Search NASA⌕ Search

SEARCH · Search NASA

Results for “Syringes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

High density cell culture system

An annular culture vessel for growing mammalian cells is constructed in a one piece integral and annular configuration with an open end which is closed by an endcap. The culture vessel is rotatable about a horizontal axis by use of conventional roller systems commonly used in culture laboratories. The end wall of the endcap has tapered access ports to frictionally and sealingly receive the ends of hypodermic syringes. The syringes permit the introduction of fresh nutrient and withdrawal of spent nutrients. The walls are made of conventional polymeric cell culture material and are subjected to neutron bombardment to form minute gas permeable perforations in the walls.

Spaulding, Glenn F.↗

Constructing a High Density Cell Culture System

An annular culture vessel for growing mammalian cells is constructed in a one piece integral and annular configuration with an open end which is closed by an endcap. The culture vessel is rotatable about a horizontal axis by use of conventional roller systems commonly used in culture laboratories. The end wall of the endcap has tapered access ports to frictionally and sealingly receive the ends of hypodermic syringes. The syringes permit the introduction of fresh nutrient and withdrawal of spent nutrients. The walls are made of conventional polymeric cell culture material and are subjected to neutron bombardment to form minute gas permeable perforations in the walls.

Spaulding, Glenn F.↗

Liquid Metering Centrifuge Sticks (LMCS): A Centrifugal Approach to Metering Known Sample Volumes for Colorimetric Solid Phase Extraction (C-SPE)

Phase separation is one of the most significant obstacles encountered during the development of analytical methods for water quality monitoring in spacecraft environments. Removing air bubbles from water samples prior to analysis is a routine task on earth; however, in the absence of gravity, this routine task becomes extremely difficult. This paper details the development and initial ground testing of liquid metering centrifuge sticks (LMCS), devices designed to collect and meter a known volume of bubble-free water in microgravity. The LMCS uses centrifugal force to eliminate entrapped air and reproducibly meter liquid sample volumes for analysis with Colorimetric Solid Phase Extraction (C-SPE). C-SPE is a sorption-spectrophotometric platform that is being developed as a potential spacecraft water quality monitoring system. C-SPE utilizes solid phase extraction membranes impregnated with analyte-specific colorimetric reagents to concentrate and complex target analytes in spacecraft water samples. The mass of analyte extracted from the water sample is determined using diffuse reflectance (DR) data collected from the membrane surface and an analyte-specific calibration curve. The analyte concentration can then be calculated from the mass of extracted analyte and the volume of the sample analyzed. Previous flight experiments conducted in microgravity conditions aboard the NASA KC-135 aircraft demonstrated that the inability to collect and meter a known volume of water using a syringe was a limiting factor in the accuracy of C-SPE measurements. Herein, results obtained from ground based C-SPE experiments using ionic silver as a test analyte and either the LMCS or syringes for sample metering are compared to evaluate the performance of the LMCS. These results indicate very good agreement between the two sample metering methods and clearly illustrate the potential of utilizing centrifugal forces to achieve phase separation and metering of water samples in microgravity.

Gazda, Daniel B.↗

Development of an Inline Urine Monitoring System for the International Space Station

Human exposure to microgravity during spaceflight causes bone loss. Calcium and other metabolic byproducts are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is essential to determining crew bone loss and the effectiveness of countermeasures. Previous US Space Shuttle (SS) Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to cross contamination between users and fluid system instabilities. Currently, urine voids must be collected manually in a flexible plastic bag containing a known tracer quantity. The crew member must completely mix the bag then withdraw a representative syringe sample for later ground analysis. The current bag system accuracy is highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures the void volume, and allows for syringe sampling. After operations, the ISS UMS delivers the urine to the WHC for normal processing then flushes its plumbing with a small water volume. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, greatly reduces cross contamination between urine voids (< 0.5 ml urine), and provides accurate volume measurements (< +/- 2% error for 100 to 1000 ml void volumes). The system performance has been validated with extensive ground tests and reduced gravity aircraft flights. The lockersized ISS UMS is currently being modified to interface with the ISS Node 3 WHC Russian ACY hardware. The operation principles, characteristics, and results are outlined in the paper.

