Search NASA⌕ Search

SEARCH · Search NASA

Results for “Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Southeast Regional CO 2 Utilization and Storage Acceleration Partnership (SECARB-USA): Needs Assessment Framework for Storage Complexes Contributed to EDX (Work Product 2.1.c)

On September 30, 2021, a Needs Assessment Framework for Storage Complexes was completed for the SECARB-USA region by the Southern States Energy Board (SSEB) and The University of Texas at Austin Bureau of Economic Geology (UT-BEG). The Needs Assessment Framework for Storage Complexes documented a region-wide assessment to identify data needed to advance storage projects at sites of relevance to industrial, academic, and government stakeholders. The region-wide assessment addresses the needs of CO2 source, storage, and utilization stakeholders, finance and insurance institutions, state and local government agencies, local stakeholders at prospective storage complexes, environmental non-governmental organizations (NGOs), and others as identified by the Partners. This assessment was tested against various potential storage sites and modified to include site-specific issues, such as surface or pore space rights. The framework was provided to stakeholders for review and then used in other tasks, such as the ML initiative (Subtask 3.4) and storage complex readiness evaluation (Subtask 4.2). In accordance with the SOPO, this assessment satisfied completion of Work Product 2.1.b. The OSTI ID is 3015803, and the DOI link is https://doi.org/10.2172/3015803. On February 28, 2022, SSEB uploaded Work Product 2.1.b to NETL’s Energy Data eXchange (EDX). As such, Work Product 2.1.c is completed as documented below.

42 ENGINEERING↗

System and component development for long-duration energy storage using particle thermal energy storage

Energy storage, at various scales, will be required to maintain reliable power supply from variable renewable resources, and improve grid resilience. Long-duration energy storage (10-100 h) can substitute baseload coal power generation and increase levels of renewable power supply. Thermal energy storage (TES) has siting flexibility and the ability to store a large capacity of energy, and thus it has the potential to meet the needs of long-duration energy storage. Here, a novel TES system was developed by using solid particles as storage media and charging/discharging electricity from renewable power connected via the electric grid. The particle TES uses low-cost silica sand at 30-40$/Ton that is stable at high temperatures of >1,000 degrees C. Thus, the particle TES system has an overall low storage cost and high thermal-power efficiency. Key components of the system were conceptually designed and modeled for their performance. Conversion of electricity to thermal energy using electric heating can achieve a >98% charging efficiency, and the conversion of thermal energy back to electricity uses an air-Brayton combined power cycle with >52% thermal-to-electricity efficiency at >1,170 degrees C to achieve a >50% roundtrip efficiency after subtracting estimated plant parasitic losses. Laboratory-scale prototypes were fabricated and tested to verify their design approaches and operations relevant to product-scale components.

25 ENERGY STORAGE↗

A techno-economic survey of energy storage media for long-duration energy storage applications

Energy storage technologies that can economically store and provide electricity over multi-day and seasonal timescales are likely to be a critical component of a sustainable and resilient energy system. In this analysis, we perform a broad survey of energy storage technologies to find storage media (SM) that are promising for these long-duration energy storage (LDES) applications. The energy capital cost of the SM is identified as a key figure of merit for LDES. We develop a data collection framework to collect material price and physical property data, which are used to calculate the energy capital cost floor for 376 SM. These costs are then compared with cost targets for the LDES applications. The results show a multitude of thermal and chemical SM are economically promising, including some synthetic fuels, sensible thermal, latent thermal, thermochemical, and batteries based on low-cost materials. In contrast, currently deployed energy storage systems such as lithium-ion batteries and pumped hydro storage do not appear to be promising systems for LDES applications.

25 ENERGY STORAGE↗

Analysis of synergies in converting underground storage sites: Natural gas to hydrogen with co-located CO2 storage

This study examines the untapped potential of synergistically converting underground natural gas storage (UGS) into underground hydrogen storage (UHS) with co-located CO2 storage. Current approaches to subsurface storage technology (SST) development often prioritise single-use scenarios, overlooking the benefits of integrating multiple technologies. We investigate converting UGS assets into UHS through gradual cushion-gas injection over multiple years, rather than injecting all cushion gas in the first year, and include on-site CO2 storage to offset site emissions. Mechanistic modelling shows this gradual transition reduces the Levelised Cost of Storage (LCOS) of H2 by 1.2-13.1% while retaining energy output within 3% of the current status quo. We also show that combined UHS and CO2 storage hubs can reduce the LCOS of CO2 by 45-77% for only a 3-10% increase in hydrogen LCOS relative to the status quo. This analysis framework may help future-proof SST sites and support a resilient, economically beneficial energy transition.

