiation levels. The CellRad app under development by Idaho National Laboratory for the Android platform was evaluated. In addition, iRad Geiger with the associated hardware accessory was also benchmarked. Radiation fields were generated in a Cs-137 JL Shepherd Model 89 shielded calibration range. The accuracy of the exposure rate within the box calibrator is +/- 5% of the system settings and NIST traceable. This is the same calibration unit utilized for calibration of US DOE exposure rate meters. Measurements were performed from 0.2 to 40,000 mR/hr. Included in the following sections are discussions on each of the evaluated applications and their performance in reporting radiation field measurements. Unfortunately the applications do not provide a readily identifiable quality of the measurement in order to produce error bars or even out of range conditions. In general all the CCD based applications had issues detecting consistent measurements in radiation fields less than 5 mR/hr. This is most likely attributable to the electronic noise level on the CCD’s becoming comparable to the signal level due to the ionizing radiation photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monitoring/Verification using DMS: TATP Example

Field-rugged and field-programmable differential mobility spectrometry (DMS) networks provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. CBE sensor motes used in conjunction with automated fast gas chromatography with DMS detection (GC/DMS) verification instrumentation integrated into situational operations-management systems can be readily deployed and optimized for changing application scenarios. The feasibility of developing selective DMS motes for a “smart dust” sampling approach with guided, highly selective, fast GC/DMS verification analysis is a compelling approach to minimize or prevent the illegal use of explosives or chemical and biological materials. DMS is currently one of the foremost emerging technologies for field separation and detection of gas-phase chemical species. This is due to trace-level detection limits, high selectivity, and small size. Fast GC is the leading field analytical method for gas phase separation of chemical species in complex mixtures. Low-thermal-mass GC columns have led to compact, low-power field systems capable of complete analyses in 15–300 seconds. A collaborative effort optimized a handheld, fast GC/DMS, equipped with a non-rad ionization source, for peroxide-based explosive measurements.

47 OTHER INSTRUMENTATION↗

Gamma response study of radiation sensitive MOSFETs for their use as gamma radiation sensor

Continuous monitoring of gamma dose is important in various fields like radiation therapy, space-related research, nuclear energy programs and high energy physics experiment facilities. The present work is focused on utilization of radiation-sensitive Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs) to monitor gamma radiation doses. Static characterization of these detectors was performed to check their expected current-voltage relationship. Threshold voltage and transconductance per unit gate to source voltage (K factor) were calculated from the experimental data. The detector was exposed to gamma radiation in both, with and without gate bias voltage conditions, and change in threshold voltage was monitored at different gamma doses. The experimental data was fitted to obtain equation for dependence of threshold voltage on gamma dose. More than ten times increase in sensitivity was observed in biased condition (+3 V) compared to the unbiased case.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development and study the performance of PBA cladding modified fiber optic intrinsic biosensor for urea detection

The fabrication and study of a cladding modified fiber optic intrinsic urea biosensor based on evanescent wave absorbance has been presented. The sensor was prepared using cladding modification technique by removing a small portion of cladding of an optical fiber and modifying with an active cladding of porous polyaniline-boric acid (PBA) matrix to immobilize enzyme-urease through cross-linking via glutaraldehyde. The nature of as-synthesized and deposited PBA film on fiber optic sensing element was studied by ultraviolet-visible (UV-vis) spectroscopy and X-ray diffraction (XRD) analysis. The performance of the developed sensor was studied for different urea concentrations in solutions prepared in phosphate buffer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

