Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space Center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Instrument of the Imaging X-Ray Polarimetry Explorer

While X-ray spectroscopy, timing, and imaging have improved much since 1962 when the first astronomical nonsolar source was discovered, especially wi the launch of the Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer, and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detectors, which in turn is a result of the fate of approved missions and because celestial X-ray sources appear less polarized than expected. Only one positive measurement has been available until now: the Orbiting Solar Observatory measured the polarization of the Crab Nebula in the 1970s. The advent of microelectronics techniques has allowed for designing a detector based on the photoelectric effect of gas in an energy range where the optics are efficient at focusing in X-rays. Here we describe the instrument, which is the major contribution of the Italian collaboration to the Small Explorer mission called IXPE, the Imaging X-ray Polarimetry Explorer, which will launch in late 2021. The instrument is composed of three detector units based on this technique and a detector service unit. Three mirror modules provided by Marshall Space Flight Center focus X-rays onto the detectors. We show the technological choices, their scientific motivation, and results from the calibration of the instrument. IXPE will perform imaging, timing, and energy-resolved polarimetry in the 2–8 keV energy band opening this window of X-ray astronomy to tens of celestial sources of almost all classes.

79 ASTRONOMY AND ASTROPHYSICS↗

High density optical waveguide using hybrid spiral pattern

A hybrid spiral waveguide geometry is proposed that exhibits essentially zero curvature (i.e., infinite bend radius) at the center of the spiral (similar to a Fermat spiral), with the curvature then increasing in value as the spiral moves outward. Advantageously, as the spiral moves away from the center, the spacing between adjacent waveguides quickly approaches a constant value (similar to an Archimedean spiral). This hybrid spiral structure has been found to allow for a high density waveguide to be created with lower loss and requiring a smaller size than many conventional spiral configurations and finds use in optical delay lines, amplifiers and arrayed waveguide gratings.

42 ENGINEERING↗

XRISM/Resolve view of Abell 2319: Turbulence, sloshing, and ICM dynamics

Here, we present results from XRISM/Resolve observations of the core of the galaxy cluster Abell 2319, focusing on its kinematic properties. The intracluster medium (ICM) exhibits temperatures of approximately 8 keV across the core, with a prominent cold front and a high-temperature region (⁠~11 keV) in the north-west. The average gas velocity in the 3' x 4' region around the brightest cluster galaxy (BCG) covered by two Resolve pointings is consistent with that of the BCG to within 40 km s -1 ⁠ and we found modest average velocity dispersion of 230–250 km s -1 ⁠. On the other hand, spatially resolved spectroscopy reveals interesting variations. A blueshift of up to ~230 km s -1 ⁠ is observed around the east edge of the cold front, where the gas with the lowest specific entropy is found. The region further south inside the cold front shows only a small velocity difference from the BCG; however, its velocity dispersion is enhanced to ~400 km s -1 ⁠, implying the development of turbulence. These characteristics indicate that we are observing sloshing motion with some inclination angle following BCG and that gas phases with different specific entropy participate in sloshing with their own velocities, as expected from simulations. No significant evidence for a high-redshift ICM component associated with the subcluster Abell 2319B was found in the region covered by the current Resolve pointings. These results highlight the importance of sloshing and turbulence in shaping the internal structure of Abell 2319. Further deep observations are necessary to better understand the mixing and turbulent processes within the cluster.

