Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Photon-photon opacity constraints for relativistically expanding gamma-ray burst sources

Five bright gamma-ray bursts (GRBs) detected by the Burst and Transient Source Experiment (BATSE) have also been detected at higher energies by EGRET. Four are consistent with power-law spectra extending to energies as high as, in the case of GRB930131, 1 GeV. The fifth, and most recent, GRB940217, has a more complex spectrum, with one photon detected at 18 GeV, the most energetic GRB photon detection to date. The optical depth to photon-photon pair production in these sources is extremely large for distances more than about 10pc away if the radiation is emitted isotropically in the observer's frame. This optical depth can be dramatically reduced if the source is moving with a relativstic bulk Lorentz factor Gamma, and recent calculations for this situation have been limited to cases of a beam with opening angle 1 Gamma, or expansions of infinitely thin spherical shells. This paper presents our extension of the pair production otpical depth calculation in relativistically expanding sources to more general geometries, including shells of finite thickness and arbitrary opening angle. We find that the minimum bulk Lorentz factors for the Energy Gamma Ray Experiment Telescope (EGRET) sources to be optically thin, i.e. display no spectral attenuation, is only moderately dependent on the shell thickness and its opening solid angle; these new limits on required velocity for given geometries will aid in placing realistic constraints on GRB source models.

Baring, M. G.↗

High resolution x-ray emission spectrometer for multiple hard x-ray emission lines: Demonstration for Cu Kα and Kβ emissions

In this work, we present a compact 3D printed x-ray emission spectrometer based on the von Hamos geometry that represents a significant upgrade to the existing von Hamos geometry-based miniature x-ray emission spectrometer (miniXES). The upgrades include the incorporation of a higher pixel density 500K detector for improved energy resolution and an enlarged sample area to accommodate a wider range of sample formats. The versatile spectrometer houses removable crystal holders that can be easily exchanged, as well as movable alignment eyelets that give flexibility in Bragg angle selection. Designed for ease of manufacture, all the components, except for the apertures, can be 3D printed and readily assembled. We describe its implementation in measurements of resonant and non-resonant Cu Kα and Kβ x-ray emission and report the theoretical and measured energy resolution and collected solid angle of the emission.

3D printing↗

Cerenkov counters for high energy nuclei: Some new developments

A method to determine with gas Cerenkov counters the Lorentz factor, gamma = E/mc, of cosmic ray nuclei with high accuracy over the range gamma approx. 20 to 100 is discussed. The measurement of the Cerenkov emission angle theta, by use of a suitable imaging system is considered. Imaging counters, the ring imaging Cerenkov counters (RICH), were developed for use on accelerators. The image of off-axis particles to determine the amount of image distortion as a function of the direction of the incoming nucleus is examined and an acceptance solid angle, relative to the optical axis, within which the nucleus produces an image with an acceptable level of distortion is defined. The properties of the image, which becomes elliptical, for off-axis particles are analyzed.

Swordy, S. P.↗

Cosmology Large Angular Scale Surveyor (CLASS): 90 GHz Telescope Pointing, Beam Profile, Window Function, and Polarization Performance

The Cosmology Large Angular Scale Surveyor (CLASS) is a telescope array that observes the cosmic microwave background (CMB) over ∼75% of the sky from the Atacama Desert, Chile, at frequency bands centered near 40, 90, 150, and 220 GHz. CLASS measures the large angular scale CMB polarization to constrain the tensor-to-scalar ratio and the optical depth to last scattering. This paper presents the optical characterization of the 90 GHz telescope. Observations of the Moon establish the pointing while dedicated observations of Jupiter are used for beam calibration. The standard deviations of the pointing error in azimuth, elevation, and boresight angle are 1$^{'}_.$3, 2$^{'}_.$1, and 2$^{'}_.$0, respectively, over the first 3 yr of observations. This corresponds to a pointing uncertainty ∼7% of the beam’s full width at half-maximum (FWHM). The effective azimuthally symmetrized instrument 1D beam estimated at 90 GHz has an FWHM of 0$^°_.$620 ± 0$^°_.$003 and a solid angle of 138.7 ± 0.6(stats.) ± 1.1(sys.) μsr integrated to a radius of 4°. The corresponding beam window function drops to $b^2_ℓ$ = 0.93, 0.71, 0.14 at ℓ = 30, 100, 300, respectively. Far-sidelobes are studied using detector-centered intensity maps of the Moon and measured to be at a level of 10 −3 or below relative to the peak. The polarization angle of Tau A estimated from preliminary survey maps is 149°.6 ± 0°.2(stats.) in equatorial coordinates. The instrumental temperature-to-polarization (T → P) leakage fraction, inferred from per-detector demodulated Jupiter scan data, has a monopole component at the level of 1.7 × 10 −3 , a dipole component with an amplitude of 4.3 × 10 −3 , with no evidence of quadrupolar leakage.

