Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sodium Loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Status of GTA Gear Inspection after Testing in Sodium

The Mechanisms Engineering Test Loop (METL) is an intermediate-scale liquid metal experimental facility that provides purified reactor-grade (R-grade) sodium to various experimental test vessels. In these test vessels, components that are required to operate in an advanced fast reactor can be tested in a prototypical sodium environment. Experiments conducted in METL significantly assist in the development and maturation of systems and components for advanced reactors. The METL facility consists of multiple test segments including: a purification and diagnostic loop (cold trap was designed after EBR-II), two 18” diameter test vessels with 150 L capacities capable of operating in static or dynamic flow at 538°C, two 28” diameter test vessels with 644 L capacities capable of operating in static or dynamic flow at 650°C, a 3,180 L dump tank with 21 instrumentation ports, and the infrastructure to expand capacity in the future.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Benchmark Exercise Report for Experimental Study of Bubble Scrubbing in Water Coolant Pool

Mechanistic assessments of radionuclide release during postulated accidents are expected to be included in advanced reactor license applications. The mechanistic source term (MST) provides an opportunity for vendors to realistically evaluate the radiological consequences of an incident, and may aid in justifying reduced emergency planning zones and plant sites. However, the development of MSTs for advanced nuclear reactors is challenging because there are numerous phenomena that can affect the transport and retention of radionuclides. As part of a trial MST assessment for a metal-fueled, pool-type sodium cooled fast reactor (SFR), led by Argonne National Laboratory, a simplified radionuclide transport code (SRT code) was developed, which includes models to estimate the quantity of fission product aerosols scrubbed in the sodium pool during postulated accident scenarios. In a pool-type SFR, when fission products are released into the coolant pool due to failure of fuel pins, most of the radionuclides are scrubbed by the coolant pool, but some have the potential to migrate to the cover gas region through entrainment within gas bubbles. The SRT code contains a model that evaluates this scrubbing behavior and calculates the fraction of fission product aerosols that reach the cover gas. Due to a lack of available validation data for sodium pool scrubbing, the U.S. Department of Energy funded an experiment at the University of Wisconsin-Madison to measure aerosol scrubbing by injecting air bubbles containing aerosol into a coolant pool. Prior to performing an experiment with liquid sodium, a water loop experiment was performed. Their experiment evaluated the effect of changing the aerosol size, aerosol density, aerosol concentration, bubble size, and pool depth on the aerosol scrubbing efficiency of the pool. In this benchmark experiment, the base tests were conducted by repeated tests of isolated bubbles. Afterwards, more prototypic tests with bubble swarms were performed to evaluate the interactions between the bubbles. The bubble swarm test was able to confirm that a larger amount of aerosol scrubbing occurred than the single bubble test. It was also confirmed that as the bubble size, aerosol density, and pool height increase, the extent of pool scrubbing also increases and does not change with the aerosol concentration. In addition, since the degree of scrubbing is the lowest at aerosol sizes between 0.01 and 1 μm, that is, the largest amount of aerosol is emitted, it was confirmed that the analysis of this size in MST is the most important. This benchmark experiment informs the direction of future sodium experiments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report of METL Mutual Inductance Level Sensor Development for Use in Liquid Metals – FY2023

A robust mutual inductance level sensor (MILS) for use in high temperature liquid metals has been developed at Argonne National Laboratory (ANL). The current design utilizes mineral insulated cables with a 300-series stainless steel sheath, magnesium oxide insulation, and a single copper conductor. Two coils are wrapped on a common core made of a 300-series stainless steel tube. One coil is energized with an alternating current (AC) source, and this electromagnetically couples with the second coil to generate an induced voltage. The voltage is measured to determine the mutual induction between the coils, and the mutual inductance measurement can be used to determine the level of a nearby liquid metal volume. The MILS can be located in an isolating thimble that is fully sealed to a vessel containing liquid metal for ease of maintenance and replacement. When the primary coil is energized with the AC source, the coil not only electromagnetic (EM) couples with the second coil, but also the surrounding liquid metal. The EM coupling with the surrounding liquid metal reduces the EM coupling with the second coil, producing an inverse-linear relationship between liquid metal level and secondary coil voltage. This has all been demonstrated at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at ANL. The most current iteration of the MILS system is the MILS-MK-II. This sensor system has been commissioned in a non-sodium test stand where calibrations were performed using a sodium analog. The calibrations proved to be highly linear and repeatable. The MILS-MK-II has been installed in the METL expansion tank where high temperature sodium tests have been performed. The MILS-MK-II has been calibrated against a known standard at temperature of 300°C, and the calibrations have proved to be highly linear and repeatable. The calibrated MILS-MK-II has been in operation in the METL facility for several thousands of hours at temperatures around 300°C. The experimental data has been used to develop and validate electromagnetic finite element models in COMSOL Multiphysics, and now these models can be used to advance the development of the sensor system. Next steps will include temperature compensation to allow for operation at various temperatures. Additionally, efforts to incorporate a self-calibration methodology are underway.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of Sodium and Tungsten Promoters on Mg 6 MnO 8 -Based Core–Shell Redox Catalysts for Chemical Looping—Oxidative Dehydrogenation of Ethane

