Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

(U) A General-Purpose Code for Correlated Sampling Using Batch Statistics with MCNP6 for Fixed-Source Problems

Correlated sampling can be used to reduce the uncertainty of a difference of tallies by taking advantage of the negative covariance term in the sandwich formula. Booth first showed how correlated sampling can be applied with batch statistics using MCNP’s tally fluctuation chart (TFC) to reduce the uncertainty of a difference of tallies in fixed-source problems. Booth presented a problem in which a 1273% uncertainty in a difference was reduced to 8% by accounting for correlations. Researchers He and Su recently studied correlated sampling using the TFC in MCNP version 5. They determined that the code did not print enough digits in the TFC tally means for accurate batch statistics in some cases. After modifying the source code, they concluded that “correlated sampling can yield a standard deviation of about one magnitude smaller than that predicted by the direct, un-correlated simulation when the changes in system response are small (say about 1%), which is equivalent to saving in CPU time by a factor of 100. Such saving [sic] becomes less significant as the change in system response becomes larger.” He and Su provided the formulas needed to apply batch statistics to compute the correlated uncertainty of a difference of tallies. In this report, we follow up on their work by providing the formulas needed to apply batch statistics to compute the correlated uncertainty of a ratio of tallies and of a difference of two tallies divided by a third tally. We extend these formulas to differences and ratios of ratios. These formulas are applied to reduce the uncertainty associated with calculating a relative sensitivity. He and Su did not investigate the accuracy of their correlated sampling uncertainty estimates. We use their test problems and evaluate the accuracy of the uncertainty estimates by comparing with results obtained from random sampling, and, in simple cases, with theoretical values of the “exact” uncertainties. We find that the uncertainties obtained from batch statistics are accurate as long as at least 100 batches are used. We present a new computer code, COSUBS (COrrelated Sampling Using Batch Statistics), that reads MCNP6 TFCs and applies correlated sampling using batch statistics for the tally combinations that the user specifies. COSUBS is a very general tool that compares all TFCs for a base case and one or two perturbed cases. It computes uncertainties for ratios if given only a base case. This report is organized as follows. The equations to apply batch statistics to the difference of random tallies are reviewed in Sec. II. Section III presents the equations for applying batch statistics to a ratio of random tallies; this is useful for computing relative sensitivities using a one-sided finite difference and the relative sensitivity using the differential operator method. Section IV presents the equations for applying batch statistics to a difference of two random tallies divided by a third; this is useful for computing a relative sensitivities using a central difference. Section V presents the equations for applying batch statistics to a difference of two ratios with four random tallies. Section VI presents the equations for applying batch statistics to a one-sided finite difference estimate of the relative sensitivity of a ratio (this uses four random tallies). Section VII presents the equations for applying batch statistics to a central difference estimate of the relative sensitivity of a ratio (this uses six random tallies). Section VIII presents the equations for applying batch statistics to a sum of random tallies. Section IX discusses how to apply batch statistics using MCNP6. Section X presents COSUBS, describing its command-line options and logic. Sections XI through XVI present numerical results for various test problems. Section XVII is a summary and conclusions. Appendix A derives the theoretical Monte Carlo tally variance given certain assumptions; these variances are used to verify the batch statistics for some of the problems. Appendix B lists the MCNP6 input for the unperturbed example problem. Appendix C presents modifications made to MCNP6.3 to support this work.

97 MATHEMATICS AND COMPUTING↗

Simultaneous Sampling Of Two Spectral Sources

New technique uses bundle of fiber optics to sample a dye laser and a spectral lamp simultaneously. By use of real-time display with this sampling technique, two signals superimposed, and effect of any spectral adjustments determined immediately. System used to diagnose combustion.

Jarrett, Olin, Jr.↗

A search for precursors of ultracompact H II regions in a sample of luminous IRAS sources. III. Circumstellar dust properties

The James Clerk Maxwell Telescope has been used to obtain submillimeter and millimeter continuum photometry of a sample of 30 IRAS sources previously studied in molecular lines and centimeter radio continuum. All the sources have IRAS colours typical of very young stellar objects (YSOs) and are associated with dense gas.