Mouli-Castillo, Julien↗

Estimates of Damped Energy Spread and Emittance in a Two Energy Storage Ring Cooler

In this paper we provide estimates of the damped energy spread and emittance in a two-energy storage ring cooler. Two energy storage rings have two loops at markedly different energies, one at low energy and the other at high energy. In a cooling application the low energy ring has a cooling section to cool the ion beam and the high energy ring may have a wiggler section to enhance the damping effect on electron beam. The linear optics in the cooling section is designed to attain the maximum cooling of ion beams. Similarly, the linear optics in the wiggler section is designed to attained the required equilibrium emittance and energy spread. Hence, the radiation events in these two rings are different and independent. Since the values of damped energy spread and emittance depend on a range of parameters related to lattice design and rings energies, we present analytical calculations along with simulation results to estimate the values of damped energy spread and emittance in a two energy storage ring cooler.

Dhital, B.↗

Cost Impacts of Risk-Based Methods for Defining AoR and PISC Duration of a CO 2 Storage Project Using NRAP Tools and FE/NETL CO 2 Saline Storage Cost Model

The purpose of this analysis is to assess the fiscal impact of using risk-based methods to define the area of review (AoR) and post-injection site care (PISC) duration for a geologic carbon dioxide (CO 2 ) storage project. The Office of Fossil Energy (FE)/National Energy Technology Laboratory (NETL) CO 2 Saline Storage Cost Model (“cost model”) was utilized to evaluate CO 2 storage economics in this study. The cost model is a widely used tool for evaluating CO 2 storage costs in geologic settings. It estimates costs for storage operations conducted under compliance to the United States Environmental Protection Agency (EPA) Underground Injection Control (UIC) Class VI regulations. This analysis evaluates and compares the costs of storage (on a first-year break-even dollar per tonne [2018$] basis) at the proposed FutureGen 2.0 site as a case study storage location by implementing different approaches to determine AoR and PISC given the prevailing geologic conditions and injection volume and duration considerations. The approaches include the use of 1) risk-based methods to define AoR and PISC duration, 2) an EPA-approved AoR and PISC documented in the FutureGen 2.0 UIC Class VI permit applications, and 3) cost model default settings that utilize uncertainty multipliers to estimate CO 2 plume and pressure front extent as part of AoR determination, as well as a 50-year PISC default. From all three sources, the AoR and PISC specified in the Class VI permit applications for FutureGen 2.0 were the largest and longest relative to the other two sources.

54 ENVIRONMENTAL SCIENCES↗

Optimal Strategies for Hybrid Battery‐Storage Systems Design

As stationary hybrid energy‐storage systems (HESS) for power systems applications have recently drawn interest due to their enhanced performance and decreasing cost, developing systematic approaches for HESS design while considering controls is gaining traction. Herein, a method is presented to optimally design hybrid battery storage by proposing a mathematical modeling framework, formulated as a mixed integer linear programming model. The optimization is capable of handling multiple subsystems of batteries, considering their economic and technological performance. Decisions involve sizing of the batteries, optimal temporal and strategic dispatch to end uses, and energy sources for charging each battery. The applicability of the model is tested on four case studies for three battery chemistries representing distinct objectives: high‐power, high‐energy, and second life. Compared to traditionally designed battery storage with a homogeneous battery, optimally designed hybrid systems can save 12%–26% of system costs, depending on the nature of the dispatch profile. Findings point to design preference toward the second life battery supplemented with some high‐power or high‐energy battery capacity, or both. With the utilized electricity price structure, customers can experience approximately 10%–35% reduction in their bills.

