Muon-Computed Tomography using POCA Trajectory for Imaging Spent Nuclear Fuel in Dry Storage Casks
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Cosmic ray muon-computed tomography (μCT) is a new imaging modality with unique characteristics that can be particularly important for applications in nuclear proliferation detection and international treaty verification. Using cosmic ray muons for nuclear security presents several potential advantages. Among others, muons are generated naturally in the atmosphere, can penetrate high-density materials, and are freely available. No radiological sources are required and consequently there is no associated radiological dose. Recently, the feasibility of using muons for imaging spent nuclear fuel stored in shielded casks has been explored and has been proved beneficial. However, challenges in μCT imaging include low muon flux of ~10,000 muons/m2/min, the effects of multiple Coulomb scattering (MCS) blurring the image, and inefficiency in being able to use all recorded muons for imaging. In this paper, we argue that the use of muon tracing should produce tomographic muon images with improved quality – or more quickly for the same image quality – compared to the case where conventional methods are used. In our paper, we report on the development and assessment of a novel muon tracing method for μCT. The proposed method back projects the muon’s scattering angle into each pixel crossed by its PoCA trajectory then forward projects the variance of the scattering angle in each pixel to detector bins along the muon’s incident horizontal direction. Two scenarios were simulated to assess the expected detection capability of this proposed method. GEANT4 was used to model the main characteristics of 1-60 GeV muons through matter. The simulated images showed an expected improvement in resolution and a reduced the reliance on the muon momentum information compared to a more conventional muon tomography method.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
When the fuel in a nuclear reactor no longer contributes efficiently to power production, it is discharged and stored onsite in a water-filled spent fuel pool. When nuclear power plants in the United States were originally designed, it was expected that onsite storage would be temporary. The used nuclear fuel, also known as spent nuclear fuel (SNF), was to be removed from the storage pools after only a few years of cooling and sent for reprocessing. However, commercial reprocessing was not implemented in the United States, and utility spent fuel pools began running out of room. In order to continue power production, nuclear utilities began expanding onsite fuel storage capacities, first by increasing the density of fuel in the fuel pool racks, and then by developing and implementing dry storage casks. The dry storage casks are stored onsite by each utility at a licensed and secured independent spent fuel storage installation (ISFSI). Dry storage casks are robust systems typically consisting of a sealed metal cylinder surrounded by a combination of steel and concrete to provide radiation shielding. The first dry storage casks were loaded with SNF in 1986. Currently there are over 3,000 loaded dry storage casks, and approximately 200 new casks are being placed into service annually at operating nuclear power plants nationwide. Multiple nuclear power plant sites in the United States have shut down and completed decommissioning activities except for the removal of fuel in dry storage. Eventually, the 75,000+ tons of discharged SNF at more than 70 secured locations will need to be safely and securely transported to a new location(s) for eventual disposition. The continued safety and security of this material must be assured.
Safe storage of spent nuclear fuel (SNF) is critical to the nuclear fuel cycle and the future of nuclear energy. In the United States, SNF is stored primarily via two methods regulated by the U.S. Nuclear Regulatory Commission: wet storage in SNF pools and dry storage in dry cask storage systems (DCSSs). After about five years of cooling in spent fuel pools, the fuel assemblies are transferred into DCSSs, and the systems are filled with helium and sealed by welding. Deterioration of conditions inside of a DCSS is reflected in changes in the internal gas properties; this motivates the development of acoustic techniques to monitor internal gas properties, over extended storage periods, using sensors mounted on the exterior of the storage packages. However, a major challenge in collecting acoustic signals is the impedance mismatch between the steel canister shell and the gas. Only a small fraction of the ultrasonic signal can be transmitted through the gas medium. This paper documents experimental studies conducted on a full-scale canister mock-up to capture the gas-borne signals. Damping materials were pasted on the outside, and blocking and unblocking tests were conducted to identify the gas-borne signal. The results show that the excitation frequency plays an important role in maximizing the gas-borne signals. The gas-borne signal was successfully detected at around the theoretical time-of-flight. A high signal-to-noise ratio was achieved in the measurements. Next, the acoustic impedance matching layers were introduced, and the gas signal was drastically improved compared with that using no AIM layers.