79 ASTRONOMY AND ASTROPHYSICS↗

Anisotropic inverse Compton emission

The angular distribution of the power and spectrum of Compton-scattered radiation in the case of an anisotropic distribution of soft photons is considered. Results obtained show that both the intensity and spectrum of the scattered radiation are a function of the Lorentz factor of the electrons, the geometry of the soft X-ray source and the viewing angle. The intensity of the hard X-rays scattered back into the bowl can be significantly greater (by a factor of up to 5.5) than that scattered toward the observer for an isotropic distribution of relativistic electrons at the center of a hemispherical bowl of soft X-ray emission. This factor is increased as the solid angle of the soft X-ray source subtended at the location of the electrons is reduced. The results obtained here have inmplications for models invoking a further 'reflection' of the resultant hard X-rays from the surface of a disk.

Ghisellini, G.↗

Air-kerma strength determination of a new directional {sup 103}Pd source

Purpose: A new directional {sup 103}Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing {sup 103}Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active {sup 103}Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S{sub K}) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S{sub K} to a well-type ionization chamber. Methods: S{sub K} measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S{sub K} from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S{sub K} with the presence of gold fluorescent energy lines. In addition to S{sub K} measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S{sub K} values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S{sub K} of four CivaDots with reproducibilities within 0.3%. Monte Carlo methods were used to calculate the UW VAFAC correction factors and the calculated spectrum emitted from a CivaDot was experimentally verified with HPGe detector measurements. The well-type ionization chamber showed minimal variation in response (<1.5%) as a function of source positioning angle, indicating that an American Association of Physicists in Medicine (AAPM) Accredited Dosimetry Calibration Laboratory calibrated well chamber would be a suitable device to transfer an S{sub K}-based calibration to a clinical user. S{sub K} per well-chamber ionization current ratios were consistent among the four dots measured. Additionally, the measurements and predictions of anisotropy show uniform emission within the solid angle of the VAFAC, which demonstrates the robustness of the S{sub K} measurement approach. Conclusions: This characterization of a new {sup 103}Pd directional brachytherapy source helps to establish calibration methods that could ultimately be used in the well-established AAPM Task Group 43 formalism. Monte Carlo methods accurately predict the changes in the energy spectrum caused by the fluorescent x-rays produced in the gold shield.

07 ISOTOPE AND RADIATION SOURCES↗

High-Performance X-ray Detection in a New Analytical Electron Microscope

X-ray detection by energy-dispersive spectrometry in the analytical electron microscope (AEM) is often limited by low collected X-ray intensity (P), modest peak-to-background (P/B) ratios, and limitations on total counting time (tau) due to specimen drift and contamination. A new AFM has been designed with maximization of P. P/B, and tau as the primary considerations. Maximization of P has been accomplished by employing a field-emission electron gun, X-ray detectors with high collection angles, high-speed beam blanking to allow only one photon into the detector at a time, and simultaneous collection from two detectors. P/B has been maximized by reducing extraneous background signals generated at the specimen holder, the polepieces and the detector collimator. The maximum practical tau has been increased by reducing specimen contamination and employing electronic drift correction. Performance improvments have been measured using the NIST standard Cr thin film. The 0-3 steradian solid angle of X-ray collection is the highest value available. The beam blanking scheme for X-ray detection provides 3-4 times greater throughput of X-rays at high count rates into a recorded spectrum than normal systems employing pulse-pileup rejection circuits. Simultaneous X-ray collection from two detectors allows the highest X-ray intensity yet recorded to be collected from the NIST Cr thin film. The measured P/B of 6300 is the highest level recorded for an AEM. In addition to collected X-ray intensity (cps/nA) and P/B measured on the standard Cr film, the product of these can be used as a figure-of-merit to evaluate instruments. Estimated minimum mass fraction (MMF) for Cr measured on the standard NIST Cr thin film is also proposed as a figure-of-merit for comparing X-ray detection in AEMs. Determinations here of the MMF of Cr detectable show at least a threefold improvement over previous instruments.

