Search NASA⌕ Search

SEARCH · Search NASA

Results for “TEST CHAMBER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station, the Crew and Thermal Systems Division at NASA JSC was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms in a simulated space environment versus testing with a full suit. The Dual Glove Box (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 10^-5 Torr with roughing and cryogenic pumps, and a wide range of shroud temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater plates. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through the development of 2 temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Extravehicular Activity (EVA) suits↗

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station (ISS), the Crew and Thermal Systems Division (CTSD) at NASA Johnson Space Center (JSC) was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms and gloves in a simulated space environment versus testing with a full suit. The Dual Glovebox (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 5x10-4 Torr (0.066 Pa) with roughing and cryogenic pumps, and a wide range of temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater cables. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through two temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

spacesuit arms↗

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station (ISS), the Crew and Thermal Systems Division (CTSD) at NASA Johnson Space Center (JSC) was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms and gloves in a simulated space environment versus testing with a full suit. The Dual Glovebox (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 5x10-4 Torr (0.066 Pa) with roughing and cryogenic pumps, and a wide range of temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater cables. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through two temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Extravehicular Activity (EVA)↗

Dual Glovebox Thermal Vacuum Chamber: Testing Capabilities for Spacesuit Arms and Gloves

The development of Extravehicular Activity (EVA) suits and hand mobility EVA tasks are complex, high risk, and difficult to test in a simulated space environment. During the early assembly of the International Space Station (ISS), the Crew and Thermal Systems Division (CTSD) at NASA Johnson Space Center (JSC) was tasked to design a chamber that could use two Extravehicular Mobility Unit (EMU) arms and gloves in a simulated space environment versus testing with a full suit. The Dual Glovebox (DGB) Chamber was built and served to help develop EVA tools and operations to assist with Return to Flight for the Space Shuttle after the Columbia accident. With the recent development of the Exploration Extravehicular Mobility Unit (xEMU) and new commercial suits through the Extravehicular Activities Services (xEVAS) contract, the DGB can support the need to do suit component testing at thermal extremes and EVA operations without the cost of full suit testing. The DGB can simulate realistic delta pressures, vacuum down to 5x10-4 Torr (0.066 Pa) with roughing and cryogenic pumps, and a wide range of temperatures achieved via a combination of Liquid Nitrogen (LN2), conditioned Gaseous Nitrogen (GN2), Infrared (IR) lamps, and heater cables. Recent developmental work has verified operational status of the chamber and expanded the capabilities of the DGB to include thermal contact testing of suit gloves through two temperature-controlled grab bars. This paper will discuss the history and capabilities of the DGB, and the chamber’s future role in the development of new spacesuit systems.

Extravehicular Activity (EVA)↗

Secondary Electron Yield and Groove Chamber Tests in PEP-II

Possible remedies for the electron cloud in positron damping ring (DR) of the International Linear Collider (ILC) includes thin-film coatings, surface conditioning, photon antechamber, clearing electrodes and chamber with grooves or slots [1]. We installed chambers in the PEP-II Low Energy Ring (LER) to monitor the secondary electron yield (SEY) of TiN, TiZrV (NEG) and technical accelerator materials under the effect of electron and photon conditioning in situ. We have also installed chambers with rectangular grooves in straight sections to test this possible mitigation technique. In this paper, we describe the ILC R&D ongoing effort at SLAC to reduce the electron cloud effect in the damping ring, the chambers installation in the PEP-II and latest results.

43 PARTICLE ACCELERATORS↗

Secondary Electron Yield Measurements and Groove Chambers Tests in the PEP-II Beam Line Straights Sections

Beam instability caused by the electron cloud has been observed in positron and proton storage rings and it is expected to be a limiting factor in the performance of the positron Damping Ring (DR) of future Linear Colliders such as ILC and CLIC [1, 2]. In the Positron Low Energy Ring (LER) of the PEP-II accelerator, we have installed vacuum chambers with rectangular grooves in a straight magnetic-free section to test this promising possible electron cloud mitigation technique. We have also installed a special chamber to monitor the secondary electron yield of TiN and TiZrV (NEG) coating, Copper, Stainless Steel and Aluminum under the effect of electron and photon conditioning in situ in the beam line. In this paper, we describe the ongoing R&D effort to mitigate the electron cloud effect for the ILC damping ring, the latest results on in situ secondary electron yield conditioning and recent update on the groove tests in PEP-II.

