At least 73 records · Page 4

Integrating Atmospheric Specifications into Seismoacoustic Event Localization

This report investigates the integration of infrasound and seismic data to improve event localization accuracy, specifically focusing on a surface explosion at the Utah Training and Testing Range (UTTR). Utilizing the Seismoacoustic Bayesian Event Locator (SABEL) framework, we incorporated atmospheric specifications derived from Ground to Space (G2S) profiles to enhance celerity-range priors. Our analysis revealed that while the combination of infrasound and seismic observations significantly reduced localization uncertainty, challenges remained, particularly with returns at distances less than 200 km from the source and the influence of specific observations on location estimates. The results indicate that broader celerity distributions, such as those from Blom et al. (2020), facilitate better alignment with ground truth locations compared to narrower models. Overall, this work demonstrates the promise of seismoacoustic approaches in refining event localization and highlights the need for further exploration of celerity-range models to ensure reliable outcomes.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Best Practices for Body Temperature Measurement with Infrared Thermography: External Factors Affecting Accuracy

Infrared thermographs (IRTs) are commonly used during disease pandemics to screen individuals with elevated body temperature (EBT). To address the limited research on external factors affecting IRT accuracy, we conducted benchtop measurements and computer simulations with two IRTs, with or without an external temperature reference source (ETRS) for temperature compensation. The combination of an IRT and an ETRS forms a screening thermograph (ST). We investigated the effects of viewing angle (θ, 0–75°), ETRS set temperature (T ETRS , 30–40 °C), ambient temperature (T atm , 18–32 °C), relative humidity (RH, 15–80%), and working distance (d, 0.4–2.8 m). We discovered that STs exhibited higher accuracy compared to IRTs alone. Across the tested ranges of T atm and RH, both IRTs exhibited absolute measurement errors of less than 0.97 °C, while both STs maintained absolute measurement errors of less than 0.12 °C. The optimal T ETRS for EBT detection was 36–37 °C. When θ was below 30°, the two STs underestimated calibration source (CS) temperature (T CS ) of less than 0.05 °C. The computer simulations showed absolute temperature differences of up to 0.28 °C and 0.04 °C between estimated and theoretical temperatures for IRTs and STs, respectively, considering d of 0.2–3.0 m, T atm of 15–35 °C, and RH of 5–95%. The results highlight the importance of precise calibration and environmental control for reliable temperature readings and suggest proper ranges for these factors, aiming to enhance current standard documents and best practice guidelines. These insights enhance our understanding of IRT performance and their sensitivity to various factors, thereby facilitating the development of best practices for accurate EBT measurement.

47 OTHER INSTRUMENTATION↗

Statistical Correlation of Heliostat Pointing Deviation With Wind

This work was carried out as part of the Heliostat Consortium (HelioCon) Field Deployment subtask with the aim to develop a reduced order model framework for correlating wind speed and pointing deviation of a heliostat facet. There are only sparse field measurements of heliostat pointing deviations and accompanying wind conditions published in the literature. Heliostat test standards, such as IEC 62862-4-3, propose a suite of tests including laser pointing repeatability at wind speeds below 4 m/s, and provide technical requirements for heliostat slope and tracking deviations in coarse average wind speed bins of 4 m/s, 6 m/s, and 8 m/s. In addressing the gap of the variation of heliostat pointing deviation with wind speed, field measurements of laser pointing on a grid target and wind conditions were analyzed in this study at the Third-Party Metrology Platform at the National Laboratory of the Rockies (NLR) Flatirons Campus. Horizontal pointing deviations were found to follow a logarithmic relationship with peak wind speed, whereas vertical pointing deviations follow an exponential relationship with peak wind speed. Both horizontal and vertical pointing deviations also follow a second order polynomial relationship, as expected from the proportionality of elastic loads and deformations with the square of wind speed. The results indicate that heliostat facet pointing deviations in the vertical direction increase at a faster rate than in the horizontal direction with increasing wind speed over the tested range, however these are dependent on the heliostat structural design. Next steps are recommended for additional field measurements to confirm a linear relationship of pointing deviation with applied moment on a heliostat facet, and to distinguish between gravity-induced and wind-induced pointing deviations at different elevation angles. The derived correlations in the preliminary analysis in this report serve as a case study for heliostat developers and plant operators to estimate the wind-induced pointing deviations and their variation with peak gust wind speed. Next steps in future work would recommend higher resolution and longer duration datasets for different elevation angles and wind directions to reduce uncertainties and variance of collected laser beam spot data and their correlations with bin-averaged wind speed.

