Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single Ion Conducting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Quaternized poly(arylene ether benzonitrile) membranes for vanadium redox flow batteries

In this work, a series of quaternized poly (arylene ether benzonitrile)s (QAxCN; x = percent quaternization) were synthesized for the vanadium redox flow battery (VRFB) application. The presence of highly polar nitrile groups incorporated in the quaternized polymer chain provides desirable polymer properties (low water uptake, high dimensional stability and low VO 2+ permeability) without compromising ion conductivity. VRFB single cells using the aforementioned membranes showed excellent performance. As a result, the cell using a 15 μm-thick QA50CN membrane exhibited superior coulombic efficiency (98.2%) and comparable energy efficiency (86.5%) at 40 mA cm -2 compared to the single cell using Nafion-212 with a coulombic efficiency of 95.5% and an energy efficiency of 86.2%. The cell cycling stability and membrane oxidative stability data confirmed that the QAxCN membranes have the potential to replace Nafion membranes for energy storage in VRFB applications.

25 ENERGY STORAGE↗

Emergent Nanostructure and Ion Transport in Polyzwitterion/Polyanion Blends

Solid polymer electrolytes (SPEs) hold great promise for the advancement of next-generation energy storage devices. However, the ion transport mechanism in SPEs remains poorly understood. In this study, we investigate blends of poly(1-(3-sulfonatopropyl)-2-vinylpyridinium) (P2VPPS) and poly(lithium (trifluoromethane)sulfonimide methacrylate) (P(MTFSI)Li) of varying molar ratios to develop a mechanistic understanding of ionic conductivity in a miscible polyzwitterion/polyanion system. Polyanions can act as single-ion conductors, but conductivity is often prohibitively low due to the decreased segmental mobility and ion aggregation. Here, it is hypothesized that the introduction of a polyzwitterion would competitively interact with the polyanion charge groups to realize improvements in the conductivity. Attractive interactions between the polyanions and polyzwitterions are confirmed by the blend’s increased glass transition temperature using the Gordon–Taylor equation. Notably, an ordered local nanostructure (∼24 Å) emerged in the P2VPPS/P(MTFSI)Li system at certain compositions, as characterized by small-angle X-ray and neutron scattering (SAXS/SANS). Concurrent with the emergence of this structure, broadband dielectric spectroscopy confirmed improvements in ionic conductivity. The highest conductivity is observed at a specific blend ratio P2VPPS:P(MTFSI)Li = 0.2:1 in the glassy state and 0.3:1 in the rubbery state, corresponding to the lowest effective activation energy (E*). Coarse-grained molecular dynamics simulations further emphasize the role of complexation between polyzwitterion and polyanion chains, correlating with the emergence of a new peak in SAXS and SANS for the blends. This work provides a fresh perspective on the role of local structural design in developing SPEs and offers insights into the morphological effects on ionic conductivity.

chemical structure↗

Optimization of Graphite–SiO blend electrodes for lithium-ion batteries: Stable cycling enabled by single-walled carbon nanotube conductive additive

Lithium-alloying materials are of great interest to improve the gravimetric and volumetric energy density of lithium-ion batteries, though their associated volume fluctuation with cycling often leads to poor cycling performance. Active-inactive alloys and blending alloys with carbon materials are common strategies to accommodate volume fluctuation. Herein we set out to optimize graphite-SiO blend electrode formulations to eliminate rapid capacity fade. Electrodes with highly stable cycling were prepared by simple planetary mixing procedures, enabled by the use of just a fraction of a weight percent of commercial SWCNTs as the only conductive additive, and by the appropriate choice of binder/stabilizing agent. In fact, the use of SWCNTs allowed for graphite-free SiO electrodes with approximately 74% higher volumetric energy density relative to traditional graphite electrodes, and superior capacity retention in coin-type full-cell testing versus NMC532 cathodes.

