Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral shape”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Exploring high-intensity laser-driven secondary sources via high-order spectral pulse shaping for high-energy-density experiments

We present here the results of an investigation that aims to explore the impact of spectral pulse shaping on the generation of high-energy electrons (>1 MeV) and x rays (∼5–9 keV) using a high-intensity (I∼10 21 W/cm 2 ) laser system. The study involved a systematic scan of a broad parameter space in group delay dispersion and third-order dispersion, with variations up to 4 × 10 3 fs −2 and 6 × 10 4 fs −3 , respectively, to identify optimal conditions for enhancing secondary source yields. Several spectral phase conditions were found to significantly enhance the generation of hot electrons and x rays by amounts reaching up to 50% relative to the transform-limited pulse. The experiment, conducted at the Scarlet laser facility (800 nm, 5 J, 30 fs) at the Ohio State University, highlights the potential of spectral pulse shaping as a powerful tool for tuning secondary laser-driven sources. These findings are particularly relevant for advancing brighter x-ray and electron probes for high-energy-density science.

Physics - Plasma physics↗

Measurement of the electron density in a subatmospheric dielectric barrier discharge by spectral line shape

The electron density in a subatmospheric dielectric barrier discharge by using argon spectral line shape is measured for the first time. With the gas pressure increasing in the range of 1x10{sup 4} Pa-6x10{sup 4} Pa, the line profiles of argon 696.54 nm are measured. An asymmetrical deconvolution procedure is applied to separate the Gaussian and Lorentzian profile from the measured spectral line. The gas temperature is estimated by using rotational temperature of N{sub 2}{sup +}. By subtracting the van der Waals broadening and partial Lorentzian instrumental broadening from the Lorentzian broadening, the Stark broadening is obtained and used to estimate the electron density. It is found that the electron density in dielectric barrier discharge increases with the increase in gas pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnosing suprathermal ion populations in Z-pinch plasmas using fusion neutron spectra

The existence of suprathermal ion populations gives rise to significant broadening of and modifications to the fusion neutron spectrum. We show that when this population takes the form of a power-law at high energies, specific changes occur to the spectrum which are diagnosable. In particular, the usual Gaussian spectral shape produced by a thermal plasma is replaced by a Lorentz-like spectrum with broad wings extending far from the spectral peak. Additionally, it is found that the full width at half maximum of the spectrum depends on both the ion temperature and the power-law exponent. This causes the use of the spectral width for determination of the ion temperature to be unreliable. We show that these changes are distinguishable from other broadening mechanisms, such as temporal and motional broadening, and that detailed fitting of the spectral shape is a promising method for extracting information about the state of the ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bowtie filters for dedicated breast CT: Theory and computational implementation

