Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solid angle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Glassy carbon as an absolute intensity calibration standard for small-angle scattering.

Absolute calibration of small-angle scattering (SAS) intensity data (measured in terms of the differential scattering cross section per unit sample volume per unit solid angle) is essential for many important aspects of quantitative SAS analysis, such as obtaining the number density, volume fraction, and specific surface area of the scatterers. It also enables scattering data from different instruments (light, X-ray, or neutron scattering) to be combined, and it can even be useful to detect the existence of artifacts in the experimental data. Different primary or secondary calibration methods are available. In the latter case, absolute intensity calibration requires a stable artifact with the necessary scattering profile. Glassy carbon has sometimes been selected as this intensity calibration standard. Here we review the spatial homogeneity and temporal stability of one type of commercially available glassy carbon that is being used as an intensity calibration standard at a number of SAS facilities. We demonstrate that glassy carbon is sufficiently homogeneous and stable during routine use to be relied upon as a suitable standard for absolute intensity calibration of SAS data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New constraints on the escape of ionizing photons from starburst galaxies using ionization-parameter mapping

The fate of ionizing radiation in starburst galaxies is key to understanding cosmic reionization. However, the galactic parameters on which the escape fraction of ionizing radiation depend are not well understood. Ionization-parameter mapping provides a simple, yet effective, way to study the radiative transfer in starburst galaxies. We obtain emission-line ratio maps of [S III]/[S II] for six, nearby, dwarf starbursts: NGC 178, NGC 1482, NGC 1705, NGC 3125, NGC 7126, and He 2-10. The narrowband images are obtained with the Maryland-Magellan Tunable Filter at Las Campanas Observatory. Using these data, we previously reported the discovery of an optically thin ionization cone in NGC 5253, and here we also discover a similar ionization cone in NGC 3125. This latter cone has an opening angle of 40° ± 5° (0.4 sr), indicating that the passageways through which ionizing radiation may travel correspond to a small solid angle. Additionally, there are three sample galaxies that have winds and/or superbubble activity, which should be conducive to escaping radiation, yet they are optically thick. These results support the scenario that an orientation bias limits our ability to directly detect escaping Lyman continuum in many starburst galaxies. A comparison of the star formation properties and histories of the optically thin and thick galaxies is consistent with the model that high escape fractions are limited to galaxies that are old enough (≳3 Myr) for mechanical feedback to have cleared optically thin passageways in the interstellar medium, but young enough (≲5 Myr) that the ionizing stars are still present.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of ANGLE(R), a code for calculating HPGe detector efficiencies

This paper evaluates the ANGLE(reg sign) software package, an advanced efficiency calibration software for high purity germanium detectors that is distributed by ORTEC(reg sign). ANGLE(reg sign) uses a semi-empirical approach, by way of the efficiency transfer method, based on the calculated effective solid angle. This approach would have an advantage over the traditional relative and stochastic methods by decreasing the chances for systematic errors and reducing sensitivity to uncertainties in detector parameters. For experimental confirmation, a closed-end coaxial HPGe detector was used with sample geometries frequently encountered at the Los Alamos National Laboratory. The results obtained were sufficient for detector-source configurations which included intercepting layers of plexiglass and carbon graphite, but somewhat insufficient for bare source configurations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Search For Excited Cascade Hypersons (¿*-) Using the CLAS12 Spectrometer at Jefferson Laboratory

The number of experimentally observed doubly strange Cascade states to date is far fewer than has been predicted theoretically. The CLAS12 Very Strange physics program (E12- 11-005A) at the Thomas Jefferson National Accelerator Facility aims to study the electroproduction of these states using the newly upgraded CEBAF Large Acceptance Spectrometer for 12 GeV (CLAS12) in experimental Hall B. In this project, the reaction ep ! e0K+K+??? ! e0K+K+K?(?=?0) is studied using CLAS12 Run Group A (RG-A) data sets taken by impinging electron beams of 10:2 and 10:6 GeV energies on an LH2 target. Scattered electrons are detected with either the Forward Detector (FD), covering a polar angle range of 5? to 35? to study electroproduction, or with the Forward Tagger (FT), covering a polar angle range of 2:5? to 4:5?, to study quasi-real photoproduction. The CLAS12 detector with nearly a 4? solid angle coverage is used to detect scattered electrons and charged kaons in the ?final state. ?=?0 hyperons are reconstructed using the missing mass technique to explore intermediate doubly-strange hyperons (???) that decay to K? and ?=?0. No statistically significant ??? states other than the ???(1530) were found in the missing mass spectra based on the currently available statistics in the CLAS12-FD acceptance only. A maximum log-likelihood method is implemented to determine the statistical significance and the upper limits on the ???(1820) electroproduction cross section by constructing 95% confidence level boundaries on the ???(1820) yields. Additional research was conducted to investigate the upper limit electroproduction cross section of the reaction ep ! e0K+K+??? ! e0K+K+K?(?=?0) as a function of the electroproduced ??? mass and the differential cross section ( d?dMM(e0K+K+) ) as a function of missing mass MM(e0K+K+) for electroproduction and quasi-real photoproduction processes.