The present study investigates the effect of sodium and tungsten promoters on Mg 6 MnO 8 -based redox catalysts in a chemical looping oxidative dehydrogenation (CL-ODH) scheme. CL-ODH has the potential to significantly lower energy consumption and CO 2 /NO x emissions for ethylene production compared with conventional steam cracking. Sodium tungstate (Na 2 WO 4 ) was previously shown to be an effective promoter for Mg 6 MnO 8 -based redox catalysts. Overall, the CL-ODH reaction proceeds via parallel gas-phase cracking of ethane and selective combustion of H 2 on the surface of the Na 2 WO 4 -promoted redox catalyst. Reaction testing indicates that both Na and W are necessary to form Na 2 WO 4 and to achieve high ethylene selectivity. A Na:W ratio lower than 2:1 lead to significant formation of additional mixed tungsten oxide phases and decreases ethylene selectivity. Further characterizations based on low-energy ion scattering (LEIS) and differential scanning calorimetry (DSC) indicate that the NaW promoter forms a molten shell around the Mg6MnO8 redox catalyst. Methanol TPSR and in situ DRIFTS experiments indicate that the promoter significantly suppresses the number of basic sites on Mg 6 MnO 8 . 18 O– 16 O exchange experiments reveal that the promoter decreases the rate of oxygen exchange. O 2 cofeed studies indicate that below the melting temperature of Na 2 WO 4 , H 2 and CO conversions are both inhibited, but above the melting temperature, H 2 combustion significantly increased while CO combustion is still inhibited. On the basis of extensive characterizations, it was determined that H 2 is primarily combusted at the gas–Na 2 WO 4 molten shell interface via redox reactions of the tungsten salt, likely between the WO 4 2– (tungstate) and WO 3 – (tungsten bronze).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental investigations on sodium plugging in narrow flow channels.

A series of experiments was performed to investigate the potential for plugging of narrow flow channels of sodium by impurities (e.g., oxides). In the first phase of the experiments, clean sodium was circulated through the test sections simulating flow channels in a compact diffusion-bonded heat exchanger such as a printed circuit heat exchanger. The primary objective was to see if small channels whose cross sections are semicircles of 2, 4, and 6 mm in diameter are usable in liquid sodium applications where sodium purity is carefully controlled. It was concluded that the 2-mm channels, the smallest of the three, could be used in clean sodium systems at temperatures even as low as 100 to 110 C without plugging. In the second phase, sodium oxide was added to the loop, and the oxygen concentration in the liquid sodium was controlled by means of varying the cold-trap temperature. Intentional plugging was induced by creating a cold spot in the test sections, and the subsequent plugging behavior was observed. It was found that plugging in the 2-mm test section was initiated by lowering the cold spot temperature below the cold-trap temperature by 10 to 30 C. Unplugging of the plugged channels was accomplished by heating the affected test section.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Study of Compatibility of Stainless Steel Weld Joints with Liquid Sodium-Potassium Coolants for Fission Surface Power Reactors for Lunar and Space Applications