Purpose: To design bowtie filters with improved properties for dedicated breast CT to improve image quality and reduce dose to the patient. Methods: The authors present three different bowtie filters designed for a cylindrical 14-cm diameter phantom with a uniform composition of 40/60 breast tissue, which vary in their design objectives and performance improvements. Bowtie design #1 is based on single material spectral matching and produces nearly uniform spectral shape for radiation incident upon the detector. Bowtie design #2 uses the idea of basis material decomposition to produce the same spectral shape and intensity at the detector, using two different materials. Bowtie design #3 eliminates the beam hardening effect in the reconstructed image by adjusting the bowtie filter thickness so that the effective attenuation coefficient for every ray is the same. All three designs are obtained using analytical computational methods and linear attenuation coefficients. Thus, the designs do not take into account the effects of scatter. The authors considered this to be a reasonable approach to the filter design problem since the use of Monte Carlo methods would have been computationally intensive. The filter profiles for a cone-angle of 0° were used for the entire length of each filter because the differences between those profiles and the correct cone-beam profiles for the cone angles in our system are very small, and the constant profiles allowed construction of the filters with the facilities available to us. For evaluation of the filters, we used Monte Carlo simulation techniques and the full cone-beam geometry. Images were generated with and without each bowtie filter to analyze the effect on dose distribution, noise uniformity, and contrast-to-noise ratio (CNR) homogeneity. Line profiles through the reconstructed images generated from the simulated projection images were also used as validation for the filter designs. Results: Examples of the three designs are presented. Initial verification of performance of the designs was done using analytical computations of HVL, intensity, and effective attenuation coefficient behind the phantom as a function of fan-angle with a cone-angle of 0°. The performance of the designs depends only weakly on incident spectrum and tissue composition. For all designs, the dynamic range requirement on the detector was reduced compared to the no-bowtie-filter case. Further verification of the filter designs was achieved through analysis of reconstructed images from simulations. Simulation data also showed that the use of our bowtie filters can reduce peripheral dose to the breast by 61% and provide uniform noise and CNR distributions. The bowtie filter design concepts validated in this work were then used to create a computational realization of a 3D anthropomorphic bowtie filter capable of achieving a constant effective attenuation coefficient behind the entire field-of-view of an anthropomorphic breast phantom. Conclusions: Three different bowtie filter designs that vary in performance improvements were described and evaluated using computational and simulation techniques. Results indicate that the designs are robust against variations in breast diameter, breast composition, and tube voltage, and that the use of these filters can reduce patient dose and improve image quality compared to the no-bowtie-filter case.

60 APPLIED LIFE SCIENCES↗

Bowtie filters for dedicated breast CT: Analysis of bowtie filter material selection

Purpose: For a given bowtie filter design, both the selection of material and the physical design control the energy fluence, and consequently the dose distribution, in the object. Using three previously described bowtie filter designs, the goal of this work is to demonstrate the effect that different materials have on the bowtie filter performance measures. Methods: Three bowtie filter designs that compensate for one or more aspects of the beam-modifying effects due to the differences in path length in a projection have been designed. The nature of the designs allows for their realization using a variety of materials. The designs were based on a phantom, 14 cm in diameter, composed of 40% fibroglandular and 60% adipose tissue. Bowtie design #1 is based on single material spectral matching and produces nearly uniform spectral shape for radiation incident upon the detector. Bowtie design #2 uses the idea of basis-material decomposition to produce the same spectral shape and intensity at the detector, using two different materials. With bowtie design #3, it is possible to eliminate the beam hardening effect in the reconstructed image by adjusting the bowtie filter thickness so that the effective attenuation coefficient for every ray is the same. Seven different materials were chosen to represent a range of chemical compositions and densities. After calculation of construction parameters for each bowtie filter design, a bowtie filter was created using each of these materials (assuming reasonable construction parameters were obtained), resulting in a total of 26 bowtie filters modeled analytically and in the PENELOPE Monte Carlo simulation environment. Using the analytical model of each bowtie filter, design profiles were obtained and energy fluence as a function of fan-angle was calculated. Projection images with and without each bowtie filter design were also generated using PENELOPE and reconstructed using FBP. Parameters such as dose distribution, noise uniformity, and scatter were investigated. Results: Analytical calculations with and without each bowtie filter show that some materials for a given design produce bowtie filters that are too large for implementation in breast CT scanners or too small to accurately manufacture. Results also demonstrate the ability to manipulate the energy fluence distribution (dynamic range) by using different materials, or different combinations of materials, for a given bowtie filter design. This feature is especially advantageous when using photon counting detector technology. Monte Carlo simulation results from PENELOPE show that all studied material choices for bowtie design #2 achieve nearly uniform dose distribution, noise uniformity index less than 5%, and nearly uniform scatter-to-primary ratio. These same features can also be obtained using certain materials with bowtie designs #1 and #3. Conclusions: With the three bowtie filter designs used in this work, the selection of material is an important design consideration. An appropriate material choice can improve image quality, dose uniformity, and dynamic range.

