Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shielding Calculations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A database-informed approach to new plant shielding design

Document available in abstract form only, full text of document follows: To facilitate the definition and description of radiation dose rates in the numerous rooms and areas of a new nuclear power plant, a database approach was developed. This approach offers a number of benefits over more manual methods. A key benefit is that the selection of an appropriate shielding method to use in each area of the plant is greatly facilitated by virtue of the team's improved ability to grasp the significance of each of the individual sources that are candidates for making a significant contribution to the dose rate in each area. By understanding the level of relevant contribution - if any - of each of these candidate sources, an analyst is able to select a method that will define the contribution without becoming enmired in a model representing inappropriately high degrees of accuracy and modeling time. This database method, by allowing for an evolving understanding of dose rates and sources in the neighboring rooms for each portion of the plant, leads to substantial reductions in the effort of characterizing a plant's radiation environment. As an additional benefit, the database serves as a tool for documenting the shielding calculations themselves, automatically generating formatted sections including drawing and source term references, shielding calculation types, key dimensions, and results; these sections can form the starting point of a full calculation package. The approach offers a final project management benefit: estimating, tracking, and predicting the effort associated with the many calculations involved in such a project are greatly systematized, leading to more reliable manpower estimates. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparison of the Baseline USL Calculation Methods for Loosely-Coupled and Novel Neutronic Systems [Slides]

Current work includes reconstructing 187-group ENDF B/VII.1 covariance matrix for comparison study to 44-group ENDF B/VII.1 matrix to determine how covariance matrix structures affect the USL calculations and investigating the exact domination mechanism of region-wise sensitivities in a loosely-coupled system. Future work will involve seeking to understand how bias distributions change with reactivity and how to calculate propagate distribution error into USL calculations, as well as how cross section perturbation studies can be extended to other types of calculations, such as shielding calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SCALE Continuous-Energy Monte Carlo Depletion with Parallel KENO in TRITON

The TRITON sequence of the SCALE code system is a powerful and robust tool for performing multigroup (MG) reactor physics analysis using either the 2-D deterministic solver NEWT or the 3-D Monte Carlo transport code KENO. However, as with all MG codes, the accuracy of the results depends on the accuracy of the MG cross sections that are generated and/or used. While SCALE resonance self-shielding modules provide rigorous resonance self-shielding, they are based on 1-D models and therefore 2-D or 3-D effects such as heterogeneity of the lattice structures may render final MG cross sections inaccurate. Another potential drawback to MG Monte Carlo depletion is the need to perform resonance self-shielding calculations at each depletion step for each fuel segment that is being depleted. The CPU time and memory required for self-shielding calculations can often eclipse the resources needed for the Monte Carlo transport. This summary presents the results of the new continuous-energy (CE) calculation mode in TRITON. With the new capability, accurate reactor physics analyses can be performed for all types of systems using the SCALE Monte Carlo code KENO as the CE transport solver. In addition, transport calculations can be performed in parallel mode on multiple processors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Criticality calculations and shielding analysis of the Missouri S and T research reactor using SCALE-6.2.2 - 25408

A 3D model of the Missouri S and T Research Reactor (MSTR) was developed using SCALE-6.2.2 in this study. The criticality calculation of MSTR was modeled with the CSAS6/KENO-VI sequence within the SCALE-6.2.2 package. The critical control rods height was predicted, and the criticality was achieved when the control rod withdrawn 22.25 in with the k{sub eff} value of 1.0001±0.00083. Then, the neutron source distribution of the critical core was used as a mesh source for the shielding analysis. The shielding analysis was performed using a flexible MAVRIC/FW-CADIS model of the MSTR that could perform and analyze deep penetration shielding problems. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Rachet Door Shielding Design Calculations

The ratchet wall at the experimental floor side will have sliding doors to provide access to beamline front ends during installation and maintenance. The thickness and design of these sliding doors should provide shielding equivalence of the concrete thickness of the ratchet wall. Each of the sliding doors will be a composite to provide effective shielding from neutron and gamma radiation, emanating from beam losses inside the storage ring.