Astronomy and AstroPhysics↗

Thermal and kinematic properties of ejecta in SN1987A revealed by XRISM

We present an analysis of high-resolution spectra from the shock-heated plasmas in SN 1987A, based on an observation using the Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM). The 1.7–10 keV Resolve spectra are accurately represented by a single-component, plane-parallel shock plasma model, with a temperature of $2.84_{-0.08}^{+0.09}$ keV and an ionization parameter of $2.64_{-0.45}^{+0.58}$ × $10^{11}\,\,{\rm s\,\, cm}^{-3}$. The Resolve spectra are also well reproduced by the 3D magneto-hydrodynamic simulation presented by Orlando et al. (2020, A&A, 636, A22) suggesting substantial contribution from the ejecta. The metal abundances obtained with Resolve align with the Large Magellanic Cloud value, indicating that the X-rays in 2024 originate from “non-metal-rich” shock-heated ejecta and the reverse shock has not reached the inner metal-rich region of ejecta. Doppler widths of the atomic lines from Si, S, and Fe correspond to velocities of 1500–1700 km s$^{-1}$, where the thermal broadening effects in this non-metal-rich plasma are negligible. Therefore, the line broadening seen in Resolve spectra is determined by the large bulk motion of ejecta. For reference, we determined a $90\%$ upper limit on non-thermal emission from a pulsar wind nebula at $4.3 \times 10^{-13}$ erg cm$^{-2}$ s$^{-1}$ in the 2–10 keV range, aligning with NuSTAR findings by Greco et al. (2022, ApJ, 931, 132). Additionally, we searched for the $^{44}$Sc K line feature and found a $1\sigma$ upper limit of $1.0 \times 10^{-6}$ photons cm$^{-2}$ s$^{-1}$, which translates to an initial $^{44}$Ti mass of approximately $2 \times 10^{-4}\, M_{\odot }$, consistent with previous X-ray to soft gamma-ray observations (Boggs et al. 2015, Science, 348, 670; Grebenev et al. 2012, Nature, 490, 373; Leising 2006, ApJ, 651, 1019).

ISM: supernova remnants↗

Initial in-orbit operation of the soft X-ray spectrometer Resolve onboard the X-ray imaging and spectroscopy mission satellite

The X-Ray Imaging and Spectroscopy Mission satellite was launched on September 6, 2023 (UT). Its Resolve instrument is a high-resolution X-ray spectrometer enabled by a microcalorimeter array thermally anchored to a 50-mK heat sink. Many sensitive, critical sub-systems comprise Resolve, including a multistage cryogenic cooling system, thin-film aperture filters, low-noise electronics, on-board signal processing, and several sources of X-rays for calibration. We summarize the initial on-orbit power-on and checkout of Resolve that commenced immediately after launch. Soon after launch, the cryocoolers were activated, and their operation was successfully established. On October 9, 2023, the first cycle of the adiabatic demagnetization refrigerator was carried out, bringing the sensors to their steady-state operational temperatures. Following this, the energy resolution at 5.9 keV was successfully measured. The energy scale of the system is highly sensitive to the thermal environment surrounding both the sensors and their analog electronics. Gain correction was performed using reference X-ray lines from onboard calibration sources. To optimize cooler frequency settings, noise spectra were collected across a range of frequencies, and the most suitable frequency pair was selected based on the in-orbit environment. During the final phase of the checkout, an attempt was made to open the gate valve, which is designed to protect the Dewar’s interior from external pressure during ground operations and launch. Unfortunately, this attempt was unsuccessful. As a result, the checkout process was temporarily paused, and a stable operational strategy was subsequently developed to enable Resolve to function effectively with the gate valve remaining closed.

X-ray micro-calorimeter↗

Foreword Special issue on the Kilopower Project, Kilowatt Reactor Using Stirling TechnologY (KRUSTY) Test

This special issue of Nuclear Technology contains full-length, peer-reviewed papers describing the design work leading up to and the results of the Kilowatt Reactor Using Stirling TechnologY (KRUSTY) test. KRUSTY was the centerpiece of the National Aeronautics and Space Administration (NASA) Kilopower Project to design, build, and test a space nuclear reactor. This test was the first such test since the end of the Space Nuclear Auxiliary Power (SNAP) project at the end of the 1960s. In this issue, the introduction paper presents the goals of the Kilopower Project and the potential missions this reactor concept could serve in NASA. Kilopower was intended to serve both human exploration needs on planetary surfaces as well as science needs for deep-space exploration. The design work for the experiment by Poston and the power conversion development by Gibson present the pre-work required to perform the eventual KRUSTY test. A paper on regulatory analysis follows, to show the path used to gain approval of the proposed experiment. Then, the early zero-power critical experiments are presented by Sanchez and Grove. These experiments were essential data used to enhance model predictions prior to the high-temperature test. Next, Poston presents the three experiments (warm criticals) that increase the temperature in an incremental fashion prior to the final experiment. These experiments were used to achieve final regulatory approval of the final high-temperature experiment. The last paper by Poston presents the results of the steady-state and transient testing of the reactor at full power and at the design temperature. These results show that the reactor design and as-built experiment met all of the requirements that NASA had developed for the system. Any experiment of this magnitude was accomplished only because of the hard work and dedication of a large number of people at multiple institutions, including the NASA Glenn Research Center, NASA Marshall Space Flight Center, Y-12 National Security Site, Los Alamos National Laboratory, and the Nevada National Security Site prime contractor (formerly National Security Technologies and now the Mission Support and Test Services). The project was jointly funded by the Space Technology Mission Directorate at NASA and the Criticality Safety Program at the National Nuclear Security Administration (NNSA). A special thanks to Jerry McKamy and Angela Chambers at the NNSA and Lee Mason and Don Palac at NASA for their support and guidance. For the authors and multitude of staff that performed this work, the passion for space nuclear reactors was the key to making this experiment a reality.

