OpenFacadeControl: enabling integration of automated facades with other building systems

Automated facades are, for the most part, still considered as separate from other building systems throughout the design, installation, commissioning, operation, and maintenance cycle. This takes place despite the fact that their energy and comfort performance are deeply interlinked with the operation of lighting and HVAC systems. Over the last two decades, research has shown that there are significant advantages from operating facades as an integrated system with the rest of the building. Nevertheless, significant barriers prevent this type of integration becoming more common. One of them is the lack of a platform that is inexpensive to implement and that easily allows the practical implementation of integrated control algorithms across fenestration and other building systems, using a variety of communications protocols. This is particularly challenging when automated facades are installed in existing buildings, where interaction with legacy building systems that were installed over the past lifetime of the building can require a high degree of interoperability. OpenFacadeControl (OFC) is an open-source controls framework aimed at unified control of facades and other building systems, including the sharing of third-party sensor information. Through leveraging the Volttron controls platform, it allows the integration of systems and sensors that are manufactured by different companies and that use different communications protocols into an ensemble that functions as a single system. OFC is designed to enable integrated control algorithms of varying degrees of complexity, ranging from simple, heuristic controls to more sophisticated approaches like model-predictive control. Use of a research version to test advanced lighting and shading strategies in a full-scale experimental testbed has demonstrated the ease of deploying advanced control solutions using OpenFacadeControl. This paper presents the structure of OpenFacadeControl and a demonstration case showing the use of OFC in laboratory tests of advanced lighting and fenestration controls that coordinated motorized shades communicating via the BACnet building communications standard and lights communicating via internet-protocol-based application programming interface (API), based on the readings of a shared light level sensor communicating via a different API.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Correlating structural and photochemical heterogeneity in cyanobacteriochrome NpR6012g4

Phytochrome photoreceptors control plant growth, development, and the shade avoidance response that limits crop yield in high-density agricultural plantings. Cyanobacteriochromes (CBCRs) are distantly related photosensory proteins that control cyanobacterial metabolism and behavior in response to light. Photoreceptors in both families reversibly photoconvert between two photostates via photoisomerization of linear tetrapyrrole (bilin) chromophores. Spectroscopic and biochemical reprorts have demonstrated heterogeneity in both photostates, but the structural basis for such heterogeneity remains unclear. We discuss solution NMR structures for both photostates of the red/green CBCR NpR6012g4 from Nostoc punctiforme . In addition to identifying structural changes accompanying photoconversion, these structures reveal structural heterogeneity for residues Trp655 and Asp657 in the red-absorbing NpR6012g4 dark state, yielding two distinct environments for the phycocyanobilin chromophore. We use site-directed mutagenesis and fluorescence and absorbance spectroscopy to assign an orange-absorbing population in the NpR6012g4 dark state to the minority configuration for Asp657. This population does not undergo full, productive photoconversion, as shown by time-resolved spectroscopy and absorption spectroscopy at cryogenic temperature. Our research thus elucidate the spectral and photochemical consequences of structural heterogeneity in a member of the phytochrome superfamily, insights that should inform efforts to improve photochemical or fluorescence quantum yields in the phytochrome superfamily.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Instrumentation for Solar Resource Measurements and Forecasting: Cooperative Research and Development Final Report, CRADA Number CRD-09-349

Under this Agreement, NREL will work with Participant to improve the instrumentation and measurement systems available for measuring and monitoring solar radiation elements needed by the electric utilities and solar power system integrators to adequately characterize the spatial and temporal variations of the renewable energy resources. This work includes, but is not limited to, research and development for making cost effective radiometers, solar trackers, and related instrumentation for solar resource measurements and forecasting. Cooperative R&D is proposed in three areas: Improved radiometric systems for cost effective irradiance measurements (direct normal, global, diffuse and plane-of-array); evaluation of innovative disruptive technology approaches for deriving the constituent solar energy components utilizing new fast-response thermopile measurement technologies, coupled with innovative shading geometry and tracker motion control; and low-cost solutions for sky imaging needed for resource forecasting. This work will be conducted at NREL and Participant facilities.