60 APPLIED LIFE SCIENCES↗

Theory of Photoluminescence Spectral Line Shapes of Semiconductor Nanocrystals

Single-molecule photoluminescence (PL) spectroscopy of semiconductor nanocrystals (NCs) reveals the nature of exciton–phonon interactions in NCs. Understanding the homogeneous spectral line shapes and their temperature dependence remains an open problem. Here, we develop an atomistic model to describe the PL spectrum of NCs, accounting for excitonic effects, phonon dispersion relations, and exciton–phonon couplings. We validate our model using single-NC measurements on CdSe/CdS NCs from T = 4 to 290 K, and we find that the slightly asymmetric main peak at low temperatures is comprised of a narrow zero-phonon line (ZPL) and acoustic phonon sidebands. Furthermore, we identify the specific phonon modes that give rise to the optical phonon sidebands. At temperatures above 200 K, the spectral line width shows a stronger dependence upon the temperature, which we demonstrate to be correlated with higher order exciton–phonon couplings. We also identify the line width dependence upon reorganization energy, NC core sizes, and shell thicknesses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Local Environment and Interactions of Liquid and Solid Interfaces Revealed by Spectral Line Shape of Surface Selective Nonlinear Vibrational Probe

Vibrational spectral lineshape contains important detailed information of molecular vibration and reports its specific interactions and couplings to its local environment. In this work, recently developed sub-1 cm-1 high-resolution broadband sum frequency generation vibrational spectroscopy (HR-BB-SFG-VS) was used to measure the -C≡N stretch vibration in the 4-n-octyl-4’-cyanobiphenyl (8CB) Langmuir or Langmuir-Blodgett (LB) monolayer as a unique vibrational probe, and the spectral lineshape analysis revealed the local environment and interactions at the air/water, air/glass, air/calcium fluoride and air/-quartz interfaces for the first time. The 8CB Langmuir or LB film is uniform and the vibrational spectral lineshape of its -C≡N group has been well characterized, making it a good choice as the surface vibrational probe. Lineshape analysis of the 8CB -C≡N stretch SFG vibrational spectra suggests the coherent vibrational dynamics and the structural and dynamic inhomogeneity of the -C≡N group at each interface are uniquely different. In addition, it is also found that there are significantly different roles for water molecules in the LB films on different substrate surfaces. These results demonstrated the novel capabilities of the surface nonlinear spectroscopy in characterization and in understanding the specific structures and chemical interactions at the liquid and solid interfaces in general.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detection of Low-energy Breaks in Gamma-Ray Burst Prompt Emission Spectra

The radiative process responsible for gamma-ray burst (GRB) prompt emission has not been identified yet. If dominated by fast-cooling synchrotron radiation, the part of the spectrum immediately below the νF{sub ν} peak energy should display a power-law behavior with slope α{sub 2}=−3/2, which breaks to a higher value α{sub 1}=−2/3 (i.e., to a harder spectral shape) at lower energies. Prompt emission spectral data (usually available down to ∼10--20 keV) are consistent with one single power-law behavior below the peak, with typical slope 〈α〉=−1, higher than (and then inconsistent with) the expected value α{sub 2}=−3/2. To better characterize the spectral shape at low energy, we analyzed 14 GRBs for which the Swift X-ray Telescope started observations during the prompt. When available, Fermi-GBM observations have been included in the analysis. For 67% of the spectra, models that usually give a satisfactory description of the prompt (e.g., the Band model) fail to reproduce the 0.5–1000 keV spectra: low-energy data outline the presence of a spectral break around a few keV. We then introduce an empirical fitting function that includes a low-energy power law α{sub 1}, a break energy E{sub break}, a second power law α{sub 2}, and a peak energy E{sub peak}. We find 〈α{sub 1}〉=−0.66 (σ=0.35), 〈log(E{sub break}/ keV)〉=0.63 (σ=0.20), 〈α{sub 2}〉=−1.46 (σ=0.31), and 〈log(E{sub peak}/ keV)〉=2.1 (σ=0.56). The values 〈α{sub 1}〉 and 〈α{sub 2}〉 are very close to expectations from synchrotron radiation. In this context, E{sub break} corresponds to the cooling break frequency. The relatively small ratio E{sub peak}/E{sub break}∼30 suggests a regime of moderately fast cooling, which might solve the long-lasting problem of the apparent inconsistency between measured and predicted low-energy spectral index.

