Search NASA⌕ Search

SEARCH · Search NASA

Results for “Stark effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Quantum confined Stark effect in Gaussian quantum wells: A tight-binding study

The main characteristics of the quantum confined Stark effect (QCSE) are studied theoretically in quantum wells of Gaussian profile. The semi-empirical tight-binding model and the Green function formalism are applied in the numerical calculations. A comparison of the QCSE in quantum wells with different kinds of confining potential is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Valley-selective optical Stark effect of exciton-polaritons in a monolayer semiconductor

Selective breaking of degenerate energy levels is a well-known tool for coherent manipulation of spin states. Though most simply achieved with magnetic fields, polarization-sensitive optical methods provide high-speed alternatives. Exploiting the optical selection rules of transition metal dichalcogenide monolayers, the optical Stark effect allows for ultrafast manipulation of valley-coherent excitons. Compared to excitons in these materials, microcavity exciton-polaritons offer a promising alternative for valley manipulation, with longer lifetimes, enhanced valley coherence, and operation across wider temperature ranges. Here, we show valley-selective control of polariton energies in WS 2 using the optical Stark effect, extending coherent valley manipulation to the hybrid light-matter regime. Ultrafast pump-probe measurements reveal polariton spectra with strong polarization contrast originating from valley-selective energy shifts. This demonstration of valley degeneracy breaking at picosecond timescales establishes a method for coherent control of valley phenomena in exciton-polaritons.

36 MATERIALS SCIENCE↗

Note: Spectral motional Stark effect diagnostic for measurement of magnetic fields below 0.3 T

The paper reports on development of the spectral motional Stark effect (MSE) diagnostic in the midplane of the gas dynamic trap (GDT) linear system for magnetic confinement of anisotropic hot-ion plasma. The axially symmetric GDT vacuum magnetic field has a minimum value in the midplane, which varies from 0.2 to 0.35 T in different regimes of operation. Buildup of 15 keV ion population generates a diamagnetic reduction of magnetic field in the plasma core of up to 30% in the maximum density region, as measured by the existing eight-line MSE diagnostic. Commissioning of the midplane MSE provided first direct measurements of diamagnetic modifications in the minimum magnetic field GDT section, a necessary complement to the understanding of equilibrium and self-organization of high-β plasmas in GDT. Making use of the stable short-pulse diagnostic beam and calibration of the apparent spectral width of beam emission lines allow for the measurement of the plasma magnetic field of 0.29 ± 0.007 T with the integration time of 200 μs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the Quantum-Confined Stark Effect in Semiconductor Quantum Dots and Nanorods for Single-Molecule Electrophysiology

We optimized the performance of quantum-confined Stark effect (QCSE)-based voltage nanosensors. A high-throughput approach for single-particle QCSE characterization was developed and utilized to screen a library of such nanosensors. Type-II ZnSe/CdS-seeded nanorods were found to have the best performance among the different nanosensors evaluated in this work. The degree of correlation between intensity changes and spectral changes of the exciton's emission under an applied field was characterized. An upper limit for the temporal response of individual ZnSe/CdS nanorods to voltage modulation was characterized by high-throughput, high temporal resolution intensity measurements using a novel photon-counting camera. The measured 3.5 μs response time is limited by the voltage modulation electronics and represents ~30 times higher bandwidth than needed for recording an action potential in a neuron.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stark-effect modulation of a CO2 laser by NH2D.

Use of the molecular Stark effect in NH2D to modulate the 10.6-micron P(20) line of a CO2 laser, yielding a modulation depth of 40% from a 200-V/cm rms signal applied to a 19.7-cm gas cell external to the laser. NH2D was prepared by mixing ND3 and NH3. The absorption coefficient of the M = 4 Stark-split line was measured as a function of mixing ratio and pressure. The observed pressure-broadening coefficient was 32.5 MHz/torr.

Johnston, A. R.↗

Intrashot motional Stark effect calibration technique for lower hybrid current drive experiments

The spurious drift in pitch angle of order several degrees measured by the motional Stark effect (MSE) diagnostic in the Alcator C-Mod tokamak over the course of an experimental run day has precluded direct utilization of independent absolute calibrations. Recently, the underlying cause of the drift has been identified as thermal stress-induced birefringence in a set of in-vessel lenses. The shot-to-shot drift can be avoided by using MSE to measure only the change in pitch angle between a reference phase and a phase of physical interest within a single plasma discharge. This intrashot calibration technique has been applied to the lower hybrid current drive (LHCD) experiments and the measured current profiles qualitatively demonstrate several predictions of LHCD theory such as an inverse dependence of current drive efficiency on the parallel refractive index and the presence of off-axis current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The motional Stark effect diagnostic for ITER using a line-shift approach