Broyan, James Lee, Jr.↗

Development of an In-line Urine Monitoring System for the International Space Station

Exposure to microgravity during space flight causes bone loss when calcium and other metabolic by-products are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is thus essential in determining crew bone loss and the effectiveness of the countermeasures that are taken to minimize this loss. Earlier space shuttle Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to the cross-contamination that took place between users, as well as to fluid system instabilities. Crew urine voids are currently collected manually in a flexible plastic bag that contains a known tracer quantity. A crew member must completely mix the contents of this bag before withdrawing a representative syringe sample for later ground analysis. The existing bag system accuracy is therefore highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures void volume, and allows for syringe sampling. After the ISS UMS has been used by a crew member, it delivers urine to the WHC for normal processing. The UMS plumbing is then flushed with a small volume of water. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, consequently greatly reducing cross-contamination among urine voids (less than 0.5 mL urine) while also providing accurate volume measurements (less than 2 percent error for 100 to 1,000 mL void volumes). ISS UMS performance has been validated through extensive ground tests and reduced-gravity aircraft flights. The locker-sized ISS UMS is currently undergoing a design modification that will permit it to interface with the ISS Node 3 WHC Russian toilet (ACY) hardware. The operating principles, characteristics, and results of this design modification are outlined here.

Broyan, James Lee, Jr.↗

Effectiveness of Needleless Vial Adaptors and Blunt Cannulas for Drug Administration in a Microgravity Environment

Fluid Isolation in the medication vial: Air/ fluid isolation maneuvers were used to move the medication to the septum end of vial. This isolation may be achieved in multiple ways based on the experience of the astronaut with fluid management in microgravity. If vial adaptors/blunt cannula or syringe assembly is inserted into the to vial before fluid isolation commences, the stability of this assembly should be considered in an effort to limit the risk of "slinging off" of the vial during isolation. Alternatively, fluid isolation can be performed prior to attaching the syringe/vial adaptor assembly. Terrestrial practices for medication withdrawal from a nonvented vial require injection of an equivalent amount of air as the expected medication volume prior to withdrawing liquid. In microgravity, this action is still valid, however the injection of additional air into the vial creates a multitude of micro bubbles and increases the volume of medication mixed with air that then must be withdrawn to achieve the desired drug volume in syringe. This practice is more likely to be required when using vials >30ml in size and injection volumes >10mL. It is felt that based on the microgravity flight, the practice of air injection is more of a hindrance than help.

Hailey, M.↗

Bioreactors Drive Advances in Tissue Engineering

It was an unlikely moment for inspiration. Engineers David Wolf and Ray Schwarz stopped by their lab around midday. Wolf, of Johnson Space Center, and Schwarz, with NASA contractor Krug Life Sciences (now Wyle Laboratories Inc.), were part of a team tasked with developing a unique technology with the potential to enhance medical research. But that wasn t the focus at the moment: The pair was rounding up colleagues interested in grabbing some lunch. One of the lab s other Krug engineers, Tinh Trinh, was doing something that made Wolf forget about food. Trinh was toying with an electric drill. He had stuck the barrel of a syringe on the bit; it spun with a high-pitched whirr when he squeezed the drill s trigger. At the time, a multidisciplinary team of engineers and biologists including Wolf, Schwarz, Trinh, and project manager Charles D. Anderson, who formerly led the recovery of the Apollo capsules after splashdown and now worked for Krug was pursuing the development of a technology called a bioreactor, a cylindrical device used to culture human cells. The team s immediate goal was to grow human kidney cells to produce erythropoietin, a hormone that regulates red blood cell production and can be used to treat anemia. But there was a major barrier to the technology s success: Moving the liquid growth media to keep it from stagnating resulted in turbulent conditions that damaged the delicate cells, causing them to quickly die. The team was looking forward to testing the bioreactor in space, hoping the device would perform more effectively in microgravity. But on January 28, 1986, the Space Shuttle Challenger broke apart shortly after launch, killing its seven crewmembers. The subsequent grounding of the shuttle fleet had left researchers with no access to space, and thus no way to study the effects of microgravity on human cells. As Wolf looked from Trinh s syringe-capped drill to where the bioreactor sat on a workbench, he suddenly saw a possible solution to both problems. It dawned on me that rotating the wall of the reactor would solve one of our fundamental fluid mechanical problems, specifically by removing the velocity gradient of the tissue culture fluid media near the reactor s walls, says Wolf. It looked as though it would allow us to suspend the growing cells within the reactor without introducing turbulent fluid mechanical conditions.