(astronomical) pre-main-sequence stars radiosource↗

The Swift-BAT Hard X-ray Transient Monitor

The Burst Alert Telescope (BAT) on the Swift satellite is a large field of view instrument that continually monitors the sky to provide the gamma-ray burst trigger for Swift. An average of more than 70% of the sky is observed on a daily basis. The survey mode data is processed on two sets on time scales: from one minute to one day as part of the transient monitor program, and from one spacecraft pointing (approx.20 minutes) to the full mission duration for the hard X-ray survey program. The transient monitor has recently become public through the web site http:// swift.gsfc.nasa.gov/docs/swift/results/transients/. Sky images are processed to detect astrophysical sources in the 15-50 keV energy band and the detected flux or upper limit is calculated for >100 sources on time scales up to one day. Light curves are updated each time that new BAT data becomes available (approx.10 times daily). In addition, the monitor is sensitive to an outburst from a new or unknown source. Sensitivity as a function of time scale for catalog and unknown sources will be presented. The daily exposure for a typical source is approx.1500-3000 seconds, with a 1-sigma sensitivity of approx.4 mCrab. 90% of the sources are sampled at least every 16 days, but many sources are sampled daily. It is expected that the Swift-BAT transient monitor will become an important resource for the high energy astrophysics community.

Krimm, Hans↗

Correlative X-ray micro-nanotomography with scanning electron microscopy at the Advanced Light Source

Geological samples are inherently multi-scale. Understanding their bulk physical and chemical properties requires characterization down to the nano-scale. A powerful technique to study the three-dimensional microstructure is X-ray tomography, but it lacks information about the chemistry of samples. To develop a methodology for measuring the multi-scale 3D microstructure of geological samples, correlative X-ray micro- and nanotomography were performed on two rocks followed by scanning electron microscopy with energy-dispersive spectroscopy (SEM-EDS) analysis. The study was performed in five steps: (i) micro X-ray tomography was performed on rock sample cores, (ii) samples for nanotomography were prepared using laser milling, (iii) nanotomography was performed on the milled sub-samples, (iv) samples were mounted and polished for SEM analysis and (v) SEM imaging and compositional mapping was performed on micro and nanotomography samples for complimentary information. Correlative study performed on samples of serpentine and basalt revealed multiscale 3D structures involving both solid mineral phases and pore networks. Significant differences in the volume fraction of pores and mineral phases were also observed dependent on the imaging spatial resolution employed. This highlights the necessity for the application of such a multiscale approach for the characterization of complex aggregates such as rocks. Information acquired from the chemical mapping of different phases was also helpful in segmentation of phases that did not exhibit significant contrast in X-ray imaging. Adoption of the protocol used in this study can be broadly applied to 3D imaging studies being performed at the Advanced Light Source and other user facilities.

58 GEOSCIENCES↗

The Quasar Fraction in Low-Frequency Selected Complete Samples and Implications for Unified Schemes

Low-frequency radio surveys are ideal for selecting orientation-independent samples of extragalactic sources because the sample members are selected by virtue of their isotropic steep-spectrum extended emission. We use the new 7C Redshift Survey along with the brighter 3CRR and 6C samples to investigate the fraction of objects with observed broad emission lines - the 'quasar fraction' - as a function of redshift and of radio and narrow emission line luminosity. We find that the quasar fraction is more strongly dependent upon luminosity (both narrow line and radio) than it is on redshift. Above a narrow [OII] emission line luminosity of log(base 10) (L(sub [OII])/W) approximately > 35 [or radio luminosity log(base 10) (L(sub 151)/ W/Hz.sr) approximately > 26.5], the quasar fraction is virtually independent of redshift and luminosity; this is consistent with a simple unified scheme with an obscuring torus with a half-opening angle theta(sub trans) approximately equal 53 deg. For objects with less luminous narrow lines, the quasar fraction is lower. We show that this is not due to the difficulty of detecting lower-luminosity broad emission lines in a less luminous, but otherwise similar, quasar population. We discuss evidence which supports at least two probable physical causes for the drop in quasar fraction at low luminosity: (i) a gradual decrease in theta(sub trans) and/or a gradual increase in the fraction of lightly-reddened (0 approximately < A(sub V) approximately < 5) lines-of-sight with decreasing quasar luminosity; and (ii) the emergence of a distinct second population of low luminosity radio sources which, like M8T, lack a well-fed quasar nucleus and may well lack a thick obscuring torus.

