Search NASA⌕ Search

SEARCH · Search NASA

Results for “Steam cycling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Ultrasonic measurement of temperature distributions in extreme environments: Electrical power plants testing in utility-scale steam generators

Thermal heterogeneities within energy conversion and storage, material processing, nuclear processes, aerospace, and military applications are often inaccessible to characterization by insertion sensors. When sensor deployment is possible, conventional pointwise temperature probes quickly degrade when inserted into harsh environments typical of such processes. We developed spatially-resolved ultrasonic thermometry to noninvasively measure the spatial distributions of thermal properties in such applications, even when sizable thermal gradients are present. Our method divides the path of ultrasonic propagation into segments bound by echogenic features, which create echoes in pulse-echo mode, encoding the information about interior temperature distributions. We use the acquired ultrasonic responses to estimate the internal temperature distributions by solving an inverse problem or concatenating segmental estimates. This work describes the implementation and industrial testing of the developed method at a coal-fired electrical power generation plant. We inserted an echogenically segmented Inconel 625 waveguide into the combustion zone of the utility-scale boiler and continuously acquired ultrasonic data while keeping sensitive components away from the damaging combustion environment. The accuracy of the time-dependent temperature distributions reconstructed from the ultrasonic measurements was comparable to that of thermocouples. The resiliency of ultrasonic thermometry to harsh combustion conditions was far superior to conventional insertion sensors. The measurements obtained during plant operation captured daily steam generation cycles in response to changing customer demand and intermittent contributions of renewable power sources to the power grid. These measurements have revealed new insights into the relationship between the dynamic power generation load and the conditions inside the steam generator. As a result, the successful industrial testing of spatially-resolved ultrasonic thermometry in solids indicates that the developed technology has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term thermal characterizations in extreme environments.

42 ENGINEERING↗

Flexible Fully-Decoupled Nuclear Plants with Thermal Energy Storage - Technoeconomic Optimization

New nuclear power plants may be one of the technologies for future zero carbon electricity production. These future systems will however also need significant flexibility to cope with fluctuating demand and large share of intermittent renewable supply, rather than running in conventional baseload generation. The present work explores the use of thermal energy storage (TES) as a buffer between the reactor heat and its conversion to electricity, enabling flexible operation of nuclear plants. The focus is on maximizing flexibility, ideally as full decoupling of the nuclear and power cycle islands, as well as on system efficiency in various modes. A system design presented for a high temperature gas cooled reactor (HTGR) presents a slightly complex solution, as separate high- and low-temperature TES systems are required in order to cover the extended temperature range. Although this configuration imposes certain limitations on the discharge system configuration, it also presents the opportunity to design a more efficient system. For this case in particular, a steam reheat cycle is advantageous. Dynamic models were developed for the decoupled system in order to generate insights into aspects of off design operation and system control. A technoeconomic analysis, furthermore, provides sizing and costing of the component, followed by size and dispatch economic optimization considering energy arbitrage. This optimization shows that in all explored markets, the addition of TES system with the proposed configuration results in positive impact on project net present value. Further sensitivity analyses show impact of multiple inputs and possible technical limitations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Ceramic Heat Exchanger for Next-Generation Concentrated Solar Power

The U.S. Department of Energy has identified a third generation of concentrated solar power (Gen3 CSP) technologies to minimize cost of CSP produced electricity. By developing these technologies further, it is forecasted that Gen3 CSP will meet the levelized cost of electricity (LCOE) SunShot target of 6 cents/kWh to compete with dominant, conventional nonrenewable energy sources (1). The focus for advancing CSP systems for Gen3 is to increase overall system efficiency. Thus, reevaluating second-generation systems, superheated steam-turbine power cycles, and implementing more advanced power cycles is essential. Specifically, it has been identified that a supercritical carbon dioxide (sCO 2 ) Brayton cycle can increase the net thermal-to-electric efficiency to over 50% for CSP power tower configurations (2). Compared to conventional superheated steam Rankine cycle systems, more extreme operating conditions are required and pose critical barriers to overcome in the field of materials and manufacturing for Gen3 CSP.

