Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS

The ability to directly measure uranium isotope ratios on environmental swipes has been achieved through a solution-based microextraction process and represents a significant advancement toward the development of a rapid method to analyze international nuclear safeguard samples. Here, a microextraction probe is lowered and sealed onto the swipe surface, and analytes within the sampling site (~8 mm2) are dissolved and extracted into a flowing solvent of 2% nitric acid (HNO 3 ). The mobilized species are subsequently directed into an inductively coupled plasma-mass spectrometer (ICP-MS) for accurate and precise isotope ratio determination. This work highlights the novelty of the sampling mechanism, particularly with the direct coupling of the microextraction probe to the ICP-MS and measurement of uranium isotope ratios. The preliminary method detection limit for the microextraction-ICP-MS method, utilizing a quadrupole-based MS, was determined to be ~50 pg of 238 U. Additionally, precise and accurate isotope ratio measurements were achieved on uranium reference materials for both the major ( 235 U/ 238 U) and minor ( 234 U/ 238 U and 236 U/ 238 U) ratios. While the present work is focused on directly measuring uranium isotopic systems on swipe surfaces for nuclear safeguards and verification applications, the benefits would extend across many applications in which direct solid sampling is sought for elemental and isotopic analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atomic Force Microscopy Thermally-Assisted Microsampling with Atmospheric Pressure Temperature Ramped Thermal Desorption/Ionization-Mass Spectrometry Analysis

The use of atomic force microscopy controlled nano-thermal analysis probes for reproducible spatially resolved thermally-assisted sampling of micrometer-sized areas (ca. 11 m 17 m wide 2.4 m deep) from relatively low number average molecular weight (M n < 3000) polydisperse thin films of poly(2-vinylpyridine) (P2VP) is presented. Following sampling, the nano-thermal analysis probes were moved up from the surface and the probe temperature ramped to liberate the sampled materials into the gas phase for atmospheric pressure chemical ionization and mass spectrometric analysis. Furthermore, the procedure and mechanism for material pickup, the sampling reproducibility and sampling size are discussed and the oligomer distribution information available from slow temperature ramps versus ballistic temperature jumps is presented. For the M n = 970 P2VP, the Mn and polydispersity index determined from the mass spectrometric data were in line with both the label values from the sample supplier and the value calculated from the simple infusion of a solution of polymer into the commercial atmospheric pressure chemical ionization source on this mass spectrometer. With a P2VP sample of higher Mn (M n = 2070 and 2970), intact oligomers were still observed (as high as m/z 2793 corresponding to the 26-mer), but a significant abundance of thermolysis products were also observed. In addition, the capability for confident identification of the individual oligomers by slowly ramping the probe temperature and collecting data dependent tandem mass spectra was also demonstrated. We also discuss the material type limits to the current sampling and analysis approach as well as possible improvements in nano-thermal analysis probe design to enable smaller area sampling and to enable controlled temperature ramps beyond the present upper limit of about 415°C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microextraction-Single Particle-Inductively Coupled Plasma-Mass Spectrometry for the Direct Analysis of Nanoparticles on Surfaces

A novel employment of single particle-inductively coupled plasma-mass spectrometry (SP-ICP-MS) was developed, where a microextraction (ME) probe is used to sample nanoparticles from a surface and analyze them in a single analytical step. The effects of several parameters on the performance of ME-SP-ICP-MS were investigated, including the flow rate, choice of carrier solution, particle size, and the design of the microextraction probe head itself. The optimized ME-SP-ICP-MS technique was used to compare the extraction efficiency (EE, defined as the ratio of particles measured to particles deposited on the surface) of the commercial probe head to a newly designed SP polyether ether ketone (PEEK) probe head. The SP PEEK probe head was found to have increased EE compared to the commercial probe head (8.5 ± 3% vs 3.9 ± 3%, respectively). Increasing the carrier solution flow rate was found to decrease the total analysis time at the cost of decreasing EE. Extraction efficiencies for ME-SP-ICP-MS were typically 4–10%, which is similar to transport efficiencies (1–10%) for conventional SP-ICP-MS. Lastly, ME-SP-ICP-MS was employed for the analysis of nano- and microparticles. The sizes of gold nanoparticles, 30 ± 3 and 51 ± 1.9 nm (certified sizes), and iron-based microparticles, 1000 ± 50 nm (certified size), were accurately determined to be 32.2 ± 2.5, 50.8 ± 3.4, and 1030 ± 57 nm, respectively, by ME-SP-ICP-MS. Further, this work demonstrates the potential of ME-SP-ICP-MS for the direct analysis of particles on common collection surfaces (GSR tabs, carbon planchettes, etc.) while retaining spatial information on particle distribution across the surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-iterative characteristics analysis for high-pressure ramp loading