Source record↗

Electrospraying for Precision Delivery of Water and Nutrients for Aeroponics in Microgravity

Developed an enclosure with a custom high voltage nozzle that electrosprays wire "roots" with milliliters (mL) of water in real time by measuring the charge sprayed onto the roots. It uses the spray’s charge to mass from previous measurements with the same nozzle (and the density of water) to convert the display to volume. To deliver water to the nozzle consistently and programmatically, the syringe pump performed the best for experiments because the diaphragm pump created a stuttered flow and the pressurized reservoir’s pressure controller was more complex than the syringe pump’s commercial LabVIEW software that direct controls flow rate.

Joel D Malissa↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

Reverse martensitic transformation on the corrosion behavior of a 2304 lean duplex stainless steel

This study investigates the influence of the reverse martensitic transformation on the corrosion behavior of 2304 lean duplex stainless steel (LDSS) at low temperatures (400–600°C). The steel underwent cold rolling, followed by isochronal annealing for 0.5 h. Phase transformations and microstructures were analyzed using X-ray diffraction, scanning electron microscopy, and transmission electron microscopy. Corrosion resistance was evaluated using a syringe cell with cyclic potentiodynamic polarization in 0.6 M NaCl solution and double-loop electrochemical potentiokinetic reactivation in 0.5 M H 2 SO 4 + 0.001 M KSCN solution. A bimodal breakdown potential behavior, associated with either pitting or transpassivity, was observed in the as-received (AR) and samples annealed at 400°C. Pitting in the AR sample was associated with Al–Mg–Si–Ca–O inclusions, while pitting on the samples annealed at 400°C was linked to local reduced passive film resistance. Severe cold rolling enhanced the pitting resistance of 2304 LDSS. Selective electrochemical etching revealed preferential corrosion at phase interfaces and within the austenite phase. Additionally, annealing at 500°C to 600°C led to a marked decrease in pitting resistance and increased sensitization. Electron backscatter diffraction analysis of the corroded pits in the annealed specimens indicated that pits tend to nucleate and grow in α'-martensite/austenite regions. Furthermore, the nanostructure formed during low-temperature reversion, characterized by dislocation-cell martensite with high dislocation density and stacking faults, may adversely affect corrosion resistance due to heterogeneities associated with alloying element redistribution.

36 MATERIALS SCIENCE↗

Manufacturing of Continuous Core–Shell Hydrated Salt Fibers for Room Temperature Thermal Energy Storage

The encapsulation of salt hydrate phase change materials (PCMs) in uniform microscale bodies has yet been reported in research due in part to the delicate relationship between thermal performance and water-to-salt ratios which are easily altered during manufacturing. Herein, core–shell composite fibers comprised of a salt hydrate PCM core and a poly(acrylonitrile) (PAN) shell are wet spun in a continuous process using a syringe pump and coaxial die. The PCM phase comprises calcium chloride hexahydrate (CaCl 2 ·6H 2 O) with strontium chloride hexahydrate(SrCl 2 ·6H 2 O) (3 wt%) and fumed silica(SiO 2 ) (2 wt%) as additive, a composition that is prepared from homogenous melt at 40 °C. 15 wt% PAN in dimethylsulfoxide solvent is used to prepare the shell-forming polymer gel. PCM and polymer gel injection rates of 10–40 mL h –1 are used to spin coaxial fibers through a coagulation bath, yielding continuous microtubules with diameters in the range of 850–1500 μm. Cyclic testing shows that after 1000 cycles, melting enthalpies incurred only a 3.5% decline from 131.46 to 126.9 J g –1 . In conclusion, success here overcomes several coincidental drawbacks of PCM fiber performance and manufacturing and delivers the first example of scalable roll-to-roll PCM fiber produced by wet spinning for building material applications.

36 MATERIALS SCIENCE↗

The Relationship Between Gelatin Sponge Preparation Methods and the Incidence of Intrauterine Synechia Following Uterine Artery Embolization for Postpartum Hemorrhage

