At least 73 records · Page 4

Annular arc accelerator shock tube

An annular arc accelerator shock tube employs a cold gas driver to flow a stream of gas from an expansion section through a high voltage electrode section to a test section, thus driving a shock wave in front of it. A glow discharge detects the shock wave and actuates a trigger generator which in turn fires spark-gap switches to discharge a bank of capacitors across a centered cathode and an annular anode in tandem electrode sections. The initial shock wave passes through the anode section from the cathode section thereby depositing energy into the flow gas without the necessity of any diaphragm opening in the gas flow from the expansion section through the electrode sections.

Leibowitz, L. P.↗

Full Facility Shock Frame Simulations of the Electric Arc Shock Tube

Radiative heating computations are performed for high speed lunar return experiments conducted in the Electric Arc Shock Tube (EAST) facility at NASA Ames Research Center. The nonequilibrium radiative transport equations are solved via NASA's in-house radiation code NEQAIR using flow field input from US3D flow solver. The post-shock flow properties for the 10 km/s Earth entry conditions are computed using the stagnation line of a blunt-body and a full facility CFD (Computational Fluid Dynamics) simulation of the EAST shock tube. The shocked gas in the blunt-body flow achieves a thermochemical equilibrium away from the shock front whereas EAST flow exhibits a nonequilibrium behavior due to strong viscous dissipation of the shock by boundary layer. The full-tube flow calculations capture the influence of the boundary layer on the shocked gas state and provide a realistic fluid dynamic input for the radiative predictions. The integrated radiance behind the shock is calculated in NEQAIR for wavelength regimes from Vacuum-UltraViolet (VUV) to InfraRed (IR), which are pertinent to the emission characteristics of high enthalpy shock waves in air. These radiance profiles are validated against corresponding EAST shots. The full-tube simulations successfully predict a sharp radiance peak at the shock front which gets smeared in the test data due to the spatial resolution in the measurements. The full facility based radiance behind the shock shows a slightly better match with the test data in the VUV and Red spectral regions, as compared to that from a blunt-body based predictions. The UV radiance is very similar for both geometries and under-predicts the test behavior. The IR test data matches better with the blunt-body based predictions where the full-tube simulations show a significant over-prediction.

Radiation↗

Calibration of PCB-132 Sensors in a Shock Tube

While PCB-132 sensors have proven useful for measuring second-mode instability waves in many hypersonic wind tunnels, they are currently limited by their calibration. Until now, the factory calibration has been all that was available, which is a single-point calibration at an amplitude three orders of magnitude higher than a second-mode wave. In addition, little information has been available about the frequency response or spatial resolution of the sensors, which is important for measuring high-frequency instability waves. These shortcomings make it difficult to compare measurements at different conditions and between different sensors. If accurate quantitative measurements could be performed, comparisons of the growth and breakdown of instability waves could be made in different facilities, possibly leading to a method of predicting the amplitude at which the waves break down into turbulence, improving transition prediction. A method for calibrating the sensors is proposed using a newly-built shock tube at Purdue University. This shock tube, essentially a half-scale version of the 6-Inch shock tube at the Graduate Aerospace Laboratories at Caltech, has been designed to attain a moderate vacuum in the driven section. Low driven pressures should allow the creation of very weak, yet still relatively thin shock waves. It is expected that static pressure rises within the range of second-mode amplitudes should be possible. The shock tube has been designed to create clean, planar shock waves with a laminar boundary layer to allow for accurate calibrations. Stronger shock waves can be used to identify the frequency response of the sensors out to hundreds of kilohertz.

Berridge, Dennis C.↗

The chemical shock tube as a tool for studying high-temperature chemical kinetics

Although the combustion of hydrocarbons is our primary source of energy today, the chemical reactions, or pathway, by which even the simplest hydro-carbon reacts with atmospheric oxygen to form CO2 and water may not always be known. Furthermore, even when the reaction pathway is known, the reaction rates are always under discussion. The shock tube has been an important and unique tool for building a data base of reaction rates important in the combustion of hydrocarbon fuels. The ability of a shock wave to bring the gas sample to reaction conditions rapidly and homogeneously makes shock-tube studies of reaction kinetics extremely attractive. In addition to the control and uniformity of reaction conditions achieved with shock-wave methods, shock compression can produce gas temperatures far in excess of those in conventional reactors. Argon can be heated to well over 10 000 K, and temperatures around 5000 K are easily obtained with conventional shock-tube techniques. Experiments have proven the validity of shock-wave theory; thus, reaction temperatures and pressures can be calculated from a measurement of the incident shock velocity. A description is given of the chemical shock tube and auxiliary equipment and of two examples of kinetic experiments conducted in a shock tube.