36 MATERIALS SCIENCE↗

Venus Surface Environmental Chamber Test of SiC JFET-R Multi-Chip Circuit Board

This poster describes a first attempt to demonstrate a multi-chip prototype lander control and sensor signal digitization electronics circuit board comprised of ten NASA Glenn IC Generation 11 SiC JFET-R IC chips in 460 °C, 9.4 MPa harsh Venus surface conditions. The lander circuit ceased electrical operation prematurely at 107 °C as the Venus chamber heated up. Optical and SEM post-test inspections indicate fatal dielectric cracks occurred on only one of the ten SiC chips.

silicon carbide↗

A feasibility test of the laser velocimeter in the Mach 5 nozzle test chamber

A one-component, fringe type laser velocimeter in the backscatter mode was used to measure flow velocities from 732 to 792 m/sec about a shock from an inclined flat plate in a Mach 5 tunnel. This test was chosen to determine system characteristics in applying the laser velocimeter to measure velocities in hypersonic flow fields. The seeding particles, less than 20 microns in diameter, were injected into the tunnel supply pipe, approximately 1 meter upstream of the nozzle throat, through a rake along the diameter. The LV signals were processed by two methods, a scanning spectrum analyzer and a high-speed counter. The measured velocity distributions obtained were analyzed to determine the errors due to particle lag, transit time broadening and high-speed counter quantizing error.

Meyers, J. F.↗

Habitability Assessments And Lessons-learned From 3-day And 11-day Enriched Oxygen Hypobaric Chamber Tests At NASA Johnson Space Center

INTRODUCTION: Decompression sickness (DCS) is a risk to the health and performance of astronauts and high-altitude aircrew. Tolerance to flammability, hypoxia, prebreathe duration, and DCS risk varies across different organizations, vehicles, suits, and destinations, necessitating a variety of DCS risk mitigation approaches. Existing models of altitude DCS risk are often insufficient to enable accurate risk-informed decisions during hardware development, mission planning, and flight operations. METHODS: NASA completed outfitting of a dedicated facility at Johnson Space Center to support testing of up to eight human subjects for multiple days in hypobaric and enriched oxygen atmospheres. The primary purpose of the testing capability is validation of DCS risk mitigation protocols for Artemis missions to the Moon; however, it will also support development and validation of a generalizable altitude DCS risk estimation tool. A 3-day and an 11-day prebreathe validation test were completed in 2022, each with 8 human subjects living at 56.5 kPa (8.2 psia), 34% O2, 66% N2, with 5 simulated EVAs performed on masks at 29.6 kPa (4.3 psi), 85% O2, 15% N2. Facility and organizational lessons-learned and process improvements were recorded during and following the tests, and subjective habitability ratings were recorded daily during the 11-day test. Hypoxia and DCS-related physiological and cognitive outcome measures were recorded during both tests and are reported in companion presentations. RESULTS & DISCUSSION: All subjects completed each of the tests. Primary habitability issues related to mask discomfort during simulated EVAs and poor sleep quality due to thin mattresses. Polybenzimidazole (PBI) clothing was worn by all subjects due to the increased fire risk and may be required for Artemis missions; clothing was found to be acceptable overall with the worst ratings being due to poor fit and inelasticity. Chamber O2 and CO2 sensor inconsistency was observed that did not result in test termination but required post-test follow-up. Forward plans include additional hypobaric testing and integration of existing and future physiological outcome data into an open-source Aerospace Estimation Tool for Hypobaric Exposure Risk (AETHER). NASA is also working to make the testing capability available to commercial companies.

Andrew F J Abercromby↗

Habitability Assessments And Lessons-learned From 3-day And 11-day Enriched Oxygen Hypobaric Chamber Tests At NASA Johnson Space Center

INTRODUCTION: Decompression sickness (DCS) is a risk to the health and performance of astronauts and high-altitude aircrew. Tolerance to flammability, hypoxia, prebreathe duration, and DCS risk varies across different organizations, vehicles, suits, and destinations, necessitating a variety of DCS risk mitigation approaches. Existing models of altitude DCS risk are often insufficient to enable accurate risk-informed decisions during hardware development, mission planning, and flight operations. METHODS: NASA completed outfitting of a dedicated facility at Johnson Space Center to support testing of up to eight human subjects for multiple days in hypobaric and enriched oxygen atmospheres. The primary purpose of the testing capability is validation of DCS risk mitigation protocols for Artemis missions to the Moon; however, it will also support development and validation of a generalizable altitude DCS risk estimation tool. A 3-day and an 11-day prebreathe validation test were completed in 2022, each with 8 human subjects living at 56.5 kPa (8.2 psia), 34% O2, 66% N2, with 5 simulated EVAs performed on masks at 29.6 kPa (4.3 psi), 85% O2, 15% N2. Facility and organizational lessons-learned and process improvements were recorded during and following the tests, and subjective habitability ratings were recorded daily during the 11-day test. Hypoxia and DCS-related physiological and cognitive outcome measures were recorded during both tests and are reported in companion presentations. RESULTS & DISCUSSION: All subjects completed each of the tests. Primary habitability issues related to mask discomfort during simulated EVAs and poor sleep quality due to thin mattresses. Polybenzimidazole (PBI) clothing was worn by all subjects due to the increased fire risk and may be required for Artemis missions; clothing was found to be acceptable overall with the worst ratings being due to poor fit and inelasticity. Chamber O2 and CO2 sensor inconsistency was observed that did not result in test termination but required post-test follow-up. Forward plans include additional hypobaric testing and integration of existing and future physiological outcome data into an open-source Aerospace Estimation Tool for Hypobaric Exposure Risk (AETHER). NASA is also working to make the testing capability available to commercial companies.