To make a manned mission to the surface of the moon or to Mars with any significant residence time, the power requirements will make a nuclear reactor the most feasible source of energy. To prepare for such a mission, NASA has teamed with the DOE to develop Fission Surface Power technology with the goal of developing viable options. The Fission Surface Power System (FSPS) recommended as the initial baseline design includes a liquid metal reactor and primary coolant system that transfers heat to two intermediate liquid metal heat transfer loops. Each intermediate loop transfers heat to two Stirling heat exchangers that each power two Stirling converters. Both the primary and the intermediate loops will use sodium-potassium (NaK) as the liquid metal coolant, and the primary loop will operate at temperatures exceeding 600°C. The alloy selected for the heat exchangers and piping is AISI Type 316L stainless steel. The extensive experience with NaK in breeder reactor programs and with earlier space reactors for unmanned missions lends considerable confidence in using NaK as a coolant in contact with stainless steel alloys. However, the microstructure, chemical segregation, and stress state of a weld leads to the potential for corrosion and cracking. Such failures have been experienced in NaK systems that have operated for times less than the eight year goal for the FSPS. For this reason, it was necessary to evaluate candidate weld techniques and expose welds to high-temperature, flowing NaK in a closed, closely controlled system. The goal of this project was to determine the optimum weld configuration for a NaK system that will withstand service for eight years under FSPS conditions. Since the most difficult weld to make and to evaluate is the tube to tube sheet weld in the intermediate heat exchangers, it was the focus of this research. A pumped loop of flowing NaK was fabricated for exposure of candidate weld specimens at temperatures of 600°C, the expected temperature within the intermediate heat exchangers. Since metal transfer from a high-temperature region to a cooler region is a predominant mode of corrosion in liquid metal systems, specimens were placed at zones in the loop at the above temperature to evaluate the effects of both alloy component leaching and metal deposition. Microstructural analysis was performed to evaluate weld performance on control weld specimens. The research was coordinated with Oak Ridge National Laboratory (ORNL) where most of the weld samples were prepared. In addition, ORNL participated in the loop operation to assist in keeping the testing relevant to the project and to take advantage of the extensive experience in liquid metal research at ORNL.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Method of generating hydrogen gas from sodium borohydride

A compact solid source of hydrogen gas, where the gas is generated by contacting water with micro-disperse particles of sodium borohydride in the presence of a catalyst, such as cobalt or ruthenium. The micro-disperse particles can have a substantially uniform diameter of 1-10 microns, and preferably about 3-5 microns. Ruthenium or cobalt catalytic nanoparticles can be incorporated in the micro-disperse particles of sodium borohydride, which allows a rapid and complete reaction to occur without the problems associated with caking and scaling of the surface by the reactant product sodium metaborate. A closed loop water management system can be used to recycle wastewater from a PEM fuel cell to supply water for reacting with the micro-disperse particles of sodium borohydride in a compact hydrogen gas generator. Capillary forces can wick water from a water reservoir into a packed bed of micro-disperse fuel particles, eliminating the need for using an active pump.

Kravitz, Stanley H↗

Method of Manufacturing Micro-Disperse Particles of Sodium Borohydride

A compact solid source of hydrogen gas, where the gas is generated by contacting water with micro-disperse particles of sodium borohydride in the presence of a catalyst, such as cobalt or ruthenium. The micro-disperse particles can have a substantially uniform diameter of 1-10 microns, and preferably about 3-5 microns. Ruthenium or cobalt catalytic nanoparticles can be incorporated in the micro-disperse particles of sodium borohydride, which allows a rapid and complete reaction to occur without the problems associated with caking and scaling of the surface by the reactant product sodium metaborate. A closed loop water management system can be used to recycle wastewater from a PEM fuel cell to supply water for reacting with the micro-disperse particles of sodium borohydride in a compact hydrogen gas generator. Capillary forces can wick water from a water reservoir into a packed bed of micro-disperse fuel particles, eliminating the need for using an active pump.

Kravitz, Stanley H↗

Using Calibrated Water Data for Preliminary Validation of the SRT Code for Advanced Reactors

Recent interest and corresponding progress worldwide regarding advanced nuclear reactors has renewed focus on their performance and related safety assessments. Specifically, the U.S. Nuclear Regulatory Commission has emphasized the importance of mechanistic approaches to source term analysis for advanced reactor licensing applications, which attempt to realistically account radionuclide transport and retention phenomena. Further model development is required due to the numerous and complex physical and chemical phenomena associated with mechanistic source term analyses. Reflecting the need for modeling advancement, Argonne National Laboratory developed a mechanistic source term analysis tool for sodium fast reactors. The Simplified Radionuclide Transport (SRT) code describes fuel pin failure (for simulating the initial condition at the point of fuel pin breach), bubble scrubbing, deposition, leakage and following environmental impact. In the current work, a validation study of the SRT bubble scrubbing model is performed using a water-loop experiment performed at the University of Wisconsin-Madison. Through the analysis, the approach and fundamental bubble scrubbing models in SRT, which examine the removal of aerosols within the bubble as it is transported through a pool, have been widely evaluated. The results of the assessment demonstrate a high level of agreement in the regions of greater aerosol size. In the parameter range of minimal aerosol removal, the simulation slightly underpredicts the experiment results; however, considering the scale of plots and huge uncertainties inherently included, the deviation can be judged to be minor and would produce a conservative result. In addition, uncertainty analysis has been further refined to reflect the experimental distribution of parameters including aerosol sizes, which induces a span of performance for each representative aerosol size. Based upon the initial validation results along with uncertainty effects, SRT is expected to provide meaningful insights for the analysis of bubble scrubbing. Future sodium-loop tests will provide further validation basis.