79 ASTRONOMY AND ASTROPHYSICS↗

A physically based model of the ionizing radiation from active galaxies for photoionization modeling

We present a simplified model of active galactic nucleus (AGN) continuum emission designed for photoionization modeling. The new model oxaf reproduces the diversity of spectral shapes that arise in physically based models. We identify and explain degeneracies in the effects of AGN parameters on model spectral shapes, with a focus on the complete degeneracy between the black hole mass and AGN luminosity. Our reparametrized model oxaf removes these degeneracies and accepts three parameters that directly describe the output spectral shape: the energy of the peak of the accretion disk emission E{sub peak}, the photon power-law index of the non-thermal emission Γ, and the proportion of the total flux that is emitted in the non-thermal component p{sub NT}. The parameter E{sub peak} is presented as a function of the black hole mass, AGN luminosity, and “coronal radius” of the optxagnf model upon which oxaf is based. We show that the soft X-ray excess does not significantly affect photoionization modeling predictions of strong emission lines in Seyfert narrow-line regions. Despite its simplicity, oxaf accounts for opacity effects where the accretion disk is ionized because it inherits the “color correction” of optxagnf. We use a grid of mappings photoionization models with oxaf ionizing spectra to demonstrate how predicted emission-line ratios on standard optical diagnostic diagrams are sensitive to each of the three oxaf parameters. The oxaf code is publicly available in the Astrophysics Source Code Library.

79 ASTRONOMY AND ASTROPHYSICS↗

DIAGNOSTIC LINE EMISSION FROM EXTREME ULTRAVIOLET AND X-RAY-ILLUMINATED DISKS AND SHOCKS AROUND LOW-MASS STARS

Extreme ultraviolet (EUV; 13.6 eV <h{nu} {approx}< 100 eV) and X-rays in the 0.1-2 keV band can heat the surfaces of disks around young, low-mass stars to thousands of degrees and ionize species with ionization potentials greater than 13.6 eV. Shocks generated by protostellar winds can also heat and ionize the same species close to the star/disk system. These processes produce diagnostic lines (e.g., [Ne II] 12.8 {mu}m and [O I] 6300 A) that we model as functions of key parameters such as EUV luminosity and spectral shape, X-ray luminosity and spectral shape, and wind mass loss rate and shock speed. Comparing our models with observations, we conclude that either internal shocks in the winds or X-rays incident on the disk surfaces often produce the observed [Ne II] line, although there are cases where EUV may dominate. Shocks created by the oblique interaction of winds with disks are unlikely [Ne II] sources because these shocks are too weak to ionize Ne. Even if [Ne II] is mainly produced by X-rays or internal wind shocks, the neon observations typically place upper limits of {approx}<10{sup 42} s{sup -1} on the EUV photon luminosity of these young low-mass stars. The observed [O I] 6300 A line has both a low velocity component (LVC) and a high velocity component. The latter likely arises in internal wind shocks. For the former we find that X-rays likely produce more [O I] luminosity than either the EUV layer, the transition layer between the EUV and X-ray layer, or the shear layer where the protostellar wind shocks and entrains disk material in a radial flow across the surface of the disk. Our soft X-ray models produce [O I] LVCs with luminosities up to 10{sup -4} L{sub sun}, but may not be able to explain the most luminous LVCs.

