Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensor Utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of a Compact Lidar Sensor for Terrain Relative Navigation and Terrain Hazard Avoidance

A Lidar sensor utilizing linear-mode flash lidar technology and a novel Super-Resolution technique has been developed for providing Terrain Relative Navigation and Hazard Avoidance capabilities onboard landing vehicles. Processing algorithms for precision navigation and safe landing location identification take advantage of the uniform fixed pixels property of generated high resolution Digital Elevation Maps to achieve high reliability operation in near real-time. This paper describes the results of drone and helicopter flight tests of a breadboard system, explains the design and capabilities of a recently built compact prototype unit, and proposes a concepts of operation for future landing missions.

3-D Imaging↗

Evaluation of the Paratrend Multi-Analyte Sensor for Potential Utilization in Long-Duration Automated Cell Culture Monitoring

BACKGROUND: Compact and automated sensors are desired for assessing the health of cell cultures in biotechnology experiments. While several single-analyte sensors exist to measure culture health, a multi-analyte sensor would simplify the cell culture system. One such multi-analyte sensor, the Paratrend 7 manufactured by Diametrics Medical, consists of three optical fibers for measuring pH, dissolved carbon dioxide (pCO(2)), dissolved oxygen (pO(2)), and a thermocouple to measure temperature. The sensor bundle was designed for intra-vascular measurements in clinical settings, and can be used in bioreactors operated both on the ground and in NASA's Space Shuttle and International Space Station (ISS) experiments. METHODS: A Paratrend 7 sensor was placed at the outlet of a bioreactor inoculated with BHK-21 (baby hamster kidney) cells. The pH, pCO(2), pO(2), and temperature data were transferred continuously to an external computer. Cell culture medium, manually extracted from the bioreactor through a sampling port, was also assayed using a bench top blood gas analyzer (BGA). RESULTS: Two Paratrend 7 sensors were used over a single cell culture experiment (64 days). When compared to the manually obtained BGA samples, the sensor had good agreement for pH, pCO(2), and pO(2) with bias (and precision) 0.005(0.024), 8.0 mmHg (4.4 mmHg), and 11 mmHg (17 mmHg), respectively for the first two sensors. A third Paratrend sensor (operated for 141 days) had similar agreement (0.02+/-0.15 for pH, -4+/-8 mm Hg for pCO(2), and 24+/-18 mmHg for pO(2)). CONCLUSION: The resulting biases and precisions are com- parable to Paratrend sensor clinical results. Although the pO(2) differences may be acceptable for clinically relevant measurement ranges, the O(2) sensor in this bundle may not be reliable enough for the ranges of pO(2) in these cell culture studies without periodic calibration.

Validation Studies↗

The utility of Thematic Mapper sensor characteristics for surface mine monitoring

The employment of Landsat Multispectral Scanner (MSS) data for surface coal mine inventory and inspection applications has been extensively investigated. However, in spite of encouraging research results, MSS data have not gained wide acceptance for surface mine monitoring operations. This situation is partly related to MSS spatial resolution (80 m), which is considered insufficient for detailed surface mine inspection. The Thematic Mapper (TM) employed on the Landsat-4 and 5 satellites provides an improved resolution (30 m) and other refinements which are expected to enhance the usefulness of TM data relative to MSS data. The present paper reports research which was conducted to assess the usefulness of actual TM data and to quantitatively evaluate the contribution of individual sensor characteristics to data utility for surface mine monitoring. The obtained results demonstrate that the TM spatial resolution can be of immediate benefit for certain applications such as surface mine monitoring.

Irons, J. R.↗

SSME leak detection feasibility investigation by utilization of infrared sensor technology

This investigation examined the potential of using state-of-the-art technology of infrared (IR) thermal imaging systems combined with computer, digital image processing and expert systems for Space Shuttle Main Engines (SSME) propellant path peak detection as an early warning system of imminent engine failure. A low-cost, laboratory experiment was devised and an experimental approach was established. The system was installed, checked out, and data were successfully acquired demonstrating the proof-of-concept. The conclusion from this investigation is that both numerical and experimental results indicate that the leak detection by using infrared sensor technology proved to be feasible for a rocket engine health monitoring system.