Kam, Dong Hoon↗

Modeling and Validation of Sodium Plugging for Heat Exchangers in Sodium-cooled Fast Reactor Systems

The project “Modeling and Validation of Sodium Plugging for Heat Exchangers in Sodium-cooled Fast Reactor Systems” was conducted jointly by Westinghouse Electric Company (Westinghouse) and Argonne National Laboratory (ANL), over the period October 1, 2013- March 31, 2016. The project’s motivation was the need to provide designers of Sodium Fast Reactors (SFRs) with a validated, state-of-the-art computational tool for the prediction of sodium oxide (Na 2 O) deposition in small-diameter sodium heat exchanger (HX) channels, such as those in the diffusion bonded HXs proposed for SFRs coupled with a supercritical CO 2 (sCO 2 ) Brayton cycle power conversion system. In SFRs, Na 2 O deposition can potentially occur following accidental air ingress in the intermediate heat transport system (IHTS) sodium and simultaneous failure of the IHTS sodium cold trap. In this scenario, oxygen can travel through the IHTS loop and reach the coldest regions, represented by the cold end of the sodium channels of the HXs, where Na 2 O precipitation may initiate and continue. In addition to deteriorating HX heat transfer and pressure drop performance, Na 2 O deposition can lead to channel plugging especially when the size of the sodium channels is small, which is the case for diffusion bonded HXs whose sodium channel hydraulic diameter is generally below 5 mm. Sodium oxide melts at a high temperature well above the sodium melting temperature such that removal of a solid plug such as through dissolution by pure sodium could take a lengthy time. The Sodium Plugging Phenomena Loop (SPPL) was developed at ANL, prior to this project, for investigating Na 2 O deposition phenomena within sodium channels that are prototypical of the diffusion bonded HX channels envisioned for SFR-sCO 2 systems. In this project, a Computational Fluid Dynamic (CFD) model capable of simulating the thermal-hydraulics of the SPPL test section and provided with Na 2 O deposition prediction capabilities, was developed. This state-of-the-art computational tool incorporates a first-principles Na 2 O deposition model developed by ANL, and combines it with predictive capabilities for the spatial and temporal variation of temperature, velocity, dissolved oxygen concentration, and wall temperature under flowing sodium conditions. The CFD model was validated under no-deposition conditions using experimental data collected with the SPPL, demonstrating the model’s capability to predict the thermal-hydraulics of the SPPL test section within the measurement uncertainty characterizing the SPPL instrumentation. The model’s deposition prediction capability was not, however, validated as the SPPL could not be operated under plugging conditions during the project, resulting in the lack of deposition data with adequate pedigree for a CFD model validation. Two novel diagnostic techniques to detect and characterize Na 2 O deposits, i.e. Ultrasonic Time Domain Reflectometry (UTDR) and Potential Drop (PD) techniques, were developed to ultimately assist in the validation effort under plugging conditions, which can be performed once the SPPL becomes operational. This development effort consisted first in demonstrating, analytically and/or computationally, the capability of these techniques to diagnose Na 2 O deposits inside of small channels (particularly the deposit’s thickness), and subsequently in the fabrication and testing of prototypical UTDR and PD instrumentation. The testing, performed on mockups of the SPPL test section, demonstrated the capability of these techniques to detect and characterize material discontinuities like those induced by sodium oxide deposition on stainless steel channel walls. Because of the mentioned impossibility to run the SPPL in a plugging mode, the developed instrumentation could not be tested in-situ, i.e. at the SPPL while deposits are being formed inside of the SPPL test section. Recommended future work includes a possible enhancement in the CFD modeling technique and installation of the developed UTDR and PD instrumentation on the test section, followed by plugging tests to be conducted with the SPPL. The installation of the UTDR and PD diagnostic instrumentation on the SPPL test section will allow collection of Na 2 O deposition data after the onset of deposition to nearly complete channel plugging, which can ultimately be used for the validation of the CFD model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Use of Long-wave Infrared Cameras for Hazardous Waste Remediation - 20457