25 ENERGY STORAGE↗

Ion concentration polarization causes a nearly pore-length-independent conductance of nanopores

There has been a great amount of interest in nanopores as the basis for sensors and templates for preparation of biomimetic channels as well as model systems to understand transport properties at the nanoscale. The presence of surface charges on the pore walls has been shown to induce ion selectivity as well as enhance ionic conductance compared to uncharged pores. Here, using three-dimensional continuum modeling, we examine the role of the length of charged nanopores as well as applied voltage for controlling ion selectivity and ionic conductance of single nanopores and small nanopore arrays. First, we present conditions where the ion current and ion selectivity of nanopores with homogeneous surface charges remain unchanged, even if the pore length decreases by a factor of 6. This length-independent conductance is explained through the effect of ion concentration polarization (ICP), which modifies local ionic concentrations, not only at the pore entrances but also in the pore in a voltage-dependent manner. We describe how voltage controls the ion selectivity of nanopores with different lengths and present the conditions when charged nanopores conduct less current than uncharged pores of the same geometrical characteristics. The manuscript provides different measures of the extent of the depletion zone induced by ICP in single pores and nanopore arrays, including systems with ionic diodes. In conclusion, the modeling shown here will help design selective nanopores for a variety of applications where single nanopores and nanopore arrays are used.

Cain, DaVante↗

Water, Solute, and Ion Transport in De Novo-Designed Membrane Protein Channels

Biological organisms engineer peptide sequences to fold into membrane pore proteins capable of performing a wide variety of transport functions. Synthetic de novo-designed membrane pores can mimic this approach to achieve a potentially even larger set of functions. Here, in this work, we explore water, solute, and ion transport in three de novo designed β-barrel membrane channels in the 5–10 Å pore size range. We show that these proteins form passive membrane pores with high water transport efficiencies and size rejection characteristics consistent with the pore size encoded in the protein structure. Ion conductance and ion selectivity measurements also show trends consistent with the pore size, with the two larger pores showing weak cation selectivity. MD simulations of water and ion transport and solute size exclusion are consistent with the experimental trends and provide further insights into structure–function correlations in these membrane pores.

59 BASIC BIOLOGICAL SCIENCES↗

Effect of Tethering Anions in Block Copolymer Electrolytes via Molecular Dynamics Simulations

Ion-containing block copolymers (BCPs) are promising solid-state electrolytes as they can combine ion conduction and mechanical robustness via multiple microphases. However, salt-doped BCPs can have low ion conduction and transference number. One strategy to increase transference number is to tether anions to the polymer backbone (creating a single-ion conductor), though this may impact cation mobility. Leveraging coarse-grained molecular dynamics simulations, we compare the effects of ion concentration and polymer dielectric constant on BCPs with and without bonding anions to the chain (without changing any other chemical properties). We find that single-ion BCPs have higher cation conductivity than analogous salt-doped BCPs, especially at moderate ion concentrations. Furthermore, we also compare several structural features of these systems; notably, tethering anions causes the ions to spread more evenly throughout the conducting phase, which is related to improved cation conduction.

25 ENERGY STORAGE↗

Mechanisms of activation and desensitization of full-length glycine receptor in lipid nanodiscs

Glycinergic synapses play a central role in motor control and pain processing in the central nervous system. Glycine receptors (GlyRs) are key players in mediating fast inhibitory neurotransmission at these synapses. While previous high-resolution structures have provided insights into the molecular architecture of GlyR, several mechanistic questions pertaining to channel function are still unanswered. Here, we present Cryo-EM structures of the full-length GlyR protein complex reconstituted into lipid nanodiscs that are captured in the unliganded (closed), glycine-bound (open and desensitized), and allosteric modulator-bound conformations. A comparison of these states reveals global conformational changes underlying GlyR channel gating and modulation. The functional state assignments were validated by molecular dynamics simulations, and the observed permeation events are in agreement with the anion selectivity and conductance of GlyR. These studies provide the structural basis for gating, ion selectivity, and single-channel conductance properties of GlyR in a lipid environment.