14 SOLAR ENERGY↗

Dynamic optimization and economic evaluation of flexible heat integration in a hybrid concentrated solar power plant

Hybridization of concentrated solar power (CSP) plants provides flexibility in operation that can drastically improve the solar-to-electric (STE) efficiency and levelized cost of electricity (LCOE) relative to standalone CSP plants. Flexible heat integration (FHI) is a novel concept where the collection and integration of CSP within a power plant is modified relative to the amount of solar energy available. FHI improves the thermal efficiency of a hybrid solar tower steam Rankine cycle power plant but leads to increased pumping needs due to continuously elevated molten salt flow rates through the collection system, which can negatively impact STE efficiency. The present work is carried out to maximize the STE efficiency of a hybrid CSP plant utilizing FHI by employing a dynamic optimization framework where a genetic algorithm optimizes the operation of the plant over a given solar irradiance profile. The study concerns a plant hypothetically located in Salt Lake City, Utah. Here, the optimization results confirm the accuracy of a predictive heuristic where the preferred operation of the plant can be estimated relative to local peaks in the incident power generated by the heliostat collection field. The optimized FHI operation demonstrates a yearly STE efficiency of 13.8%, whereas the equivalent base-level hybrid and solar-only plants exhibit solar efficiencies of 13.4% and 11.2%, respectively. Economic analysis shows that FHI reduces yearly natural gas costs, leading to a $\$0.5$/MWh reduction in LCOE relative to the base-level hybrid configuration. Overall, the results show that hybrid FHI schemes exhibit economic benefits along with observed thermodynamic improvements.

14 SOLAR ENERGY↗

Raman spectroscopic characterization of SiO 2 phase transformation and Si substrate stress relevant to EBC performance

To accurately model the long-term durability of environmental barrier coatings (EBCs), a more complete understanding of the phase composition and transformations of the thermally grown oxide SiO 2 (TGO) is desired. For the TGO formed during thermal cycling in steam, cristobalite formation and the subsequent β- to α-cristobalite transformation has been identified as a potentially life-limiting mechanism. In this study, Raman micro-spectroscopy was used to quantify the cristobalite transformation on a polycrystalline Si coupon that was exposed to steam at 1350°C for 100 h. The phase transformation was mapped at 200–260°C on the TGO surface at different ramp rates using a heating stage and a micro-positioning stage. The stress in the Si substrate was also determined using Raman spectroscopy by measuring the stress induced peak shift. The α→β phase transformation produced a 300–500 MPa tensile stress in the Si substrate, which compared well to the stress predicted from the volumetric expansion of the cristobalite. In conclusion, quantifying the phase transformation and residual stress are critical tools in developing the next generation of high performance EBCs.

36 MATERIALS SCIENCE↗

Modeling of Microgrid for Critical Data Center Applications

As part of continuing efforts to develop support, understanding, and infrastructure of data center integration onto the electric grid, our work aims to model and analyze the behavior of data center loads in a microgrid power system. Our model consists of renewable energy sources, batteries, and a nuclear reactor-steam Rankine cycle to power data center loads. The simulation studies investigate the electrical behavior of the microgrid system to assess its ability in supporting large data center electrical demands.

14 - SOLAR ENERGY↗

Hydrogen-Steam Separation Using Mechanical Vapor Recompression Cycle

Solar thermochemical hydrogen and fuel production is a promising pathways for producing sustainable fuels and chemicals. One of the main challenges in the development of these systems is their low steam conversion extent, dictated by its restrictive thermodynamics requiring extremely high temperatures and low oxygen partial pressure to obtain conversions over 10 \%. While condensing the unreacted steam is technically simple, the latent heat is thus lost, which can be larger than the producd hydrogen higher heating value. We propose to use a modified mechanical vapor recompression cycle, allowing to recover the latent heat by compressing the steam-hydrogen mixture prior to the condensation process, thus creating a temperature different between the hot exhaust and cold inlet streams. We show that this method can recover over 90 % of the latent heat, thus increasing the viability of solar thermochemical hydrogen production cycles even under limited conversion conditions.