Shohadaee, Ahmad A.↗

Studies of Minerals, Organic and Biogenic Materials through Time-Resolved Raman Spectroscopy

A compact remote Raman spectroscopy system was developed at NASA Langley Research center and was previously demonstrated for its ability to identify chemical composition of various rocks and minerals. In this study, the Raman sensor was utilized to perform time-resolved Raman studies of various samples such as minerals and rocks, Azalea leaves and a few fossil samples. The Raman sensor utilizes a pulsed 532 nm Nd:YAG laser as excitation source, a 4-inch telescope to collect the Raman-scattered signal from a sample several meters away, a spectrograph equipped with a holographic grating, and a gated intensified CCD (ICCD) camera system. Time resolved Raman measurements were carried out by varying the gate delay with fixed short gate width of the ICCD camera, allowing measurement of both Raman signals and fluorescence signals. Rocks and mineral samples were characterized including marble, which contain CaCO3. Analysis of the results reveals the short (approx.10-13 s) lifetime of the Raman process, and shows that Raman spectra of some mineral samples contain fluorescence emission due to organic impurities. Also analyzed were a green (pristine) and a yellow (decayed) sample of Gardenia leaves. It was observed that the fluorescence signals from the green and yellow leaf samples showed stronger signals compared to the Raman lines. Moreover, it was also observed that the fluorescence of the green leaf was more intense and had a shorter lifetime than that of the yellow leaf. For the fossil samples, Raman shifted lines could not be observed due the presence of very strong short-lived fluorescence.

Garcia, Christopher S.↗

The 1979 Southeastern Virginia Urban Plume Study. Volume 1: Description of experiments and selected aircraft data

The Southeastern Virginia Urban Plume Study (SEV-UPS) utilizes remote sensors and satellite platforms to monitor the Earth's environment and resources. SEV-UPS focuses on the application of specific remote sensors to the monitoring and study of specific air quality problems. The 1979 SEV-UPS field program was conducted with specific objectives: (1) to provide correlative data to evaluate the Laser Absorption spectrometer ozone remote sensors; (2) to demonstrate the utility of the sensor for the study of urban ozone problems; (3) to provide additional insights into air quality phenomena occuring in Southeastern Virginia; and (4) to compare measurement results of various in situ measurement platforms. The field program included monitoring from 12 surface stations, 4 aircraft, 2 tethered balloons, 2 radiosonde release sites, and numerous surface meteorological observation sites. The aircraft monitored 03, NO, NOX, Bscat, temperature, and dewpoint temperature.

Gregory, G. L.↗

Electro-optical liquid depth sensor

Transducer utilizes absorptive properties of water to determine variations in depth without disturbing liquid. Instrument is inexpensive, simple, and small and thus can be used in lieu of direct graduated scale readout or capacitive, ultrasonic, resistive or inducive sensors when these are impractical because of complexity or cost.

Heppner, D. B.↗

Design and evaluation of an optical fine-pointing control system for telescopes utilizing a digital star sensor

One of the most significant problems associated with the development of large orbiting astronomical telescopes is that of maintaining the very precise pointing accuracy required. A proposed solution to this problem utilizes dual-level pointing control. The primary control system maintains the telescope structure attitude stabilized within the field of view to the desired accuracy. In order to demonstrate the feasibility of optically stabilizing the star images to the desired accuracy a regulating system has been designed and evaluated. The control system utilizes a digital star sensor and an optical star image motion compensator, both of which have been developed for this application. These components have been analyzed mathematically, analytical models have been developed, and hardware has been built and tested.