14 SOLAR ENERGY↗

Applied photo interpretation for airbrush cartography

Lunar and planetary exploration has required the development of new techniques of cartographic portrayal. Conventional photo-interpretive methods employing size, shape, shadow, tone, pattern, and texture are applied to computer-processed satellite television images. Comparative judgements are affected by illumination, resolution, variations in surface coloration, and transmission or processing artifacts. The portrayal of tonal densities in a relief illustration is performed using a unique airbrush technique derived from hill-shading of contour maps. The control of tone and line quality is essential because the mid-gray to dark tone densities must be finalized prior to the addition of highlights to the drawing. This is done with an electric eraser until the drawing is completed. The drawing density is controlled with a reflectance-reading densitometer to meet certain density guidelines. The versatility of planetary photo-interpretive methods for airbrushed map portrayals is demonstrated by the application of these techniques to the synthesis of nonrelief data.

Inge, J. L.↗

The Roman Space Telescope Observatory Build, Test and Verification Status

The Nancy Grace Roman Space Telescope (“Roman”) was prioritized by the 2010 Decadal Survey in Astronomy and Astrophysics and is NASA’s next astrophysics flagship observatory. Launching no earlier than 2026, it will conduct several wide field and time domain surveys, as well as conduct an exoplanet census. Roman’s large field of view, agile survey capabilities, and excellent stability enable these objectives, yet present unique engineering and test challenges. The Roman Observatory comprises a Spacecraft and the Integrated Payload Assembly (IPA), the latter of which includes the Optical Telescope Assembly (OTA), the primary science Wide Field Instrument, a technology demonstration Coronagraph Instrument, and the Instrument Carrier, which meters the OTA to each instrument. The Spacecraft supports the IPA and includes the Bus, Solar Array Sun Shield, Outer Barrel Assembly, and Deployable Aperture Cover. It provides all required power, command handling, attitude control, communications, data storage, and stable thermal control functions as well as shading and straylight protection across the entire field of regard. This paper presents the Observatory as it begins integration and test, as well as describes key test and verification activities.

Infrared Missions↗

Evaluation of color in digital nuclear power plant control room displays

Human system interface design in industrial process control is guided by industry standards, human factors best practices, and domain-specific conventions, and often there is a conflict between one or more of the sources of design input for specific design elements. In the nuclear domain, one design element for which conflict arises is the use of color to represent equipment state. Here, this study evaluates the tradeoffs associated with using color in a process control display versus using white and shades of gray. The performance metrics were response time, accuracy, and eye movement metrics using a simplified experimental task and professional operators. Results revealed that adhering to color conventions in nuclear power yielded small advantages in simple tasks, but did not exist for more complex tasks. The results did not provide strong evidence for or against using a particular color scheme and revealed the need for further research on the use of color for commercial nuclear power plants and other process control industries.

99 GENERAL AND MISCELLANEOUS↗

Human-building interaction at work: Findings from an interdisciplinary cross-country survey in Italy

This study presents results from an interdisciplinary survey assessing contextual and behavioral factors driving occupants’ interaction with building and systems in offices located across three different Mediterranean climates in Turin (Northern), Perugia (Central), and Rende (Southern) Italy. The survey instrument is grounded in an interdisciplinary framework that bridges the gap between building physics and social science environments on the energy- and comfort-related human-building interaction in the workspace. Outcomes of the survey questionnaire provide insights into four key learning objectives: (1) individual occupant's motivational drivers regarding interaction with shared building environmental controls (such as adjustable thermostats, operable windows, blinds and shades, and artificial lighting), (2) group dynamics such as perceived social norms, attitudes, and intention to share controls, (3) occupant perception of the ease of use and knowledge of how to operate control systems, and (4) occupant-perceived comfort, satisfaction, and productivity. The study attempts to identify climatic, cultural, and socio-demographic influencing factors, as well as to establish the validity of the survey instrument and robustness of outcomes for future studies. Also, the paper aims at illustrating why and how social science insights can bring innovative knowledge into the adoption of building technologies in shared contexts, thus enhancing perceived environmental satisfaction and effectiveness of personal indoor climate control in office settings and impacting office workers’ productivity and reduced operational energy costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bistable Black Electrochromic Windows Based on the Reversible Metal Electrodeposition of Bi and Cu