59 BASIC BIOLOGICAL SCIENCES↗

Ion Transport in Carbon Nanotube Porins with a pH-Switchable Entrance Gate

Molecular transport in nanofluidic channels often differs drastically from conventional bulk transport. Strong confinement in those channels amplifies the roles of surface transport, surface defects, and molecular gates. Here, in this study, we introduce a chemical functionality at the nanotube rim that acts as a pH-triggered molecular gate by forming a movable lid that blocks the pore entrance. We use ion and proton transport measurements to show that these sub-1 nm diameter fluorescent ultrashort carbon nanotube porins (FUNPs) modulate ion transport by switching between the “open” and “closed” conformations of this gate. Specifically, at neutral pH the channel lid is open, allowing unimpeded ion transport through the gate, whereas at acidic pH values the lid forms a “closed” conformation that blocks transport through the nanotube. We also report first-principles MD simulations that confirm this gating mechanism and reveal molecular details of the ion and proton transport processes in these functional nanopores.

Carbon nanotubes↗

Fundamental processes in the expansion, energization, and coupling of single- and multi-Ion plasmas in space: Laboratory simulation experiments

We have conducted a laboratory investigation into the physics of plasma expansions and their associated energization processes. We studied single- and multi-ion plasma processes in self-expansions, and included light and heavy ions and heavy/light mixtures to encompass the phenomenological regimes of the solar and polar winds and the AMPTE and CRRES chemical release programs. The laboratory experiments provided spatially-distributed time-dependent measurements of total plasma density, temperature, and density fluctuation power spectra with the data confirming the long-theorized electron energization process in an expanding cloud - a result that was impossible to determine in spaceborne experiments (as e.g., in the CRRES program). These results provided the missing link in previous laboratory and spaceborne programs. confirming important elements in our understanding of such solar-terrestrial processes as manifested in expanding plasmas in the solar wind (e.g., CMES) and in ionospheric outflow in plasmaspheric fluctuate refilling after a storm. The energization signatures were seen in an entire series of runs that varied the ion species (Ar', Xe', Kr' and Ne'), and correlative studies included spectral analyses of electrostatic waves collocated with the energized electron distributions. In all cases wave energies were most intense during the times in which the suprathermal populations were present, with wave intensity increasing with the intensity of the suprathermal electron population. This is consistent with theoretical expectations wherein the energization process is directly attributable to wave particle interactions. No resonance conditions were observed, in an overall framework in which the general wave characteristics were broadband with power decreasing with increasing frequency.

Szuszczewicz, E. P.↗

Computational study of Li3BO3 and Li3BN2 I: Electrolyte properties of pure and doped crystals

Both Li3BO3 and Li3BN2 materials have promising properties for use in all-solid-state batteries and other technologies dependent on electrolytes with significant ionic conductivity. As the first of a two-part study, this paper reports the analysis of detailed simulations of Li ion diffusion in the monoclinic forms of these materials. Using both NEB and MD methods, it is clear that Li ion migration via vacancy mechanisms provides the most efficient ion transport in each material. While the results suggest that interstitial defects in these materials do not play a direct role in Li ion migration, their relative stability seems to enhance vacancy production via the formation of Frenkel-type defects. This may partially explain why the Li ion conductivities computed from MD simulations of samples initially containing a single Li ion vacancy are in reasonable agreement with measured values of this work for Li3BO3 and those reported in the literature for poorly crystalline samples of both materials. The possibility of increasing vacancy concentrations by substitutional doping (F for O in Li3BO3 and C for B in Li3BN2) is also examined, finding simulated conductivities comparable to those of the ideal vacancy model.

Li, Yan↗

Single-Event Effect Testing of the Vishay Si7414DN n-Type TrenchFET(Registered Trademark) Power MOSFET

This study was being undertaken to determine the single event effect susceptibility of the commercial Vishay 60-V TrenchFET power MOSFET. Heavy-ion testing was conducted at the Texas AM University Cyclotron Single Event Effects Test Facility (TAMU) and the Lawrence Berkeley National Laboratory BASE Cyclotron Facility (LBNL). In addition, initial 200-MeV proton testing was conducted at Massachusetts General Hospital (MGH) Francis H. Burr Proton Beam Therapy Center. Testing was performed to evaluate this device for single-event effects from lower-LET, lighter ions relevant to higher risk tolerant space missions.

proton testing↗

Thermal transport across nanoscale damage profile in sapphire irradiated by swift heavy ions