Ostroff, A. J.↗

Simulation study of traffic-sensor noise effects on utilization of traffic situation display for self-spacing task

The effect of traffic sensor noise on the ability of a pilot to perform an intrail spacing task was determined. The tests were conducted in a fixed base cockpit simulator configured as a current generation transport aircraft, with an electronic traffic display provided in the weather radarscope location. The true positions of the traffic were perturbed in both relative range and azimuth by random errors to simulate traffic sensor noise associated with an onboard sensor. The evaluation task involved simulated instrument approaches into a terminal area while maintaining self separation on a lead aircraft. Separation performance data and pilot subjective ratings and comments were obtained. The results of the separation data indicate that displayed traffic position errors, having standard deviation values up to 0.3-n.mi. range and 8 deg azimuth, had negligible effect on the spacing performance achieved by the pilots. Speed profiles of the lead aircraft, display of the lead aircraft groundspeed, and individual pilot techniques were found to significantly affect the mean spacing performance.

Williams, D. H.↗

Integrated-Optic Oxygen Sensors

Compact optical oxygen sensors with self-calibration capabilities are undergoing development. A sensor of this type features a single-chip, integrated-optic design implemented by photolithographic fabrication of optical waveguides in a photosensitive porous glass. The porosity serves as both a matrix for retention of an oxygen-sensitive fluorescent indicator chemical and a medium for diffusion of oxygen to the chemical from the ambient air to be monitored. Each sensor includes at least one such waveguide exposed to the atmosphere and at least one covered with metal for isolation from the atmosphere. The covered one serves as a reference channel. In operation, the concentration of oxygen is deduced from the intensity and lifetime of the fluorescence in the exposed channel, with the help of calibration data acquired via the reference channel. Because the sensory chemical is placed directly in and throughout the cross section of the light path, approximately 99 percent of the light in the waveguide is available for interaction with the chemical, in contradistinction to only about 1 percent of the light in an optical sensor that utilizes evanescentwave coupling. Hence, a sensor of this type is significantly more sensitive.

Mendoza, Edgar A.↗

Investigation of a para-ortho hydrogen reactor for application to spacecraft sensor cooling

The utilization of solid hydrogen in space for sensor and instrument cooling is a very efficient technique for long term cooling or for cooling at high heat rates. The solid hydrogen can provide temperatures as low as 7 to 8 K to instruments. Vapor cooling is utilized to reduce parasitic heat inputs to the 7 to 8 K stage and is effective in providing intermediate cooling for instrument components operating at higher temperatures. The use of solid hydrogen in place of helium may lead to weight reductions as large as a factor of ten and an attendent reduction in system volume. The results of an investigation of a catalytic reactor for use with a solid hydrogen cooling system is presented. Trade studies were performed on several configurations of reactor to meet the requirements of high reactor efficiency with low pressure drop. Results for the selected reactor design are presented for both liquid hydrogen systems operating at near atmospheric pressure and the solid hydrogen cooler operating as low as 1 torr.

Nast, T. C.↗

Investigation of a stall deterrent system utilizing an acoustic stall sensor

A simple rugged acoustic stall sensor which has an output proportional to angle of attack near wing stall has been evaluated on a Cessna 319 aircraft. A sensor position has been found on the wing where the sensor output is only slightly affected by engine power level, yaw angle, flap position and wing roughness. The NASA LRC General Aviation Simulator has been used to evaluate the acoustic sensor output as a control signal for active stall deterrent systems. It has been found that a simple control algorithm is sufficient for stall deterrence.

Bennett, A. G.↗

Mock Truss-Braced Wing Loads Calibration Research Utilizing Fiber-Optic Sensors

In support of the National Aeronautics and Space Administration Advanced Air Transonic Transport Truss-Braced Wing structural research, the Armstrong Flight Research Center Flight Loads Laboratory is performing pathfinder tests on a small, scaled test article (dubbed the mock Truss-Braced Wing) to study the application of a loads calibration on a truss-braced wing structure. The addition of a truss to the wing structure, as opposed to a purely cantilever beam setup, changes the strain-gage-based loads calibration techniques. In a truss-braced configuration, the internal shear and moments, inboard of the truss-wing connection, are not directly representative of the external aerodynamic loading as is the case for a traditional cantilever configuration. A 3-axis load cell was used at the wing-to-strut interface to estimate the load sharing between the two structural members. Crosstalk within the 3-axis load cell is added to the measurement uncertainties of the calibration effort, and the results, including crosstalk uncertainties, are presented. The calibration tests presented in this report are used as a pathfinder for developing an understanding how to perform loads calibration on a truss-braced wing structural configuration. The use of distributed fiber-optic strain sensors is leveraged to provide a near-full-span strain profile along the leading and trailing edge of the wing structure for strain-based loads calibration.