17 WIND ENERGY↗

Characterization of Advanced Manufactured Surface Acoustic Wave Sensor for Temperature Measurement in Nuclear Applications

As part of a collaborative effort between Idaho National Laboratory and the Boise State University, printed SAW transducers were developed. The transducers were first modelled and evaluated for optimum performance, then fabricated using several piezoelectric substrates. These printed SAW-sensors were tested for temperature sensing ability and found to be highly sensitive and with a very linear response over the tested range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrating Overhead Camera Imagery with Reinforcement Learning to Improve Fuel Economy Through Adaptive Traffic Control

Overhead cameras have been deployed for some time as a sensor for traffic control, with many advantages over conventional inductive loop sensors in terms of robustness, ease of installation, and simplicity with respect to maintenance. We explore the utility of such imagery (in particular, fisheye lens cameras) for intelligent traffic control in real-time using reinforcement learning, with a goal of improving fuel economy for the overall intersection and grid of intersections. We summarize our initial work in data collection and approach to ascertain the ability to visually sense vehicular fuel consumption using real-world data. We then describe our deep reinforcement learning topology to test adaptive control informed by the camera capabilities. Next, we tested the proof-of-concept through a variety of simulation scenarios using the Simulation of Urban Mobility (SUMO) traffic simulator, which included different estimates on vehicle classifications, different traffic distributions, and different traffic densities. Six different control policies were tested ranging from simple timing, to heuristic visual-based methods, to actual policies learned via the reinforcement learning approach. Our results demonstrate the feasibility of the approach for controlling traffic lights for better fuel efficiency based on visual vehicle estimates from commercial, fisheye lens cameras.

Karnowski, Thomas↗

Synchrophasors-based Master State Awareness Estimator for Cybersecurity in Power Grid: Testbed Implementation & Field Demonstration

The integration of distributed energy resources(DERs) and expansion of complex network in the distribution grid requires an advanced distributed state estimator to monitor the grid health at micro-level. The distribution state estimator will improve the situational awareness and resiliency of distributed power system. This paper proposes a synchrophasors-based master state awareness (MSA) estimator to enhance the cybersecurity in distribution grid by providing a real-time estimation of system operating states to control center operators. In this paper, the proposed MSA estimator utilizes only phasor measurements, bus magnitudes and angles, from phasor measurement units (PMUs),deployed in local substations, to estimate the system states and also detects data integrity attacks, such as load tripping attack that disconnects the load. To validate the proof of concept, we implement the proposed methodology in cyber-physical testbed environment at the Idaho National Laboratory (INL) Electric Grid Security Testbed. Further, to address the “valley of death” and support technology commercialization, field demonstration is also performed at the Critical Infrastructure Test Range Complex(CITRC) at the INL. Our experimental results reveal a promising performance in detecting load tripping attack and providing an accurate situational awareness through an alert visualization dashboard in real-time