The thermal performance of a commercial nuclear spent fuel dry storage cask is evaluated through detailed analytical modeling. These modeling efforts are performed by the vendor to demonstrate the performance as well as regulatory compliance and are independently verified by the Nuclear Regulatory Commission (NRC). The majority of commercial dry storage casks in use today are aboveground. Cooling of the assemblies located inside the sealed canister is achieved by naturally-convective air flowing in the bottom of the cask and exiting out the top. Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating design and performance models. Numerous studies have been previously conducted. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. These vertical, canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both above and belowground configurations. While several testing programs have been previously conducted, these earlier validation efforts did not capture the effects of elevated helium pressures or accurately portray the external convection of aboveground and belowground canistered dry cask systems. Thus the enhanced performance of modern dry storage casks cannot be fully validated using previous studies.
The thermal performance of commercial spent nuclear fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission(NRC). Canistered dry storage cask systems rely on ventilation between the inner canister and the overpack to convect heat away from the canister to the surrounding environment for both horizontal and vertical configurations. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. While several testing programs have been previously conducted, these earlier validation studies did not integrate all the physics or components important in a modern, horizontal dry cask system. The purpose of the investigation described in this test plan is to produce data sets that can be used to benchmark the codes and best practices presently used to determine cladding temperatures and induced cooling air flows in modern horizontal dry storage systems. The horizontal dry cask simulator(HDCS) has been designed to generate this benchmark data and add to the existing knowledgebase. The pressure vessel representing the canister has been designed, fabricated, and pressure tested for a maximum allowable pressure(MAWP)rating of 2,400 kPa at400 °C. An existing electrically heated but otherwise prototypic boiling water reactor(BWR), Incoloy-clad test assembly will be deployed inside of a representative storage basket and canister. An insulated sheet metal enclosure will be used to mimic the thermal properties of the concrete vault enclosure used in a modern horizontal storage system. Radial and axial temperature profiles along with induced cooling air flow will be measured for a wide range of decay powers and representative(and higher)cask pressures using various backfills of helium, argon, or air. The single assembly geometry with well-controlled boundary conditions simplifies computational requirements while preserving relevant physics. The proposed test apparatus integrates all the underlying thermal-hydraulics important to defining the performance of a modern horizontal storage system. These include combined-mode heat transfer from the electrically-heated assembly to the canister walls and the primarily natural-convective heat transfer from the canister to the cooling air flow passing through the horizontal vault enclosure. The objective of the HDCS is not to reproduce the performance of a commercial dry storage system for any given set of operational parameters. Rather ,the objective is to capture the dominant physics in a well-characterized test apparatus. The close coupling between the thermal response of the canister system and the resulting induced cooling air flow rate is of particular importance. While incorporating the best available information based on thermal-hydraulic scaling arguments as well as previous vertical testing, this test plan is subject to changes due to improved understanding or from as built deviations to designs. As-built conditions and actual procedures will be documented in the final test report.
The thermal performance of commercial spent nuclear fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Canistered dry storage cask systems rely on ventilation between the inner canister and the overpack to convect heat away from the canister to the surrounding environment for both horizontal and vertical configurations. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a canister in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. Carefully measured data sets generated from testing of full-sized casks or smaller cask analogs are widely recognized as vital for validating these models. While several testing programs have been previously conducted, these earlier validation studies did not integrate all the physics or components important in a modern, horizontal dry cask system. The purpose of the present investigation is to produce data sets that can be used to benchmark the codes and best practices presently used to determine cladding temperatures and induced cooling air flows in modern horizontal dry storage systems. The horizontal dry cask simulator (HDCS) has been designed to generate this benchmark data and add to the existing knowledge base. The objective of the HDCS investigation is to capture the dominant physics of a commercial dry storage system in a well-characterized test apparatus for any given set of operational parameters. The close coupling between the thermal response of the canister system and the resulting induced cooling air flow rate is of particular importance.
