Study of space battery accelerated testing techniques. Phase 1 report. Survey of testing methods applicable to space battery evaluation
Testing methods applicable to space battery evaluation - literature survey
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Testing methods applicable to space battery evaluation - literature survey
Nondestructive test methods and techniques including computer programs and data reduction
High pressure gaseous oxygen impact testing method incorporating drop plummet system for specimens flammability screening
Fire tests were conducted in a 737 airplane fuselage at NASA-JSC to characterize jet fuel fires in open steel pans (simulating post-crash fire sources and a ruptured airplane fuselage) and to characterize fires in some common combustibles (simulating in-flight fire sources). Design post-crash and in-flight fire source selections were based on these data. Large panels of airplane interior materials were exposed to closely-controlled large scale heating simulations of the two design fire sources in a Boeing fire test facility utilizing a surplused 707 fuselage section. Small samples of the same airplane materials were tested by several laboratory fire test methods. Large scale and laboratory scale data were examined for correlative factors. Published data for dangerous hazard levels in a fire environment were used as the basis for developing a method to select the most desirable material where trade-offs in heat, smoke and gaseous toxicant evolution must be considered.
The sandwich beam in a four-point bending compressive test method for advanced composites is evaluated. Young's modulus and Poisson's ratio were obtained for graphite/polyimide beam specimens tested at 117 K, room temperature, and 589 K. Tensile elastic properties obtained from the specimens were assumed to be equal to the compressive elastic properties and were used in the analysis. Strain gages were used to record strain data. A three-dimensional finite-element model was used to examine the effects of the honeycomb core on measured composite mechanical properties. Results of the analysis led to the following conclusions: (1) a near uniaxial compressive stress state existed in the top cover and essentially all the compressive load was carried by the top cover; (2) laminate orientation, test temperature, and type of honeycomb core material were shown to affect the type of beam failure; and (3) the test method can be used to obtain compressive elastic constants over the temperature range 117 to 589 K.
A simple test method for large deformation bending of thin composite laminates is investigated using image processing and full-field strain measurements. The assumptions and kinematic equations that represent the test are used to calculate numerically the laminate bending stiffness and strength as well as the curvature and strains at failure. In order to validate the test methodology, a comparison is performed between analytical model predictions and empirical data in terms of computed surface strains versus digital image correlation data and calculated rotation angles of the fixture arms throughout the test versus measured ones. The new test method is then used to calculate the bending stiffness in the D11 and D22 directions as well as failure strains for various thin-ply laminates of interest. These parameters are ultimately compared with predicted values using micromechanics and classical lamination theory analysis. In general, bending stiffness and strain test results and predictions for 0 degree orientation coupons have a maximum difference of 10% and 35%.
In this paper an improved sub-component fatigue testing method is proposed, in which structural optimization is used to obtain specimens in which fatigue failure is precipitated in the designated area away from the boundaries, i.e., load application and fixture points. This is achieved by optimizing the nonlinear beam taper and the dynamic excitation. The major requirement for accurate material characterization through sub-component tests concerns unbiased stress states in the gauge section. However, empiricism shows that many sub-component high-cycle fatigue testing methods suffer from failure in the boundaries rather than the gauge section, which causes bias. The common practice for reinforcing those regions only shifts the issue into new areas of local discontinuities where failure is still caused remotely from the gauge section. An experimental proof of concept demonstrates that optimization of the beam taper can be used to obtain unbiased fatigue test data.
Double torsion testing can produce fracture toughness values without crack length measurement that are comparable to those measured via standardized techniques such as the chevron-notch, surface-crack-in-flexure and precracked beam if the appropriate geometry is employed, and the material does not exhibit increasing crack growth resistance. Results to date indicate that 8 < W/d < 80 and L/W > 2 are required if crack length is not considered in stress intensity calculations. At L/W = 2, the normalized crack length should be 0.35 < a/L < 0.65; whereas for L/W = 3, 0.2 < a/L < 0.75 is acceptable. In addition, the load-points need to roll to reduce friction. For an alumina exhibiting increasing crack growth resistance, values corresponding to the plateau of the R-curve were measured. For very thin plates (W/d > 80) nonlinear effects were encountered.
A novel indirect tensile test method, the biaxial flexure test (BFT) method, has been developed to measure the biaxial tensile strength of concretes. The classical modulus of rupture (MOR) test has been generalized to three dimensions. In this method, we use a circular plate as the new test specimen. This plate is supported by an annular ring. We apply an external load to this specimen through a circular edge. The centers of the specimen, the loading device and the support are identical. The biaxial tensile strength measured by this new method is about 19% greater than the uniaxial tensile strength obtained from the classical modulus of rupture test as reported by other researchers. However, at the same time, we also found that the stochastic deviation of the biaxial tensile strength is about 63% greater than the uniaxial strength.
Sensors and sensor systems for monitoring fine particles with aerodynamic diameters smaller than 2.5 µm can provide real-time feedback on indoor air quality and thus can help guide actions to manage indoor air pollutant concentrations. Standardized verification of the performance and accuracy of sensors and sensor systems is crucial for predicting the efficacy of such monitoring. A new ASTM International standard test method (ASTM D8405) was created for this need and is the most exacting laboratory protocol published to date for evaluating indoor air quality sensors and sensor systems measuring particles smaller than 2.5 µm in diameter. ASTM D8405 subjects sensors and sensor systems to five test phases: (1) an initial particle concentration ramp; (2) exposure to various temperature and humidity conditions; (3) exposure to interfering particles; (4) temperature cycling; and (5) a final particle concentration ramp to assess drift. This paper discusses the development of the standard test method, key aspects of the testing process, example evaluation results, and a comparison of this standard test method against peer evaluation protocols.