Koleva, Mariya↗

Hydraulic fracturing to enhance injectivity and storage capacity of CO 2 storage reservoirs: Benefits and risks

Several potential CO 2 storage reservoirs have been found to have insufficient porosity and permeability to support cost effective commercial-scale injection. As a result, the use of hydraulic fracturing to enhance injectivity and storage capacity of CO 2 storage reservoirs was explored. Previous modeling studies indicate that fracturing can increase storage capacity by modest to significant amounts (10%–35%), depending on model assumptions. Simulations completed as part of this study confirm that for a range of horizontal well lengths, number of fractures, fracture geometries, and fracture properties, injectivity is improved and capacity increases by 13%–71% over the base case unfractured vertical well. Intuitively, increasing the well length and number of fractures had a corresponding impact on increased capacity. Here, fracture area (i.e., the fracture height multiplied by its width) was an important parameter for increasing capacity but the specific geometry (e.g., the ratio of height-to-width) was unimportant. The most important aspect that affected capacity was the ability of a fracture to connect high permeability horizontal zones in the reservoir. This would allow a single well to access both layers, thereby maximizing total storage capacity of the reservoir while likely leading to an overall increase of the CO 2 footprint, which is an important consideration for Class VI UIC permitting. The results of this work demonstrate that hydraulic fracturing is an attractive option to consider when faced with an underperforming geologic carbon storage site that is at risk of causing a project to fail.

03 NATURAL GAS↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

Integration of Storage in the DC Link of a Full Converter-Based Distributed Wind Turbine

Energy storage is known to support the dispatchability of variable renewable resources. In this paper, we model a battery energy storage system (BESS) integrated with the DC link of a Type IV full converter-based wind turbine and the necessary controls to achieve efficient dispatch. To support the validation of control methodologies, we build a detailed model of a Type IV research wind turbine at the National Renewable Energy Laboratory (NREL), the Controls Advanced Research Turbine (CART 3), and we integrated a lithium-ion BESS model in grid-following mode into the model. The simulation results illustrate the sizing and control of the DC link-integrated BESS for a given variable wind resource and varying dispatch strategies (i.e., under constant, uncertain, and ramping wind scenarios). The integrated storage can smooth variabilities in distributed wind output, hedge against uncertainties, provide the ramping capability, as well as support stability under voltage and frequency transients. All of these have been illustrated in MATLAB/Simulink.

DC-link voltage↗

Check the Storage Stack: Comparing Behind-the-Meter Energy Storage State Policy Stacks in the United States

A variety of studies and disparate datasets track state energy storage polices, but these datasets do not cover all BTM-related storage policy. Moreover, these databases do not align these policies with the policy stacking framework. Thus, it is unclear what BTM storage policies are adopted across the country, what should comprise a complete storage policy framework or stack, and how states policies compare against that stack. This report addresses this gap in the literature by developing a state policy stack for BTM battery storage that we compare across all fifty states. This first-of-its-kind BTM storage policy stack includes 11 parent policy categories, and 31 associated policies divided across the market preparation, creation, and expansion policy components.

25 ENERGY STORAGE↗

Techno-Economic Analysis for the Addition of Thermal Energy Storage to a Campus With Existing Battery Storage

Rising global temperatures and increasing energy demands pose significant challenges for energy management, particularly in institutional and commercial settings. As cooling needs grow, campuses must balance operational efficiency, cost control, and grid stability. Energy storage solutions, such as thermal energy storage (TES) systems, offer a promising approach to shifting energy consumption from peak to off-peak periods, alleviating peak demand, reducing utility costs, and enhancing grid resilience. When integrated with existing battery energy storage systems (BESS), TES can further optimize load management and improve energy savings, especially in buildings with diverse energy needs. This article presents a techno-economic analysis of integrating a chilled water TES system into the central plant at California State University, Dominguez Hills, which already operates a BESS. We assess three TES sizing strategies—full storage, load leveling, and peak demand limiting—by modeling and simulations based on historical energy loads. Our findings show that we can control TES systems to complement BESS operation, with campus-level load leveling providing the greatest cost savings by reducing peak demands. Furthermore, the study also evaluates the long-term economic viability of TES, considering installation costs, energy savings, and payback periods under varying tariffs. This research offers practical guidance for institutions seeking to enhance energy resilience and reduce operational costs through energy storage solutions.