hydrogen technology↗

Performance and Economic Evaluation of sCO2 Bottoming Cycles for Natural Gas Combined Cycle Plants with Capture

Natural gas combined cycles (NGCCs) with carbon capture are expected to play a significant role in decarbonization of the power generation sector. NGCC plants generally use triple pressure reheat steam Rankine power cycles for the bottoming cycle. Some studies in the literature have investigated the application of recompression and cascade style supercritical CO2 (sCO2) cycles for NGCC bottoming cycle applications but these studies have focused on power plants without carbon capture. However, NGCC plants fitted with post-combustion solvent-based CO2 capture systems will require a significant amount of steam for solvent regeneration and this can have a major impact on the optimal sCO2 bottoming cycle design. This study investigates the performance and economic potential of sCO2 bottoming cycles for H-class gas turbine based NGCC plants with a post-combustion capture system. A portion of the gas turbine exhaust heat is used for generation of steam required for solvent-based capture system while the rest of the waste heat is utilized in an sCO2 bottoming cycle for power generation. Overall, the performance and LCOE of investigated sCO2 bottoming cycles is similar to that of a state-of-the-art triple pressure reheat steam Rankine cycle. As the gas turbine exhaust temperature increases (beyond 630oC), sCO2 bottoming cycles begin to show greater performance and economic benefits compared to a steam Rankine cycle.

Pidaparti, Sandeep↗

Sintering inhibition enables hierarchical porosity with extreme resistance to degradation during redox cycling of Fe-Mo foams

High-temperature (800 ºC) steam-hydrogen redox cycling, relevant to grid-scale energy storage, is studied for iron-based freeze-cast lamellar foams. In contrast to previously studied Fe, Fe-Ni, and Fe-Co foams that rapidly degrade, Fe-25Mo foams feature a much-enhanced structural damage resistance. Utilizing in-situ x-ray diffraction, microscopy, and x-ray tomography, strong sintering inhibition is observed in Fe-Mo foams, creating a hierarchically porous lamellar structure. This leads to (i) wide channels between lamellae, enabling high macroscopic porosity (~78%) which can accommodate gas flow as well as volumetric expansion without lamellar contact, and (ii) microporosity within lamellae, providing additional free volume to accommodate expansion during oxidation, limiting both swelling of the lamellae and the formation of Kirkendall pores. Finally, these combined effects enable a near-complete reversibility of the microstructure during cycling, preventing damage produced via internal lamellar buckling, cracking, contacting and sintering, with a remarkably high porosity (65%) remaining after 50 consecutive redox cycles.

36 MATERIALS SCIENCE↗

Creep Degradation of Austenitic Steels in CO2 Environments

Steels have a proven track record of safe operation in steam power plants for decades. Interest in developing supercritical CO2 power cycles as a more efficient and sustainable alternative to steam cycles has driven a need to understand steel performance in these new environments. In particular, the potential of the high temperature CO2 environment to influence the creep behavior of the steel must be determined. Prior research on this topic between the 1960s and 1980s found conflicting conclusions, but nevertheless raised the possibility that carburization during CO2 exposure may strongly affect the creep behavior. This raises concerns particularly for thin-sectioned components such as compact heat exchangers, where even small rates of carburization can become problematic over long operating lifetimes. To shed light on this issue, this research investigates the creep behavior of austenitic stainless steel 347H and 309H (a higher Cr alternative) at 650°C. Specimens of 0.5, 1.0, and 2.0 mm thickness were tested to further assess the effect of steel thickness. Both steels show a reduction in creep life in CO2 relative to air, with 309H showing slightly better performance than 374H. Analysis is ongoing to determine the reason for degraded creep properties.