The United States has been tasked with the development and implementation of a motional Stark effect (MSE) system on ITER. In the harsh ITER environment, MSE is particularly susceptible to degradation, as it depends on polarimetry, and the polarization reflection properties of surfaces are highly sensitive to thin film effects due to plasma deposition and erosion of a first mirror. Here we present the results of a comprehensive study considering a new MSE-based approach to internal plasma magnetic field measurements for ITER. The proposed method uses the line shifts in the MSE spectrum (MSE-LS) to provide a radial profile of the magnetic field magnitude. To determine the utility of MSE-LS for equilibrium reconstruction, studies were performed using the ESC-ERV code system. A near-term opportunity to test the use of MSE-LS for equilibrium reconstruction is being pursued in the implementation of MSE with laser-induced fluorescence on NSTX. Though the field values and beam energies are very different from ITER, the use of a laser allows precision spectroscopy with a similar ratio of linewidth to line spacing on NSTX as would be achievable with a passive system on ITER. Simulation results for ITER and NSTX are presented, and the relative merits of the traditional line polarization approach and the new line-shift approach are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of an electro-optic modulator based on the quantum-confined Stark effect in a two-layer InAlGaAs rib waveguide on an InP substrate

An electro-optic Mach – Zehnder modulator based on the quantum-confinement Stark effect in layered multiple-quantum-well InAlGaAs structures on InP substrate is numerically simulated. The novelty of the modulator design is the use of a two-layer rib optical waveguides, which provide technologically efficient (loss of 1.5 dB per element) coupling of the modulator with optical fibre. It is shown that, changing the electrode width and the distance between two waveguides in two Mach – Zehnder interferometer arms, one can match the impedance of the modulator with an external 50-Ω load and the velocities of microwave and optical waves in the modulator. The results of the study can be used in integrated optics, optical communication, and radiophotonics devices. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A high spatial resolution Stokes polarimeter for motional Stark effect imaging

We describe an enhanced temporally switched interfero-polarimeter that has been successfully deployed for high spatial resolution motional Stark effect imaging on the KSTAR superconducting tokamak. The system utilizes dual switching ferroelectric liquid crystal waveplates to image the full Stokes vector of elliptically polarized and Doppler-shifted Stark-Zeeman Balmer-alpha emission from high energy neutral beams injected into the magnetized plasma. We describe the optical system and compare its performance against a Mueller matrix model that takes account of non-ideal performance of the switching ferro-electric liquid crystal waveplates and other polarizing components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time data processing and magnetic field pitch angle estimation of the JET motional Stark effect diagnostic based on Kalman filtering

A novel technique for the real-time measurement of the magnetic field pitch angle in JET discharges using the motional Stark effect diagnostic is presented. Kalman filtering techniques are adopted to estimate the amplitude of the avalanche photodiode signals' harmonics that are relevant for the pitch angle calculation. The proposed technique {l_brace}for extended technical details of the generic algorithm see [R. Coelho and D. Alves, IEEE Trans. Plasma Sci. 37, 164 (2009)]{r_brace} is shown to be much more robust and provides less noisy estimates than an equivalent lock-in amplifier scheme, in particular when dealing with edge localized modes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved spectral analysis for the motional Stark effect diagnostic

The magnetic pitch angle and the magnitude from reversed field pinch plasmas in the Madison symmetric torus (MST) have been routinely obtained from fully resolved motional Stark effect (MSE) spectrum analyses. Recently, the spectrum fit procedure has been improved by initializing and constraining the fit parameters based on the MSE model in the atomic data and analysis structure. A collisional-radiative model with level populations nlm-resolved up to n= 4 and a simple Born approximation for ion-impact cross sections is used for this analysis. Measurement uncertainty is quantified by making MSE measurements with multiple views of a single spatial location, ranging 5%-15% for typical MST operation conditions. A multi-view fit improves the goodness of fit of MSE spectral features and background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-screening of the quantum confined Stark effect by the polarization induced bulk charges in the quantum barriers

InGaN/GaN light-emitting diodes (LEDs) grown along the polar orientations significantly suffer from the quantum confined Stark effect (QCSE) caused by the strong polarization induced electric field in the quantum wells, which is a fundamental problem intrinsic to the III-nitrides. Here, we show that the QCSE is self-screened by the polarization induced bulk charges enabled by designing quantum barriers. The InN composition of the InGaN quantum barrier graded along the growth orientation opportunely generates the polarization induced bulk charges in the quantum barrier, which well compensate the polarization induced interface charges, thus avoiding the electric field in the quantum wells. Consequently, the optical output power and the external quantum efficiency are substantially improved for the LEDs. The ability to self-screen the QCSE using polarization induced bulk charges opens up new possibilities for device engineering of III-nitrides not only in LEDs but also in other optoelectronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preparations for the motional Stark effect diagnostic on EAST