Khanal, Achyut↗

An ultra-high gain and efficient amplifier based on Raman amplification in plasma

Raman amplification arising from the excitation of a density echelon in plasma could lead to amplifiers that significantly exceed current power limits of conventional laser media. Here we show that 1–100 J pump pulses can amplify picojoule seed pulses to nearly joule level. The extremely high gain also leads to significant amplification of backscattered radiation from “noise”, arising from stochastic plasma fluctuations that competes with externally injected seed pulses, which are amplified to similar levels at the highest pump energies. The pump energy is scattered into the seed at an oblique angle with 14 J sr -1 , and net gains of more than eight orders of magnitude. The maximum gain coefficient, of 180 cm -1 , exceeds high-power solid-state amplifying media by orders of magnitude. The observation of a minimum of 640 J sr -1 directly backscattered from noise, corresponding to ≈10% of the pump energy in the observation solid angle, implies potential overall efficiencies greater than 10%.

42 ENGINEERING↗

Application of multi-angle scattering maps to stepped surfaces

This study examines channeling, multiple scattering, and neutralization/re-ionization of ions scattered along the stepped Al(332) plane. Our experimental approach involves probing the surface with 1–2 keV He + and Ne + beams, and then systematically mapping the scattered ion fluxes over a large solid angle. This provides comprehensive ion channeling information over all directions, rather than along a few low-index azimuths, as is common practice in ion scattering spectroscopy. We first probe the surface with 2 keV He + at near-normal incidence, and then map the backscattered particle flux (both ions and neutrals) via time of flight (TOF) spectrometry. The features contained in these maps can be correlated with axial and inter-planar channeling effects, and are reproduced well via binary collision simulations. Sensitivity to the stepped surface topography is heightened considerably for oblique ion incidence in the forward-scattering direction. In this geometry, we used 2 keV Ne + to probe the surface and mapped the corresponding scattered fluxes of both single and multiply-charged ions. In both cases, the scattering intensity depends strongly on the precise trajectory taken along the surface, and is particularly sensitive to how extensively the incident ions interact with the step edges. We interpret the information contained in these maps by considering several mechanisms for charge transfer and double ion production. The formation of Ne ++ appears to be correlated with a previously observed inelastic mechanism that occurs when the collision apsis, R min , is less than 0.65 Å. In conclusion, this contributes to an energy loss of 48 ± 8 eV for Ne + undergoing single scattering; the R min threshold for this inelastic step coincides with the emergence of a distinct Ne ++ peak. Using the information gained from the maps, we propose methods for extending this approach to chemisorbed layers.

47 OTHER INSTRUMENTATION↗

High sensitivity boron quantification in bulk silicon using the {sup 11}B(p,{alpha}{sub 0}){sup 8}Be nuclear reaction

There is a great need to quantify sub-ppm levels of boron in bulk silicon. There are several methods to analyze B in Si: Nuclear Reaction Analysis using the {sup 11}B(p,{alpha}{sub 0}){sup 8}Be reaction exhibits a quantification limit of some hundreds ppm of B in Si. Heavy Ion Elastic Recoil Detection Analysis offers a detection limit of 5 to 10 at. ppm. Secondary Ion Mass Spectrometry is the method of choice of the semiconductor industry for the analysis of B in Si. This work verifies the use of NRA to quantify B in Si, and the corresponding detection limits. Proton beam with 1.6 up to 2.6 MeV was used to obtain the cross-section of the {sup 11}B(p,{alpha}{sub 0}){sup 8}Be nuclear reaction at 170 Degree-Sign scattering angle. The results show good agreementwith literature indicating that the quantification of boron in silicon can be achieved at 100 ppm level (high sensitivity) at LAMFI-IFUSP with about 16% uncertainty. Increasing the detection solid angle and the collected beam charge, can reduce the detection limit to less than 100 ppm meeting present technological needs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A robust derivation of the tight relationship of radio core dominance to inclination angle in high redshift 3CRR sources