EFFECTS OF TRITIUM GAS EXPOSURE ON ELECTRICALLY CONDUCTING POLYMERS

Effects of beta (tritium) and gamma irradiation on the surface electrical conductivity of two types of conducting polymer films are documented to determine their potential use as a sensing and surveillance device for the tritium facility. It was shown that surface conductivity was significantly reduced by irradiation with both gamma and tritium gas. In order to compare the results from the two radiation sources, an approximate dose equivalence was calculated. The materials were also sensitive to small radiation doses (<10{sup 5} rad), showing that there is a measurable response to relatively small total doses of tritium gas. Spectroscopy was also used to confirm the mechanism by which this sensing device would operate in order to calibrate this sensor for potential use. It was determined that one material (polyaniline) was very sensitive to oxidation while the other material (PEDOT-PSS) was not. However, polyaniline provided the best response as a sensing material, and it is suggested that an oxygen-impermeable, radiation-transparent coating be applied to this material for future device prototype fabrication. A great deal of interest has developed in recent years in the area of conducting polymers due to the high levels of conductivity that can be achieved, some comparable to that of metals [Gerard 2002]. Additionally, the desirable physical and chemical properties of a polymer are retained and can be exploited for various applications, including light emitting diodes (LED), anti-static packaging, electronic coatings, and sensors. The electron transfer mechanism is generally accepted as one of electron 'hopping' through delocalized electrons in the conjugated backbone, although other mechanisms have been proposed based on the type of polymer and dopant [Inzelt 2000, Gerard 2002]. The conducting polymer polyaniline (PANi) is of particular interest because there are extensive studies on the modulation of the conductivity by changing either the oxidation state of the main backbone chain, or by protonation of the imine groups [de Acevedo, 1999]. There are several types of radiation sensors commercially available, including ionization chambers, geiger counters, proportional counters, scintillators and solid state detectors. Each type has advantages, although many of these sensors require expensive electronics for signal amplification, are large and bulky, have limited battery life or require expensive materials for fabrication. A radiation sensor constructed of a polymeric material could be flexible, light, and the geometry designed to suit the application. Very simple and inexpensive electronics would be necessary to measure the change in conductivity with exposure to radiation and provide an alarm system when a set change of conductivity occurs in the sensor that corresponds to a predetermined radiation dose having been absorbed by the polymer. The advantages of using a polymeric sensor of this type rather than those currently in use are the flexibility of sensor geometry and relatively low cost. It is anticipated that these sensors can be made small enough for glovebox applications or have the ability to monitor the air tritium levels in places where a traditional monitor cannot be placed. There have been a few studies on the changes in conductivity of polyaniline specifically for radiation detection [de Acevedo, 1999; Lima Pacheco, 2003], but there have been no reports on the effects of tritium (beta radiation) on conducting polymers, such as polyaniline or polythiophene. The direct implementation of conducting polymers as radiation sensor materials has not yet been commercialized due to differing responses with total dose, dose rate, etc. Some have reported a large increase in the surface conductivity with radiation dose while others report a marked decrease in conductive properties; these differing observations may reflect the competing mechanisms of chain scission and cross-linking. However, it is clear that the radiation dose effects on conducting polymers must be fully understood before these materials can be used as sensing devices. This report presents the results of irradiations of two conductive polymers: polyaniline and polythiophene. Samples of doped polyaniline and polythiophene were coated onto polyester (polyethyleneterephalate, PET) substrates and were exposed to both tritium gas (beta irradiation) and {sup 60}Co gamma irradiation. The samples were subsequently characterized after various total doses. Infrared spectroscopy was utilized to characterize the gamma-exposed samples post-irradiation. Although the sources of radiation are different in kind (charged particle versus photon) and their energies differ, there will be great value in using noncontaminating gamma irradiation to model the effects of tritium beta radiation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of Additives: Gamma-Ray Sensors Based on Ionizing Organic Nanocomposites

We have developed ionizing organic-based composites which have demonstrated great promise for radiation sensing. Nickel oxide has been proven as an active material for detecting high energy radiation. The oxidation state of unusual oxides such as nickel oxide in nanocomposites of ionizing organics changes much faster than thin film or bulk, and hence increases the sensitivity for radiation sensing. The resistivity of the oxide composite increases following sequential irradiation processes because of the decrease in holes' concentration. In this paper, we will present the effect of additional oxidizing agent on the morphology, processing and sensing of gamma-rays by oxides - urea based nanocomposites. It was observed that addition of MnO2 decreases the sensitivity. However, it recovers to original properties after irradiation much faster than undoped composites.

Vishall Dayal↗

Radiation hardness of three-dimensional polycrystalline diamond detectors

The three-dimensional concept in particle detection is based on the fabrication of columnar electrodes perpendicular to the surface of a solid state radiation sensor. It permits to improve the radiation resistance characteristics of a material by lowering the necessary bias voltage and shortening the charge carrier path inside the material. If applied to a long-recognized exceptionally radiation-hard material like diamond, this concept promises to pave the way to the realization of detectors of unprecedented performances. We fabricated conventional and three-dimensional polycrystalline diamond detectors, and tested them before and after neutron damage up to 1.2 ×10{sup 16 }cm{sup −2}, 1 MeV-equivalent neutron fluence. We found that the signal collected by the three-dimensional detectors is up to three times higher than that of the conventional planar ones, at the highest neutron damage ever experimented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anisotropy in Thermal Conductivity of Ga2O3 under Irradiation: Ab-initio Investigations