Optically tunable windows based on reversible metal electrodeposition are an exciting alternative to static lighting control methods such as blinds and shades. In this Letter, we study reversible Bi/Cu electrodeposition on Pt-modified transparent conducting electrodes for electrochromic applications. Spectroelectrochemical measurements combined with scanning electron microscopy images indicate that the electrolytic Bi:Cu ratio drastically affects the electrode switching speed and electrodeposit morphology, which we propose is due to the galvanic displacement of Bi by Cu + . These findings allow us to construct 25 cm 2 black dynamic windows with reversibly tunable transmission at fast switching speeds. This rapid cycling can be maintained over 1000 cycles without degradation in contrast or uniformity. Lastly, the Bi–Cu windows consume no power to maintain either their transparency or opacity, making them promising candidates for energy-efficient devices. Their combination of fast switching, color neutrality, durable cycling, and dual-state resting stability make dynamic windows based on Bi–Cu reversible electrodeposition promising and competitive alternatives to traditional electrochromic materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy and Comfort Impacts of High Performance Facades in Office Buildings

Building facades have a major effect on energy use, occupant comfort, and well-being. Yet adoption of high-performance facades is often slowed by limited data and unclear cost benefits. To address this gap, Oak Ridge National Laboratory, in collaboration with the Facade Tectonics Institute, conducted whole-building energy simulations to evaluate fenestration technologies for small and medium office buildings across three weather locations: hot (Tampa, Florida, weather zone 2A), mixed (New York, New York, weather zone 4A), and cold (Rochester, Minnesota, weather zone 6A). The simulations included parametric variations in window-to-wall ratio (30%–70%), U-values (0.1–1 Btu/h∙ft 2 ∙°F), solar heat gain coefficients (0.2–0.8), and solar control strategies and devices (e.g., interior shades and switchable glazing). Performance metrics included annual cooling, heating, and total heating, ventilation and air-conditioning (HVAC) energy use intensity, as well as nonenergy factors such as useful daylight illuminance, glare frequency, and thermal comfort during typical office hours (8 a.m.–6 p.m.). Results indicate that cooling energy consumption is most sensitive to solar heat gain coefficient (SHGC) in hot weather, whereas heating energy consumption is strongly influenced by U-value in cold weather. Total HVAC reflects these trade-offs, showing up to 60% difference for a window in total HVAC energy use intensity between different combinations of U-value and SHGC. Daylight dimming generally reduces cooling loads but can increase heating demands in colder locations. Interior solar shades improve useful daylight and reduce discomfort glare, whereas switchable glazing delivers the largest cooling reductions in hot weather but may increase heating loads in winter by limiting passive solar gains. Thermal comfort improves with lower window-to-wall ratios and lower SHGC in hot locations and with lower U-values in cold locations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal control systems for low-temperature heat rejection on a lunar base

One of the important issues in the design of a lunar base is the thermal control system (TCS) used to reject low-temperature heat from the base. The TCS ensures that the base and the components inside are maintained within an acceptable temperature range. The temperature of the lunar surface peaks at 400 K during the 336-hour lunar day. Under these circumstances, direct dissipation of waste heat from the lunar base using passive radiators would be impractical. Thermal control systems based on thermal storage, shaded radiators, and heat pumps have been proposed. Based on proven technology, innovation, realistic complexity, reliability, and near-term applicability, a heat pump-based TCS was selected as a candidate for early missions. In this report, Rankine-cycle heat pumps and absorption heat pumps (ammonia water and lithium bromide-water) have been analyzed and optimized for a lunar base cooling load of 100 kW.

Sridhar, K. R.↗

Investigation of lunar base thermal control system options

Long duration human exploration missions to the Moon will require active thermal control systems which have not previously been used in space. The two technologies which are most promising for long term lunar base thermal control are heat pumps and radiator shades. Recent trade-off studies at the Johnson Space Center have focused development efforts on the most promising heat pump and radiator shade technologies. Since these technologies are in the early stages of development and many parameters used in the study are not well defined, a parametric study was done to test the sensitivity to each assumption. The primary comparison factor in these studies was the total mass system, with power requirements included in the form of a mass penalty for power. Heat pump technologies considered were thermally driven heat pumps such as metal hydride, complex compound, absorption and zeolite. Also considered were electrically driven Stirling and vapor compression heat pumps. Radiator shade concepts considered included step shaped, V-shaped and parabolic (or catenary) shades and ground covers. A further trade study compared the masses of heat pump and radiator shade systems.