Lyman, C. E.↗

Evaluation of light emitting diode characteristics for a space-based plant irradiation source

Light emitting diodes (LEDs) are a promising irradiation source for plant growth in space. Improved semiconductor technology has yielded LED devices fabricated with gallium aluminum arsenide (GaAlAs) chips which have a high efficiency for converting electrical energy to photosynthetically active radiation. Specific GaAlAs LEDs are available that emit radiation with a peak wavelength near the spectral peak of maximum quantum action for photosynthesis. The electrical conversion efficiency of installed systems (μmol s -1 of photosynthetic photons per watt) of high output LEDs can be within 10% of that for high pressure sodium lamps. Output of individual LEDs were found to vary by as much as 55 % from the average of the lot. LED ratings, in mcd (luminous intensity per solid angle), were found to be proportional to total photon output only for devices with the same dispersion angle and spectral peak. Increasing current through the LED increased output but also increased temperature with a consequent decrease in electrical conversion efficiency. A photosynthetic photon flux as high as 900 μmol m -2 s -1 has been produced on surfaces using arrays with LEDs mounted 7.6 mm apart, operating at a current of 50 mA device -1 and at an installed density of approximately 17,200 lamps m -2 of irradiated area. Advantages of LEDs over other electric light sources for use in space systems include long life, minimal mass and volume and being a solid state device.

D J Barta↗

Absolute Calibration of the AXAF Telescope Effective Area

The prelaunch calibration of AXAF encompasses many aspects of the telescope. In principle, all that is needed is the complete point response function. This is, however, a function of energy, off-axis angle of the source, and operating mode of the facility. No single measurement would yield the entire result. Also, any calibration made prior to launch will be affected by changes in conditions after launch, such as the change from one g to zero g. The reflectivity of the mirror and perhaps even the detectors can change as well, for example by addition or removal of small amounts of material deposited on their surfaces. In this paper, we give a broad view of the issues in performing such a calibration, and discuss how they are being addressed in prelaunch preparation of AXAF. As our title indicates, we concentrate here on the total throughput of the observatory. This can be thought of as the integral of the point response function, i.e. the encircled energy, out ot the largest practical solid angle for an observation. Since there is no standard x-ray source in the sky whose flux is known to the -1% accuracy we are trying to achieve, we must do this calibration on the ground. we also must provide a means for monitoring any possible changes in this calibration from pre-launch until on-orbit operation can transfer the calibration to a celestial x-ray source whose emission is stable. In this paper, we analyze the elements of the absolute throughput calibration, which we call Effective Area. We review the requirements for calibrations of components or subsystems of the AXAF facility, including mirror, detectors, and gratings. We show how it is necessary to calibrate this ground-based detection system at standard man-made x-ray sources, such as electron storage rings. We present the status of all these calibrations, with indications of the measurements remaining to be done, even though the measurements on the AXAF flight optics and detectors will have been completed by the time this paper is presented. We evaluate progress toward the goal of making 1% measurements of the absolute x-ray flux from astrophysical sources, so that comparisons can be made with their emission at other wavelengths, in support of observations such as the Sunyaev-Zeldovitch effect, which can give absolute distance measurements independent of the traditional distance measuring techniques in astronomy.