In this work, we studied the degradation of thermal conductivity in single crystal sapphire (α-Al 2 O 3 ) irradiated by 167 MeV Xe swift heavy ions (SHIs) over the multiple fluences in the range of 10 12 –10 14 ions/cm 2 . Thermal conductivity was measured primarily in the cross-plane direction using a noncontact ultrafast optical pump-probe technique called picosecond time domain thermoreflectance (TDTR). Multiple samples with variable ion fluences allowed us to probe distinct regions resulting from different regimes of microstructure evolution caused by electronic energy loss. By tuning the penetration depth of the thermal waves using different modulation frequencies, two regions with distinct conductivities were identified and the values of which were found to be consistent with phonon-mediated thermal transport models while the microstructure was confirmed by electron microscopy characterization. These damaged regions were determined to be a several micrometer thick ion track region and several tens of nanometer-thick amorphous layer present only above 5.0 × 10 13 ions/cm 2 . These results demonstrate the applicability of TDTR to resolve thermal transport behavior in SHI irradiated oxides having nonhomogeneous damage profile on a nanometer scale. The presented approach facilitates future studies aiming at resolving the impact of distinct damage resulting from electronic and nuclear stopping regimes under irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Free-Energy Calculations. A Mathematical Perspective

Ion channels are pore-forming assemblies of transmembrane proteins that mediate and regulate ion transport through cell walls. They are ubiquitous to all life forms. In humans and other higher organisms they play the central role in conducting nerve impulses. They are also essential to cardiac processes, muscle contraction and epithelial transport. Ion channels from lower organisms can act as toxins or antimicrobial agents, and in a number of cases are involved in infectious diseases. Because of their important and diverse biological functions they are frequent targets of drug action. Also, simple natural or synthetic channels find numerous applications in biotechnology. For these reasons, studies of ion channels are at the forefront of biophysics, structural biology and cellular biology. In the last decade, the increased availability of X-ray structures has greatly advanced our understanding of ion channels. However, their mechanism of action remains elusive. This is because, in order to assist controlled ion transport, ion channels are dynamic by nature, but X-ray crystallography captures the channel in a single, sometimes non-native state. To explain how ion channels work, X-ray structures have to be supplemented with dynamic information. In principle, molecular dynamics (MD) simulations can aid in providing this information, as this is precisely what MD has been designed to do. However, MD simulations suffer from their own problems, such as inability to access sufficiently long time scales or limited accuracy of force fields. To assess the reliability of MD simulations it is only natural to turn to the main function of channels - conducting ions - and compare calculated ionic conductance with electrophysiological data, mainly single channel recordings, obtained under similar conditions. If this comparison is satisfactory it would greatly increase our confidence that both the structures and our computational methodologies are sufficiently accurate. Channel conductance, defined as the ratio of ionic current through the channel to applied voltage, can be calculated in MD simulations by way of applying an external electric field to the system and counting the number of ions that traverse the channel per unit time. If the current is small, a voltage significantly higher than the experimental one needs to be applied to collect sufficient statistics of ion crossing events. Then, the calculated conductance has to be extrapolated to the experimental voltage using procedures of unknown accuracy. Instead, we propose an alternative approach that applies if ion transport through channels can be described with sufficient accuracy by the one-dimensional diffusion equation in the potential given by the free energy profile and applied voltage. Then, it is possible to test the assumptions of the equation, recover the full voltage/current dependence, determine the reliability of the calculated conductance and reconstruct the underlying (equilibrium) free energy profile, all from MD simulations at a single voltage. We will present the underlying theory, model calculations that test this theory and simulations on ion conductance through a channel that has been extensively studied experimentally. To our knowledge this is the first case in which the complete, experimentally measured dependence of the current on applied voltage has been reconstructed from MD simulations.

free energy↗

Cardiovascular Responses to Simulated Spaceflight: Molecular Signatures and Surrogate Outputs to Measure CVD Risk