99 GENERAL AND MISCELLANEOUS↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

High-spectral-resolution X-Ray Observations of the Evolved Supermassive Stellar Binary System η Carinae: Fe K α Band Profile Revealed with XRISM

The supermassive binary system, η Carinae, is experiencing enormous wind-driven mass loss at a rate unparalleled in the rest of the Galaxy. Their wind–wind collision (WWC) continuously produces shock heated, X-ray-emitting plasmas. The XRISM X-ray observatory observed the system in 2023 and 2024 when the X-ray emission began to increase toward periastron passage in 2025. This paper reports unprecedentedly high-resolution X-ray spectra in the Fe Kα band between 6.2 and 7.1 keV, obtained with the Resolve X-ray microcalorimeter. The hydrogen-like (Lyα) and helium-like (Heα) lines reveal three velocity components. Two of them are broadened with maximum velocities of 2000–3000 km s −1 , likely originating from the postshock companion wind. The other is relatively narrow, with a Gaussian broadening of only ∼290 km s −1 in 1σ, which may originate from the postshock companion wind at the WWC stagnation point or penetrating the primary wind. The Fe fluorescent lines exhibit a moderate blueshift and broadening with velocities at 100–200 km s −1 , consistent with the primary wind’s velocity field. The spectra also confirm a Compton shoulder of the Heα line complex for the first time. Both fluorescing and scattering spectral profiles indicate that the binary system is seen from the companion side during these observations. The flux ratio of the Compton-scattering emission to the fluorescent line suggests substantial hydrogen depletion of the primary wind, expected from CNO-cycled hydrogen nuclear fusion gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Resolve instrument onboard XRISM: design, integration, and instrument test results

The Resolve instrument onboard the X-Ray Imaging and Spectroscopy Mission (XRISM) consists of an array of 6 × 6 silicon-thermistor microcalorimeters cooled down to 50 mK and a high-throughput X-ray mirror assembly (XMA) with a focal length of 5.6 m. XRISM is a recovery mission of ASTRO-H/Hitomi, and the Resolve instrument is a rebuild of the ASTRO-H Soft X-ray spectrometer (SXS) and the Soft X-ray Telescope (SXT) that achieved energy resolution of ∼ 5 eV FWHM on orbit, with several important changes based on lessons learned from ASTRO-H. The flight models of the Dewar and the electronics boxes were fabricated, and the instrument test and calibration were conducted in 2021. By tuning the cryocooler frequencies, energy resolution better than 4.9 eV FWHM at 6 keV was demonstrated for all 36 pixels and high-resolution grade events, as well as energy-scale accuracy better than 2 eV up to 30 keV. The immunity of the detectors to microvibration, electrical conduction, and radiation was evaluated. The instrument was delivered to the spacecraft system in April 2022. The XMA was tested and calibrated separately. Its angular resolution is 1.27′, and the effective area of the mirror itself is 570 cm 2 at 1 keV and 424 cm 2 at 6 keV. We report the design and the major changes from the ASTRO-H SXS, the integration, and the results of the instrument test.

X-ray↗

High-speed Boulders and the Debris Field in DART Ejecta

On 2022 September 26 the Double Asteroid Redirection Test (DART) spacecraft collided with Dimorphos, the moon of the near-Earth asteroid 65803 Didymos, in a full-scale demonstration of a kinetic impactor concept. The companion Light Italian Cubesat for Imaging of Asteroids (LICIACube) spacecraft documented the aftermath, capturing images of the expansion and evolution of the ejecta from 29 to 243 s after the impact. We present results from our analyses of these observations, including an improved reduction of the data and new absolute calibration, an updated LICIACube trajectory, and a detailed description of the events and phenomena that were recorded throughout the flyby. One notable aspect of the ejecta was the existence of clusters of boulders, up to 3.6 m in radius, that were ejected at speeds of up to 52 m s −1 . Our analysis of the spatial distribution of 104 of these boulders suggests that they are likely the remnants of larger boulders shattered by the DART spacecraft in the first stages of the impact. The amount of momentum contained in these boulders is more than 3 times that of the DART spacecraft, and it is directed primarily to the south, almost perpendicular to the DART trajectory. Recoil of Dimorphos from the ejection of these boulders has the potential to change its orbital plane by up to a degree and to impart a non-principal-axis component to its rotation state. Damping timescales for these phenomena are such that the Hera spacecraft, arriving at the system in 2026, should be able to measure these effects.