Measurement and control of the current profile is essential for high performance and steady state operation of Experimental Advanced Superconducting Tokamak (EAST). For this purpose, a conventional Motional Stark Effect (MSE) diagnostics utilizing photoelastic modulators is proposed and investigated. The pilot experiment includes one channel to verify the feasibility of MSE, whose sightline intersects with Neutral Beam Injection at major radius of R = 2.12 m. A beam splitter is adopted for simultaneous measurements of Stark multiplets and their polarization directions. A simplified simulation code was also developed to explore the Stark splitting spectra. Finally, the filter is optimized based on the viewing geometry and neutral beam parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of motional Stark effect in situ background correction to a superconducting tokamak

A polychrometer-type motional Stark effect (MSE) diagnostic technique, originally developed for the Alcator C-Mod tokamak, has been extended and applied to the Korea Superconducting Advanced Tokamak Research (KSTAR) device, the long-pulse superconducting tokamak, for the first time. It demonstrates a successful in situ subtraction of the polarized reflections off the vacuum vessel wall, sometimes up to half the total signal in some sightlines. To avoid the secondary neutral beam emission that may contaminate conventional beam-into-gas calibrations, a new approach, where the beam-into-gas measurements are made at various torus pressures with fixed vacuum fields, has been devised, which is possible with the stable superconducting coil systems of KSTAR. The validity of this new calibration scheme has been checked via plasma jog experiments. The experimental evidence of the polarized background light and the necessity of its correction in the MSE measurements made in KSTAR are presented as well.

47 OTHER INSTRUMENTATION↗

Measurement of type-I edge localized mode pulse propagation in scrape-off layer using optical system of motional Stark effect diagnostics in JT-60U

Propagation of plasma ejected by type-I edge localized mode (ELM) has been measured in scrape-off layer (SOL) of the JT-60U tokamak, using optical system of motional Stark effect (MSE) diagnostics as beam emission spectroscopy (BES) diagnostics through a new technique developed. This MSE/BES system measures D{alpha} emission from heating neutral beam excited by collisions with the ejected plasma, as well as background light (e.g., bremsstrahlung). While spatio-temporal change in the beam emission gives information on propagation of the ejected plasma, the background light that is observed simultaneously in all spatial channels veils the information. In order to separate the beam emission and the background light, a two-wavelength detector is newly introduced into the MSE/BES system. The detector observes simultaneously at the same spatial point in two distinct wavelengths using two photomultiplier tubes through two interference filters. One of the filters is adjusted to the central wavelength of the beam emission for the MSE diagnostics, and the other is outside the beam emission spectrum. Eliminating the background light, temporal change in the net beam emission in the SOL has been evaluated. Comparing conditionally averaged beam emission with respect to 594 ELMs in a discharge at five spatial channels (0.02-0.3 m outside the main plasma near equatorial plane), radial velocity of the ELM pulse propagation in SOL is evaluated to be 0.8-1.8 km/s ({approx}1.4 km/s for least-mean-squared fitting).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing ITER motional Stark effect line shift (MSE-LS) spectrometers

As a part of ITER beam aided diagnostics, the design of Motional Stark Effect (MSE) diagnostic observing the emission from the Balmer-α line is underway. The physics of Stark splitting shows that the Stark manifold is polarization dependent, and the energy splitting results in a line shift proportional to the electric field. Due to the challenges of maintaining the calibration of the plasma facing mirrors in ITER, the conventional MSE polarimetry measurement technique is replaced with a spectral approach that is deemed more favorable in the ITER environment. The MSE line shift (LS) diagnostic is designed to quantify the Lorentz electric field magnitude by measuring the Stark manifold using visible spectroscopy. In the presence of large magnetic fields and high energy heating beams of 1 MeV, the expected Stark splitting is much larger than in typical devices. The MSE-LS design has unique challenges requiring careful consideration and modeling of its viewing geometry and photon budget. The MSE-LS approach on ITER is promising but has stringent demands on the allowable errors for the statistical and systematic fitting uncertainties. In this study, a full system model and numerical simulations of data for each sightline are completed. For a range of optical transmission fractions, photon noise analysis is conducted to determine the statistical uncertainties. This provides guidance on the spectrometer throughput, dispersion at the detector, optics, and other design choices. A conceptual design of a high throughput spectrometer with a volume phase transmission grating is presented.

Instruments & Instrumentation↗

Optical Stark effect in the four-wave mixing and stimulated Raman spectra of N2

The influence of the optical Stark effect on spectral line shapes in four-wave-mixing Raman spectroscopy (FWMRS) and stimulated Raman spectroscopy (SRS) is investigated experimentally and theoretically. Using an experimental setup capable of rapid alternation between the simultaneous measurement of coherent Stokes Raman spectroscopy and inverse Raman spectroscopy at low and high intensities, together with a sophisticated frequency reference scheme, it was possible to perform a rather direct comparison between Stark-broadened and non-Stark-broadened spectra of both classes of Raman spectroscopies. The results demonstrate that SRS spectra show more Stark shift and broadening than their FWMRS counterparts. A discrepancy with theoretical results is pointed out, and an attempt is made to explain it.

Moosmuller, H.↗