79 ASTRONOMY AND ASTROPHYSICS↗

THE EFFECT OF BLAZAR SPECTRAL BREAKS ON THE BLAZAR CONTRIBUTION TO THE EXTRAGALACTIC GAMMA-RAY BACKGROUND

The spectral shapes of the contributions of different classes of unresolved gamma-ray emitters can provide insight into their relative contributions to the extragalactic gamma-ray background (EGB) and the natures of their spectra at GeV energies. We calculate the spectral shapes of the contributions to the EGB arising from BL Lac objects and flat-spectrum radio quasars assuming blazar spectra can be described as broken power laws. We fit the resulting total blazar spectral shape to the Fermi Large Area Telescope measurements of the EGB, finding that the best-fit shape reproduces well the shape of the Fermi EGB for various break scenarios. We conclude that a scenario in which the contribution of blazars is dominant cannot be excluded on spectral grounds alone, even if spectral breaks are shown to be common among Fermi blazars. We also find that while the observation of a featureless (within uncertainties) power-law EGB spectrum by Fermi does not necessarily imply a single class of contributing unresolved sources with featureless individual spectra, such an observation and the collective spectra of the separate contributing populations determine the ratios of their contributions. As such, a comparison with studies including blazar gamma-ray luminosity functions could have profound implications for the blazar contribution to the EGB, blazar evolution, and blazar gamma-ray spectra and emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Determination of β -decay feeding patterns of 88 Rb and 88 Kr using the Modular Total Absorption Spectrometer at ORNL HRIBF

We report precise determination of ground-state feeding in the β decay of fission products is an important but challenging component in modeling reactor antineutrino flux and reactor decay heat. The Modular Total Absorption Spectrometer (MTAS) is a versatile NaI(Tl) detector array that determines the true β-decay pattern free from the pandemonium effect, including precise ground-state feeding intensities. In this paper, we report MTAS results of the β feeding intensities of 88 Rb and 88 Kr, fission products with large cumulative yields in nuclear reactors. By comparing MTAS results with previous measurements, 88 Rb provides a validation of MTAS's ability to determine ground-state feedings in β decays, while the precision of 88 Kr ground-state feeding is improved when compared with the Evaluated Nuclear Structure Data File (ENSDF). The investigation of sources that contribute to β feeding branching uncertainties in MTAS experiments is discussed in detail. Lastly, the deconvolution of 88 Rb decay spectra suggests that MTAS can distinguish an allowed β spectral shape from a first forbidden unique β spectral shape.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Systems and methods for selective detection and imaging in coherent Raman microscopy by spectral excitation shaping

A microscopy imaging system is disclosed that includes a light source system, a spectral shaper, a modulator system, an optics system, an optical detector and a processor. The light source system is for providing a first train of pulses and a second train of pulses. The spectral shaper is for spectrally modifying an optical property of at least some frequency components of the broadband range of frequency components such that the broadband range of frequency components is shaped producing a shaped first train of pulses to specifically probe a spectral feature of interest from a sample, and to reduce information from features that are not of interest from the sample. The modulator system is for modulating a property of at least one of the shaped first train of pulses and the second train of pulses at a modulation frequency. The optical detector is for detecting an integrated intensity of substantially all optical frequency components of a train of pulses of interest transmitted or reflected through the common focal volume. The processor is for detecting a modulation at the modulation frequency of the integrated intensity of substantially all of the optical frequency components of the train of pulses of interest due to the non-linear interaction of the shaped first train of pulses with the second train of pulses as modulated in the common focal volume, and for providing an output signal for a pixel of an image for the microscopy imaging system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Component separation of a isotropic Gravitational Wave Background

A Gravitational Wave Background (GWB) is expected in the universe from the superposition of a large number of unresolved astrophysical sources and phenomena in the early universe. Each component of the background (e.g., from primordial metric perturbations, binary neutron stars, milli-second pulsars etc.) has its own spectral shape. Many ongoing experiments aim to probe GWB at a variety of frequency bands. In the last two decades, using data from ground-based laser interferometric gravitational wave (GW) observatories, upper limits on GWB were placed in the frequency range of 0∼ 50−100 Hz, considering one spectral shape at a time. However, one strong component can significantly enhance the estimated strength of another component. Hence, estimation of the amplitudes of the components with different spectral shapes should be done jointly. Here we propose a method for 'component separation' of a statistically isotropic background, that can, for the first time, jointly estimate the amplitudes of many components and place upper limits. The method is rather straightforward and needs negligible amount of computation. It utilises the linear relationship between the measurements and the amplitudes of the actual components, alleviating the need for a sampling based method, e.g., Markov Chain Monte Carlo (MCMC) or matched filtering, which are computationally intensive and cumbersome in a multi-dimensional parameter space. Using this formalism we could also study how many independent components can be separated using a given dataset from a network of current and upcoming ground based interferometric detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