It is believed that, in radio-loud active galactic nuclei (AGNs), the core radio flux density can be normalized to the flux density of the extended lobe emission to infer the orientation of a radio source. However, very little is known about the reliability and precision of this method, and we are unaware of any robust conversion recipe to infer the inclination from the core dominance. Investigating whether or not the radio core dominance parameter R separates the quasars from the radio galaxies in the z ⩾ 1 3CRR catalog, we found excellent agreement of R with optical type, infrared flux ratios, and optical polarization. This indicates that probably both R and optical classification are very good orientation indicators, and the unified model is strongly predictive for these objects. The relative number densities indicate half-opening angles close to 60°, as expected from large surveys. The separations of optical types according to radio core dominance as well as near-infrared/MIR ratios, which are essentially perfect, mean that there can be only a small dispersion of torus half-opening angles. Also, even though torus dust is thought to be clumpy, there is an almost zero probability to see a type-1 source at high inclination. Finally, using only the Copernican Principle, i.e., the assumption that solid angle is filled uniformly with source axis orientations, we estimated a semi-empirical relation between core dominance and AGN inclination. This makes it possible to use R to infer the inclination of a source to an accuracy of ∼10° or less, at least for this type of object.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated protein resonance assignments of magic angle spinning solid-state NMR spectra of β1 immunoglobulin binding domain of protein G (GB1)

Magic-angle spinning solid-state NMR (MAS SSNMR) represents a fast developing experimental technique with great potential to provide structural and dynamics information for proteins not amenable to other methods. However, few automated analysis tools are currently available for MAS SSNMR. We present a methodology for automating protein resonance assignments of MAS SSNMR spectral data and its application to experimental peak lists of the b1 immunoglobulin binding domain of protein G (GB1) derived from a uniformly 13 C- and 15 N-labeled sample. This application to the 56 amino acid GB1 produced an overall 84.1% assignment of the N, CO, CA, and CB resonances with no errors using peak lists from NCACX 3D, CANcoCA 3D, and CANCOCX 4D experiments. This proof of concept demonstrates the tractability of this problem.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High resolution x-ray emission spectrometer for multiple hard x-ray emission lines: Demonstration for Cu Kα and Kβ emissions

In this work, we present a compact 3D printed x-ray emission spectrometer based on the von Hamos geometry that represents a significant upgrade to the existing von Hamos geometry-based miniature x-ray emission spectrometer (miniXES). The upgrades include the incorporation of a higher pixel density 500K detector for improved energy resolution and an enlarged sample area to accommodate a wider range of sample formats. The versatile spectrometer houses removable crystal holders that can be easily exchanged, as well as movable alignment eyelets that give flexibility in Bragg angle selection. Designed for ease of manufacture, all the components, except for the apertures, can be 3D printed and readily assembled. We describe its implementation in measurements of resonant and non-resonant Cu Kα and Kβ x-ray emission and report the theoretical and measured energy resolution and collected solid angle of the emission.

3D printing↗

Cosmology Large Angular Scale Surveyor (CLASS): 90 GHz Telescope Pointing, Beam Profile, Window Function, and Polarization Performance

The Cosmology Large Angular Scale Surveyor (CLASS) is a telescope array that observes the cosmic microwave background (CMB) over ∼75% of the sky from the Atacama Desert, Chile, at frequency bands centered near 40, 90, 150, and 220 GHz. CLASS measures the large angular scale CMB polarization to constrain the tensor-to-scalar ratio and the optical depth to last scattering. This paper presents the optical characterization of the 90 GHz telescope. Observations of the Moon establish the pointing while dedicated observations of Jupiter are used for beam calibration. The standard deviations of the pointing error in azimuth, elevation, and boresight angle are 1$^{'}_.$3, 2$^{'}_.$1, and 2$^{'}_.$0, respectively, over the first 3 yr of observations. This corresponds to a pointing uncertainty ∼7% of the beam’s full width at half-maximum (FWHM). The effective azimuthally symmetrized instrument 1D beam estimated at 90 GHz has an FWHM of 0$^°_.$620 ± 0$^°_.$003 and a solid angle of 138.7 ± 0.6(stats.) ± 1.1(sys.) μsr integrated to a radius of 4°. The corresponding beam window function drops to $b^2_ℓ$ = 0.93, 0.71, 0.14 at ℓ = 30, 100, 300, respectively. Far-sidelobes are studied using detector-centered intensity maps of the Moon and measured to be at a level of 10 −3 or below relative to the peak. The polarization angle of Tau A estimated from preliminary survey maps is 149°.6 ± 0°.2(stats.) in equatorial coordinates. The instrumental temperature-to-polarization (T → P) leakage fraction, inferred from per-detector demodulated Jupiter scan data, has a monopole component at the level of 1.7 × 10 −3 , a dipole component with an amplitude of 4.3 × 10 −3 , with no evidence of quadrupolar leakage.