Ewart, Michael K.↗

Simulation of complex glazing products; from optical data measurements to model based predictive controls

Complex glazing systems such as venetian blinds, fritted glass and woven shades require more detailed optical and thermal input data for their components than specular non light-redirecting glazing systems. Various methods for measuring these data sets are described in this paper. These data sets are used in multiple simulation tools to model the thermal and optical properties of complex glazing systems. The output from these tools can be used to generate simplified rating values or as an input to other simulation tools such as whole building annual energy programs, or lighting analysis tools. I also describe some of the challenges of creating a rating system for these products and which factors affect this rating. A potential future direction of simulation and building operations is model based predictive controls, where detailed computer models are run in real-time, receiving data for an actual building and providing control input to building elements such as shades.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Potential energy savings with exterior shades in large office buildings and the impact of discomfort glare

Exterior shades are highly efficient for reducing solar load in commercial buildings. Their impact on net energy use depends on the annual energy balance of heating, cooling, fan and lighting energy. This paper discusses the overall energy use intensity of various external shading systems for a prototypical large office building split into the different types of energy use and for different orientations and window sizes. Lighting energy was calculated for a constant lighting power as well as for dimmed lighting fixtures (daylighting control). In Section 3, slat angles and solar cut-off angles were varied for fixed exterior slat shading systems. While the most light-blocking shades performed best for the case without daylighting controls, the optimum cut-off angle with daylighting controls was found to be 30 deg for the office building prototype used in Chicago and Houston. For large window-to-wall (WWR) ratios, window related annual energy use could be reduced by at least 70 % without daylighting control and by a minimum of 86 % with daylighting control in average over all orientations. The occurrence of discomfort glare was is considered in Section 4 of the paper, which looks at the performance of commercially available exterior shading systems when an interior shade is used in addition to the exterior shade during hours when occupants would experience discomfort glare. Glare control impacts overall energy use intensity significantly for exterior shades with high transmittance, especially when daylighting controls are used. In these cases, exterior shades are only beneficial for window-to-wall areas ≥ 45% in the hot Houston climate. For smaller windows and in a heating/cooling climate like Chicago, exterior shades can increase energy consumption

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aircraft control position indicator

An aircraft control position indicator was provided that displayed the degree of deflection of the primary flight control surfaces and the manner in which the aircraft responded. The display included a vertical elevator dot/bar graph meter display for indication whether the aircraft will pitch up or down, a horizontal aileron dot/bar graph meter display for indicating whether the aircraft will roll to the left or to the right, and a horizontal dot/bar graph meter display for indicating whether the aircraft will turn left or right. The vertical and horizontal display or displays intersect to form an up/down, left/right type display. Internal electronic display driver means received signals from transducers measuring the control surface deflections and determined the position of the meter indicators on each dot/bar graph meter display. The device allows readability at a glance, easy visual perception in sunlight or shade, near-zero lag in displaying flight control position, and is not affected by gravitational or centrifugal forces.

Dennis, Dale V.↗

High Performance Building Facade Solutions - PIER Final Project Report

Building facades directly influence heating and cooling loads and indirectly influence lighting loads when daylighting is considered, and are therefore a major determinant of annual energy use and peak electric demand. Facades also significantly influence occupant comfort and satisfaction, making the design optimization challenge more complex than many other building systems.This work focused on addressing significant near-term opportunities to reduce energy use in California commercial building stock by a) targeting voluntary, design-based opportunities derived from the use of better design guidelines and tools, and b) developing and deploying more efficient glazings, shading systems, daylighting systems, facade systems and integrated controls. This two-year project, supported by the California Energy Commission PIER program and the US Department of Energy, initiated a collaborative effort between The Lawrence Berkeley National Laboratory (LBNL) and major stakeholders in the facades industry to develop, evaluate, and accelerate market deployment of emerging, high-performance, integrated facade solutions. The LBNL Windows Testbed Facility acted as the primary catalyst and mediator on both sides of the building industry supply-user business transaction by a) aiding component suppliers to create and optimize cost effective, integrated systems that work, and b) demonstrating and verifying to the owner, designer, and specifier community that these integrated systems reliably deliver required energy performance. An industry consortium was initiated amongst approximately seventy disparate stakeholders, who unlike the HVAC or lighting industry, has no single representative, multi-disciplinary body or organized means of communicating and collaborating. The consortium provided guidance on the project and more importantly, began to mutually work out and agree on the goals, criteria, and pathways needed to attain the ambitious net zero energy goals defined by California and the US.A collaborative test, monitoring, and reporting protocol was also formulated via the Windows Testbed Facility in collaboration with industry partners, transitioning industry to focus on the importance of expecting measured performance to consistently achieve design performance expectations. The facility enables accurate quantification of energy use, peak demand, and occupant comfort impacts of synergistic facade-lighting-HVAC systems on an apples-to-apples comparative basis and its data can be used to verify results from simulations. Emerging interior and exterior shading technologies were investigated as potential near-term, low-cost solutions with potential broad applicability in both new and retrofit construction. Commercially-available and prototype technologies were developed, tested, and evaluated. Full-scale, monitored field tests were conducted over solstice-to-solstice periods to thoroughly evaluate the technologies, uncover potential risks associated with an unknown, and quantify performance benefits. Exterior shading systems were found to yield net zero energy levels of performance in a sunny climate and significant reductions in summer peak demand. Automated interior shading systems were found to yield significant daylighting and comfort-related benefits.In support of an integrated design process, a PC-based commercial fenestration (COMFEN) software package, based on EnergyPlus, was developed that enables architects and engineers to quickly assess and compare the performance of innovative facade technologies in the early sketch or schematic design phase. This tool is publicly available for free and will continue to improve in terms of features and accuracy. Other work was conducted to develop simulation tools to model the performance of any arbitrary complex fenestration system such as common Venetian blinds, fabric roller shades as well as more exotic innovative facade systems such as optical louver systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Exploration Extravehicular Mobility Unit (xEMU) Helmet and Extravehicular Visor Assembly (EVVA) Chamber B Thermal Vacuum Testing Results