Rozman, Kyle A.↗

Creep behavior of austenitic steels in CO2 and the effect of specimen thickness

Steels have a proven track record of safe operation in steam power plants for decades. Interest in developing supercritical CO2 power cycles as a more efficient and sustainable alternative to steam cycles has driven a need to understand steel performance in these new environments. In particular, the potential of the high temperature CO2 environment to influence the creep behavior of the steel must be determined. Prior research on this topic between the 1960s and 1980s found conflicting conclusions, but nevertheless raised the possibility that carburization during CO2 exposure may strongly affect the creep behavior. This raises concerns particularly for thin-sectioned components such as compact heat exchangers, where even small rates of carburization can become problematic over long operating lifetimes. To shed light on this issue, this research investigates the creep behavior of austenitic stainless steel 347H and 309H (a higher Cr alternative) at 650°C. Specimens of 0.5, 1.0, and 2.0 mm thickness were tested to further assess the effect of steel thickness. Both steels show a reduction in creep life in CO2 relative to air, with 309H showing slightly better performance than 374H. Analysis is ongoing to determine the reason for degraded creep properties.

Rozman, Kyle A.↗

Simulation of the supercritical CO 2 recompression Brayton power cycle with a high-temperature regenerator

The supercritical carbon dioxide (sCO 2 ) recompression Brayton cycle promises higher efficiency and lower capital cost than traditional steam Rankine power cycles. However, achieving high efficiency requires large, highly effective recuperators. Regenerators may be a low-cost alternative to printed circuit and micro-tube heat exchangers for recuperation in sCO 2 power cycles. Regenerators are a periodic heat exchanger in which thermal energy is extracted from the hot stream, stored in solid media, and then released to the cold stream at a later time. Fixed bed regenerators with valves to direct fluid are the preferred method for implementing regenerators in power cycles, but the inherently transient nature of these systems has not been characterized for this application. This study presents the simulation of a high-temperature regenerator within a 10 MWe sCO 2 recompression Brayton cycle. A transient, one-dimensional regenerator model presented in a previous study is used to simulate the regenerator. Dynamic heat exchanger models are also developed for the precooler, low-temperature recuperator, and primary heat exchanger, and the compressors and the turbine are modeled with off-design performance maps. We assess two regenerator-valve design options; one for fast switching, and one for reduced flow rate fluctuations. System simulation finds that both designs see significant fluctuations in turbomachinery flow rate, turbomachinery and system power, and regenerator discharge process outlet temperature. While designing the regenerator-valve subsystem for lower fluctuations is possible, the regenerator cold discharge temperature and net power still fluctuate by ±77.6°C and 6%, respectively. Increasing buffer volume is not effective at sufficiently reducing these fluctuations, but adding a packed bed in between the regenerator and the primary heat exchanger can reduce regenerator discharge process outlet temperature fluctuations to 6.4°C. Further reductions could be possible by increasing the size of this packed bed.

42 ENGINEERING↗

Evidence of redox cycling as a sub-mechanism in hydrogen production during ethanol steam reforming over La 0.7 Sr 0.3 MnO 3-x perovskite oxide catalysts

Ethanol steam reforming (ESR) is of societal interest. Here, in this work, experiments were conducted to ascertain if some of the H 2 is produced by a redox cycle involving H 2 O filling oxygen vacancies over reducible oxide catalysts. Redox cycling experiments were performed over La 0.7 Sr 0.3 MnO 3-x (100) in ultra-high vacuum. It was found that H 2 was produced from redox cycling with alternating ethanol and water exposures over La 0.7 Sr 0.3 MnO 3-x (100), with both half-cycles occurring at temperatures ≤800 K. In the first half-cycle, ethanol ‘directly’ reduced the surface to create oxygen vacancies (not by a CO intermediate), and in the second half-cycle water filled oxygen vacancies to make H 2 . The H 2 production during the water exposure has a half-cycle turnover frequency of >3.2 × 10 -2 molecules site -1 s -1 in the temperature range of 700–800 K, which is fast enough to be part of the ESR full catalytic cycle. Flowing both reactant gases together, ethanol and water, over La 0.7 Sr 0.3 MnO 3-x (100) and La 0.7 Sr 0.3 MnO 3-x powders significantly increases hydrogen production compared to pure ethanol. The results suggest that steady state ESR includes a sub-mechanism of ethanol ‘directly’ reducing the surface to create oxygen vacancy, and water filling oxygen vacancy to make some of the H 2 by a Mars van Krevelen type mechanism.

