At least 73 records · Page 4

Improvements to CTF Closure Models for Modelling of Two-Phase Flow

This report documents the efforts to improve the CTF prediction of void fraction and two-phase pressure drop by improving two-phase closure models. Previous validation activities have revealed that CTF tends to overpredict void fraction and two-phase pressure drop. In response to this, two approaches were taken to improve CTF’s predictive capabilities. Based on findings that the interfacial drag and subcooled boiling models significantly impact void prediction, alternative closure models for these physical effects were found and implemented into the code. An extensive assessment was performed by using the existing and newly added two-phase experimental data, which showed that void prediction, wall temperature, and two-phase pressure-drop results are improved by using the newly implemented models. A second approach for improving CTF modeling accuracy involved the use of a Bayesian calibration process that uses CTF validation data to optimize selected modeling coefficients and closure model multipliers to achieve a more accurate prediction of experimental results. A similar assessment was performed with calibrated models that improved the void and pressure-drop prediction for test cases that were both included and not included in the calibration dataset. Results of this study will be used to change the models used in CTF to achieve more accurate BWR analyses moving forward. This study also identified opportunities for improving additional closure models and other opportunities to use calibration techniques to improve CTF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

System for cooling hybrid vehicle electronics, method for cooling hybrid vehicle electronics

The invention provides a single radiator cooling system for use in hybrid electric vehicles, the system comprising a surface in thermal communication with electronics, and subcooled boiling fluid contacting the surface. The invention also provides a single radiator method for simultaneously cooling electronics and an internal combustion engine in a hybrid electric vehicle, the method comprising separating a coolant fluid into a first portion and a second portion; directing the first portion to the electronics and the second portion to the internal combustion engine for a time sufficient to maintain the temperature of the electronics at or below 175.degree. C.; combining the first and second portion to reestablish the coolant fluid; and treating the reestablished coolant fluid to the single radiator for a time sufficient to decrease the temperature of the reestablished coolant fluid to the temperature it had before separation.

33 ADVANCED PROPULSION SYSTEMS↗

Validation and Benchmarking of CTF For Single- And Two-Phase Flow Using VIPRE-01

As part of the Consortium for Advanced Simulation of Light Water Reactors (CASL), the subchannel code CTF is being used for single- and two-phase flow analysis under light water reactor operating conditions. Accurate determination of flow distribution, pressure drop, and void content is crucial for prediction of margins to thermal crisis and neutronic feedback, and therefore more efficient plant performance. In preparation for the intended applications, CTF has been validated against experimental facilities comprising the General Electric (GE) 3×3 bundle, the BWR Full-size Fine-mesh Bundle Tests (BFBT), the RISO tube, and the PWR Subchannel and Bundle Tests (PSBT). Meanwhile, the licensed and industrially well-recognized subchannel code VIPRE-01 is used to generate a baseline set of simulations for the targeted tests, and solution parameters are compared to CTF results. The flow split verification problem and single-phase GE 3×3 result in essentially perfect agreement between CTF and VIPRE-01. For two-phase GE 3×3 cases, flow and quality discrepancies arise in the annular-mist flow regime, yet significant improvement is observed in CTF when void drift and two-phase turbulent mixing enhancement are considered. BFBT pressure drop benchmark shows close agreement between predicted and measured results in general, although considerable over-prediction of CTF is observed at relatively high void locations of the facility. This over-estimation tendency is confirmed by RISO cases. While overall statistics are satisfactory, the BFBT bubbly/slug/churn-turbulent flow void contents are markedly over-predicted by CTF, the latter being consistent with PSBT results. Such two-phase closure terms in CTF as turbulent mixing, interfacial and wall friction, and subcooled boiling heat transfer need further improvement using more mechanistic models and high-to-low calibration techniques

Zhao, X↗

System for cooling hybrid vehicle electronics, method for cooling hybrid vehicle electronics

The invention provides a single radiator cooling system for use in hybrid electric vehicles, the system comprising a surface in thermal communication with electronics, and subcooled boiling fluid contacting the surface. The invention also provides a single radiator method for simultaneously cooling electronics and an internal combustion engine in a hybrid electric vehicle, the method comprising separating a coolant fluid into a first portion and a second portion; directing the first portion to the electronics and the second portion to the internal combustion engine for a time sufficient to maintain the temperature of the electronics at or below 175° C.; combining the first and second portion to reestablish the coolant fluid; and treating the reestablished coolant fluid to the single radiator for a time sufficient to decrease the temperature of the reestablished coolant fluid to the temperature it had before separation.