42 ENGINEERING↗

Acoustic Monitoring of Pyroprocessing Equipment

This paper provides an introduction to using acoustic monitoring to advance detection techniques for pyroprocessing in support of nuclear safeguards and non-proliferation. The usage of free air acoustic monitoring has been previously demonstrated at Idaho National Laboratory (INL) facilities such as the Advanced Test Reactor and the National Security Test Range. However, the proposed work revolves around a new deployment environment, the Fuel Conditioning Facility, that brings forward several questions regarding the performance of the technology in non-free air media. The confinement of the pyroprocessing equipment to a heavily shielded hot cell, the atmosphere of the hot cell containing argon gas, and the radiation dose inside the hot cell are all new environments for acoustic monitoring. To our knowledge, acoustic measurements have not been completed in such an environment before. This offers a new opportunity to study not only the acoustic signatures of the equipment inside of the hot cell, but also the propagation of the signals through the hot cell and at distances away from their origination. The objective of this paper is to explain the planned instruments to monitor the Fuel Conditioning Facility in order to evaluate acoustic signals emitted from equipment during various stages of operation. Identifying these signals can potentially enable the identification of specific pieces of equipment used in pyroprocessing and produce information of their operational status. If successful, this type of monitoring could offer a new method to aid in safeguards and proliferation detection of pyroprocessing activities.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Low Level Radon Concentration and Radon Daughter Dose Monitoring in an Arid-zone Waste Store - 20081

Radioactive waste containing predominantly soil and rubble from the clean-up of a former uranium and thorium minerals processing research facility is currently stored at the Woomera Test Range in South Australia awaiting final disposal. Prior to commencing any manipulation of the nearly 10,000 waste drums (205 L or 55 gallon each), radon concentration monitoring and radon daughter dosimetry has been undertaken to (i) gain understanding of the temporal and spatial variation of radon and its daughters within the storage facility, which could provide insights into the radiological source term and (ii) confirm that radiological risks to workers are below the guideline values. A time series of nearly 12 months of detailed observations shows low level radon concentrations with annual average values that are slightly above the average radon concentrations in Australian homes. Peak values in summer are about three times higher than the annual average based on the CRM measurements. Both radon concentrations and annual effective dose are well below the regulatory limits. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comprehensive Baseline Environmental Monitoring of an Interim Legacy Waste Store in Arid Zone Australia - 20062

Radionuclide containing soil and rubble from the clean-up of a former uranium, thorium and rare earth minerals processing research facility carried out in the early 50's and 60's is currently stored at the Woomera Test Range in South Australia awaiting final disposal. Prior to developing a final disposal pathway commensurate with waste acceptance criteria, a comprehensive baseline environmental monitoring has been carried out to establish the background radiation levels. The survey included in situ gamma scanning of the surface soil ({sup 238}U, {sup 232}Th, {sup 40}K), a laboratory analysis of 86 soil samples (from 0-20 cm depth), which involved XRF measurements (U, Th, and rare earth metals) and spectroscopic analysis ({sup 238}U, {sup 232}Th, {sup 226}Ra and daughter nuclides). A time series of radon concentration measurements in air was established, while soil radon ({sup 222}Rn) and thoron ({sup 220}Rn) flux measurements were undertaken at 18 different locations. The 2018 comprehensive baseline survey demonstrated radiation levels in the immediate vicinity of the Woomera interim waste store are typical background values of soil and rock. No contamination was detected. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimentation on Finned-Tube Microchannel Heat Exchanger Incorporating Phase Change Material and R-410A

Integrating latent heat thermal energy storage, particularly phase change materials (PCM), in building heating, ventilation, air conditioning, and refrigeration (HVAC&R) systems, offers substantial benefits for peak load shifting and energy efficiency. While numerous studies explore PCM-embedded heat exchangers (PCM-HX) using single-phase heat transfer fluids, there needs to be more investigation regarding PCM-HX utilizing two-phase refrigerant flow. This gap is even more pronounced for microchannel heat exchanger (MCHX) configurations. In this study, an MCHX-based PCM-HX was built and tested to analyze and evaluate the performance of a PCM-HX operating with a two-phase refrigerant as the working fluid. A commercially available MCHX condenser unit was embedded with 2.6 kg of RT35 PCM and tested using R-410A as the working fluid, using an in-house test loop to control the refrigerant inlet conditions precisely. Thin and minimally invasive T-type thermocouples traced the temperature evolution along MCHX channels and tube banks. Additional larger T-type thermocouple probes at the refrigerant inlet and outlet measured the average power of the PCM-HX during condensing tests, ranging from 0.7 kW to 1.6 kW based on mass flow rates varying from 3.5 g/s to 8 g/s. This experimental study on MCHX-based PCM-HX with a two-phase refrigerant has the potential to offer practical design guidelines for the direct integration of PCM-TES in HVAC&R systems without the use of a secondary loop, while caution is advised to avoid a substantial increase in the refrigerant charge amount.