Ga2O3 is a wide-bandgap semiconducting material known for its high breakdown electric field and thermal stability. Its various crystalline forms have shown great potential in power electronics, optoelectronics, and high-temperature applications. Specifically, ß-Ga2O3 has been recognized for its suitability in neutron and gamma radiation detection, making it ideal for sensor and detector applications [1]. Notably, ß-Ga2O3 exhibits anisotropic thermal conductivity, meaning that the magnitude of thermal conductivity varies with the crystallographic direction [2]. Under neutron irradiation, Ga2O3 undergoes a significant phenomenon, resulting in the formation of Helium bubbles within its crystalline matrix. The presence of Helium in Ga2O3 has been found to influence the material's anisotropic thermal conductivity. In this study, the objectives were twofold: firstly, to employ Density Functional Theory (DFT) to determine the most probable sites of Helium occupation in ß-Ga2O3, and secondly, to investigate the anisotropic variation in thermal conductivity when Helium is present in the crystalline matrix of ß-Ga2O3. These ab-initio DFT studies provide crucial insights into understanding the behavior of Helium in Ga2O3 and its impact on thermal conductivity, which can contribute to further advancements in sensor and detector applications based on this wide-bandgap semiconductor.

36 MATERIALS SCIENCE↗

ORNL Trusted Corridors Project: Watts Bar Dam Inland Waterway Project

Radiation has existed everywhere in the environment since the Earth's formation - in rocks, soil, water, and plants. The mining and processing of naturally occurring radioactive materials for use in medicine, power generation, consumer products, and industry inevitably generate emissions and waste. Radiological measuring devices have been used by industry for years to measure for radiation in undesired locations or simply identify radioactive materials. Since the terrorist attacks on the United States on 9-11-01 these radiation measuring devices have proliferated in many places in our nation's commerce system. DOE, TVA, the Army Corps and ORNL collaborated to test the usefulness of these devices in our nation's waterway system on this project. The purpose of the Watts Bar Dam ORNL Trusted Corridors project was to investigate the security, safety and enforcement needs of local, state and federal government entities for state-of-the-art sensor monitoring in regards to illegal cargo including utilization of the existing infrastructure. TVA's inland waterways lock system is a recognized and accepted infrastructure by the commercial carrier industry. Safety Monitoring activities included tow boat operators, commercial barges and vessels, recreational watercraft and their cargo, identification of unsafe vessels and carriers, and, monitoring of domestic and foreign commercial vessels and cargo identification. Safety Enforcement activities included cargo safety, tracking, identification of hazardous materials, waterway safety regulations, and hazardous materials regulations. Homeland Security and Law Enforcement Applications included Radiological Dispersive Devices (RDD) identification, identification of unsafe or illicit transport of hazardous materials including chemicals and radiological materials, and screening for shipments of illicit drugs. In the Fall of 2005 the SensorNet funding for the project expired. After several unsuccessful attempts to find a Federal sponsor to continue with the project, the Watts Bar Dam Project was canceled and the Exploranium radiation monitors were removed from the doors of Watts Bar Dam in early 2006. The DHS Domestic Nuclear Detection Office decided to proceed with a Pilot building on the ORNL work performed at the TN and SC weigh stations in the highway sector of the Trusted Corridors project and eventually expanded it to other southern states under the name of Southeastern Corridor Pilot Project (SETCP). Many of the Phase I goals were achieved however real-world test data of private watercraft and barges was never obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study on Application of Distributed Network of Sensors with List Mode for NMAC Literature Review

Nuclear material accounting and control (NMAC) for nuclear security detects, deters, and resolves questions related to unauthorized removal (i.e. theft) or misuse of nuclear material. NMAC also serves as a key insider threat mitigation measure and aids in recovery of nuclear material that is missing. Effective nuclear security depends on NMAC for timely and accurate information about nuclear material types, quantities, and locations. Bulk nuclear material processing facilities, however, present unique challenges for effective NMAC due to the presence of large quantities of material in-process and the accumulation of residual material holdup within process equipment. These holdup accumulations can obscure accurate physical inventory taking and complicate efforts to resolve NMAC irregularities at the facility level. Bulk material monitoring systems often rely on material balance calculations and indirect measurement techniques, which may mask protracted theft of smaller amounts of nuclear material. These monitoring limitations have generated increased interest in continuous monitoring technologies, including distributed non-destructive assay (NDA) sensor networks capable of providing real-time or near-real-time measurement of material movement and accumulation within bulk processing environments. Recent advancements in distributed networks of NDA radiation detectors and sensing technologies provide an opportunity to address these limitations. Although such distributed sensor networks have been implemented in select facilities for IAEA Safeguards applications, their potential for supporting NMAC functions specifically tailored to nuclear security objectives remains largely unexplored. Furthermore, emerging list-mode data acquisition technologies have reached high technology readiness levels, enabling time-correlated detection of nuclear events across multiple temporal scales. These capabilities provide enhanced opportunities for accurate holdup measurement, continuous process monitoring, and improved detection of material theft or misuse over time. The increasing global expansion of civil nuclear power and development of related bulk material processing facilities, including those supporting high-assay low-enriched uranium (HALEU) and other advanced reactor fuel fabrication, further increases the need for advanced measurement and monitoring strategies for NMAC.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Infrared light-assisted preparation of Ag nanoparticles-reduced graphene oxide nanocomposites for non-enzymatic H{sub 2}O{sub 2} sensing