36 MATERIALS SCIENCE↗

Sci-Fri AM: Quality, Safety, and Professional Issues 03: The Increasing Costs of Shielding Diagnostic CT Scanners in Ontario

Purpose: In Ontario, shielding for all X-ray machines, including CT scanners, must be evaluated according to Safety Code 20A (Health Canada, 1983) which is based on NCRP-49 (NCRP, 1976). NCRP-147 (NCRP, 2004) is the international standard for shielding calculations of CT scanners and is also referenced in Safety Code 35 (Health Canada, 2008) which, was published to supersede SC20A. The goal of this work is to demonstrate the cost effectiveness of NCRP-147 for CT scanner shielding. Methods: CT scanner shielding calculations are performed using SC20A and NCRP-147: A room located on the third floor with the nearest building 75m away A room with high occupancy uncontrolled adjacent spaces Two side by side rooms on the main floor Results: 1. SC20A: The exterior windows required 0.1mm of Pb to protect the public who may occupy the building at 75m. 1. NCRP-147: No additional shielding required. 2. SC20A: Two walls adjacent to high occupancy uncontrolled space required an additional 1.58mm Pb. 2. NCRP-147: No additional shielding required. 3. SC20A: The entire floor and ceiling slabs in both rooms required an additional 0.79mm Pb. In addition, 0.79mm Pb was added to the walls from the ceiling to overlap the existing Pb shielding in the walls. 3. NCRP-147: No additional shielding required. Conclusion: The application of NCRP Report No. 147 affords the required protection to staff and the public, in the true spirit of the ALARA principle, taking into account relevant social and economic factors.

60 APPLIED LIFE SCIENCES↗

SU-E-T-273: Radiation Shielding for a Fixed Horizontal-Beam Linac in a Shipping Container and a Conventional Treatment Vault

Purpose: A fixed horizontal-beam linac, where the patient is treated in a seated position, could lower the overall costs of the treatment unit and room shielding substantially. This design also allows the treatment room and control area to be contained within a reduced space, such as a shipping container. The main application is the introduction of low-cost, high-quality radiation therapy to low- and middle-income regions. Here we consider shielding for upright treatments with a fixed-6MV-beam linac in a shipping container and a conventional treatment vault. Methods: Shielding calculations were done for two treatment room layouts using calculation methods in NCRP Report 151: (1) a shipping container (6m × 2.4m with the remaining space occupied by the console area), and (2) the treatment vault in NCRP 151 (7.8m by 5.4m by 3.4m). The shipping container has a fixed gantry that points in one direction at all times. For the treatment vault, various beam directions were evaluated. Results: The shipping container requires a primary barrier of 168cm concrete (4.5 TVL), surrounded by a secondary barrier of 3.6 TVL. The other walls require between 2.8–3.3 TVL. Multiple shielding calculations were done along the side wall. The results show that patient scatter increases in the forward direction and decreases dramatically in the backward direction. Leakage scatter also varies along the wall, depending largely on the distance between the gantry and the wall. For the treatment room, fixed-beam requires a slightly thicker primary barrier than the conventional linac (0.6 TVL), although this barrier is only needed in the center of one wall. The secondary barrier is different only by 0–0.2 TVL. Conclusion: This work shows that (1) the shipping container option is achievable, using indigenous materials for shielding and (2) upright treatments can be performed in a conventional treatment room with minimal additional shielding. Varian Medical Systems.