Francisco Peña↗

Trace Oxygen Measurements of Asteroid Sample Storage Desiccators

The Astromaterials Curation facility at the NASA Johnson Space Center is currently curating more than 120 g of carbonaceous asteroid Bennu material as well as over 500 mg of asteroid Ryugu [1 and 2]. These astromaterials are stored in isolating desiccators and gloveboxes under a continuous purge of pure (<1 ppm O 2 ) gaseous nitrogen. The oxygen and moisture concentrations in our OSIRIS-REx sample processing gloveboxes are continuously monitored via integrated sensors; however, our sample storage desiccators lack integrated oxygen and humidity sensors. In previous studies, we used PreSens Fibox 4 trace oxygen meters and optochemical PSt9 spot sensors to measure the oxygen concentrations in candidate asteroid sample containers that had been sealed in nitrogen; we determined that Eagle stainless steel containers inhibit the ingress of external oxygen for several weeks [3]. This optochemical sensor technology allowed us to take precise, contactless measurements within a trace range of 0 to 200 ppmv O 2 . The effectiveness of the trace oxygen sensors in our container experiments inspired us to utilize them to assess the performance of our desiccators that previously lacked trace oxygen monitoring. In this study, our goal was to determine the quality of the nitrogen purge in the isolating desiccator under normal operating conditions by measuring the trace oxygen content. Utilizing optochemical sensor technology, we determined how long the oxygen concentration takes to reach an equilibrium in the desiccator; that is, determine the rate at which the oxygen diffusion into the desiccator equals the rate at which oxygen diffuses out of the desiccator via N2 purge. Additionally, we wanted to determine the oxygen concentration at this equilibrium, the state in which our desiccators are in during normal operating conditions. We tested a custom three chamber desiccator manufactured by Germfree using a PSt9 trace oxygen sensor spot that was mounted into a ¼” National Pipe Tapered (NPT) metal flow-through cell and attached it to the desiccator exhaust. The desiccator consists of top, middle, and bottom isolating chambers. The top chamber door was opened for several minutes to simulate a sample exchange, it was sealed, and then purged ~15 Standard Cubic Feet per Hour (SCFH). Oxygen measurements were automatically recorded via the Fibox 4 trace oxygen meter in 5-minute intervals over the course of a 24-hour period. Our results indicate the desiccator reached an equilibrium value of 10-15 ppm O 2 after ~5 hours (Fig. 1). This data allows us to explore standards for purging and exchange protocols that can be applied to similar types of desiccators in Hayabusa2, OSIRIS-REx, and for sample return collections. The assessment of the internal gaseous compositions of desiccators also allows us to share with the community the N 2 environment in which many of our asteroid samples and hardware are securely curated. Future measurements will include other nitrogen flow rates and measuring the trace oxygen concentration as a function of time for the levels of the previous commercial desiccator in which the Hayabusa2 sample collection was stored. We will also analyze how long the desiccators hold N2 after being disconnected from their N2 source, an extended measurement for sample security reassurance.

Curation↗

Census Cities Project and atlas of urban and regional change

The research design and imagery utilization for urban applications of remote sensing are reviewed, including the combined use of sensor and census data and aircraft and spacecraft sensor platforms. The related purposes of the Census Cities Project are elucidated: (1) to assess the role of remote sensors on high altitude platforms for comparative study of urban areas; (2) to detect changes in selected U.S. urban areas between the 1970 census and the time of launching of an earth-orbiting sensor platform prior to next census; (3) to test the satellite sensor platform utility to monitor urban change and serve as a control for sensor image interpretation; (4) to design an information system for incorporating graphic sensor data with census-type data gathered by traditional techniques; (5) to identify and to design user-oriented end-products or information services; and (6) to ascertain what organizational capability would be needed to provide such services on a continuing basis. A need to develop not only a spatial data information system, but also a methodology for detecting and interpreting change is implied.

Wray, J. R.↗