For over fifty years, infrared cameras have been used in military applications, nondestructive testing, condition monitoring, and predictive maintenance. As infrared cameras continue to become more sophisticated and less expensive, they are providing value in an ever-increasing variety of unique applications, including hazardous waste remediation. This paper describes several instances of how infrared cameras have been used within the US Department of Defense and the US Department of Energy in support of waste remediation projects, including the author's recent use of an infrared camera in support of the Calcine Retrieval Project at the Idaho National Laboratory. Infrared cameras provide images of infrared radiation, or heat energy, which is otherwise invisible to the unaided eye. Infrared radiation is part of the electromagnetic spectrum, which includes visible light. But unlike visible light, infrared has wavelengths longer than the human eye can detect. Infrared is emitted by everything with a temperature above absolute zero (-273 deg. C, or -459 deg. F); the higher the temperature, the greater the infrared thermal radiation, or heat, that is emitted. Even objects that feel cold to us, like ice, emit thermal radiation and can be imaged by infrared cameras. These cameras are typically used to look for abnormally hot or cold spots on a component or target area under normal operating conditions. The method provides a rapid, wide-area, noncontact technique for identifying problems associated with a temperature differential. All infrared cameras can provide qualitative thermal information by displaying relative differences in temperatures within a two-dimensional image. More expensive infrared cameras can also provide quantitative information where an absolute temperature value is assigned to each pixel associated with the displayed two-dimensional image. Proper camera calibration and a solid understanding of heat transfer and thermography techniques are required when using an infrared camera to obtain quantitative information. Case studies outlined in this paper include the rapid, non-intrusive detection of hazardous decontamination solution within one-ton shipping containers at Pine Bluff Arsenal, the non-intrusive identification of residual elemental sodium within the cooling loops of the Experimental Breeder Reactor II (EBR-II) reactor at the Idaho National Laboratory, process monitoring of heat exchanger melt-and-drain efforts during EBR-II decommissioning, and the remote detection of internal steel supports within calcine storage bins prior to bin penetration. For each use of thermography, the author describes a summary of the waste remediation effort, the infrared camera used, the thermal imaging technique employed, and the results obtained. The paper concludes with a discussion on common mistakes to avoid for similar applications of thermography. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sample Testing Basket: Design and Capabilities Report

SFR designs all require integral components that can withstand prolonged submersion in the liquid sodium primary coolant as well as in the gas space of the reactor vessel. Materials are often desired to withstand these conditions for the lifetime of the reactor. The Sample Testing Basket (STB) was designed and fabricated to meet the anticipated need for material exposure testing in prototypic reactor coolant environments; in the liquid sodium primary coolant and the sodium-vapor-laden gas space. Developed at Argonne National Laboratory (ANL), the STB is a piece of equipment designed for use in the Mechanisms Engineering Test Loop (METL) to allow for sodium exposure testing of materials within the METL facility.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Temperature Sodium System Structural Health Monitoring (SHM) Technologies at the Mechanisms Engineering Test Loop (METL)

This report documents the deployment of non-destructive testing (NDT) technologies at the Mechanisms Engineering Test Loop (METL). METL became operational in September 2018 with the mission to provide an ecosystem for Advanced Reactor Development (ARD). METLs flagship facility’s primary purpose is conducting small to intermediate scale tests for Sodium Fast Reactors (SFR). Its resemblance to a commercial SFR’s intermediate heat transport system, prototypic operating conditions, and industrial construction practices/materials provides the overarching benefit of establishing a proving ground for devices of all technology readiness levels as well as commercial off-the-shelf equipment yet to be demonstrated on a sodium system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Capabilities development for transient testing of advanced nuclear fuels at TREAT