asteroid dynamics↗

AstroPix: A pixelated HVCMOS sensor for space-based gamma-ray measurement

A next-generation medium-energy gamma-ray telescope targeting the MeV range would address open questions in astrophysics regarding how extreme conditions accelerate cosmic-ray particles, produce relativistic jet outflows, and more. One concept, AMEGO-X, relies upon the mission-enabling CMOS Monolithic Active Pixel Sensor silicon chip AstroPix. AstroPix is designed for space-based use, featuring low noise, low power consumption, and high scalability. Desired performance of the device include an energy resolution of 5 keV (or 10% FWHM) at 122 keV and a dynamic range per-pixel of 25–700 keV, enabled by the addition of a high-voltage bias to each pixel which supports a depletion depth of 500 μ m. This work reports on the status of the AstroPix development process with emphasis on the current version under test, version three (v3), and highlights of version two (v2). Version 3 achieves energy resolution of 10.4 ± 3.2% at 59.5 keV and 94 ± 6 μ m depletion in a low-resistivity test silicon substrate.

Astrophysics instrumentation↗

Hot Hydrogen Exposure of U x Zr 1-x C y Nuclear Fuel: The Effect of Additional Carbon

Nuclear thermal propulsion (NTP) using hydrogen as propellant in a solid-state fission reactor to reach temperatures of up to 3000K can achieve significantly higher specific impulse than chemical propulsion. A promising fuel that is again considered for NTP is U x Zr 1-x C y . To reduce the overall mass loss as well as the uranium fuel loss, a range of experiments using additional carbon in hot hydrogen (2600 K, 6 SLPM flow rate) were performed for up to 5-6 h. Both a CH 4 addition (0.1 and 0.2 vol%) in the hydrogen stream and the use of sacrificial graphite pieces upstream of the samples were tested, with sample compositions from 5 at% UC to 30 at% UC. The results showed a strong reduction of mass loss, up to a factor of 3, as well as a reduction of surface uranium losses in the presence of additional carbon in the atmosphere. Even with additional carbon in the atmosphere, material with 30 at% UC was not stable, but material with 20 at% UC was stable for up to 6h. The sample surfaces showed texturing after processing, possibly by grain growth on the surface. This led to a separation into grains with high uranium content close to the (100)-orientation, and with low uranium content in grains close to the (111)-orientation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

Core line spread function calibration of the X-ray Imaging and Spectroscopy Mission Resolve X-ray calorimeter spectrometer

The Resolve X-ray imaging spectrometer onboard the X-ray Imaging and Spectroscopy Mission consists of a 36 pixel array of high-resolution X-ray calorimeters each with ∼ 5 eV full-width-at-half-maximum (FWHM) spectral resolution in the 0.3 to 12 keV band. The response to monochromatic X-rays (line spread function, LSF) is composed of a narrow Gaussian core and weak extended components caused by energy loss during thermalization. We report on the characterization of the Gaussian core LSF in an extensive ground calibration campaign. We also discuss the characterization of on-orbit resolution, which shows slightly higher FWHM than that obtained on the ground.

Astronomy and AstroPhysics↗

WHYMSIE-SGP Field Campaign Report

Through a partnership between the U.S. National Aeronautics and Space Administration (NASA) and the National Oceanic and Atmospheric Administration (NOAA), this field campaign demonstrated first-of-its-kind hyperspectral microwave airborne measurements (Conical Scanning Millimeter-wave Imaging Radiometer [CoSMIR-H]). It was complemented by other passive (infrared, visible) and active (lidar) sensors onboard the NASA ER-2 aircraft. Serving as a future NASA planetary boundary-layer (PBL) mission prototype, the Westcoast and Heartland Hyperspectral Microwave Intensive Experiment (WH 2 yMSIE, formerly WHyMSIE) aimed to capture a wide variety of thermodynamic, moisture, and PBL regimes across a variety of surface types. The intensive operating period of the campaign spanned from October 22, 2024, through November 15, 2024, and included a large network of collaborators.

54 ENVIRONMENTAL SCIENCES↗