07 ISOTOPE AND RADIATION SOURCES↗

Radiation transmission data for radionuclides and materials relevant to brachytherapy facility shielding

To address the limited availability of radiation shielding data for brachytherapy as well as some disparity in existing data, Monte Carlo simulation was used to generate radiation transmission data for {sup 60}Co, {sup 137}Cs, {sup 198}Au, {sup 192}Ir, {sup 169}Yb, {sup 170}Tm, {sup 131}Cs, {sup 125}I, and {sup 103}Pd photons through concrete, stainless steel, lead, as well as lead glass and baryte concrete. Results accounting for the oblique incidence of radiation to the barrier, spectral variation with barrier thickness, and broad beam conditions in a realistic geometry are compared to corresponding data in the literature in terms of the half value layer (HVL) and tenth value layer (TVL) indices. It is also shown that radiation shielding calculations using HVL or TVL values could overestimate or underestimate the barrier thickness required to achieve a certain reduction in radiation transmission. This questions the use of HVL or TVL indices instead of the actual transmission data. Therefore, a three-parameter model is fitted to results of this work to facilitate accurate and simple radiation shielding calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Comparison of the FW-CADIS and MR-CADIS Variance Reduction Methods

The Consistent Adjoint Driven Importance Sampling (CADIS) method, which uses an adjoint deterministic estimate for making variance reduction parameters that optimize Monte Carlo (MC) shielding calculations, was introduced in 1998. This method was designed to optimize a single tally, typically an integrated response such as a detector count rate or a dose rate. Because both deterministic and stochastic methods are employed, CADIS is referred to as a hybrid method. In 2007, the forward-weighted CADIS (FW-CADIS) method was introduced to optimize several tallies at once, giving more uniform relative uncertainties among the tallies for both high-flux and low-flux areas of the problem. This method can be used for several small detectors, for semi-global problems (mesh tally over a large fraction of the problem), or for global problems (mesh tally over the entire problem). Optimization can be done for an integrated response such as a dose rate D(r) as a function of position, the total flux {phi}(r) as a function of position, or the space/energy flux {phi}(r,E). Both the CADIS and FW-CADIS methods have been in the MAVRIC sequence of SCALE for three versions (6.0 in 2009, 6.1 in 2011, and 6.2 in 2016). The ADVANTG package released in 2015 uses the CADIS and FW-CADIS methods to accelerate MCNP neutron/photon shielding calculations. In 2014, the multi-response CADIS (MR-CADIS) method was presented as a way to obtain even more uniform relative uncertainties for problems with multiple tallies than those obtained with FW-CADIS. The method does not use a forward deterministic calculation but instead uses one adjoint calculation for every tally to be optimized in the Monte Carlo calculation. This work compares the above methods.

42 ENGINEERING↗

WE-DE-207B-09: Scatter Radiation Measurement From a Digital Breast Tomosynthesis System and Its Impact On Shielding Consideration

Purpose: To accurately measure the scatter radiation from a Hologic digital breast tomosynthesis (DBT) system and to provide updated scatter distribution to guide radiation shielding calculation for DBT rooms. Methods: A high sensitivity GOS-based linear detector was used to measure the angular distribution of scatter radiation from a Hologic Selenia Dimensions DBT system. The linear detector was calibrated for its energy response of typical DBT spectra. Following the NCRP147 approach, the measured scatter intensity was normalized by the primary beam area and primary air kerma at 1m from the scatter phantom center and presented as the scatter fraction. Direct comparison was made against Simpkin’s initial measurement. Key parameters including the phantom size, primary beam area, and kV/anode/target combination were also studied. Results: The measured scatter-to-primary-ratio and scatter fraction data closely matched with previous data from Simpkin. The measured data demonstrated the unique nonisotropic distribution of the scattered radiation around a Hologic DBT system, with two strong peaks around 25° and 160°. The majority scatter radiation (>70%) originated from the imaging detector assembly, instead of the phantom. With a workload from a previous local survey, the scatter air kerma at 1m from the phantom center for wall/door is 0.018mGy/patient, for floor is 0.164mGy/patient, and for ceiling is 0.037mGy/patient. Conclusion: Comparing to Simpkin’s previous data, the scatter air kerma from Holgoic DBT is at least two times higher. The main reasons include the harder primary beam with higher workload, added tomosynthesis acquisition, and strong small angle forward scattering. Due to the highly conservative initial assumptions, the shielding recommendation from NCRP147 is still sufficient for the Hologic DBT system given the workload from a previous local survey. With the data provided from this study, accurate shielding calculation can be performed for Hologic DBT systems with specific workload and barrier distance.