France, David M.↗

Achievements and Ongoing Challenges for advanced CFD Boiling Closure Model Development using Physical Insights from Validation-Oriented High-Fidelity Boiling Experiment

The fundamental understanding of the boiling-associated heat transfer, including sliding bubble effect, is still challenging despite the intensive research for decades in both experimental and computational boiling research communities. One of the main difficulties of boiling experiment come from the fact that direct observation of the underlying principle through experiment is very difficult due to the high complexity of the boiling phenomenon. Also, since the heat transfer characteristics associated with boiling is the result of non-linear interaction of various physical parameters coupled to each other, it is challenging to find the relationship between the parameters for modeling. This paper discusses the authors’ past and ongoing boiling research under CASL (Consortium for Advanced Simulation of Light Water Reactors) program, including the efforts to overcome the difficulties of boiling measurement and model development. In particular, we focus on describing the major achievements, lessons learnt, and ongoing challenges for the CFD boiling closure model development based on the high-fidelity subcooled flow boiling experiment at Texas A&M University (TAMU). The major research achievements discussed through this paper include (i) novel boiling measurement strategy and high-fidelity validation data production, (ii) dedicated effort to identify the critical measurement issues in boiling experiment, (iii) new physical insight into sliding bubble heat transfer mechanisms, and (iv) new boiling closure model development. Discussion is also made on the ongoing challenges for the boiling closure model development and the future research plan based on the lessons learnt.

42 ENGINEERING↗

Boiling Closure Model Validation/Development Effort with TAMU Experimental Data

This report describes a model validation and developmental effort in INL based on the analysis of experimental data taken from TAMU subcooled flow boiling facility. This report first describes briefly the test loop, experimental strategy, measurement techniques, data quality achieved, and test boundary conditions. Then, two main topics are discussed based on the experimental observation, bubble departure frequency and sliding bubble characteristics. The comparison of experimental data with the prediction of bubble departure frequency models shows that the predictive capability of existing models depends strongly on flow conditions. Also, the best performance region of each bubble departure frequency model could be determined from this analysis. Another critical achievement through this study is that the limitation of existing CFD boiling models dealing with sliding bubble effect was clearly identified. Specifically, the experimental observation indicates that the wall area influenced by sliding bubbles is not just a function of bubble size, but also depends strongly on sliding bubble trajectory and sliding distance. As a result, the bubble influence factor ( K ) for the small size of sliding bubbles was often found substantially higher than those reported in literature. In this regard, an effort is currently being made in INL to develop a new model to predict the sliding bubble effect on wall heat transfer based on the insight achieved from TAMU subcooled flow boiling experiment.

42 ENGINEERING↗

Modeling the Effect of Evaporative Flux and Colloidal Aggregation on Crud Deposition