79 ASTRONOMY AND ASTROPHYSICS↗

A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model

Purpose: The model S700 Axxent electronic brachytherapy source by Xoft, Inc., was characterized by Rivard et al. in 2006. Since then, the source design was modified to include a new insert at the source tip. Current study objectives were to establish an accurate source model for simulation purposes, dosimetrically characterize the new source and obtain its TG-43 brachytherapy dosimetry parameters, and determine dose differences between the original simulation model and the current model S700 source design. Methods: Design information from measurements of dissected model S700 sources and from vendor-supplied CAD drawings was used to aid establishment of an updated Monte Carlo source model, which included the complex-shaped plastic source-centering insert intended to promote water flow for cooling the source anode. These data were used to create a model for subsequent radiation transport simulations in a water phantom. Compared to the 2006 simulation geometry, the influence of volume averaging close to the source was substantially reduced. A track-length estimator was used to evaluate collision kerma as a function of radial distance and polar angle for determination of TG-43 dosimetry parameters. Results for the 50 kV source were determined every 0.1 cm from 0.3 to 15 cm and every 1° from 0° to 180°. Photon spectra in water with 0.1 keV resolution were also obtained from 0.5 to 15 cm and polar angles from 0° to 165°. Simulations were run for 10{sup 10} histories, resulting in statistical uncertainties on the transverse plane of 0.04% at r = 1 cm and 0.06% at r = 5 cm. Results: The dose-rate distribution ratio for the model S700 source as compared to the 2006 model exceeded unity by more than 5% for roughly one quarter of the solid angle surrounding the source, i.e., θ ≥ 120°. The radial dose function diminished in a similar manner as for an {sup 125}I seed, with values of 1.434, 0.636, 0.283, and 0.0975 at 0.5, 2, 5, and 10 cm, respectively. The radial dose function ratio between the current and the 2006 model had a minimum of 0.980 at 0.4 cm, close to the source sheath and for large distances approached 1.014. 2D anisotropy function ratios were close to unity for 50° ≤ θ ≤ 110°, but exceeded 5% for θ < 40° at close distances to the sheath and exceeded 15% for θ > 140°, even at large distances. Photon energy fluence of the updated model as compared to the 2006 model showed a decrease in output with increasing distance; this effect was pronounced at the lowest energies. A decrease in photon fluence with increase in polar angle was also observed and was attributed to the silver epoxy component. Conclusions: Changes in source design influenced the overall dose rate and distribution by more than 2% in several regions. This discrepancy is greater than the dose calculation acceptance criteria as recommended in the AAPM TG-56 report. The effect of the design change on the TG-43 parameters would likely not result in dose differences outside of patient applicators. Adoption of this new dataset is suggested for accurate depiction of model S700 source dose distributions.

