Captive-fired Testing of Solid Rocket Motors - Space Vehicle Design Criteria /chemical Propulsion/
Captive-fired testing of solid rocket motors for design criteria
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Captive-fired testing of solid rocket motors for design criteria
A series of field experiments involving JP-4 fires of 7.6m dia and 15.2m dia was conducted under the sponsorship of NASA. The temperature inside the fire, the specie composition and vertical axial velocity were measured at several height locations and radial positions. The peak temperature recorded is 1400-1500 K; the velocities at 6m height are 11-12 m/s. The oxygen-to-nitrogen mass ratio along the vertical axis was found to be nearly a constant at 0.05. Significant necking of the fire was observed. A simple theoretical model was developed that predicts the experimental data on the velocity and vertical temperature distribution well. The model is based on the partial combustion of entrained air and assumed top-hat distributions for various property and flow parameters inside the fire. Quantitative agreement is obtained by using a value of 0.15 for the entrainment coefficient and 0.45 for the mixing efficiency factor. The model also predicts the fire necking.
Total materials systems requirements, and government and industry programs are outlined along with a new fire test methodology, and the potential decrease in post crash fire hazards. The flammability, smoke and toxicity goals, and the scope of materials systems are tabulated.
GRCop-42 is a high conductivity, high-strength dispersion strengthened copper-alloy for use in high heat flux applications such as liquid rocket engine combustion devices. This alloy is part of the family of NASA-developed GRCop, copper-chrome-niobium alloys. GRCop alloys were developed for harsh environments specific to regeneratively-cooled combustion chambers and nozzles with good oxidation resistance. Significant development was completed on the GRCop-84 and GRCop-42 alloys in the extruded wrought form demonstrating feasibility for combustion chambers. NASA has recently developed a process for additive manufacturing, specifically Powder Bed Fusion (PBF) or Selective Laser Melting (SLM), of GRCop-42 to establish parameters, characterize the material, and complete testing of components with complex internal features. This evolution of the GRCop-42 was based on the successful predecessor development work using GRCop-84 with the motivation of establishing a new copper-alloy option for use in NASA, government, and industry programs with SLM. A few advantages have been shown with the GRCop-42 that include higher conductivity and faster build speeds over the GRCop-84, and a simplified powder supply chain. Initial property development has shown that it is possible to produce high density builds with strengths equivalent to wrought GRCop-42 and a conductivity greater than GRCop-84. The GRCop-42 has completed process development and initial properties have been established. Several demonstrator combustion chambers have also been fabricated with the SLM GRCop-42 that include integral channels and closeouts. Additional test units have been fabricated and are completing substantial hot-fire testing to demonstrate performance of the material, process, and design.
The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. However, POCs are now being used to store combustible TRU waste at Department of Energy (DOE) sites. At the request of DOE’s Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), starting in 2015 SNL conducted a new series of fire tests to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to over-pressurize and release its inner content. Tests conducted during 2015 and 2016, and described herein, were done in two phases. The goal of the first phase was to see if the PC would reach high enough temperatures to decompose typical combustible materials inside the PC. The goal of the second test phase was to determine under what heating loads (i.e., incident heat fluxes) the 7A drum lid pops off from the POC drum. This report will describe the various tests conducted in phase I and II, present preliminary results from these tests, and discuss implications for the POCs.
The Pipe Overpack Container (POC) was developed at Rocky Flats to transport plutonium residues with higher levels of plutonium than standard transuranic (TRU) waste to the Waste Isolation Pilot Plant (WIPP) for disposal. In 1996 Sandia National Laboratories (SNL) conducted a series of tests to determine the degree of protection POCs provided during storage accident events. One of these tests exposed four of the POCs to a 30-minute engulfing pool fire, resulting in one of the 7A drum overpacks generating sufficient internal pressure to pop off its lid and expose the top of the pipe container (PC) to the fire environment. The initial contents of the POCs were inert materials, which would not generate large internal pressure within the PC if heated. POCs are now being used to store combustible TRU waste at Department of Energy (DOE) sites. At the request of DOE’s Office of Environmental Management (EM) and National Nuclear Security Administration (NNSA), starting in 2015 SNL conducted a series of fire tests to examine whether PCs with combustibles would reach a temperature that would result in (1) decomposition of inner contents and (2) subsequent generation of sufficient gas to cause the PC to over-pressurize and release its inner content. Tests conducted during 2015 and 2016 were done in three phases. The goal of the first phase was to see if the PC would reach high enough temperatures to decompose typical combustible materials inside the PC. The goal of the second test phase was to determine under what heating loads (i.e., incident heat fluxes) the 7A drum lid pops off from the POC drum. The goal of the third phase was to see if surrogate aerosol gets released from the PC when the drum lid is off. This report will describe the various tests conducted in phase I, II, and III, present preliminary results from these tests, and discuss implications for the POCs.
