Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space infrared telescope facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Thermal and cryogenic design study for space infrared telescope facility (SIRTF)

A study was conducted to determine the ability of an all superfluid helium design to meet the performance requirements of background limited to 200 micrometer, and a two year lifetime for a one meter class free flying infrared observatory. Both a 98 deg and 28.5 deg inclination orbits were examined, and aperture shade designs were developed for both orbits. A unique forebaffle cooling design significantly reduces the sensitivity to aperture heat loads. With certain restrictions on observing modes, the study determined that an all superfluid helium Dewar will meet the temperature and lifetime requirements. A dual cryogen SFHe/SH2 system was also investigated for the 28.5 deg orbit and found to provide a more constant forebaffle temperature but with only a slight improvement in lifetime.

Urbach, A. R.↗

Study of alternate optical and fine guidance sensor designs for the space infrared telescope facility (SIRTF)

A unique optical design was developed that compensates for the coma degraded images caused by field chopping in SIRTF. The conic constants of a Cassegrain telescope were altered to compensate for the coma induced by the secondary mirror tilt. The modulation transfer function is essentially independent of secondary mirror tilt, and diffraction limited image quality is maintained over a several arcminute field during chopping. With an untilted secondary mirror, the coma compensated (CC) design has a smaller field than the unchopped Ritchey-Chretien design; but use of relay optics, such as the inverted Cassegrain design developed for the fine guidance sensor (FGS), can increase the CC telescope's field size. A reactionless secondary mirror chopper mechanism that uses superconducting magnets was studied. The heart producing elements are confined to a reaction plate that is not directly viewed by the IR focal plane. A design was also developed for a low moment of inertia, reticulated HIP beryllium secondary mirror consistent with blank fabrication technology and optical finishing requirements.

Wissinger, A.↗

Fine guidance sensor design optimization for Space Infrared Telescope Facility (SIRTF)

The present paper is concerned with the general issues of design optimization of a staring mosaic sensor for guide-star tracking, taking into account the choice of the proper interpolation algorithm. It was found that the final choice of algorithm depends on the severity of the positional accuracy requirement and the expected variation in the blur spot shape. The considered track algorithms estimate the position either of the peak or of the centroid of the image of a point source. Attention is given to aspects of problem definition, the total effect of error sources on algorithm accuracy, a parametric analysis of performance behavior, Monte Carlo results, and the design of the SIRTF Fine Guidance Sensor (FGS). The algorithm error, the signal-to-noise error, and the nonuniformity error are examined.

Grossman, S. B.↗

Space infrared telescope facility wide field and diffraction limited array camera (IRAC)

IRAC focal plane detector technology was developed and studies of alternate focal plane configurations were supported. While any of the alternate focal planes under consideration would have a major impact on the Infrared Array Camera, it was possible to proceed with detector development and optical analysis research based on the proposed design since, to a large degree, the studies undertaken are generic to any SIRTF imaging instrument. Development of the proposed instrument was also important in a situation in which none of the alternate configurations has received the approval of the Science Working Group.

Fazio, G. G.↗

Moderate resolution spectroscopy for the Space Infrared Telescope Facility (SIRTF)

A conceptual design for an IR spectrometer capable of both low resolution (lambda/Delta-lambda = 50; 2.5-200 microns) and moderate resolution (1000; 4-200 microns) has been developed. This instrument will allow the spectroscopic study in the infrared of objects ranging from within the solar system to distant galaxies. The spectroscopic capability provided by this instrument for SIRTF will give astronomical orders of magnitude greater sensitivity for the investigation of faint objects than has been previously available.

Houck, J. R.↗

Moderate resolution spectroscopy for the Space Infrared Telescope Facility (SIRTF)

The conceptual design presented for a low-to-moderate resolution IR spectrometer is expected to allow the spectroscopic study of objects whose location ranges from within the solar system to distant galaxies, with far greater sensitivity than previously available for the study of faint objects. The low resolution mode will allow detailed continuum radiation studies to be conducted, while the moderate resolution mode will facilitate studies encompassing the IR spectral signatures of small outer solar system bodies and the nature of more luminous active galaxies and QSOs at greater distances. The five spectrometer modules share a common aperture, and all gratings share a single scan mechanism. All heat sources other than the detectors operate at 7 K and are separated from the 4 K cold station. Two-dimensional area detector arrays are used in the 2.5- to 120-micron bands to simultaneously monitor adjacent regions in extended objects and to measure the background near point sources.

Houck, J. R.↗

Space infrared telescope facility wide field and diffraction limited array camera (IRAC)

The wide-field and diffraction limited array camera (IRAC) is capable of two-dimensional photometry in either a wide-field or diffraction-limited mode over the wavelength range from 2 to 30 microns with a possible extension to 120 microns. A low-doped indium antimonide detector was developed for 1.8 to 5.0 microns, detectors were tested and optimized for the entire 1.8 to 30 micron range, beamsplitters were developed and tested for the 1.8 to 30 micron range, and tradeoff studies of the camera's optical system performed. Data are presented on the performance of InSb, Si:In, Si:Ga, and Si:Sb array detectors bumpbonded to a multiplexed CMOS readout chip of the source-follower type at SIRTF operating backgrounds (equal to or less than 1 x 10 to the 8th ph/sq cm/sec) and temperature (4 to 12 K). Some results at higher temperatures are also presented for comparison to SIRTF temperature results. Data are also presented on the performance of IRAC beamsplitters at room temperature at both 0 and 45 deg angle of incidence and on the performance of the all-reflecting optical system baselined for the camera.

Fazio, Giovanni G.↗

Space Infrared Telescope Facility cryogenic and optical technology

SIRTF will require new liquid helium cryogenics and optical technology at liquid helium temperatures to meet the scientific requirements. In particular, it will require a helium cryogenic system operating at 1.25 K with a lifetime of five years. The optical system will require a 1-m mirror operating at 2 K, which is diffraction limited at 3 microns. This paper describes the advances which will be needed and the approaches to be taken.

Mason, P.↗

Registered File Support for Critical Operations Files at (Space Infrared Telescope Facility) SIRTF

The SIRTF Science Center's (SSC) Science Operations System (SOS) has to contend with nearly one hundred critical operations files via comprehensive file management services. The management is accomplished via the registered file system (otherwise known as TFS) which manages these files in a registered file repository composed of a virtual file system accessible via a TFS server and a file registration database. The TFS server provides controlled, reliable, and secure file transfer and storage by registering all file transactions and meta-data in the file registration database. An API is provided for application programs to communicate with TFS servers and the repository. A command line client implementing this API has been developed as a client tool. This paper describes the architecture, current implementation, but more importantly, the evolution of these services based on evolving community use cases and emerging information system technology.

file management services↗