Here in the canonical ramp compression experiment, a smoothly increasing load is applied to the surface of the sample, and the particle velocity history is measured at two or more different distances into the sample, at interfaces where the surface of the sample can be probed. The velocity histories are used to deduce a stress-density relation, usually using iterative Lagrangian analysis to account for the perturbing effect of the impedance mismatch at the interface. In that technique, a stress-density relation is assumed in order to correct for the perturbation and is adjusted until it becomes consistent with the deduced stress-density relation. This process is subject to the usual difficulties of nonlinear optimization, such as the existence of local minima (sensitivity to the initial guess), possible failure to converge, and relatively large computational effort. We show that, by considering the interaction of successive characteristics reaching a free surface, the stress-density relation can be deduced directly by recursion rather than iteration. This calculation is orders of magnitude faster than iterative analysis and does not require an initial guess. Direct recursion may be less suitable for very noisy data, but it was robust when applied to trial data. The stress-density relation deduced was identical to the result from iterative Lagrangian analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reversible electrochemical modification of the surface of a semiconductor by an atomic-force microscope probe

A technique for reversible surface modification with an atomic-force-microscope (AFM) probe is suggested. In this method, no significant mechanical or topographic changes occur upon a local variation in the surface potential of a sample under the AFM probe. The method allows a controlled relative change in the ohmic resistance of a channel in a Hall bridge within the range 20–25%.

36 MATERIALS SCIENCE↗

Real time drift measurement for colloidal probe atomic force microscope: a visual sensing approach

Drift has long been an issue in atomic force microscope (AFM) systems and limits their ability to make long time period measurements. In this study, a new method is proposed to directly measure and compensate for the drift between AFM cantilevers and sample surfaces in AFM systems. This was achieved by simultaneously measuring z positions for beads at the end of an AFM colloidal probe and on sample surface through an off-focus image processing based visual sensing method. The working principle and system configuration are presented. Experiments were conducted to validate the real time drift measurement and compensation. The implication of the proposed method for regular AFM measurements is discussed. We believe that this technique provides a practical and efficient approach for AFM experiments requiring long time period measurement.

36 MATERIALS SCIENCE↗

Dynamics of spallation during femtosecond laser ablation studied by time-resolved reflectivity with double pump pulses

The dynamics of photomechanical spallation during femtosecond laser ablation of fused silica was studied by time-resolved reflectivity with double pump pulses. Oscillation of reflectivity was caused by interference between the probe pulses reflected at the sample surface and the spallation layer, and was enhanced when the surface was irradiated with the second pump pulse within a time interval, Δτ, of several picoseconds after the first pump pulse. However, as Δτ was increased, the oscillation amplitude decreased with an exponential decay time of 10 ps. The oscillation disappeared when Δτ exceeded 20 ps. This result suggests that the formation time of the spallation layer is approximately 10 ps. A second pump pulse with Δτ shorter than 10 ps excites the bulk sample. The spallation layer that is photo-excited by the first and second pump pulses is separated afterward. In contrast, a pulse with Δτ longer than the formation time excites and breaks up the spallation layer that has already been separated from the bulk. The formation time of the spallation layer, as determined in this experiment, is attributed to the characteristic time of the mechanical equilibration corresponding to the thickness divided by the sound velocity of the photo-excited layer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermoacoustic and thermoreflectance imaging of biased integrated circuits: Voltage and temperature maps

In this work a combined thermoacoustic and thermoreflectance set-up was designed for imaging biased microelectronic circuits. In particular, it was used with polycrystalline silicon resistive tracks grown on a monocrystalline Si substrate mounted on a test chip. Thermoreflectance images, obtained by scanning a probe laser beam on the sample surface, clearly show the regions periodically heated by Joule effect, which are associated to the electric current distribution in the circuit. The thermoacoustic signal, detected by a pyroelectric/piezoelectric sensor beneath the chip, also discloses the Joule contribution of the whole sample. However, additional information emerges when a non-modulated laser beam is focused on the sample surface in a raster scan mode allowing imaging of the sample. The distribution of this supplementary signal is related to the voltage distribution along the circuit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A low energy muon spin rotation and point contact tunneling study of niobium films prepared for superconducting cavities

Point contact tunneling and low energy muon spin rotation are used to probe, on the same samples, the surface superconducting properties of micrometer thick niobium films deposited onto copper substrates using different sputtering techniques: diode, dc magnetron and HIPIMS. The combined results are compared to radio-frequency tests performances of RF cavities made with the same processes. Degraded surface superconducting properties are found to correlate to lower quality factors and stronger Q-slope. In addition, both techniques find evidence for surface paramagnetism on all samples and particularly on Nb films prepared by HIPIMS.