During the last few years lot of research has been conducted to investigate and predict the Crud deposition in PWRs. One of the common findings of various experimental and computational studies is that thickness or amount of crud deposits is directly related to evaporative flux maps. Evaporation driven deposition profile on the surfaces takes different forms, i.e. from ring to disk shapes during initial stages and in the form of porous to impervious continuous layers covering the hot fuel surface at the later stages. The amount and thickness of these deposits although are directly related to evaporative flux, the relationship is much complex and can be dependent upon several other factors. A popular problem relating evaporative flux to particulate deposition has been well studied in the form of drying of sessile colloidal drops. It was proposed that, this phenomenon is due to a geometrical constraint: the free surface, constrained by a pinned contact line squeezes the fluid outwards to compensate for evaporative losses and thereby transporting particles to the contact line. Later on a quantitative relationship between evaporative flux and deposition rate was proposed and validated by the same group, which showed power-law relationship. Deposition studies conducted with controlled concentration of particles with subcooled nucleate boiling also showed a power-law relationship rather than a simpler linear relationship whereas physics of evaporation would tend to concentrate particles at linear rate. In a typical subcooled nucleate boiling system, bubble growth and departure time is of the order 1-2 ms, measured experimentally. Diffusion time constant for dilute spherical metallic colloids such as crud particulates, generally present as particulate in process piping, range from 0.0025-2.5 sec in water for a size range 0.1-1.0 μm. Colloidal behavioral characteristics during the growth of bubbles can be computed with escape time constant at collision, which is dependent on effective Hamaker constant. For minimum effective Hamaker constant of Hematite is -2.5 kT and diffusion time constant τ = 0.0025 sec, escape time constant is computed as Kramer rule, τexp[A/kT] magnitude is 0.03 sec or 30 ms. This clearly indicates that evaporation will cause particles to come together and they cannot escape at a fast enough rate which would lead them to form agglomerates. Therefore both effects of evaporative flux in conjunction with the agglomeration kinetics must be considered for modeling the crud deposition if the evaporative flux is known. In this paper, we propose a phenomenological model of colloidal transport and aggregation with evaporative flux. The dynamic of particles interactions while drying of sessile colloidal drops is developed by coupling general transport equation with Smoluchowshki Coagulation equation. Crud deposition on the nuclear fuel has been a serious problem with severe consequences in nuclear power plants. In several studies it has been consistently reported that crud deposition is directly related to evaporative flux on the nuclear fuel surfaces. However, it has not been established how to quantify the deposition rates of crud type particulates if the evaporative flux is known. This complex multiphysics problem is similar to coffee-ring effect, where the governing physics is understood more clearly. In this work, a simplified geometry is used to model the effects of evaporative flux acting at a boundary on the colloidal concentration. The effect of this condition on change in concentration is shown numerically. Further, agglomeration is suspected to play a significant role in high evaporative flux such as bubble nucleation. The coagulation kinetics is modeled using uniform particle distribution and the effective total concentration of colloids including original particles and agglomerates is studied. Once this model is validated with a simple separate effect experiments, it can be integrated to large scale PWR models of evaluating evaporative flux and chemistry models developed by Electrical Power Research Institute (EPRI). (authors)

42 ENGINEERING↗

Subcooled and saturated water flow boiling pressure drop in small diameter helical coils at low pressure

Experimental pressure drop results on boiling water flow through three helical coils of tube inner diameter of 4.03 mm and 4.98 mm and coil diameter to tube diameter ratio of 26.1, 64.1 and 93.3 are presented. Both subcooled and saturated flow boiling are investigated, covering operating pressures from 120 to 660 kPa, mass fluxes from 290 to 690 kg m{sup -2} s{sup -1} and heat fluxes from 50 to 440 kW m{sup -2}. Existing correlations for subcooled flow pressure drop are found not capable to fit the present subcooled database, while the measurements in saturated flow conditions are successfully reproduced by existing correlations for both straight and coiled pipe two-phase flow. The experimental database is included in tabular form. (author)

42 ENGINEERING↗

The Effect of Support Rod on Film Boiling Heat Transfer for Hot Metal Sphere in Subcooled Water

In fuel-coolant interaction (FCI), the heat transfer of corium has been conventionally evaluated by the correlations with a sphere developed in boiling region for subcooled film. However, these correlations do not give significant consideration on the support rod for the sphere from their developments, although Nishio et al. pointed out that the heat transfer and the vapor film collapsing mode would depend on H/D ratio. In this study, we performed experimental tests with the SS316 sphere (10 mm) and found the noticeable increase on the heat transfer in subcooled film boiling region with the deeper immersion depth and larger diameter of support rod. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Newton-Krylov method in solving drift-flux two-phase flow problems for both pre-CHF and post-CHF conditions at steady state

Furthermore, this paper presents numerical simulations of two-phase flow heat transfer for both pre-CHF and post-CHF conditions typical in light water nuclear reactors. The conjugate heat transfer problem is modeled with one-dimensional drift-flux two-phase flow model for coolant flow and two-dimensional heat conduction equation in solid walls. Fully implicit time integration schemes were employed, and the resulted non-linear equations were solved with a Newton-Krylov method. For the drift-flux two-phase flow model, the EPRI drift-flux closure correlation is used to model the relative motion between the two phases. Additional closure correlations were adopted from REALP5-3D to determine two-phase flow regime, wall boiling heat and mass transfer, interfacial heat and mass transfer, and two-phase flow frictional pressure drop. Three sets of experiments were used for code validation, including Bartolomei subcooled flow boiling in vertical pipes, FRIGG boiling tests in vertical bundles, and Bennett heated tube tests. RELAP5-3D simulation results were also provided to perform code-to-code benchmark. Overall, numerical results of this work showed good agreements with both experimental data and RELAP5-3D simulation results. Discrepancy between them were also identified in post-CHF region, which suggests necessary further improvement.