Willott, Chris J.↗

IRAS observations of AGN candidates at low flux levels

IRAS additional observations were used to obtain a sample of point sources at much fainter flux levels than hitherto available through the IRAS Point Source Catalogue. This sample is being used to compile an incomplete but representative catalogue of faint IRAS candidate Active Galactic Nuclei (AGNs) and to study the evolution of the infrared bright galaxies. Ground based follow up observations (optical spectroscopy) are mainly hampered by identification confusion.

Degrijp, Marinus H. K.↗

Integrated Microfluidic Gas Sensors for Water Monitoring

A silicon-based microhotplate tin oxide (SnO2) gas sensor integrated into a polymer-based microfluidic system for monitoring of contaminants in water systems is presented. This device is designed to sample a water source, control the sample vapor pressure within a microchannel using integrated resistive heaters, and direct the vapor past the integrated gas sensor for analysis. The sensor platform takes advantage of novel technology allowing direct integration of discrete silicon chips into a larger polymer microfluidic substrate, including seamless fluidic and electrical interconnects between the substrate and silicon chip.

Zhu, L.↗

X-ray spectra of a complete sample of extragalactic core-dominated radio sources

We present ROSAT soft X-ray spectra for the members of a complete sample of 13 core-dominated, flat radio spectrum sources. The sample comprises all radio sources from a flux-limited radio catalog (S(sub 5GHz) greater than 1 Jy; Kuehr et al. 1981) which are north of delta = 70 deg, at galactic latitudes b greater than 10 deg, and have a flat radio spectrum between 1.4 and 5 GHz (alpha(sub r) less than 0.5; f approximately nu(sup -alpha)). The sources have already undergone much study at radio and optical wavelengths and are classified in broad terms as quasars (8 sources) and BL Lac objects (5 sources). We find mean X-ray power-law energy indices of alpha(sub x) = 0.59 +/- 0.19 for the quasars and 1.36 +/- 0.27 for the BL Lac objects (68% confidence range for two parameters of interest as determined by a maximum likelihood method), supporting earlier Einstein Observatory results for heterogeneous samples of sources (Worrall & Wilkes 1990). A non-zero dispersion on alpha(sub x) is found for both the quasars and the BL Lac objects. When we incorporate published radio, mm, and optical measurements and compare the X-ray and broad-band spectral indices alpha(sub x), alpha(sub rx), alpha(sub mm,x), and alpha(sub ox), the most obvious difference between the quasar and BL Lac subsamples lies within the X-ray band. We have fitted the multi-wavelength data to inhomogeneous synchotron-self-Compton models and find that, for the BL Lac objects with steep X-ray spectra, synchotron emission can account for the radio to soft X-ray measurements, whereas the BL Lac objects with hard X-ray spectra and the quasars require significant Compton emission to model the spectral flattening indicated by alpha(sub x) less than alpha(sub ox).

Brunner, H.↗

Sample size and sampling errors as the source of dispersion in chemical analyses

The paper describes a Monte Carlo model for simulation of two-dimensional representations of thin sections of some of the more common igneous rock textures. These representations are extrapolated to three dimensions to develop a volume of 'rock'. The model (here applied to a medium-grained high-Ti basalt) can be used to determine a statistically significant sample for a lunar rock or to predict the probable errors in the oxide contents that can occur during the analysis of a sample that is not representative of the parent rock.