NASA’s Exploration Extravehicular Mobility Unit (xEMU) is the government reference next-generation spacesuit design and is engineered to protect astronauts from extreme lunar environmental temperatures. To evaluate the xEMU hardware thermal requirements, the xEMU Testing Team invented, designed, and executed a dual-suit, uncrewed thermal vacuum (TVAC) test at Johnson Space Center’s (JSC) Chamber B. This paper details the test methodology, hardware setup, and results from the xEMU helmet and extravehicular visor assembly (EVVA). Two helmets/EVVAs were tested simultaneously in Chamber B, with different thermal environments and EVVA configurations. For the helmet/EVVA on the Short xEMU (SxEMU) test article, five thermal profiles were tested during five simulated EVAs, with four different visor and shade configurations. For the helmet/EVVA on the second xEMU, eleven unique thermal profiles were tested including both cold and hot environmental cases over the course of five continuous days of testing, with a single visor and shade configuration. The radiative thermal environment was controlled through exposure to liquid-nitrogen shrouds on the chamber walls and through two separate heater cages surrounding each respective test article. The thermal effects of the Exploration Informatics (xINFO) lights and camera on the helmet/EVVA was also tested. Twenty-two temperature sensors were used to collect data in critical locations in the xEMU helmet/EVVA assembly. This paper will document the testing results and compare the test data against the xEMU helmet/EVVA and system-level thermal models for model validation.

xEMU↗

Adaptive smart simulator for characterization and MPPT construction of PV array

Partial shading conditions are among the most important problems in large photovoltaic array. Many works of literature are interested in modeling, control and optimization of photovoltaic conversion of solar energy under partial shading conditions, The aim of this study is to build a software simulator similar to hard simulator and to produce a shading pattern of the proposed photovoltaic array in order to use the delivered information to obtain an optimal configuration of the PV array and construct MPPT algorithm. Graphical user interfaces (Matlab GUI) are built using a developed script, this tool is easy to use, simple, and has a rapid of responsiveness, the simulator supports large array simulations that can be interfaced with MPPT and power electronic converters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance of Integrated Systems of Automated Roller Shade Systems and Daylight Responsive Dimming Systems

Daylight responsive dimming systems have been used in few buildings to date because they require improvements to improve reliability. The key underlying factor contributing to poor performance is the variability of the ratio of the photosensor signal to daylight workplane illuminance in accordance with sun position, sky condition, and fenestration condition. Therefore, this paper describes the integrated systems between automated roller shade systems and daylight responsive dimming systems with an improved closed-loop proportional control algorithm, and the relative performance of the integrated systems and single systems. The concept of the improved closed-loop proportional control algorithm for the integrated systems is to predict the varying correlation of photosensor signal to daylight workplane illuminance according to roller shade height and sky conditions for improvement of the system accuracy. In this study, the performance of the integrated systems with two improved closed-loop proportional control algorithms was compared with that of the current (modified) closed-loop proportional control algorithm. In the results, the average maintenance percentage and the average discrepancies of the target illuminance, as well as the average time under 90percent of target illuminance for the integrated systems significantly improved in comparison with the current closed-loop proportional control algorithm for daylight responsive dimming systems as a single system.