Brabbs, Theodore A.↗

Shock tube with implosive jet driver.

Shock tube with cylindrical explosive to implode glass wall and produce high velocity glass particle jet, studying jet velocity and behavior and test gas pressure effects

Gill, S. P.↗

Shock-tube chemistry. I - The laminar-to-turbulent boundary layer transition

A model is proposed for calculating laminar-turbulent transition in the boundary layer of flows in chemical shock tubes. It is shown that the time to turbulent transition may be treated as the time required by the shocked gas to move over one shock-tube diameter. The model is shown to provide a means of predicting the turbulent transition time in any shock tube experiment, provided the condition of limiting flow is met. Knowing the transition time, it becomes possible to obtain the density and temperature profiles and, hence, to determine precisely the effect of shock tube boundary layers on the measurement of chemical rate constants.

Bander, J. A.↗

Characterization of a new ultra-high pressure shock tube facility for combustion and propulsion studies

A new shock tube facility has been designed, constructed, and characterized at the University of Central Florida. This facility is capable of withstanding pressures of up to 1000 atm, allowing for combustion diagnostics of extreme conditions, such as in rocket combustion chambers or in novel power conversion cycles. For studies with toxic gas impurities, the high initial pressures required the development of a gas delivery system to ensure the longevity of the facility and the safety of the personnel. Data acquisition and experimental propagation were implemented with remote access to ensure safety, paired with a LabVIEW- and Python-based user interface. Thus far, test pressures of 270 atm, blast pressures of 730 atm, and temperatures approaching 10 000 K have been achieved. The extreme limitations of this facility allow for emission spectroscopy to be performed during the oxidation of fuel mixtures, e.g., alkanes diluted in argon and carbon dioxide. Ignition delay times were determined and compared to simulations using chemical kinetic mechanisms. The design, experimental procedures, processes of analysis, and uncertainty determination are outlined, and typical pressure profiles are compared with a new gas dynamics solver and empirical correlations developed across multiple shock tube facilities. Preliminary reactive mixture analyses are included with further investigation of the mixtures outlined.

47 OTHER INSTRUMENTATION↗

Application of shock tubes to transonic airfoil testing at high Reynolds numbers

Performance analysis of a gas-driven shock tube shows that transonic airfoil flows with chord Reynolds numbers of the order of 100 million can be produced, with limitations being imposed by the structural integrity of the facility or the model. A study of flow development over a simple circular arc airfoil at zero angle of attack was carried out in a shock tube at low and intermediate Reynolds numbers to assess the testing technique. Results obtained from schlieren photography and airfoil pressure measurements show that steady transonic flows similar to those produced for the same airfoil in a wind tunnel can be generated within the available testing time in a shock tube with properly contoured test section walls.

Cook, W. J.↗

A study of test section configuration for shock tube testing of transonic airfoils

Two methods are investigated for alleviating wall interference effects in a shock tube test section intended for testing two-dimensional transonic airfoils. The first method involves contouring the test section walls to match approximate streamlines in the flow. Contours are matched to each airfoil tested to produce results close to those obtained in a conventional wind tunnel. Data from a previous study and the present study for two different airfoils demonstrate that useful results are obtained in a shock tube using a test section with contoured walls. The second method involves use of a fixed-geometry slotted-wall test section to provide automatic flow compensation for various airfoils. The slotted-wall test section developed exhibited the desired performance characteristics in the approximate Mach number range 0.82 to 0.89, as evidenced by good agreement obtained between shock tube and wind tunnel results for several airfoil flows.

Cook, W. J.↗

Laser Absorption Spectroscopy Measurements of Post-Shock Non-Equilibrium Species in the NASA Ames Electric Arc Shock Tube