LE-mu SR↗

Tuned oscillator atomic force microscopy methods and apparatus

Techniques for operating an atomic force microscope, the atomic force microscope comprising a cantilever and configured to image a surface of a sample using a probe tip coupled to the cantilever, the techniques comprising using a controller to perform: obtaining, based on at least one intrinsic parameter of the cantilever, a first quality factor and a first free oscillation amplitude, wherein the cantilever exhibits only one stable oscillation state when oscillating at the first free oscillation amplitude and operating at the first quality factor; and controlling the cantilever to exhibit the only one stable oscillation state by controlling the cantilever to oscillate at a fixed frequency at or near a resonance frequency of the cantilever, oscillate at the first free oscillation amplitude, and operate at the first quality factor.

Schwarz, Udo↗

STANDING WAVE PROBES FOR DIMENSIONAL METROLOGY OF LOW DENSITY FOAMS

Typically, parts and geometries of interest to LLNL are made from a combination of complex geometries and a wide array of different materials ranging from metals and ceramics to low density foams and plastic foils. These parts are combined to develop physics experiments for studying material properties, equation of state (EOS) and radiation transport. Understanding the dimensional uncertainty of the parts contained within an experiment is critical to the physical understanding of the phenomena being observed and represents the motivation for developing probe metrology capability that can address LLNL's unique problems. Standing wave probes were developed for measuring high aspect ratio, micrometer scaled features with nanometer resolution. Originally conceived of for the use in the automotive industry for characterizing fuel injector bores and similar geometries, this concept was investigated and improved for use on geometries and materials important to LLNL needs within target fabrication. As part of the original project, detailed understanding of the probe dynamics and interactions with the surface of the sample was investigated. In addition, the upgraded system was utilized for measuring fuel injector bores and micro-lenses as a means of demonstrating capability. This report discusses the use of the standing wave probe for measuring features in low density foams, 55 mg/cc SiO{sub 2} and 982 mg/cc (%6 relative density) copper foam respectively. These two foam materials represent a difficult metrology challenge because of their material properties and surface topography. Traditional non-contact metrology systems such as normal incident interferometry and/or confocal microscopy have difficulty obtaining a signal from the relatively absorptive characteristics of these materials. In addition to the foam samples, a solid copper and plastic (Rexolite{trademark}) sample of similar geometry was measured with the standing wave probe as a reference for both conductive and dielectric materials.

42 ENGINEERING↗

Electroreduction of Zirconia Using Embedded Electrodes

Disc-shaped samples of 8 mol.% Y 2 O 3 -stabilized zirconia (YSZ) with two embedded Pt + YSZ circular electrodes and contacting Pt wires were made by sintering in air at 1500°C. In one sample, four Pt probes were embedded for local electric potential measurements. Porous surface Pt electrodes were applied on the two exposed surfaces. The samples were heated in air over a temperature range from 800°C to 900°C. A DC voltage between 1 V and 1.7 V was applied across the surface electrodes and the embedded electrodes with the positive connected to the surface electrodes. Furthermore, this resulted in the formation of black zirconia between the two embedded electrodes by electrochemical pumping out oxygen. In the sample with embedded Pt probes, the local potential was measured as a function of time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of the interaction conditions of the probe of an atomic-force microscope with the n-GaAs surface on the triboelectrization phenomenon

Triboelectrization as a result of the scanning of an atomic-force-microscope probe over an n-GaAs surface in the contact mode is investigated. The dependences of the local potential variation on the scanning rate and the pressing force of the probe are obtained. The results are explained by point-defect formation in the surface layers of samples under the effect of deformation of these layers during probe scanning. The charge localized at these defects in the case of equilibrium changes the potential of surface, which is subject to triboelectrization. It is shown that, for qualitative explanation of the observed dependences, it is necessary to take into account both the generation and annihilation of defects in the region experiencing deformation.

36 MATERIALS SCIENCE↗

System and method for laser assisted sample transfer to solution for chemical analysis

A system and method for laser desorption of an analyte from a specimen and capturing of the analyte in a suspended solvent to form a testing solution are described. The method can include providing a specimen supported by a desorption region of a specimen stage and desorbing an analyte from a target site of the specimen with a laser beam centered at a radiation wavelength (.lamda.). The desorption region is transparent to the radiation wavelength (.lamda.) and the sampling probe and a laser source emitting the laser beam are on opposite sides of a primary surface of the specimen stage. The system can also be arranged where the laser source and the sampling probe are on the same side of a primary surface of the specimen stage. The testing solution can then be analyzed using an analytical instrument or undergo further processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct measurement of transient electric fields induced by ultrafast pulsed laser irradiation of silicon

We use 30 kV electron pulses to probe transient electric fields above silicon surfaces by pump-probe. Electron beam deflection at 0.29 mm away from the sample surface on the order of 10{sup -2} degrees is measured as a function of time delay and used to measure the local electric fields. The measured field strength and direction change with time; at the pump laser fluence of 67.7 mJ/cm{sup 2}, the maximum field reaches 34 kV/m. We model the transient electric fields based on the propagation of electrons emitted from the Si surface and the percentage of electrons escaping from the surface.