This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.
An overview of the current state of the art multiple-input, multiple-output modal testing technology is discussed. A very brief review of the current time domain methods is given. A detailed review of frequency and spatial domain methods is presented with an emphasis on sine testing.
A test apparatus and method of its use for evaluating various performance aspects of a test specimen is disclosed. A chamber within a housing contains a cold mass tank with a contact surface in contact with a first surface of a test specimen. The first surface of the test specimen is spaced from the second surface of the test specimen by a thickness. The second surface of the test specimen is maintained at a a constant temperature by a liquid disposed within the cold mass tank. A boil-off flow rate of the gas is monitored and provided to a processor along with the temperature of the first and second surfaces of the test specimen. The processor calculates thermal insulation values of the test specimen including comparative values for heat flux and apparent thermal conductivity k-value). The test specimen may be placed in any vacuum pressure level ranging from about 0.01 millitorr to 1,000,000 millitorr with different residual gases as desired. The test specimen may be placed under a mechanical load with the cold mass tank and another factors may be imposed upon the test specimen so as to simulate the actual use conditions.
A test apparatus and method of its use for evaluating various performance aspects of a test specimen is disclosed. A chamber within a housing contains a cold mass tank with a contact surface in contact with a first surface of a test specimen. The first surface of the test specimen is spaced from the second surface of the test specimen by a thickness. The second surface of the test specimen is maintained at a desired warm temperature. The first surface is maintained at a constant temperature by a liquid disposed within the cold mass tank. A boil-off flow rate of the gas is monitored and provided to a processor along with the temperature of the first and second surfaces of the test specimen. The processor calculates thermal insulation values of the test specimen including comparative values for heat flux and apparent thermal conductivity (k-value). The test specimen may be placed in any vacuum pressure level ranging from about 0.01 millitorr to 1,000,000 millitorr with different residual gases as desired. The test specimen may be placed under a mechanical load with the cold mass tank and another factors may be imposed upon the test specimen so as to simulate the actual use conditions.
Electric water heaters have long been used as a tool for demand response due to their inherent thermal storage and large electric load. Traditionally, electric water heaters have been controlled by external load control switches, but that type of control does not work well with more efficient heat pump water heaters and cannot ensure that consumers have adequate hot water. Water heater manufacturers are adding more sophisticated controls that allow utilities or consumers to control their water heaters in new ways that can provide demand response without impacting consumer comfort. Further, the electric utility grid has seen a rapid increase the availability of renewable energy, which, depending on the type of renewable energy, can provide large amounts of energy for a portion of the day, but reduced or no energy at other times. In response to these advances in controls, availability of periodic renewable energy, and in an effort to have a standard which can be applied at a national level, ENERGY STAR and the Department of Energy have developed a Product Specification and Test Method for Connected Residential Water Heaters. In this session, we will discuss the new specification and test method, as well as show some initial results from running the new test method with two different HPWHs at NREL.
The JWST IEC conformal shields are mounted onto a composite frame structure that must undergo qualification testing to satisfy mission assurance requirements. The composite frame segments are bonded together at the joints using epoxy, EA 9394. The development of a test method to verify the integrity of the bonded structure at its operating environment introduces challenges in terms of requirements definition and the attainment of success criteria. Even though protoflight thermal requirements were not achieved, the first attempt in exposing the structure to cryogenic operating conditions in a thermal vacuum environment resulted in approximately 1 bonded joints failure during mechanical pull tests performed at 1.25 times the flight loads. Failure analysis concluded that the failure mode was due to adhesive cracks that formed and propagated along stress concentrated fillets as a result of poor bond squeeze-out control during fabrication. Bond repairs were made and the structures successfully re-tested with an improved LN2 immersion test method to achieve protoflight thermal requirements.
Significant contributions of the three major areas of composite mechanics to the development of test methods are illustrated with selected examples. The areas of composite mechanics include composite micromechanics, composite macromechanics, and laminate theory. The examples can be considered to be representative of the contribution of composite mechanics to the development of composite test methods. The specific examples describe contributions such as criteria for selecting resin matrices for improved composite strength, the 10 deg off-axis tensile test, procedures for configuring hybrids, and the concept of 'reduced bending rigidities'. The pertinent composite mechanics equations associated with each contribution are given and supplemented by tabular and/or graphical data which illustrate the significance of the contribution.
A study was conducted to improve the correlation between the electromagnetic compatibility (EMC) analysis models stated in MIL-STD-1541A and the suggested testing methods used for space systems. The test and analysis methods outlined in MIL-STD-1541A are described, and a comparative assessment of testing and analysis techniques as they relate to several EMC areas is presented. Suggestions on present analysis and test methods are introduced to harmonize and bring the analysis and testing tools in MIL-STD-1541A into closer agreement. It is suggested that test procedures in MIL-STD-1541A must be improved by providing alternatives to the present use of shielded enclosures as the primary site for such tests. In addition, the alternate use of anechoic chambers and open field test sites must be considered.