The TREAT facility is a unique capability at the Idaho National Laboratory currently being prepared for resumption of nuclear transient testing. TREAT is an air-cooled reactor where the driver core is made up of urania dispersed in graphite blocks and encapsulated in zirconium alloy cans. In addition to the reactor itself, the foundation for TREAT's capabilities will also include a suite of irradiation vehicles and supporting infrastructure to provide the desired specimen boundary conditions while supporting a variety of instrumentation needs. Although TREAT historically supported all kinds of nuclear fuels, including LWR's, SFR's, space nuclear propulsion, research reactor plate-type fuels, and even fuels for use in the driver core of other transient test reactors, the majority of TREAT's more-recent experiment programs revolved around SFR's and sodium-environment test capsules and loops. MK-series loop experiment-specific test trains could be outfitted with a variety of instruments to monitor test and specimen conditions while the fast neutron hodoscope collected information about fuel movement before, during, and after transient excursions. The SERTTA (Static Environment Rodlet Transient Test Apparatuses) devices will be general purpose vehicles capable of providing inert gas, water (up to PWR conditions), steam, or perhaps even molten sodium environments within vessel-like capsules. The Multi-SERTTA vehicle design is particularly novel as it makes use of the full active core length in TREAT to test four small rodlets (∼12 cm length), each within its own hermetic boundary, it will be capable of housing pre-irradiated fuel specimens. Additional modules and adaptations of Multi-SERTTA will enable rapid loop pressure blowdown to simulate LOCA conditions. The Super-SERTTA, akin to the Multi-SERTTA will offer more possibilities for simulating transient phenomena.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Report on Level Sensor Development

This report details the development of sensors capable of measuring the level of liquid sodium at the Mechanisms Engineering Test Loop (METL) of Argonne National Laboratory. A differential pressure level sensor and variations of a mutually inductive level sensor have been designed, built, and tested in sodium at METL. A differential pressure level sensor was successfully calibrated during the initial dump tank sodium fill and continues to operate effectively. A differential pressure level sensor has been procured for use in the expansion tank. Three variations of mutually inductive level sensors have been designed, built, and tested in an out-of-sodium testing station in Building 308. The most advanced variation consists of a coil wound mineral insulated cable capable of continuous level measurement of liquid sodium up to 538°C over a range of 70”. Successful in-sodium testing occurred in late 2018.

47 OTHER INSTRUMENTATION↗

Aqueous Corrosion Behavior of Cast CoCrFeMnNi Alloy

CoCrFeMnNi high-entropy alloy demonstrates good mechanical properties and can be further strengthened by thermomechanical processes. A sample alloy prepared by vacuum casting in a graphite mold was further investigated for its corrosion resistance. One-millimeter thin strips of cast alloy were used to investigate its corrosion behavior at room temperature. Linear potentiodynamic tests of the alloy in sodium chloride solution confirmed uniform corrosion property comparable to stainless steel AISI 304. However, a positive cyclic hysteresis loop indicated susceptibility to pitting corrosion. In sodium hydroxide solution, metastable pit formation was observed, while sulfuric acid solution passivated the alloy. In both cases, the alloy did not show any spontaneous pitting tendency.

36 MATERIALS SCIENCE↗

Testing and Simulation of an Updated Cartridge Loop Vehicle

The Versatile Test Reactor (VTR) is a sodium-cooled, fast-spectrum test reactor that is being developed in the United States and will support a variety of irradiation test vehicle configurations, including cartridge loops. This work includes out-of-pile experimental results from a single-phase, natural circulation cartridge loop vehicle with geometry relevant to VTR irradiation sites, as well as comparisons between the experimental results and results predicted using the TRAC/RELAP Advanced Computational Engine (TRACE) modeling tool. The experiments were conducted in the thermosyphon test loop (TSTL) facility at Oak Ridge National Laboratory. Comparisons are also made between the current experimental data and results from natural circulation experiments previously conducted in the TSTL in a cartridge vehicle that is similar in design but has smaller flow areas. This cartridge vehicle and the experimental program were developed to add to the single-phase, natural circulation data collected in the previous iteration of the cartridge loop design, which supports future irradiation experiments and adds to a database that is useful for validating computer models. Comparisons of experimental results to TRACE model predictions is a pertinent step in validating the computational tool for supporting future irradiation experiment design and safety calculations, and comparisons to previous cartridge loop results highlight the impact of the design changes made to the test vehicle. The experiments conducted include several steady state tests and transients, including power ramp, loss of offsite power, and loss of external flow scenarios. This work shows that TRACE can accurately predict temperatures and flow conditions in the cartridge loop and the updated vehicle design achieves higher mass flow rates at the same steady state power levels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