36 MATERIALS SCIENCE↗

Combined Atomic Force Microscope-Based Topographical Imaging and Nanometer Scale Resolved Proximal Probe Thermal Desorption/Electrospray Ionization-Mass Spectrometry

Nanometer scale proximal probe thermal desorption/electrospray ionization mass spectrometry (TD/ESI-MS) was demonstrated for molecular surface sampling of caffeine from a thin film using a 30 nm diameter nano-thermal analysis (nano-TA) probe tip in an atomic force microscope (AFM) coupled via a vapor transfer line and ESI interface to a MS detection platform. Using a probe temperature of 350 C and a spot sampling time of 30 s, conical desorption craters 250 nm in diameter and 100 nm deep were created as shown through subsequent topographical imaging of the surface within the same system. Automated sampling of a 5 x 2 array of spots, with 2 m spacing between spots, and real time selective detection of the desorbed caffeine using tandem mass spectrometry was also demonstrated. Estimated from the crater volume (~2x106 nm3), only about 10 amol (2 fg) of caffeine was liberated from each thermal desorption crater in the thin film. These results illustrate a relatively simple experimental setup and means to acquire in automated fashion sub-micrometer scale spatial sampling resolution and mass spectral detection of materials amenable to TD. The ability to achieve MS-based chemical imaging with 250 nm scale spatial resolution with this system is anticipated.

atomic force microscope↗

Generation and detection of 50 GHz surface acoustic waves by extreme ultraviolet pulses

In this work, we use femtosecond extreme ultraviolet pulses derived from a free electron laser to excite and probe surface acoustic waves (SAWs) on the (001) surface of single crystal SrTiO 3 . SAWs are generated by a pair of 39.9 nm pulses crossed at the sample with the crossing angle defining the SAW wavelength at 84 nm. Detection of SAWs is performed via diffraction of a time-delayed 13.3 nm probe pulse by SAW-induced surface ripples. Despite the low reflectivity of the sample in the extreme ultraviolet range, the reflection mode detection is found to be efficient because of an increase in the diffraction efficiency for shorter wavelengths. We describe a methodology for extracting the SAW attenuation in the presence of a thermal grating, which is based on measuring the decay of oscillations at twice the SAW frequency. The proposed approach can be used to study ultrahigh frequency SAWs in a broad range of materials and will bridge the wave vector gap in surface phonon spectroscopy between Brillouin scattering and He atom scattering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing Systematic Bias in Low-redshift Type Ia Supernova Measurements by Cross Analyzing Surface Brightness and Hubble Residuals

For low-redshift (z < 0.1) SN Ia samples used in several cosmological analyses over the past decade, we probe for systematic bias by looking for correlations between surface brightness (SB) measurements and Hubble residuals (HR). For 292 SNe Ia, we measure SB at the location of the SN Ia from publicly available Pan-STARRS (PS1) images. The Hubble residuals are from two recent measurements with low-z SNe Ia that overlap the PS1 footprint: (1) the DES 3 yr cosmology analysis, with 120 overlapping low-z SNe Ia from the Harvard-Smithsonian Center for Astrophysics surveys and Carnegie Supernova Project, and (2) the PS1 single-telescope analysis, with 172 overlapping low-z SNe Ia from the Foundation Supernova Survey. This study is motivated by previous reports of anomalous inefficiencies and flux scatter for transients on bright galaxies. Here, we compare HR distributions of the bright and faint halves of the SB distribution: the mean HR values differ by ${\rm{\Delta }}\overline{\mathrm{HR}}$ = 0.031 ± 0.018, consistent with no difference at the 2σ level. We also perform a Kolmogorov–Smirnov (KS) test for the bright and faint half HR distributions, and conclude that the two distributions are statistically consistent with a KS p-value of 0.07. However, if future studies with larger data sets find ${\rm{\Delta }}\overline{\mathrm{HR}}\sim 0.03$ with high significance, this difference would be a leading systematic uncertainty in measurements of the dark energy equation of state, w.

79 ASTRONOMY AND ASTROPHYSICS↗