Kellogg, E.↗

Effects of Size and Shape on the Tolerances for Misalignment and Probabilities for Successful Oriented Attachment of Nanoparticles

Oriented attachment (OA) of nanoparticles is an important pathway of crystal growth, but tools for quantitatively modeling OA are lacking. Here we present several simple models that relate the probability of achieving OA to basic geometric parameters such as particle size, shape, and lattice periodicity. A Moiré-domain model is applied to understand twist-misorientations between parallel surfaces, and it predicts that the range of twist angles yielding perfect OA is inversely related to the width of the contact area. This is confirmed and further developed using a surface functional model, which predicts how crystallographic registration forces drive the emergence of complex orientational energy landscapes. The energy landscapes are predicted to possess local minima that can trap particles in imperfect alignments, and these local minima become deeper and more numerous as the contact area increases, making OA more challenging for large particles. Further, a second set of models is presented to understand the sequence of events by which two crystallographic faces become co-planer after collision. We use a ‘central force approximation’ to quantitatively predict the odds of attaining coalignment between various faces when particles collide with random misalignments, and we show that in the absence of biasing forces, the probability of attaining alignment on a given face is roughly proportional to its solid angle as viewed from the center of the particle. The model predicts that OA is most favorable between well-faceted particles and becomes exceedingly unlikely for large spherical particles that express many microfacets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Grazing Incidence Optics for Neutron Imaging and Scattering

Because of their wave nature, thermal and cold neutrons can be reflected from smooth surfaces at grazing incidence angles, be reflected by multilayer coatings or be refracted at boundaries of different materials. The optical properties of materials are characterized by their refractive indices which are slightly less than unity for most elements and their isotopes in the case of cold and thermal neutrons as well as for x-rays. The motivation for the optics use for neutrons as well as for x-rays is to increase the signal rate and, by virtue of the optic's angular resolution, to improve the signal-to-noise level by reducing the background so the efficiency of the existing neutron sources use can be significantly enhanced. Both refractive and reflective optical techniques developed for x-ray applications can be applied to focus neutron beams. Typically neutron sources have lower brilliance compared to conventional x-ray sources so in order to increase the beam throughput the neutron optics has to be capable of capturing large solid angles. Because of this, the replicated optics techniques developed for x-ray astronomy applications would be a perfect match for neutron applications, so the electroformed nickel optics under development at the Marshall Space Flight Center (MSFC) can be applied to focus neutron beams. In this technique, nickel mirror shells are electroformed onto a figured and superpolished nickel-plated aluminum cylindrical mandrel from which they are later released by differential thermal contraction. Cylindrical mirrors with different diameters, but the same focal length, can be nested together to increase the system throughput. The throughput can be increased further with the use of the multilayer coatings deposited on the reflectivr surface of the mirror shells. While the electroformed nickel replication technique needs to be adopted for neutron focusing, the technology to coat the inside of cylindrical mirrors with neutron multilayers has to be developed. The availability of these technologies would bring new capabilities to neutron instrumentation and, hence, lead to new scientific breakthroughs. We have established a program to adopt the electroformed nickel replication optics technique for neutron applications and to develop the neutron multilayer replication technology.

Gubarev, M. V.↗

Multiplexed high resolution soft x-ray RIXS

High-resolution Resonance Inelastic X-ray Scattering (RIXS) is a technique that allows us to probe the electronic excitations of complex materials with unprecedented precision. However, the RIXS process has a low cross section, compounded by the fact that the optical spectrometers used to analyze the scattered photons can only collect a small solid angle and overall have a small efficiency. Here we present a method to significantly increase the throughput of RIXS systems, by energy multiplexing, so that a complete RIXS map of scattered intensity versus photon energy in and photon energy out can be recorded simultaneously{sup 1}. This parallel acquisition scheme should provide a gain in throughput of over 100.. A system based on this principle, QERLIN, is under construction at the Advanced Light Source (ALS).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Indigenous design and development of multiPSD array for time of flight neutron spectrometer