60 APPLIED LIFE SCIENCES↗

Approximate angular distribution and spectra for geomagnetically trapped protons in low-earth orbit

The highly anisotropic nature of the radiation in the low-earth orbit has been ignored for most spacecraft shielding calculations made to date because the standard environmental models describe the omnidirectional flux only, because the varying attitude of the spacecraft in the environment is assumed to average out the effect and because of the added complexity of the calculation. The Space Station is planned to be stabilized with respect to the velocity vector and local vertical. Thus it will pass through the South Atlantic Anomaly where most of the radiation flux is encountered in much the same attitude on each pass. Any calculation including a complex shielding geometry should thus consider the angular distributuon of the incident radiation. An approximate trapped proton angular distribution is presented which includes both the 'pan caked' distribution relative to the magnetic field direction and the east-west effect which is energy dependent. This distribution is then used with a planar shielding geometry to obtain an estimate of the effect of the anisotropy on radiation dose rates in spacecraft.

Watts, J. W.↗

Optimization of the Shielding of a Canister Loading Machine with the deterministic Code Attila{sup R} - Paper 61

In general shielding components are designed with very conservative assumptions and boundary conditions to cover all possibly occurring situations. This often results in an overestimated shielding design in a lot of different fields of application; the shielding of components will be heavier and more expensive than needed. In most cases an initial shielding calculation in the design process shows an unbalanced shielding effect of the shielded radiation source. Sometimes the dose rate limits are slightly exceeded in several areas. From this arises a need for an optimization of the shielding structure. The goal is to decrease the radiation level in the accessible areas to keep the dose rate limits and to reduce the amount of the used shielding material if possible. Shielding material is moved from areas with higher shielding factors to which with lower ones. The optimization process is shown in an example of a loading machine for vitrified waste in canisters. The design review with an optimization of the shielding geometry was done with the deterministic code Attila{sup R} of the company Transpire, Inc. Attila{sup R} is a powerful tool to calculate and optimize the shielding effect of handling facilities for radioactive materials. It is easy to handle with its CAD integration module and an easy setup of the calculation cases. Areas with a low shielding effect which results in an exceeding of the dose rate limits can be found quickly with the illustration due to an Iso-Dose-Rate-Surface in the 3D Model. In these areas the shielding effect has to be improved. Otherwise there is material, which has no significant influence on the shielding effect and makes the handling facilities heavier and more expensive as needed. The optimization of the shielding design of the canister loading machine in the current case results in lower dose rates outside the facility to keep the dose rate limits. The demand of shielding material could be reduced and resulted in a cost reduction on the facility itself and furthermore in the caring facilities to transport this facility (cranes, etc.). (authors)

42 ENGINEERING↗

Design considerations for a Space Station radiation shield for protection from both man-made and natural sources

This study was conducted to analyze scenarios involving the use of nuclear-power vehicles in the vicinity of a manned Space Station (SS) in low-earth-orbit (LEO) to quantify their radiological impact to the station crew. In limiting the radiant dose to crew members, mission planners may (1) shut the reactor down prior to reentry, (2) position the vehicle at a prescribed parking distance, and (3) deploy radiation shield about the shutdown reactor. The current report focuses on the third option in which point-kernel gamma-ray shielding calculations were performed for a variety of shield configurations for both nuclear electric propulsion (NEP) and nuclear thermal rocket (NTR) vehicles. For a returning NTR vehicle, calculations indicate that a 14.9 MT shield would be needed to limit the integrated crew exposure to no more than 0.05 Sv over a period of six months (25 percent of the allowable exposure to man-made radiation sources). During periods of low vehicular activity in LEO, the shield may be redeployed about the SS habitation module in order to decrease crew exposures to trapped proton radiations by approximately a factor of 10. The corresponding shield mass required for deployment at a returning NEP vehicle is 2.21 MT. Additional scenarios examined include the radioactivation of various metals as might be found in tools used in EVA activities.