60 APPLIED LIFE SCIENCES↗

Air-kerma strength determination of a new directional {sup 103}Pd source

Purpose: A new directional {sup 103}Pd planar source array called a CivaSheet™ has been developed by CivaTech Oncology, Inc., for potential use in low-dose-rate (LDR) brachytherapy treatments. The array consists of multiple individual polymer capsules called CivaDots, containing {sup 103}Pd and a gold shield that attenuates the radiation on one side, thus defining a hot and cold side. This novel source requires new methods to establish a source strength metric. The presence of gold material in such close proximity to the active {sup 103}Pd region causes the source spectrum to be significantly different than the energy spectra of seeds normally used in LDR brachytherapy treatments. In this investigation, the authors perform air-kerma strength (S{sub K}) measurements, develop new correction factors for these measurements based on an experimentally verified energy spectrum, and test the robustness of transferring S{sub K} to a well-type ionization chamber. Methods: S{sub K} measurements were performed with the variable-aperture free-air chamber (VAFAC) at the University of Wisconsin Medical Radiation Research Center. Subsequent measurements were then performed in a well-type ionization chamber. To realize the quantity S{sub K} from a directional source with gold material present, new methods and correction factors were considered. Updated correction factors were calculated using the MCNP 6 Monte Carlo code in order to determine S{sub K} with the presence of gold fluorescent energy lines. In addition to S{sub K} measurements, a low-energy high-purity germanium (HPGe) detector was used to experimentally verify the calculated spectrum, a sodium iodide (NaI) scintillating counter was used to verify the azimuthal and polar anisotropy, and a well-type ionization chamber was used to test the feasibility of disseminating S{sub K} values for a directional source within a cylindrically symmetric measurement volume. Results: The UW VAFAC was successfully used to measure the S{sub K} of four CivaDots with reproducibilities within 0.3%. Monte Carlo methods were used to calculate the UW VAFAC correction factors and the calculated spectrum emitted from a CivaDot was experimentally verified with HPGe detector measurements. The well-type ionization chamber showed minimal variation in response (<1.5%) as a function of source positioning angle, indicating that an American Association of Physicists in Medicine (AAPM) Accredited Dosimetry Calibration Laboratory calibrated well chamber would be a suitable device to transfer an S{sub K}-based calibration to a clinical user. S{sub K} per well-chamber ionization current ratios were consistent among the four dots measured. Additionally, the measurements and predictions of anisotropy show uniform emission within the solid angle of the VAFAC, which demonstrates the robustness of the S{sub K} measurement approach. Conclusions: This characterization of a new {sup 103}Pd directional brachytherapy source helps to establish calibration methods that could ultimately be used in the well-established AAPM Task Group 43 formalism. Monte Carlo methods accurately predict the changes in the energy spectrum caused by the fluorescent x-rays produced in the gold shield.

07 ISOTOPE AND RADIATION SOURCES↗

Zero sound in dipolar Fermi gases

We study the propagation of sound in a homogeneous dipolar gas at zero temperature, which is known as zero sound. We find that undamped zero sound propagation is possible only in a range of solid angles around the direction of polarization of the dipoles. Above a critical dipole moment, we find an unstable mode, by which the gas collapses locally perpendicular to the dipoles' direction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cascaded two-photon spectroscopy of Yb atoms with a transportable effusive atomic beam apparatus

We present a transportable effusive atomic beam apparatus for cascaded two-photon spectroscopy of the dipole-forbidden transition (6s{sup 2} {sup 1}S{sub 0}{r_reversible} 6s7s {sup 1}S{sub 0}) of Yb atoms. An ohmic-heating effusive oven is designed to have a reservoir volume of 1.6 cm{sup 3} and a high degree of atomic beam collimation angle of 30 mrad. The new atomic beam apparatus allows us to detect the spontaneously cascaded two-photons from the 6s7s{sup 1}S{sub 0} state via the intercombination 6s6p{sup 3}P{sub 1} state with a high signal-to-noise ratio even at the temperature of 340 Degree-Sign C. This is made possible in our apparatus because of the enhanced atomic beam flux and superior detection solid angle.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Instrument development continues in Oak Ridge