During extended space missions beyond low Earth orbit, astronauts will encounter prolonged periods of weightlessness and low dose space radiation. Previous studies have shown that exposure to small doses of high LET radiation (< 50 cGy) can lead to both short-term and long-term alterations in heart function, structure and underlying molecular mechanisms. In this study, we aim to identify the molecular signature associated with the cardiovascular response to simulated galactic cosmic radiation (5-ion GCR) alone or in combination with simulated weightlessness at time intervals relevant to mission length and recovery. Additionally, we aim to determine whether sex impacts cardiovascular responses to these spaceflight factors. Our overarching goal is to enhance our understanding of the cardiovascular risks associated with extended space missions and the clinical endpoints they suggest. We hypothesize that exposure to simulated space radiation leads to enduring alterations in the transcriptome, redox signaling and cytokine environment of cardiovascular tissue, some which have known links with reduced cardiovascular performance, aging, and increased risk of cardiovascular disease (CVD). Furthermore, we posit that simulated space radiation exposure in combination with simulated microgravity exacerbates cardiovascular deficits compared to single factor exposure. Female and male C57BL/6J mice, aged 23-24 weeks, were exposed to a single dose of 5, 15, or 50 cGy of 5-ion GCR, or sham-treated (0 cGy). Euthanasia was performed at 14 days and ~4 months post-irradiation. Hearts, aorta and blood plasma were collected shortly thereafter. RNA-sequencing of left ventricles at ~4 months post-GCR exposure revealed sex differences in the heart transcriptome with a few genes showing radiation-dependent changes in expression levels. Notably, some of the differentially expressed genes in 15 and 50 cGy GCR groups are known to play roles in the development of CVD. Analysis of protein levels of a subset of inflammatory cytokines in the heart indicated sex differences but no differences between sham and 50 cGy groups. Results also showed correlations among differentially expressed genes and a subset of inflammatory cytokines, with some correlations altered by GCR exposure. These findings suggest that GCR exposure can modify protein and gene networks linked to inflammation and CVD progression. In the aorta, telomere lengths were comparable across treatment groups sexes. Mitochondrial copy number is a biomarker for mitochondrial function with decreased copy numbers associated with cardiometabolic disease traits. Mitochondrial copy numbers of aorta also showed no sex nor dose differences. In a second study, mice underwent one week of simulated microgravity by hindlimb unloading (HU) and then exposed to a single dose of 15 cGy of 5-ion GCR. HU was conducted for an additional two weeks following GCR exposure. Single factor exposure groups (HU or GCR only) also were included in the study. Euthanasia was then performed and the same tissues were collected. Protein levels of select inflammatory cytokines in the heart showed sex-dependent differences in expression. In the aorta, telomere lengths and mitochondrial copy number also showed sex differences. In summary, our results indicate differences between sexes in biomarkers related to cardiovascular health. Exposure to 5-ion GCR or HU, alone or in combination, did not result in changes in most of the cardiovascular biomarkers that were examined. However, in the heart, simulated space radiation at doses of 15 and 50 cGy led to long-term alterations in the expression levels of a small group of genes known to be associated with the progression of CVD. The long-term transcriptomic changes resulting from exposure to simulated space radiation should be carefully investigated to mitigate adverse cardiovascular events during and after deep space missions. Our results also highlight the importance of sex-specific strategies in monitoring and maintaining cardiovascular health during and after deep space missions.

cardiovascular↗

Temperature and processing effects on lithium ion conductivity of solution‐deposited lithium zirconium phosphate (LiZr 2 P 3 O 12 ) thin films

Abstract Lithium zirconium phosphate (LiZr 2 P 3 O 12 ) thin films have been prepared on platinized silicon substrates via a chemical solution deposition approach with processing temperatures between 700°C and 775°C. Films that were subject to a single high‐temperature anneal were found to crystallize at temperatures above 725°C. Crystallization was observed in films annealed after each deposited layer at 700°C and above. In both cases, grain size was found to increase with annealing temperature. Ion conductivity was found to increase with annealing temperature in singly annealed films. In per‐layer annealed films ion conductivity was found to initially increase then decrease with increasing annealing temperature. A maximum ion conductivity of 1.6 × 10 −6 S/cm was observed for the singly annealed 775°C condition, while a maximum ion conductivity of 5.8 × 10 −7 S/cm was observed for the 725°C per‐layer annealed condition. These results are consistent with an increasing influence of cross‐plane, internal interface resistance and vapor phase carrier loss in the per‐layer annealed samples. This work demonstrates that post‐deposition processing methods can strongly affect the ion conducting properties of LiZr 2 P 3 O 12 thin films.

Brummel, Ian A.↗