Bolch, Wesley E.↗

SU-E-T-554: Monte Carlo Calculation of Source Terms and Attenuation Lengths for Neutrons Produced by 50–200 MeV Protons On Brass

Purpose: We used TOPAS (TOPAS wraps and extends Geant4 for medical physicists) to compare Geant4 physics models with published data for neutron shielding calculations. Subsequently, we calculated the source terms and attenuation lengths (shielding data) of the total ambient dose equivalent (TADE) in concrete for neutrons produced by protons in brass. Methods: Stage1: The Bertini and Binary nuclear models available in Geant4 were compared with published attenuation at depth of the TADE in concrete and iron. Stage2: Shielding data of the TADE in concrete was calculated for 50– 200 MeV proton beams on brass. Stage3: Shielding data from Stage2 was extrapolated for 235 MeV proton beams. This data was used in a point-line-source analytical model to calculate the ambient dose per unit therapeutic dose at two locations inside one treatment room at the Francis H Burr Proton Therapy Center. Finally, we compared these results with experimental data and full TOPAS simulations. Results: At larger angles (∼130o) the TADE in concrete calculated with the Bertini model was about 9 times larger than that calculated with the Binary model. The attenuation length in concrete calculated with the Binary model agreed with published data within 7%±0.4% (statistical uncertainty) for the deepest regions and 5%±0.1% for shallower regions. For iron the agreement was within 3%±0.1%. The ambient dose per therapeutic dose calculated with the Binary model, relative to the experimental data, was a ratio of 0.93±0.16 and 1.23±0.24 for two locations. The analytical model overestimated the dose by four orders of magnitude. These differences are attributed to the complexity of the geometry. Conclusion: The Binary and Bertini models gave comparable results, with the Binary model giving the best agreement with published data at large angle. Shielding data we calculated using the Binary model is useful for fast shielding calculations with other analytical models. This work was supported by National Cancer Institute Grant R01CA140735.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a three-dimensional APOLLO3 neutrons deterministic scheme for the CABRI reactor

CABRI is an experimental reactor to study the fuel behavior during reactivity injection transients. These transients being highly multiphysics, the development of suitable modeling and simulation tools to simulate them is important for the optimization of the tests and the control of the experimental conditions. This paper focuses on the development of an APOLLO3 deterministic core calculation tool dedicated to the CABRI transient analysis. It represents the first stage of the incremental process for the implementation of a multiphysics time-dependent modeling of the CABRI transient. The neutron calculation scheme is based on a classical two-step approach. The first step consists of a 281-energy group calculation flux with the TDT-MOC (Method Of Characteristics) solver for cross-section space and energy (23 groups) collapsing for the CABRI different assembly clusters. The bias on a 2D core neutron calculation due to the self-shielding calculation and collapsing on a restricted pattern are investigated thanks to a comparison with a direct full 2D calculation on a quarter of core. The second step relies on a pin-resolved transport 3D transport core calculation with the SN solver MINARET. A progressive numerical validation process is followed to quantify the calculation biases on reactivity and reaction rates at each step using reference calculations with the stochastic code TRIPOLI4. The next development stage toward a multiphysics scheme will be the implementation of the 3D-kinetics equation resolution and the coupling with a core thermal-hydraulics model. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of Tools for Molten Salt Reactor Dose Rate Calculations

This report discusses a preliminary assessment of the capabilities of current state-of-the-art stochastic codes Shift and MCNP6 to calculate the ex-core radiation dose rates for a simplified Molten Salt Reactor (MSR) model. The Monte Carlo code Shift has been under significant development in recent years at ORNL as part of the CASL program and is now supported by NEAMS. Originally, Shift was developed for LWR ex-core calculations but with dose rate and shielding calculations specifically requested by the NEAMS program’s MSR industry partners, the MSR Application Drivers team was tasked with assessing Shift for non-LWR applications. This was the first application of the Shift code for non-LWRs and the findings can be considered preliminary due to the activities occurring only over a 5-month period. Attractive features of Shift include massive parallelization and advanced automated variance reduction techniques such as CADIS and FW-CADIS.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