08 HYDROGEN↗

Design analysis of a particle-based thermal energy storage system for concentrating solar power or grid energy storage

Energy storage is becoming indispensable for expanding renewable energy integration, and it is critical to the future low-carbon energy supply. Large-capacity, grid scale energy storage can support the integration of solar and wind power and support grid resilience with the diminishing capacity of baseload fossil power plants. With the development of thermal energy storage (TES) for concentrating solar power systems, standalone TES for grid integration becomes attractive due to the declining renewable generation cost and an increasing need for energy storage. The standalone TES system introduced in this paper can play a big role in the carbon-free energy future with capacity larger than batteries and cost likely lower than other energy storage methods such as pumped storage hydropower and compressed air energy storage, both of which also have geological limitations. To this end, we describe a TES system that uses stable, inexpensive solid particles as a TES media to provide scalable, low cost energy storage. The particle-based TES has the ability to drive various thermal power cycles including conventional steam-Rankine, air Brayton turbine with combined-cycle ability, or the emerging supercritical carbon dioxide Brayton power cycle. This work describes the containment design method including a concrete silo and an internal-insulation layer for the particle-TES system. The economic analysis shows significantly low storage cost when the particle-TES is integrated with Brayton combined-cycle power generation. The paper shows the design approach of the particle-TES system and its economic potential for bulk energy storage. The advantage of the particle-TES system as a promising bulk energy storage method is its ability to economically support dispatchable renewable grid penetration for larger capacity and longer discharging hours than current battery storage technologies.

25 ENERGY STORAGE↗

CSP Gen3: Liquid-Phase Pathway to SunShot

The United States Department of Energy (DOE) established the Concentrating Solar Power Generation 3 (CSP Gen3) program to promote the development of advanced CSP systems capable of producing electricity at a levelized cost of energy (LCOE) less than $60/MWh, based on criteria published in the CSP Gen3 Roadmap and a subsequent funding opportunity announcement (Gen3 FOA). This report documents the progress and potential of the “Liquid Pathway” to meet these objectives. The Liquid Pathway proposes the use of low-cost molten chloride salts for energy storage, mated with an operationally flexible solar receiver that employs liquid-metal sodium for heat capture and transfer to the storage salt. This approach leverages molten-salt technology from the current state-of-the-art CSP power towers embodied by plants such as Gemasolar, Crescent Dunes, Noor III, and the DEWA 700 CSP project. Furthermore, the design builds on the knowledge gained over decades of use of liquid-metal sodium as a high-temperature heat transfer fluid (HTF) in solar tests and nuclear-power applications. The commercial representation of the proposed Gen3 design incorporates a high-efficiency sodium receiver operating at ~740°C, with a liquid-liquid heat exchanger feeding a two-tank, molten-chloride salt storage system. Chloride salt is dispatched to a supercritical CO 2 (sCO 2 ) power cycle to provide electric power to the grid. The design integration is a conceptual match for the current sodium receiver → solar salt storage → steam-Rankine power cycle promoted by developer Vast Solar, which may facilitate commercial acceptance and development.