Andrew Abercromby↗

Bench Scale Heat Pipe and Vapor Chamber Testing for Space Applications

NASA’s space missions demand better and more efficient carbon dioxide removal systems. wo challenges present themselves in improving the state of the art pellet adsorption beds: power minimization and uniform heating for carbon dioxide desorption. Titanium heat pipes and vapor chambers were found to be excellent candidates in solving these problems because of their passive heating nature, tolerance to high temperatures, and capability of direct implementation into these adsorbent beds.This research work compares these different titanium heat pipes (HPs) and vapor chambers (VPs).

MultiSORB↗

Analysis of Anechoic Chamber Testing of the Hurricane Imaging Radiometer

The Hurricane Imaging Radiometer System (HIRAD) is a new airborne passive microwave remote sensor developed to observe hurricanes. HIRAD incorporates synthetic thinned array radiometry technology, which use Fourier synthesis to reconstruct images from an array of correlated antenna elements. The HIRAD system response to a point emitter has been measured in an anechoic chamber. With this data, a Fourier inversion image reconstruction algorithm has been developed. Performance analysis of the apparatus is presented, along with an overview of the image reconstruction algorithm

Fenigstein, David↗

Altitude-Test-Chamber Investigation of the Endurance and Performance Characteristics of the J65-W-7 Engine at a Mach Number of 2.0

An investigation of the endurance characteristics, at high Mach number, of the J65-W-7 engine was made in an altitude chamber at the Lewis laboratory. The investigation was made to determine whether this engine can be operated at flight conditions of Mach 2 at 35,000-feet altitude (inlet temperature, 250 F) as a limited-service-life engine Failure of the seventh-stage aluminum compressor blades occurred in both engines tested and was attributed to insufficient strength of the blade fastenings at the elevated temperatures. For the conditions of these tests, the results showed that it is reasonable to expect 10 to 15 minutes of satisfactory engine operation before failure. The high temperatures and pressures imposed upon the compressor housing caused no permanent deformation. In general, the performance of the engines tested was only slightly affected by the high ram conditions of this investigation. There was no discernible depreciation of performance with time prior to failure.

Biermann, A.E.↗

Permanent Foam Fixatives for Radioactive Contamination Control: Environmental Chamber Testing

The Department of Energy (DOE) Office of Environmental Management (EM) is tasked with closing cleanup sites throughout the DOE-EM complex. A major component of successfully closing the sites is the deactivation and decommissioning (D&D) of radioactively contaminated buildings in nuclear facilities. Deactivation consists of the process of placing a contaminated facility in stable condition in order to minimize any risks that could affect workers, the public, and the environment. Successful deactivation and decommissioning consists of leaving the buildings in an agreed upon end state to provide future protection against hazards. Hazards include radiation but can also include asbestos, polychlorinated biphenyls, and other environmental and physical hazards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Environmental Chamber Testing and Headspace Evaluation of a Commercial-Off-The-Shelf Foam Fixative to Support Deactivation and Decommissioning Activities

The Department of Energy (DOE) Office of Environmental Management (EM) is tasked with identifying high priority technical needs and the Technology Development (TD) tasks required to meet those needs in support of ongoing deactivation and decommissioning (D&D) of Department of Energy infrastructure across the United States. This work consists of placing a radioactively contaminated facility in stable condition to minimize any risks that could affect workers, the public, and the environment. Successful deactivation and decommissioning will leave the buildings in an agreed upon end state to provide future protection against a wide range of hazards that include radiation, asbestos, polychlorinated biphenyls, and other environmental and public health risks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An instrument for real time detection of contamination in space environmental tests chambers

An instrument for in situ vacuum detection of surface reflectance changes at 1216A was designed. Using successive reflections, this instrument is more sensitive as an indicator of reflectance changes than similar instruments having only a single reflection. The selection of each component of the instrument and its operational performance is discussed.

Richmond, R. G.↗

Flame-Test Chamber

Experimental chamber provides controlled environment for observation and measurement of flames propagating in expanding plume of flammable air/fuel mixture under atmospheric conditions. Designed to evaluate quenching capability of screen-type flame arresters in atmospheric vents of fuel cargo tanks aboard marine cargo vessels.

Bjorklund, R. A.↗