42 ENGINEERING↗

A User's Guide to the PLTEMP/ANL Code

PLTEMP/ANL V4.2 is a FORTRAN program that obtains a steady-state flow and temperature solution for a nuclear reactor core, or for a single fuel assembly. It is based on an evolutionary sequence of ''PLTEMP'' codes in use at ANL for the past 20 years. Fueled and non-fueled regions are modeled. Each fuel assembly consists of one or more plates or tubes separated by coolant channels. The fuel plates may have one to five layers of different materials, each with heat generation. The width of a fuel plate may be divided into multiple longitudinal stripes, each with its own axial power shape. The temperature solution is effectively 2-dimensional. It begins with a one-dimensional solution across all coolant channels and fuel plates/tubes within a given fuel assembly, at the entrance to the assembly. The temperature solution is repeated for each axial node along the length of the fuel assembly. The geometry may be either slab or radial, corresponding to fuel assemblies made of a series of flat (or slightly curved) plates, or of nested tubes. A variety of thermal-hydraulic correlations are available with which to determine safety margins such as Onset-of- Nucleate boiling (ONB), departure from nucleate boiling (DNB), and onset of flow instability (FI). Coolant properties for either light or heavy water are obtained from FORTRAN functions rather than from tables. The code is intended for thermal-hydraulic analysis of research reactor performance in the sub-cooled boiling regime. Both turbulent and laminar flow regimes can be modeled. Options to calculate both forced flow and natural circulation are available. A general search capability is available (Appendix XII) to greatly reduce the reactor analyst’s time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Frequency spectrum analysis code for nuclear noise based on improved wavelet algorithm - 337

The core of the narrow flow channel generally faced the problem of local bubble boiling with the temperature rise of the nuclear fuel element, it is necessary and meaningful to answer and deal with the problem on the technical level. Reactor noise analysis begins with the study of the physical characteristics of the core, after nearly 30 years of research and development it has become a powerful tool in the auxiliary monitoring of the power reactor operating. By using this noise frequency spectrum analysis technology, the reactor dynamic parameter such as prompt neutron decay constant can be measured. Also, through such system, the frequency characteristics of reactor can be real-time monitored, which is helpful for safety operation and fault diagnosis. Spectrum analysis technology in the Fourier analysis era is now barely available, the reason is that the local spectral characteristics of this technology are not obvious, but this defect can be greatly improved by wavelet analysis technique, however, the traditional wavelet analysis will introduce the problem of spectral confusion. To solve the problem, based on the improved wavelet algorithm, frequency spectrum analysis code for nuclear noise is developed,from the perspective of fine spectral analysis, the local boiling accident of the coolant can be prejudged and avoid. Based on the analysis and test of experimental data,The results show that the calculation ability of the code is in accordance with the expected, it can be applied in the operation of research reactor. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Enhanced numerical design of two-barrier infrared detectors with III–V compounds heterostructures considering the influence of lattice strain and misfit dislocations on the band gap

The goal of this work is the design of efficient infrared radiation detectors based on InAsSb compounds with two energy barriers around the absorber region. Two types of two-barrier detectors that work in the 3–5.5 μm wavelength range at 230 K is designed. Using our computer program to iteratively solve the Poisson equation, the spatial distribution of energy band edges in III–V heterostructures was calculated The influence of lattice stress, bending of the structure and doping on the energy shift of the edge of the bands is considered. Lattice strain is the cause of the formation of the misfit dislocations at the boundaries of the individual layers of the heterostructure. These dislocations partially relax the resulting stress and affect the lattice deformation in individual layers. From the minimum elastic energy condition, the density of these dislocations is determined. It has been shown that the band offset can be eliminated in the areas of both barriers in the designed two-barrier detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flow reversal benchmark of a one-sided heated narrow rectangular channel with CATHARE and RELAP5