This paper gives a description of the methodology and results of J2-X Subscale Simulator (JSS) hot fire testing supporting the A3 Subscale Diffuser Test (SDT) project at the E3 test facility at Stennis Space Center, MS (SSC). The A3 subscale diffuser is a geometrically accurate scale model of the A3 altitude simulating rocket test facility. This paper focuses on the methods used to operate the facility and obtain the data to support the aerodynamic verification of the A3 rocket diffuser design and experimental data quantifying the heat flux throughout the facility. The JSS was operated at both 80% and 100% power levels and at gimbal angle from 0 to 7 degrees to verify the simulated altitude produced by the rocket-rocket diffuser combination. This was done with various secondary GN purge loads to quantify the pumping performance of the rocket diffuser. Also, special tests were conducted to obtain detailed heat flux measurements in the rocket diffuser at various gimbal angles and in the facility elbow where the flow turns from vertical to horizontal upstream of the 2nd stage steam ejector.
This task is to hot-fire test an existing Space Launch Mission (SLM) injector that is applicable for all expander cycle engines being considered for the exploration upper stage. The work leverages investment made in FY 2013 that was used to additively manufacture three injectors (fig. 1) all by different vendors..
The evaluation of a method for enhancing combustor hot-gas wall heat extraction by using hot-fire tests of a rocket engine combustor calorimeter with hot-gas wall ribs is presented. The capability for enhanced heat extraction is required to increase available turbine drive energy for high chamber pressure operation, and therefore higher overall expander cycle engine performance. Determination of the rib effectiveness for incorporation into the design of a high-performance combustor for an advanced expander cycle combustor intended for use in an orbital transfer vehicle or advanced space engine, was the objective of these tests.
The National Aeronautics and Space Administration has undertaken a project to restore full-scale thermal-vacuum and altitude hot fire rocket testing capability within the United States by the end of 2020. The restoration of the In Space Propulsion (ISP) facility at the Glenn Research Center's Plum Brook Station in Sandusky Ohio will accommodate full-scale long duration cryogenic stage testing in a simulated space environment as well as hot-fire testing at altitudes up to 120,000 ft. The reference test article for the restoration is a 30,000lb thrust LOX/LH2 stage with a 300 second burn duration. This presentation will describe the scope and progress of the restoration, current capabilities, and planned and potential uses for the facility once fully restored.
The five relative energy release criteria (RERC) which are a first step towards formulating a unified concept that can be applied to the development of fires in enclosures, place upper bounds on the rate and amount of energy released during a fire. They are independent, calculated readily, and may be applied generally to any enclosure regardless of size. They are useful in pretest planning and for interpreting experimental data. Data from several specific fire test programs were examined to evaluate the potential use of RERC to provide test planning guidelines. The RERC were compared with experimental data obtained in full-scale enclosures. These results confirm that in general the RERC do identify the proper limiting constraints on enclosure fire development and determine the bounds of the fire development envelope. Plotting actual fire data against the RERC reveals new valid insights into fire behavior and reveals the controlling constraints in fire development. The RERC were calculated and plotted for several descrpitions of full-scale fires in various aircraft compartments.
The purpose of this experimental research was to compare Marshall Space Flight Center's electrets with Thiokol's fixed flow air samplers during the Space Shuttle Solid Rocket Booster Demonstration Model-3 static test firing on October 19, 1978. The measurement of rocket exhaust effluents by Thiokol's samplers and MSFC's electrets indicated that the firing of the Solid Rocket Booster had no significant effect on the quality of the air sampled. The highest measurement by Thiokol's samplers was obtained at Plant 3 (site 11) approximately 8 km at a 113 degree heading from the static test stand. At sites 11, 12, and 5, Thiokol's fixed flow air samplers measured 0.0048, 0.00016, and 0.00012 mg/m3 of CI. Alongside the fixed flow measurements, the electret counts from X-ray spectroscopy were 685, 894, and 719 counts. After background corrections, the counts were 334, 543, and 368, or an average of 415 counts. An additional electred, E20, which was the only measurement device at a site approximately 20 km northeast from the test site where no power was available, obtained 901 counts. After background correction, the count was 550. Again this data indicate there was no measurement of significant rocket exhaust effluents at the test site.
As part of the Combustion Stability Tool Development project funded by the Air Force Space and Missile Systems Center, the NASA Marshall Space Flight Center designed, fabricated, assembled and hot-fire tested an oxygen/hydrocarbon propellant multi-element integrated test article that included an oxidizer-rich oxygen/hydrocarbon propellant preburner and a staged-combustion main injector. Also as part of this project, the Air Force Research Laboratory fabricated single-element main injectors of the same designs as used in the NASA multi-element injectors, and tested them in a staged-combustion integrated test article that used an oxidizer-rich oxygen/hydrogen propellant preburner. Final results of the multi-element and single-element staged-combustion main injector test programs are described in companion papers at this JANNAF meeting. The design, development, and preliminary test results of these main injectors have also been described in previous JANNAF papers. The main injector element designs were all based on relatively conventional gas-centered swirl coaxial injector element configurations such as used in Russian RD-170 and NK-33 engines, and planned for use in future U.S.-built experimental engine systems such as the Hydrocarbon Boost program demonstration engine. Four different elements were tested in both the multi-element and single-element main injectors, at similar combustion chamber pressures, chamber contraction ratios, and mixture ratios. Variations of the element features included recess depth, fuel gap width, and the presence of the sleeve separating the swirling fuel flow from the axial oxidizer flow. This paper compares the hydraulics, combustion performance, stability, and compatibility characteristics of the single-element and multi-element injectors operated at similar conditions. The single-element hardware is shown to have captured a significant level of the operability of the multi-element hardware.