25 ENERGY STORAGE↗

Mycorrhizal associations of temperate forest seedlings mediate rhizodeposition, but not soil carbon storage, under elevated nitrogen availability

Abstract Tree‐mycorrhizal associations are associated with patterns in nitrogen (N) availability and soil organic matter storage; however, we still lack a mechanistic understanding of what tree and fungal traits drive these patterns and how they will respond to global changes in soil N availability. To address this knowledge gap, we investigated how arbuscular mycorrhizal (AM)‐ and ectomycorrhizal (EcM)‐associated seedlings alter rhizodeposition in response to increased seedling inorganic N acquisition. We grew four species each of EcM and AM seedlings from forests of the eastern United States in a continuously 13 C‐labeled atmosphere within an environmentally controlled chamber and subjected to three levels of 15 N‐labeled fertilizer. We traced seedling 15 N uptake from, and 13 C‐labeled inputs (net rhizodeposition) into, root‐excluded or ‐included soil over a 5‐month growing season. N uptake by seedlings was positively related to rhizodeposition for EcM‐ but not AM‐associated seedlings in root‐included soils. Despite this contrast in rhizodeposition, there was no difference in soil C storage between mycorrhizal types over the course of the experiment. Instead root‐inclusive soils lost C, while root‐exclusive soils gained C. Our findings suggest that mycorrhizal associations mediate tree belowground C investment in response to inorganic N availability, but these differences do not affect C storage. Continued soil warming and N deposition under global change will increase soil inorganic N availability and our seedling results indicate this could lead to greater belowground C investment by EcM‐associated trees. This potential for less efficient N uptake by EcM‐trees could contribute to AM‐tree success and a shift toward more AM‐dominated temperate forests.

Fitch, Amelia A.↗

SMART Task 6: Evaluation of the Costs of Geologic CO2 Storage for the Illinois Basin Decatur Project Site Using the NRAP/SMART Technoeconomic and Liability Evaluation for Storage (TALES) Model

This is a presentation featuring an analysis related to SMART Task 6 in which CO2 storage costs are presented. The National Energy Technology Laboratory has developed the NRAP/SMART Technoeconomic and Liability Evaluation for Storage (TALES) model to provide quantitative cost-based insights to support developers planning CO2 injection and storage projects. TALES calculates the revenues, costs, and financial performance of candidate CO2 saline storage project based on site-specific activity costs and financial parameters. TALES is being integrated as a module pertaining to storage cost as part of the broader SMART Visualization and Decision Support Platform (SVDSP). In this study, the TALES model was applied using real activity cost data associated with the development and operations at the Illinois Basin Decatur Project (IBDP) CO2 storage project site. Scenario analysis was implemented in which crucial operational and cost attributes were varied and the associated cost implications observed. Key results data and project cost summary metrics like first-year breakeven price of CO2 ($/tonne) and net present value (NPV) are presented in similar fashion to how they will appear in the SVDSP.

Vikara, Derek↗

Energy storage systems including thermal storage tanks

Energy storage systems include a heat source and a thermal energy storage system to store thermal energy produced by the heat source. The thermal energy storage system includes a first tank containing a first salt having a first melting temperature and a second tank containing a second salt having a second melting temperature. At least one input conduit is configured for transferring thermal energy from the heat source to the first tank and second tank. A first output conduit is in thermal communication with the first tank. A second output conduit is in thermal communication with the second tank. Additional energy storage systems include a heat booster positioned and configured to add thermal energy to a heated heat transfer fluid prior to reaching a tank containing at least one thermal storage material. Methods include transferring thermal energy from a thermal energy source to a plurality of thermal energy storage tanks.

McKellar, Michael G.↗

Storage Futures Study: Economic Potential of Diurnal Storage in the U.S. Power Sector

We model the evolution of the U.S. electricity sector from 2020 through 2050 and find significant market potential (>125 GW) for diurnal energy storage across all 19 scenarios considered. Most of this storage has 4-6 hours of duration. We find that storage deployment is driven primarily by the combination of capacity value and energy time-shifting value, and that the combination of these value streams is needed for optimal storage deployment to be realized. We also find a strong correlation of PV penetration and storage market potential. Cost and performance metrics in this study focus on Li-ion batteries because the technology has more market maturity than other emerging technologies but results from this study can be generalized to any technologies that meet the cost and performance projections assumed.

25 ENERGY STORAGE↗