The hard X-ray continuum of Cen a observed with INTEGRAL SPI

We revisit the average hard X-ray spectrum from the active galactic nucleus (AGN) of Centaurus A (Cen A) using 10 yr worth of observations with INTEGRAL SPI. This source has the highest flux observed from any AGNs in the SPI bandpass (23 keV-8 MeV). The 10 year light curve of Cen A is presented, and hardness ratios confirm that the spectral shape changes very little despite the luminosity varying by a factor of a few. Primarily, we establish the presence of a reflection component in the average spectrum by demonstrating an excess between 20 and 60 keV, from extending the spectral shape observed at low energy to the SPI regime. The excess in Chandra HETGS and INTEGRAL SPI data is well described by reflection of the dominant power-law spectrum from a neutral, optically thick atmosphere. We find that the reprocessed emission contributes 20%-25% of the 23-100 keV flux. The existence of a cutoff at tens to hundreds of kiloelectron volts remains controversial. Using simulated spectra, we demonstrate that a high energy cutoff reproduces the observed spectral properties of Cen A more readily than a simple power law. However, we also show that such a cutoff is probably underestimated when neglecting (even modest) reflection, and for Cen A would be at energies >700 keV, with a confidence of >95%. This is atypically high for thermal Comptonizing plasmas observed in AGNs, and we propose that we are in fact modeling the more gradual change in spectral shape expected of synchrotron self-Compton spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Near-resonant propagation of short pulses in a two-level medium

We present a numerical method for solving the Maxwell-Bloch equations describing pulse propagation for a two-level medium. The method is accurate, efficient, stable, and well suited for this type of simultaneous equations. By applying the numerical scheme we investigate the evolutions of pulse area, pulse propagation, pulse velocity, and spectral shapes under both homogeneous and inhomogeneous broadening conditions. The results show that the area evolution and pulse-reshaping procedure are significantly influenced by detuning and inhomogeneous line shape, which also impact the oscillation tail and pulse peak. In addition, the pulse-peak traces indicated the pulse velocity always increases with greater deviation in pulse-area value from the value 2{pi}. We also demonstrate the pulse velocity increased for a larger detuning or a wider inhomogeneous line shape. Furthermore, the spectral feature shows that pulse spectra evolve into an oscillating shape.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CORONAL FOURIER POWER SPECTRA: IMPLICATIONS FOR CORONAL SEISMOLOGY AND CORONAL HEATING

The dynamics of regions of the solar corona are investigated using Atmospheric Imaging Assembly 171 Å and 193 Å data. The coronal emission from the quiet Sun, coronal loop footprints, coronal moss, and from above a sunspot is studied. It is shown that the mean Fourier power spectra in these regions can be described by a power law at lower frequencies that tails to a flat spectrum at higher frequencies, plus a Gaussian-shaped contribution that varies depending on the region studied. This Fourier spectral shape is in contrast to the commonly held assumption that coronal time series are well described by the sum of a long timescale background trend plus Gaussian-distributed noise, with some specific locations also showing an oscillatory signal. The implications of the observed spectral shape on the fields of coronal seismology and the automated detection of oscillations in the corona are discussed. The power-law contribution to the shape of the Fourier power spectrum is interpreted as being due to the summation of a distribution of exponentially decaying emission events along the line of sight. This is consistent with the idea that the solar atmosphere is heated everywhere by small energy deposition events.

79 ASTRONOMY AND ASTROPHYSICS↗