Time of Flight neutron Spectrometer for inelastic neutron scattering studies is being commissioned at Dhruva reactor. Neutron pulse tagging is carried out using the Fermi chopper. Scattered neutrons at maximum possible scattered solid angle are needed to be detected along with the time information at detector. Precise and efficient detection system is essential for measurement of spatial and temporal distribution. Detection area is optimized to cover an angle of 70° in horizontal direction and 23° in vertical direction. Position sensitive detectors (PSDs) are designed with judicial use of precious {sup 3}He gas and a few PSDs with BF{sub 3} gas as suitable alternative for {sup 3}He gas. An array of vertically arranged 1 m long, 50 PSDs, covers the arc length of 2.5 m and detection area 2.5 m{sup 2}. The design of the BF{sub 3} PSDs is supported by investigations on the gas purity, fill gas pressure, drift region, drift field and neutron absorption in cathode wall. Design details and performance of the PSDs are presented in the paper.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-Ray Absorbed, Broad-Lined, Red AGN and the Cosmic X-Ray Background

We have obtained XMM spectra for five red, 2MASS AGN, selected from a sample observed by Chandra to be X-ray bright and to cover a range of hardness ratios. Our results confirm the presence of substantial absorbing material in three sources which have optical classifications ranging from Type 1 to Type 2, with an intrinsically flat (hard) power law continuum indicated in the other two. The presence of both X-ray absorption and broad optical emission lines with the usual strength suggests either a small (nuclear) absorber or a favored viewing angle so as to cover the X-ray source but not the broad emission line region (BELR). A soft excess is detected in all three Type 1 sources. We speculate that this soft X-ray emission may arise in an extended region of ionized gas, perhaps linked with the polarized (scattered) light which is a feature of these sources. The spectral complexity revealed by XMM emphasizes the limitations of the low S/N Chandra data. Overall, the new XMM results strengthen our conclusions (Wilkes et al. 2002) that the observed X-ray continua of red AGN are unusually hard at energies greater than 2 keV. Whether due to substantial line-of-sight absorption or to an intrinsically hard or reflection-dominated spectrum, these 'red' AGN have an observed spectral form consistent with contributing significantly to the missing had absorbed population of the Cosmic X-ray Background (CXRB). When absorption and or reflection is taken into account, all these AGN have power law slopes typical of broad-line (Type 1) AGN (Gamma approximately 1.9). This appears to resolve the spectral paradox which for so long has existed between the CXRB and the AGN thought to be the dominant contributors. It also suggests two scenarios whereby Type 1 AGN/QSOs may be responsible for a significant fraction of the CXRB at energies above 2 keV: 1) X-ray absorbed AGN/QSOs with visible broad emission lines; 2) AGN/QSOs with complex spectra whose hardness greater than 2 keV is not detectable in the typically low S/N data of X-ray surveys. Even if absorption is present in only half of the population, the large number of 'red' AGN suggests a development of unification models, where the continuum source is surrounded, over a substantial solid angle, by the wind or atmosphere of an accretion disk/torus. X-ray observations of such AGN not only provide a check on the presence of absorption, but also a unique probe of the absorbing material. Improved information on their space density, in particular as a function of redshift, will soon be provided by Spitzer-Chandra wide area surveys, allowing better estimates of both the importance of red AGN to the full AGN population and their contribution to the CXRB.

Mushotzky, Richard↗

Color‐Stable, All‐Phosphorescent White Organic Light Emitting Diodes Using the Polariton‐Enhanced Purcell Effect

Abstract The short operational lifetimes of high efficiency phosphorescent organic blue light emitting devices (PHOLEDs) has limited their use in displays and lighting. Previously, this problem has been avoided by using less efficient fluorescent blue devices in separately biased red, green, and blue emissive elements to achieve stable full color emission. However, the operational lifetime of blue phosphorescent OLEDs has been significantly improved through the utilization of the plasmon‐exciton‐polariton‐enhanced (PEP) Purcell effect. Here, a white emitting PHOLED comprising stacked red, green, and blue elements is demonstrated that exploits PEPs to extend the operational lifetime of the blue element such that all emissive layers degrade at the same rate. The device features white light emission with an external quantum efficiency of 19.1 ± 0.4%, luminous power efficiency of 13.3 ± 0.3 lm W −1 at a luminance of 1000 cd m −2 when measured over 4π solid angle, with a color rendering index of 76 unchanged throughout the device aging to 70% of its initial luminance, T 70 . A 2.9 times enhancement in the operational lifetime of the Purcell‐enhanced device is achieved to yield T 70 = 2900 ± 100 h for an initial luminance of 1000 cd m −2 , compared to devices lacking this enhancement with T 70 = 1000 ± 100 h.