Purpose: To evaluate the relationship between gelatin sponge preparation methods and the incidence of intrauterine synechia following uterine artery embolization (UAE) for postpartum hemorrhage (PPH). Materials and Methods: In a retrospective monocentric study, we used data from 20 consecutive UAE procedures (19 patients) for PPH, performed in 2007–2016, in which gelatin sponge had been used. The gelatin sponge was processed either into a slurry by pumping it back and forth about 10 times through two syringes connected to a three-way stopcock or into pledgets using a scalpel and small scissors to obtain pieces approximately 2 × 2 × 2 mm in size. Patient information was obtained from medical records, and the data were compared between patients treated with the slurry (n = 7) or pledgets (n = 13) forms. Due to the lack of follow-up data and hysterectomy after UAE, the sample size was 6 and 12 because 1 patient with 2 procedures was excluded. Results: The rate of intrauterine synechia was significantly higher in the slurry group (5/6, 83.3%) than that in the pledgets group (0/12, 0%; P < 0.001). In contrast, there were no significant differences in population characteristics, such as the incidence of placenta accreta, non-placental diseases, and severity of shock (DIC score, shock index, or blood loss) between the groups. Conclusions: Although non-randomization and small sample size were the two main limitations, our observations suggest that UAE using gelatin sponge slurry may be associated with a high incidence of intrauterine synechia compared to UAE using pledgets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Kinetic modeling of anaerobic degradation of plant-derived aromatic mixtures by Rhodopseudomonas palustris

Abstract Rhodopseudomonas palustris is a model microorganism for studying the anaerobic metabolism of aromatic compounds. While it is well documented which aromatics can serve as sole organic carbon sources, co-metabolism of other aromatics is poorly understood. This study used kinetic modeling to analyze the simultaneous degradation of aromatic compounds present in corn stover hydrolysates and model the co-metabolism of aromatics not known to support growth of R. palustris as sole organic substrates. The simulation predicted that p -coumaroyl amide and feruloyl amide were hydrolyzed to p -coumaric acid and ferulic acid, respectively, and further transformed via p -coumaroyl-CoA and feruloyl-CoA. The modeling also suggested that metabolism of p -hydroxyphenyl aromatics was slowed by substrate inhibition, whereas the transformation of guaiacyl aromatics was inhibited by their p -hydroxyphenyl counterparts. It also predicted that substrate channeling may occur during degradation of p -coumaroyl-CoA and feruloyl-CoA, resulting in no detectable accumulation of p -hydroxybenzaldehyde and vanillin, during the transformation of these CoA ligated compounds to p- hydroxybenzoic acid and vanillic acid, respectively. While the simulation correctly represented the known transformation of p -hydroxybenzoic acid via the benzoyl-CoA pathway, it also suggested co-metabolism of vanillic acid and syringic acid, which are known not to serve as photoheterotrophic growth substrate for R. palustris .

59 BASIC BIOLOGICAL SCIENCES↗

Trends in Light and Temperature Sensitivity Recommendations among Licensed Biotechnology Drug Products

Inherent structural and functional properties of biotechnology-derived therapeutic biologics make them susceptible to light- and temperature-induced degradation and consequently can influence their quality. Photosensitivity of therapeutic proteins continues to be examined, but the commonalities and trends of storage conditions and information about light and temperature sensitivity among currently licensed therapeutic proteins has not been previously surveyed. Using a comprehensive and relational database approach, we conducted a scientific survey of all licensed biotechnology-derived drug products with the goal of providing evidence-based information about recommended storage conditions of formulations sorted by light- and temperature-related attributes as described for each product at licensure. We report the prevalence of indications for light and temperature sensitivity in formulations categorized by their presentation type, number of doses, container type, dosage form and active molecule type. We also report the storage temperature range across formulations and diluents for reconstitution and dilution. Formulations with excipients that potentially facilitate light-induced and thermal degradation were also noted. The result of our analysis indicates that light and temperature sensitivity are prevalent across therapeutic protein formulations. However, when a formulation is reconstituted or diluted, both light and temperature sensitivity are less clear. In addition, light and temperature sensitivity are more well defined in liquid formulations than lyophilized powder formulations, and more well defined in products manufactured in autoinjectors, prefilled-syringes, and pens than products in vials. Overall, our report provides a data-driven summary of storage conditions among therapeutic protein formulations to support the development of future biologic drug products.

60 APPLIED LIFE SCIENCES↗

Processes and electron flow in a microbial electrolysis cell bioanode fed with furanic and phenolic compounds