This report will describe the one test conducted during phase III of the Pipe Overpack Container (POC) test campaign, present preliminary results from these tests, and discuss implications for the Criticality Control Overpack (CCO). The goal of this test was to see if aerosol surrogate material inside the Criticality Control Container (CCC) gets released when the drum lid of the CCO comes off during a thirty-minute long, fully-engulfing, fire test. As expected from POC tests conducted in Phase I and II of this test campaign, the CCO drum lid is ejected about one minute after the drum is exposed to fully-engulfing flames. The remaining pressure inside the drum is high enough to eject the top plywood dunnage a considerable distance from the drum. Subsequently, most of the bottom plywood dunnage supporting the CCC burns off during and after the fire. High pressure buildup inside the CCC and inside two primary containers holding the surrogate powder also results in damage to the filter media of the CCC and the filter-house, thread attachment of the primary canisters. No discernable release of surrogate powder material was detected from the two primary containers when pre- and post-test average mass were compared. However, when the average masses are corrected to account for possible uncertainties in mass measurements, error overlap does not preclude the possibility that some surrogate powder mass may have been lost from these primary canisters. Still, post-test conditions of the secondary canisters enclosing these two primary canisters suggest it is very unlikely this mass loss would have escaped into the CCC.
Additive Manufacturing (AM) is an emerging technology with a focus on complex metallic component fabrication: Enables complex shapes and internal features that were not possibly with traditional manufacturing techniques, and significant schedule and overall lifecycle cost reductions. To date at the NASA Marshall Space Flight Center (MSFC), combustion devices component hardware ranging in size from 100 - 35,000 lbf has been designed and manufactured using AM and many of these pieces have been hot-fire tested.
One safety concern for the storage of nuclear or hazardous materials within the Department of Energy (DOE) complex is the pressure response behaviors of Primary Containment Vessels (PCVs) of a 9975 shipping package. Although there are many conservative estimates for the pressure response behavior of PCV in high temperature environments, these estimations remain unchecked by experiment. Conservative estimates frequently build in large safety margins which result in a reduced operating range and potentially unnecessary operation restrictions. In an attempt to alleviate some of these barriers, Nuclear & Criticality Safety Engineering (N&CSE) has requested the fire testing of primary containment vessels.
Three large open pool fire experiments involving a calorimeter the size of a spent fuel rail cask were conducted at Sandia National Laboratories Lurance Canyon Burn Site. These experiments were performed to study the heat transfer between a very large fire and a large cask-like object. In all of the tests, the calorimeter was located at the center of a 7.93-meter diameter fuel pan, elevated 1 meter above the fuel pool. The relative pool size and positioning of the calorimeter conformed to the required positioning of a package undergoing certification fire testing. Approximately 2000 gallons of JP-8 aviation fuel were used in each test. The first two tests had relatively light winds and lasted 40 minutes, while the third had stronger winds and consumed the fuel in 25 minutes. Wind speed and direction, calorimeter temperature, fire envelop temperature, vertical gas plume speed, and radiant heat flux near the calorimeter were measured at several locations in all tests. Fuel regression rate data was also acquired. The experimental setup and certain fire characteristics that were observed during the test are described in this paper. Results from three-dimensional fire simulations performed with the Cask Analysis Fire Environment (CAFE) fire code are also presented. Comparisons of the thermal response of the calorimeter as measured in each test to the results obtained from the CAFE simulations are presented and discussed.
NASA and industry partners are working towards fabrication process development to reduce costs and schedules associated with manufacturing liquid rocket engine components with the goal of reducing overall mission costs. One such technique being evaluated is powder-bed fusion or selective laser melting (SLM), commonly referred to as additive manufacturing (AM). The NASA Low Cost Upper Stage Propulsion (LCUSP) program was designed to develop processes and material characterization for GRCop-84 (a NASA Glenn Research Center-developed copper, chrome, niobium alloy) commensurate with powder-bed AM, evaluate bimetallic deposition, and complete testing of a full scale combustion chamber. As part of this development, the process has been transferred to industry partners to enable a long-term supply chain of monolithic copper combustion chambers. To advance the processes further and allow for optimization with multiple materials, NASA is also investigating the feasibility of bimetallic AM chambers. In addition to the LCUSP program, NASA has completed a series of development programs and hot-fire tests to demonstrate SLM GRCop-84 and other AM techniques. NASA's efforts include a 4K lbf thrust liquid oxygen/methane (LOX/CH4) combustion chamber and subscale thrust chambers for 1.2K lbf LOX/hydrogen (H2) applications that have been designed and fabricated with SLM GRCop-84. The same technologies for these lower thrust applications are being applied to 25-35K lbf main combustion chamber (MCC) designs. This paper describes the design, development, manufacturing and testing of these numerous combustion chambers, and the associated lessons learned throughout their design and development processes.