36 MATERIALS SCIENCE↗

Investigation of the Branching of Solutions of the Problems of Synthesis of Radiating Systems with Flat Aperture According to a Given Amplitude Directivity Pattern

We continue our investigation of the nonuniqueness of solutions in the problems of synthesis of radiating systems with flat apertures depending on two parameters characterizing the size of the aperture and the solid angle in which the required amplitude directivity pattern is defined. The existence and properties of the real (primary) solutions of four types are clarified. We study the problems of branching of primary solutions of the second type. In the first approximation, we determine the analytic representations of complex-valued solutions branched from a real solution and investigate their main properties. The numerical experiments are carried out to analyze the efficiency of real and branched complexvalued solutions.

97 MATHEMATICS AND COMPUTING↗

A non-singular theory of dislocations in anisotropic crystals

Here we develop a non-singular theory of three-dimensional dislocation loops in a particular version of Mindlin's anisotropic gradient elasticity with up to six length scale parameters. The theory is systematically developed as a generalization of the classical anisotropic theory in the framework of linearized incompatible elasticity. The non-singular version of all key equations of anisotropic dislocation theory are derived as line integrals, including the Burgers displacement equation with isolated solid angle, the Peach-Koehler stress equation, the Mura-Willis equation for the elastic distortion, and the Peach-Koehler force. The expression for the interaction energy between two dislocation loops as a double line integral is obtained directly, without the use of a stress function. It is shown that all the elastic fields are non-singular, and that they converge to their classical counterparts a few characteristic lengths away from the dislocation core. In practice, the non-singular fields can be obtained from the classical ones by replacing the classical (singular) anisotropic Green's tensor with the non-singular anisotropic Green's tensor derived by Lazar and Po (2015b). The elastic solution is valid for arbitrary anisotropic media. In addition to the classical anisotropic elastic constants, the non-singular Green's tensor depends on a second order symmetric tensor of length scale parameters modeling a weak non-locality, whose structure depends on the specific class of crystal symmetry. The anisotropic Helmholtz operator defined by such tensor admits a Green's function which is used as the spreading function for the Burgers vector density. As a consequence, the Burgers vector density spreads differently in different crystal structures. Two methods are proposed to determine the tensor of length scale parameters, based on independent atomistic calculations of classical and gradient elastic constants. The anisotropic non-singular theory is shown to be in good agreement with molecular statics without fitting parameters, and unlike its singular counterpart, the sign of stress components does not show reversal as the core is approached. Compared to the isotropic solution, the difference in the energy density per unit length between edge and screw dislocations is more pronounced.

42 ENGINEERING↗

CHICO2, a two-dimensional pixelated parallel-plate avalanche counter

CHICO 2 (Compact Heavy Ion COunter), is a large solid-angle, charged-particle detector array developed to provide both θ and Φ angle resolutions matching those of GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array). CHICO 2 was successfully tested at the Argonne National Laboratory where it was fielded as an auxiliary detector with GRETINA for γ-ray spectroscopic studies of nuclei using a 252 Cf spontaneous fission source, stable beams, and radioactive beams from CARIBU. In field tests of the 72,76Ge beams on a 0.5 mg/cm 2 208Pb target at the sub-barrier energy, CHICO 2 provided charged-particle angle resolutions (FWHM) of 1.55° in θ and 2.47° in Φ. This achieves the design goal for both coordinates assuming a beam-spot size (>3 mm) and the target thickness (>0.5 mg/cm 2 ). The combined angular resolution of GRETINA/CHICO 2 resulted in a Doppler-shift corrected energy resolution of 0.60% for 1 MeV coincident de-excitation γ-rays. This is nearly a factor of two improvements in resolution and sensitivity compared to Gammasphere/CHICO. Kinematically-coincident detection of scattered ions by CHICO 2 still maintains the mass resolution (ΔM/M) of ~5% that enhanced isolation of scattered weak beams of interest from scattered contaminant beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