We report that furanic and phenolic compounds are problematic compounds resulting from the pretreatment of lignocellulosic biomass for biofuel production. Microbial electrolysis cell (MEC) is a promising technology to convert furanic and phenolic compounds to renewable H 2 . The objective of the research presented here was to elucidate the processes and electron equivalents flow during the conversion of two furanic (furfural, FF; 5-hydroxymethyl furfural, HMF) and three phenolic (syringic acid, SA; vanillic acid, VA; 4-hydroxybenzoic acid, HBA) compounds in the MEC bioanode. Cyclic voltammograms of the bioanode demonstrated that purely electrochemical reactions in the biofilm attached to the electrode were negligible. Instead, microbial reactions related to the biotransformation of the five parent compounds (i.e., fermentation followed by exoelectrogenesis) were the primary processes resulting in the electron equivalents flow in the MEC bioanode. A mass-based framework of substrate utilization and electron flow was developed to quantify the distribution of the electron equivalents among the bioanode processes, including biomass growth for each of the five parent compounds. Using input parameters of anode efficiency and biomass observed yield coefficients, it was estimated that more than 50% of the SA, FF, and HMF electron equivalents were converted to current. In contrast, only 12 and 9% of VA and HBA electron equivalents, respectively, resulted in current production, while 76 and 79% remained as fermentation end products not further utilized in exoelectrogenesis. For all five compounds, it was estimated that 10% of the initially added electron equivalents were used for fermentative biomass synthesis, while 2 to 13% were used for exoelectrogenic biomass synthesis. Finally, the proposed mass-based framework provides a foundation for the simulation of bioanode processes to guide the optimization of MECs converting biomass-derived waste streams to renewable H 2 .

09 BIOMASS FUELS↗

Methodology to determine printability criteria of highly concentrated pastes through rheological characterization

Material extrusion is an additive manufacturing technique that enables the creation of reproducible and complex hardware by depositing a viscous, shear-thinning ink onto a substrate in a custom-pattern via extrusion through a syringe. Here, the ability of an ink to be extruded onto a substrate in many layers, and maintain the desired shape is what defines the printability. Printability is often investigated by formulating, printing, and postmortem analysis of final parts in an iterative manner. Investigations of printability through rheological characterization have often been concerned with inks that straddle the line between printable and too thin, leaving out an entire class of inks that are highly-filled pastes, where extrudability is the limiting factor. Highly-filled pastes continue to pose issues for researchers as the effect of filler morphology, size, loading, and packing fraction on the ink rheology and corresponding printability is not understood. While traditional rheological characterizations may be useful for some inks, we show that protocols utilizing steady-shear, or large-amplitude oscillatory shear are difficult and unreliable for highly-filled pastes. Through transient rheology paired with real-time images we show that each traditional protocol produces inhomogeneous deformations that violate the assumptions that underly common rheological definitions. Instead, we demonstrate metrics measured with small-amplitude oscillatory shear that are correlated to the printability of various ink formulations ranging in loading. The rheological measures that accurately predict the printability of the inks are the axial stress measured at small amplitudes, and the critical stress amplitude above which rheological characterizations become impossible. In addition, we estimate the maximum packing fraction for each filler, based on the exponent common to hard sphere models, and show that the printability of each ink can be predicted by the ratio of the packing fraction to the theoretical maximum. We show how small-amplitude oscillatory shear allows users to develop printability criteria for any ink to enhance the workflow in the development of new inks, increase the performance of material extrusion printing, and improve the stability of printed parts, with less wasted time and materials.

36 MATERIALS SCIENCE↗

CaloriSMART: Small-scale test-stand for rapid evaluation of active magnetic regenerator performance

We report operation of a device designed specifically for rapid experimental evaluation of performance of magnetocaloric materials in different magnetic fields using a compact active magnetic regenerator bed with a total volume of approximately 5 mL. Other features of the system include digital control of the rotating-permanent-magnet field source and custom dual-opposed syringe pump that enable precise tuning and coupling of the flow profile and the magnetic field profile. Performance of the device is demonstrated for flow volumes between 1 and 4 mL (utilization from 0.48 to 1.9), maximum magnetic fields of 1.13 and 1.45 T, and applied cooling powers from 0 to 20 W at frequencies from 0.5 to 4 Hz. A regenerator comprised of 25 g of 200 µm spherical Gd powder reached temperature spans of 19.3 K under no applied cooling load and 2.6 K under the maximum applied cooling load of 20 W. The device also achieves a very high specific exergetic cooling power of 73 W L -1 T -1 . Results obtained at two different maximum magnetic fields in the same device suggest a powerful new scaling for regenerator performance: the exergetic power quotient. The exergetic power quotient shows a simple scaling of device cooling performance with the amount of active material and the magnetic field strength. This suggests results from a small device correlate to expected performance of a larger regenerator, making the exergetic power quotient a well-suited parameter for evaluating functionality of active magnetic regenerators employing new magnetocaloric materials.

47 OTHER INSTRUMENTATION↗