Graphical abstract: An infrared light irradiation method has been developed for preparation of AgNPs/rGO nanocomposites for electrochemical detection of H{sub 2}O{sub 2}. - Highlights: • AgNPs/rGO nanocomposites have been prepared by photochemical method. • AgNPs/rGO nanocomposites exhibit good sensing performances for detection of H{sub 2}O{sub 2}. • The present work provides a simple and green method for preparation of rGO-based materials. - Abstract: A green method has been developed for preparation of Ag nanoparticles/reduced graphene oxide (AgNPs/rGO) nanocomposites by infrared light irradiation. The characterizations indicate the successful preparation of AgNPs/rGO nanocomposites. Most importantly, AgNPs/rGO nanocomposites exhibit excellent electrocatalytic activity for reduction of H{sub 2}O{sub 2}, leading to a high-performance non-enzymatic H{sub 2}O{sub 2} sensor with linear detection range and detection limit about 0.1 mM to 140 mM (r = 0.9896) and 3.0 μM, respectively.

36 MATERIALS SCIENCE↗

Proliferation Detection via Acoustic Monitoring of Pyroprocessing Equipment and Related Systems

In support of nuclear safeguards and nonproliferation, this effort is leveraging acoustic and seismic sensors to advance detection of pyroprocessing activities. Pyroprocessing, or electrochemical processing, is a method of separating irradiated nuclear fuel into its actinide and fission product components, enabling the reuse of fuel materials and reducing the radiotoxicity of the remaining waste. Verification and accountability in the process poses several challenges because of the high radiation environment and the presence of material holdup through the facility. Irregular or unaccounted-for equipment operation can signify diversion or misuse of critical materials. Acoustic and seismic sensors offer the capability to identify periods of equipment operation and help verify adherence to accountancy records.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SNM Movement Detection/Radiation Sensors and Advanced Materials Portfolio Review, CdMnTe (CMT) Gamma Ray Detectors

The project goals are: (1) Develop CMT radiation detectors - Demonstrate feasibility (Phase 1 is complete) and Improve material properties and device performance; (2) This project will lead to novel radiation detectors - high detection efficiency, high energy-resolution, ambient-temperature operation, and low production cost; and (3) Such detectors are needed in areas of nonproliferation and national security for detection of SNM. Research highlights are: (1) We achieved our Phase-I goal - Demonstration of CMT detector performance approaching that of CZT detectors; (2) Demonstrated that In-doped CMT is much closer to its anticipated performance as radiation detectors than other alternative materials, TlBr and HgI{sub 2} - Large crystal volumes, 10{sup 10}{Omega}{center_dot}cm, 3 x 10{sup -3}cm{sup 2}/V, and stable response; and (3) Conducted material and device characterization experiments - Detectors: I-V, {mu}{sub e}, ({mu}{tau}){sub e}, internal E fields, energy spectra, and high-resolution x-ray response mapping data and Materials - DLTS, TCT, PL, EPDs, XRD, PCD and IR transmission.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Nanowire-based detector

Systems, articles, and methods are provided related to nanowire-based detectors, which can be used for light detection in, for example, single-photon detectors. In one aspect, a variety of detectors are provided, for example one including an electrically superconductive nanowire or nanowires constructed and arranged to interact with photons to produce a detectable signal. In another aspect, fabrication methods are provided, including techniques to precisely reproduce patterns in subsequently formed layers of material using a relatively small number of fabrication steps. By precisely reproducing patterns in multiple material layers, one can form electrically insulating materials and electrically conductive materials in shapes such that incoming photons are redirected toward a nearby electrically superconductive materials (e.g., electrically superconductive nanowire(s)). For example, one or more resonance structures (e.g., comprising an electrically insulating material), which can trap electromagnetic radiation within its boundaries, can be positioned proximate the nanowire(s). The resonance structure can include, at its boundaries, electrically conductive material positioned proximate the electrically superconductive nanowire such that light that would otherwise be transmitted through the sensor is redirected toward the nanowire(s) and detected. In addition, electrically conductive material can be positioned proximate the electrically superconductive nanowire (e.g. at the aperture of the resonant structure), such that light is directed by scattering from this structure into the nanowire.

47 OTHER INSTRUMENTATION↗