Flow reversal in narrow coolant channels can be a crucial phenomenon for the safety of research reactors with a downward nominal flow direction. During a loss of forced flow accident, the downward flow stagnates briefly before transitioning into an upward natural circulation flow. The fuel may be damaged if dryout occurs and threshold fuel and/or cladding temperatures are exceeded. A comprehensive study is provided for flow reversal in narrow rectangular channels by examining experimental data and conducting software model analyses. The literature on flow reversal was reviewed, and selected experimental datasets were used to benchmark against CATHARE and RELAP5 models and also compare the code calculations with each other. The experimental data comes from flow reversal tests conducted with a narrow rectangular channel with one-sided heating. The results were compared with experimental data for successful flow reversal tests and predicted dryout power for dryout conditions. Also, the study examined the effects of the pump coastdown period, inlet liquid temperature, system pressure, and localized pressure drops. The experimental results showed that shorter coastdown periods, reduced pressure drops, and lower coolant inlet temperatures increased the dryout power. However, the system pressure did not noticeably affect the results. The simulation results showed that both CATHARE and RELAP5 agreed with experimental data, capturing the trends of the experimental results. Slight differences between each code calculation, as well as the predicted and measured dryout powers, were attributed to experimental uncertainties and the modeling of physical phenomena such as wall nucleation, interfacial heat transfer, drag coefficients, and critical heat flux. Overall, this study provides an understanding of flow reversal and the prediction capabilities of thermal-hydraulics software models. In conclusion, a future study of the flow reversal benchmark of a narrow rectangular channel with two-sided heating may provide additional valuable insights.

CATHARE↗

Implicitly solving phase appearance and disappearance problems using two-fluid six-equation model

Phase appearance and disappearance issue presents serious numerical challenges in two-phase flow simulations using the two-fluid six-equation model. Numerical challenges arise from the singular equation system when one phase is absent, as well as from the discontinuity in the solution space when one phase appears or disappears. In this work, a high-resolution spatial discretization scheme on staggered grids and fully implicit methods were applied for the simulation of two-phase flow problems using the two-fluid six-equation model. A Jacobian-free Newton-Krylov (JFNK) method was used to solve the discretized nonlinear problem. An improved numerical treatment was proposed and proved to be effective to handle the numerical challenges. The treatment scheme is conceptually simple, easy to implement, and does not require explicit truncations on solutions, which is essential to conserve mass and energy. Various types of phase appearance and disappearance problems relevant to thermal-hydraulics analysis have been investigated, including a sedimentation problem, an oscillating manometer problem, a non-condensable gas injection problem, a single-phase flow with heat addition problem and a subcooled flow boiling problem. Successful simulations of these problems demonstrate the capability and robustness of the proposed numerical methods and numerical treatments. As a result, volume fraction of the absent phase can be calculated effectively as zero.

42 ENGINEERING↗

Quantification of Data Needs, Data Collection and

Further to the development of a model analysis framework suitable for calibration and validation of complex multivariate multiphysics models, this report presents an approach to data collection and characterization which can work in parallel with the above-mentioned model analysis framework and support the calibration and validation of the case-study subcooled flow boiling model.

97 MATHEMATICS AND COMPUTING↗

A non-intrusive framework using acoustic signals and deep learning for boiling diagnostics in visual-limited environments

Accurate monitoring of boiling heat transfer is critical for safeguarding high-power systems operating in environments where conventional optical diagnostics are hindered by radiation fields or restricted visual accessibility. This study presents a non-intrusive framework that integrates hydroacoustic sensing with deep learning to infer near-wall boiling characteristics and enable predictive thermal assessment without visual access. In a prototypical subcooled flow-boiling facility representative of the Isotope Production Facility (IPF) at Los Alamos, hydrophones capture boiling-induced acoustic emissions that are transformed into background-removed Short-Time Fourier Transform (STFT) spectrograms. A convolutional neural network (CNN) then regresses heat flux, wall superheat, and key bubble parameters directly from these spectrograms. The CNN achieved predictive accuracy under nominal conditions and demonstrated robustness and generalization under acoustic noise for Signal-to-Noise Ratios (SNRs) down to approximately 0 dB. When integrated into an ANSYS CFX wall-boiling model, the acoustically inferred parameters reproduced boiling curve and critical heat flux (CHF) values consistent with image-based benchmarks. Furthermore, the model retained reliable performance under moderate variations in bulk temperature, flow rate, and hydrophone placement, confirming its generalizability across practical boundary conditions. These results demonstrate the feasibility of hydroacoustic-based deep learning as a viable path toward real-time, radiation-tolerant boiling diagnostics and predictive thermal safety assessment in inaccessible systems such as the IPF.