The NASA Ames Electric Arc Shock Tube (EAST) is a unique facility capable of generating high enthalpy, shock-heated impulse gas flows representative of the kinetic and radiative conditions encountered by atmospheric entry vehicles. The facility maintains a successful history with emission spectroscopy, providing measurements of absolute radiance upon which various validation studies are anchored. The central objective of this work is to develop a comprehensive tunable diode laser absorption spectroscopy (TDLAS) sensing capability to provide complementary experimental insights to existing emission techniques. More specifically, a fast-scanning TDLAS-based diagnostic targeting the cyano radical (CN) in the near-infrared(near-IR) near 926.6 nm is employed in mixtures of 2.2% CH4in N2by mole for a sweep of incident shock velocities ranging 3.0-5.5 km/s and fill pressures 0.3-1.15 Torr. Laser scan rates up to 500 kHz probe multiple absorption features to provide quantitative measurements of temperature and species number density profiles behind the incident shock. In all instances, the temperature trend is consistent between emission-inferred and TDLAS-inferred measurements. However, at the lower-velocity conditions, there is an appreciable offset between the Data Parallel Line Relaxation Code (DPLR) simulation and experimental measurements. A similar behavior is observed in number density profiles, with emission measurements providing inferences of the CN(B) and CN(A) state, while TDLAS measurements provide an additional inference of the CN(X) state. In the fast-scanned experiments, measurement inferred number densities suggest a much faster production of CN at early times than captured by the model. This discrepancy motivates ongoing, additional spectroscopic and kinetics CN experiments to resolve the accuracy of modeling assumptions.

Efaine Chang↗

Computational Modeling for Non-Equilibrium Shock Tube Flows

Time accurate simulation of non-equilibrium flows inside shock tube facilities presents several challenges from both physical and mathematical aspects. Furthermore, the large computational cost makes it impractical to support a real-time experimental test campaign. In this work, we explore other methods for modeling the shock tube problem with the main focus on the post-shock region and the absolute radiation emanating from it. The proposed alternative approach is several orders of magnitude less computationally expensive while still accurate enough with regards to the quantities of interest. Excellent agreement is found with the established stagnation-line approach. Comparison with time-accurate simulations shows good agreement close to the peak values and disagreement of the temperatures relaxation and radiance profiles toward equilibrium.

Bensassi, Khalil↗

Computational Modeling for Non-equilibrium Shock Tube Flows

Time accurate simulation of non-equilibrium flows inside shock tube facilities presents several challenges from both physical and mathematical aspects. Furthermore, the drastic computational cost makes it non-practical to support real-time experimental test campaign. In this work, we explore other methods for modeling the shock tube prob- lem with the main focus on the post-shock region and the absolute radiation emanating from it. The proposed alternative approach is several orders of magnitude less computa- tionally expansive while still accurate enough with regards to the quantities of interest. Excellent agreement is found with the well-established stagnation-line approach. Comparison with the time-accurate simulation shows good agreement close to the peak values and disagreement of the temperatures relaxation and radiance profiles toward equilibrium, due to shock speed unsteadiness.

Bensassi, Khalil↗

High-Speed X-Ray Stereo Digital Image Correlation in a Shock Tube

X-ray stereo digital image correlation (DIC) measurements were performed at 10 kHz on the internal surface of a jointed structure in a shock tube at a shock Mach number of 1.42 and compared with optical stereo DIC measurements on the outer, visible surface of the structure. The shock tube environment introduces temperature and density gradients in the gas through which the structure was imaged, resulting in spatial and temporal index of refraction variations. These variations cause bias errors in optical DIC measurements due to beam-steering but have minimal influence on x-ray DIC measurements. These results demonstrate the utility of time-resolved x-ray DIC measurements in complicated environments where optical measurements suffer severe errors and/or are precluded by lack of optical access.

42 ENGINEERING↗

Shock Tube Measurements of Radiative Heating for Titan and Nitrogen

Detailed spectrally and spatially resolved radiance has been measured in the Electric Arc Shock Tube at NASA Ames Research Center for conditions relevant to Titan entry, with varying atmospheric composition, free-stream density (equivalently, altitude) and shock velocity. The test campaign measured radiation at velocities from 4.7 km/s to 8 km/s and free-stream pressures of 0.1, 0.28 and 0.47 Torr with a variety of compositions. Radiances measured in this work are substantially larger compared to that reported both in past EAST test campaigns and in other shock tube facilities. Depending on the metric used for comparison, the discrepancy can be as high as an order of magnitude. Due to the difference with previously reported data, a substantial effort was undertaken to provide confidence in the new results. The present work provides a new benchmark set of data to replace those published in previous studies. The effect of gas impurities identified in previous shock tube studies was also examined by testing in pure N2 and deliberate addition of air to the CH4/N2 mixtures. Furthermore, a test campaign in pure N2 was also conducted with the aim of providing data for improving fundamental understanding of high enthalpy flows containing N2, such as high-speed entries into Earth or Titan. These experiments cover conditions from approximately 6 km/s to 11 km/s at an initial pressure of 0.2 Torr. It is the intention of this paper to motivate code comparisons benchmarked against this data set.

Radiation↗