Peer review panels composed of 80 external scientists recently visited Oak Ridge National Laboratory (ORNL) to review almost 700 proposals for experiments on 23 instruments at the Spallation Neutron Source (SNS) and High Flux Isotope Reactor (HFIR). These were proposed for the time period from January-June 2012. About 40% of the proposals were approved for beam time and 20% were placed on an alternate list if time becomes available. The Hybrid Spectrometer HYSPEC at SNS began its commissioning in September 2011. HYSPEC is otpimized for studying low energy dynamics in single-crystal samples using a broad variety of sample environments, and is equipped with a polarization analysis capability. It is expected to be available for users on a limited basis in the second half of 2012. The detector tank of CORELLI has been installed on beamline 9 at SNS. Now that the tank is in place, banks of neutron detectors and boron carbide shielding will be installed around the interior. CORELLI is optimized to probe complex disorder in crystalline materials through diffuse scattering from single-crystal samples. It will begin commissioning in 2014. CORELLI is one of four instruments being developed under the SING II (SNS Instruments Next Generation II) project. The others are the Macromolecular Neutron Diffractometer (MANDI), the Vibrational Spectrometer (VISION, scheduled to begin commissioning in 2012), and the Time of Flight Ultra Small Angle Neutron Scattering Instrument (TOF-USANS). The single crystal neutron diffractometer IMAGINE, was deliverd to HFIR in October 2011. Preliminary testing has been carried out. IMAGINE will provide atomic resolution information on chemical, organic, metallo-organic and protein single crystals that will enable their chemical, physical and biological structure and function to be understood. This instrument will benefit scientists with interests in pharmaceuticals, minerals and other inorganic crystals, small molecules, molecular organo-metallic crystals and metal-organic frameworks (MOFs) molecular crystal structures. The quasi-Laue geometry, combined with a large solid angle detector, will enable rapid data collection from crystals with volume < 1mm{sup 1} and unit cell < 100 {angstrom}. Construction and installation of the optical system is in progress. Commissioning is expected to start in April 2012.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SELECTION EFFECTS ON THE OBSERVED REDSHIFT DEPENDENCE OF GAMMA-RAY BURST JET OPENING ANGLES

An apparent redshift dependence of the jet opening angles ({theta}{sub j}) of gamma-ray bursts (GRBs) is observed from the current GRB sample. We investigate whether this dependence can be explained with instrumental selection effects and observational biases by a bootstrapping method. Assuming that (1) the GRB rate follows the star formation history and the cosmic metallicity history and (2) the intrinsic distributions of the jet-corrected luminosity (L{sub {gamma}}) and {theta}{sub j} are a Gaussian or a power-law function, we generate a mock Swift/Burst Alert Telescope (BAT) sample by considering various instrumental selection effects, including the flux threshold and the trigger probability of BAT, the probabilities of a GRB jet pointing to the instrument solid angle, and the probability of redshift measurement. Our results reproduce the observed {theta}{sub j} - z dependence well. We find that in the case of L{sub {gamma}}{proportional_to}{theta}{sup 2}{sub j} good consistency between the mock and observed samples can be obtained, indicating that both L{sub {gamma}} and {theta}{sub j} are degenerate for a flux-limited sample. The parameter set (L{sub {gamma}}, {theta}{sub j}) = (4.9 Multiplication-Sign 10{sup 49} erg s{sup -1}, 0.054 rad) gives the best consistency for the current Swift GRB sample. Considering the beaming effect, the derived intrinsic local GRB rate is accordingly 2.85 Multiplication-Sign 10{sup 2} Gpc{sup -3} yr{sup -1}, inferring that {approx}0.59% of Type Ib/c supernovae may be accompanied by a GRB.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-284: Revisiting Reference Dosimetry for the Model S700 Axxent 50 KV{sub p} Electronic Brachytherapy Source

Purpose: The model S700 Axxent electronic brachytherapy source by Xoft was characterized in 2006 by Rivard et al. The source design was modified in 2006 to include a plastic centering insert at the source tip to more accurately position the anode. The objectives of the current study were to establish an accurate Monte Carlo source model for simulation purposes, to dosimetrically characterize the new source and obtain its TG-43 brachytherapy dosimetry parameters, and to determine dose differences between the source with and without the centering insert. Methods: Design information from dissected sources and vendor-supplied CAD drawings were used to devise the source model for radiation transport simulations of dose distributions in a water phantom. Collision kerma was estimated as a function of radial distance, r, and polar angle, θ, for determination of reference TG-43 dosimetry parameters. Simulations were run for 10{sup 10} histories, resulting in statistical uncertainties on the transverse plane of 0.03% at r=1 cm and 0.08% at r=10 cm. Results: The dose rate distribution the transverse plane did not change beyond 2% between the 2006 model and the current study. While differences exceeding 15% were observed near the source distal tip, these diminished to within 2% for r>1.5 cm. Differences exceeding a factor of two were observed near θ=150° and in contact with the source, but diminished to within 20% at r=10 cm. Conclusions: Changes in source design influenced the overall dose rate and distribution by more than 2% over a third of the available solid angle external from the source. For clinical applications using balloons or applicators with tissue located within 5 cm from the source, dose differences exceeding 2% were observed only for θ>110°. This study carefully examined the current source geometry and presents a modern reference TG-43 dosimetry dataset for the model S700 source.

60 APPLIED LIFE SCIENCES↗