14 SOLAR ENERGY↗

Technoeconomic Benefits of Film-Forming Amine Products Applied to Steam Surface Condensers

In a conventional Rankine cycle, the majority of power plants employ surface condensers that use pumped cooling water to reject heat from the cycle. In such cases, heat rejection occurs in a shell and tube heat exchanger by film-wise condensation of low-pressure steam on stainless steel, titanium, brass, or copper-nickel tubing. To improve the thermal performance of steam surface condensers, a replenishable film-forming substance (FFS) can be ap-plied to the condenser tubing to promote efficient dropwise condensation. Conventionally, film-forming amine prod-uct (FFAP) coatings protect boiler surfaces from oxidative corrosion, which substantially reduces the operation and maintenance costs. To quantify the technical and economic benefits of FFAP coatings applied to condenser tubing due to the promotion of dropwise condensation, a thermal resistance network model was established. Using a rep-resentative steam surface condenser, the improvements in thermal performance (overall heat transfer coefficient) and process parameters (net plant efficiency, cooling water flowrate, and turbine backpressure) were determined due to the enhancement in the condensation heat transfer coefficient. Experimentally measured condensation heat transfer coefficients for common condenser materials were compared with the modeling results and were found to be within attainable bounds. Lastly, the trend in total heat exchanger cost reduction is generalized to understand the trade-off between reduced surface area for heat rejection and increase in coating application costs for a re-plenishable coating system.

20 FOSSIL-FUELED POWER PLANTS↗

Burst behavior of nuclear grade FeCrAl and Zircaloy-2 fuel cladding under simulated cyclic dryout conditions

A novel experiment to simulate cyclic dryout in boiling water reactors has been developed to better understand the performance of nuclear grade FeCrAl cladding in a BWR during dryout conditions caused by an Anticipated Operational Occurrence or Anticipated Transient Without SCRAM - both of which are Design Basis Accidents. Internally pressurized C26 M FeCrAl alloy cladding and Zircaloy-2 cladding were subjected to rapid 300°-650 °C thermal cycling in a steam environment; actual maximum temperatures were found to vary between materials but were always above 650 °C. In the range of 32–55 MPa hoop stress, Zircaloy-2 cladding burst within 1–16 cycles (about 100 s of dryout duration above 600 °C), while at 76 MPa hoop stress, C26 M cladding remained virtually undeformed after completing 54 cycles (over 1000 s of dryout duration above 600 °C). Higher temperature 300°-700 °C and 300°C–800 °C cycling experiments had to be performed to induce C26 M burst – failure occurred after 20 cycles in the former and during the first cycle in the latter. Zircaloy-2 and C26 M failure criteria were used to generate hoop stress specific dryout lifetimes. Overall, the simulated cyclic dryout experiments show that nuclear grade C26 M cladding has significantly enhanced survivability under dryout conditions relative to Zircaloy-2.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In-situ strain behavior and BISON simulations of Zircaloy cladding subjected to temperature cycling separate-effects tests in a steam environment

Understanding fuel system performance during anticipated transients without scram (ATWSs) in boiling water reactors (BWRs) is necessary for refining current and future safety limits. High-fidelity material models and simulations are fundamental to rigorous assessment of zirconium-based cladding performance. However, experimental thermomechanical data during simulated ATWSs to validate these modes are limited. To provide relevant in-situ data, Zircaloy-4 cladding was subjected to cyclic heating in a steam environment to simulate an out-of-pile BWR ATWS. Digital image correlation was used to capture the cladding strain behavior in-situ for comparison against simulations using the BISON finite element code. Conventional high-temperature models were compared using multiple schemes to gain a better understanding of the applicability of three BISON models to BWR ATWS: (1) the default combination of creep models in BISON, (2) the high-temperature Erbacher model alone, and (3) the low-temperature Limback-Andersson model alone. The cases run with the Limback-Andersson model alone produced the lowest root mean square error (RMSE). The lowest RMSE for the Limback-Andersson model alone was 0.659%, and the highest RMSE reported was 4.22%. A data gap within the model in the temperature regime of interest was also identified, and to account for this gap, the current model in BISON is linearly interpolated between two separate datasets. In conclusion, this evaluation highlights the need to either develop a new model or to improve the existing model to capture transient creep effects resulting from a cyclic temperature transient.

Anticipated transient without SCRAM↗