Clanton, U. S.↗

Radiation Mapping for an Unmanned Aerial Vehicle: Development and Simulated Testing of Algorithms for Source Mapping and Navigation Path Generation

Image reconstruction algorithms were developed for radiation source mapping and used for generating the search path of a moving radiation detector, such as one onboard an unmanned aerial vehicle. Simulations consisted of first assuming radioactive sources of varying complexity and estimating the radiation fields that would then be produced by that source distribution. Next, the "measurements" that would result from a pair of adjacent spatial locations were computed. A crude estimate of the source distribution likely to have produced such "measurements" was reconstructed based upon the limited measurements. Location of the next "measurement" was then determined as halfway between the location of the estimated source and the current "measurement." With each additional sample, improved source distribution reconstructions were made and used to inform the immediate direction of detector motion. Source reconstruction or mapping was formulated as an inverse problem solved with either maximum a posteriori or least squares (LS) regression deconvolution methods. Different amounts of noise were added to the simulated "measurements," allowing evaluation of the methods' performances as functions of signal-to-noise ratio of the measured map. As expected, methods that promote sparsity were better suited in reconstructing point sources. Reliable prior information of the source distribution also improved the reconstruction results, especially with distributed sources. With a non-negative least square algorithm and the suggested paths it generated, location of sources was successfully estimated to an accuracy of 0.014 m within nine iterations in a single-source scenario and 12 iterations in a two-source scenario, given a 10% error on the integrated counts and a Poisson distribution of the noise associated with the measured counts.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Material Property Determinations for Rock Valley Legacy Samples in Support of Source Physics Experiment

The Source Physics Experiment (SPE) is a long-term NNSA research and development effort designed to improve nonproliferation verification and monitoring capabilities. The overarching goals of the SPE program are to improve understanding of prompt signals and physical signatures that develop from underground chemical explosions and associated modeling capabilities. Our work focuses on a primary factor controlling chemical explosion induced signals and signatures: the material properties of the rocks in which the chemical explosion takes place. This document reports on material property determinations of legacy core USGS Test Well F and outcrop analogs for the subsurface stratigraphy for the third phase of SPE in the Rock Valley (RV) area of the Nevada National Security Site (NNSS). The objective of this work is to establish a baseline set of lithologic descriptions and material properties expected prior to observatory borehole drilling in support of the SPE-RVDC (Rock Valley Direct Comparison) experiment. We determine for each rock type the compressional failure envelope, elastic properties as a function of stress (bulk modulus versus mean stress, shear modulus versus shear stress, Young’s modulus versus axial stress and Poisson’s ratio versus axial stress), indirect tensile strength, and porosity. Geologic characterization, both at the core-scale and microscale, provides context for using the data in modeling efforts and to inform interpretations for the material properties testing.

36 MATERIALS SCIENCE↗

Early evolution of the crust-mantle system

Nd isotopic data indicate that most Archean igneous rocks including compositions ranging from komatiite to tonalite are derived from undepleted or depleted upper mantle sources. If sampling is representative, only a few require enriched sources. A major unresolved question is the fate of the material removed from the upper mantle leaving early depleted sources as residue. One possibility is that widespread depletion of the early mantle resulted from a period of early degassing and magmatism. Rare gas isotopic data, in particular 129Xe/130Xe ratios, seem to demand that the upper mantle was extensively degassed at or before 4.4 b.y. and this led to rapid growth of the atmosphere and oceans. The lower mantle, however, was not significantly degassed during this event. It is likely that such widespread degassing and magmatism of the upper mantle transferred significant quantities of incompatible elements into the uppermost mantle or crust. Once formed, such an enriched fraction should resist recycling into the mantle and collect at or near the Earth's surface. One possibility is that it collects chiefly in a zone of partial melting, analogous to the present low-velocity zone at the base of the lithosphere.

Condie, K. C.↗

Dual Source Mass Spectrometer and Sample Handling System

We present details of a miniature integrated time-of-flight mass spectrometer and sample handling system under development to address some of the needs for in situ sample analysis on landed missions. Additional information is contained in the original extended abstract.

Brinckerhoff, W. B.↗