Nuclear power is a significant source of electricity in the United States, but the average age of nuclear power plants is around 40 years old. The safe management of the spent nuclear fuel (SNF) is a key aspect of the back-end of the nuclear fuel cycle. Spent fuel dry storage systems are becoming a popular and effective solution in this area, given the absence of a final disposal system. The spent fuel cask system (dry cask method) provides a feasible solution to maintain spent fuel for 60 years before final disposal. Dry cask storage has many characteristics that make it attractive. It fulfills the safety requirements of the Nuclear Regulatory Commission (NRC) while providing modularity and flexibility to contractors. The HI-STORM overpack and MPC-32 canister are the main parts of the HI-STORM 100 dry cask storage system. These components remove heat from the system using natural circulation, requiring no human intervention. This is the characteristic that provides passive heat removal and low maintenance features in dry cask storage systems. To develop a thermal model for a dry cask storage system, the physics behind the system should be defined clearly. There are two natural circulation loops in the system; circulation of helium cools down the nuclear assemblies in the MPC, while circulation of air cools down the walls of the MPC. This work aims to develop a thermal model of the MPC-32 canister and HI-STORM overpack using the Multiphysics Object-Oriented Simulation Environment (MOOSE). MOOSE is an open-source framework developed by Idaho National Laboratory (INL) for multiscale, multiphysics simulations. In this study, we will investigate and demonstrate the thermal-hydraulics modeling capabilities of the MOOSE framework, including natural circulation, heat transfer, and porous flow.
Nuclear power is a significant source of electricity in the United States, but the average age of nuclear power plants is around 40 years old. The safe management of the spent nuclear fuel (SNF) is a key aspect of the back-end of the nuclear fuel cycle. Spent fuel dry storage systems are becoming a popular and effective solution in this area, given the absence of a final disposal system. The spent fuel cask system (dry cask method) provides a feasible solution to maintain spent fuel for 60 years before final disposal. Dry cask storage has many characteristics that make it attractive. It fulfills the safety requirements of the Nuclear Regulatory Commission (NRC) while providing modularity and flexibility to contractors. The HI-STORM overpack and MPC-32 canister are the main parts of the HI-STORM 100 dry cask storage system. These components remove heat from the system using natural circulation, requiring no human intervention. This is the characteristic that provides passive heat removal and low maintenance features in dry cask storage systems. To develop a thermal model for a dry cask storage system, the physics behind the system should be defined clearly. There are two natural circulation loops in the system; circulation of helium cools down the nuclear assemblies in the MPC, while circulation of air cools down the walls of the MPC. This work aims to develop a thermal model of the MPC-32 canister and HI-STORM overpack using the Multiphysics Object-Oriented Simulation Environment (MOOSE). MOOSE is an open-source framework developed by Idaho National Laboratory (INL) for multiscale, multiphysics simulations. In this study, we will investigate and demonstrate the thermal-hydraulics modeling capabilities of the MOOSE framework, including natural circulation, heat transfer, and porous flow.
The processing and storage of nuclear fuel is an ever increasingly pressing issue. Around 70,000 tons of used fuel are currently in either dry or wet storage on site at nuclear power plants or at specified spent fuel storage facilities. Additionally, about 2,000 tons are added to that sum each year. To promote retrievability, limit degradation in the canister, and reduce potential for hydrogen generation, spent fuel that is initially in wet storage must be dried before moving to dry cask storage. Therefore, this research seeks to use a mock used fuel storage cask to replicate the conditions in the industry during the drying process of fuel being moved from storage pools. To simulate this, a mock storage cask has been constructed to closely resemble those used in industry such that any areas that tend to retain water are replicated effectively. It is able to hold one mock used fuel assembly. The assembly used is an AREVA 10A 10 x 10 assembly with 78 rods filled with depleted uranium, 12 heater rods to simulate decay heat, a 3 x 3 BWR water channel, and one interchangeable rod position for tests such as a simulated failed fuel rod, BWR water rod, and PWR guide tube tests. The industry standard procedure is used in drying the assembly which involves stepping the system pressure down and holding for certain periods until reaching 3 torr and holding for 30 minutes. This is believed to sufficiently dry the assembly. The goal is to record data throughout these tests that can provide the industry with a greater understanding of how well the process works. This data will also be used to develop and validate a computer model of the drying process. Mechanistic models are currently under development. Reduced order models are being investigated for incorporation into current related engineering codes such as COBRA-SFS. COBRA-SFS is a member of the COBRA family of codes which is mainly used in the evaluation of thermal hydraulic systems containing spent nuclear fuel. However, it does not currently have the capability to account for processes such as evaporation encountered during drying operations. Therefore, those physical models are to be added to the source code. At present a model of the experiment has been created using the COBRA-SFS Cycle-4 code. A number of steady state models along with transient models have been developed and presented. Each of these yield valuable results for comparison with the experiments conducted. In addition to comparison with experimental results, the data collected from COBRA-SFS is compared with that which has been generated from other computer models which utilize computational fluid dynamics. (authors)