42 ENGINEERING↗

Acoustic Measurements of Solvent Extraction Processes in Support of Safeguards

The proposed poster focuses on using acoustic monitoring to advance detection techniques for reprocessing equipment in support of nuclear safeguards. The usage of free air acoustic monitoring has been previously demonstrated at Idaho National Laboratory (INL) at facilities such as the Advanced Test Reactor and the National Security Test Range. However, this work focuses on a deployment environment dedicated to monitoring separation processes, using solvent extraction equipment such as centrifugal contactors. This environment offers an opportunity for signal discovery and in characterizing acoustic signatures of the equipment in operation. This data can support the development of safeguards by design and security by design measures for aqueous reprocessing facilities. Furthermore, this type of monitoring can aid in early detection and identification of removed materials indicating diversion, which is essential for initiating material recovery and actor identification. The results of this work include data from nine low-frequency acoustic sensors used to investigate potential acoustic characteristics of centrifugal contactors used in multi-stage processes. The results also discuss the correlation between the signatures and the operation of the contactor banks.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

SULI End of Summer Presentation

This presentation made on Power Point is a brief summary of my work enhancing the Supervisory Control and Data Acquisition (SCADA) architecture for Idaho National Lab’s Critical Infrastructure Test Range Complex (CITRC). This work was part of an on-going project to create a digital twin of CITRC that will be implemented for resiliency research. Resiliency is growing more important as extreme weather, aging infrastructure, and increasing load all exert stress on the United States power grid. This presentation highlights how I documented the existing devices and data flow on site and then updated specific device settings to better support the needs of the project. It also examines future use of this data in the digital twin data warehouse (DeepLynx), and future Artificial Intelligence and Advanced Distribution Management System applications. It will be presented to the B751 Water and Energy Systems Analysis group at INL during my last week.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

DUKE PRO STI TEST at 9965 - RANGE 1 (IMPACT NOISE). Survey Profile Report

Members of the Workforce (MOW) who are exposed to noise levels above 140 dBC, regardless of hearing protection worn, are required to be enrolled into the SNL Hearing Conservation Program which includes audiometric testing, online training (HCP100) and wearing hearing protection. Based on the area impact noise sample results, the attenuation provided by the MFCP was protective for mitigating noise to levels below the ACGIH TLV of 140 dBC. The results also validated the scaled distance equation in an open-air environment as the results at K635 (864 feet) were below 140 dBC.

54 ENVIRONMENTAL SCIENCES↗

A MEMS dynamic mechanical analyzer for in situ viscoelastic characterization of 3D printed nanostructures

Cellular metamaterial structures with sub-micron features have shown the ability to become excellent energy absorbing materials for impact mitigation due to the enhanced mechanical properties of materials at the nanoscale. However, in order to optimize the design of these energy absorbing metamaterial structures we need to be able to measure the dynamic properties of the sub-micron features such as storage and loss moduli and the loss factor. Therefore, at scale testing is required to capture the scale, temperature, and strain rate dependent material properties of these nanoscale materials. This study presents the design, fabrication, and calibration of a MEMS-based dynamic mechanical analyzer (DMA) that can be directly integrated with the two photon lithography (TPL) process commonly used to fabricate metamaterial structures with nanoscale features. The MEMS-based DMA consists of a chevron style thermal actuator used to generate a tensile load on the structure and two differential capacitive sensors on each side of the structure used to measure load and displacement. This design demonstrated 1.5 ± 0.75 nm displacement resolution and 104 ± 52 nN load resolution, respectively. Dynamic mechanical analysis was successfully conducted on a single nanowire feature printed between the load and displacement stages of the MEMS device with testing frequencies ranging between 0.01–10 Hz and testing temperatures ranging between 22 °C–47 °C. These initial tests on an exemplar TPL part demonstrate that the printed nanowire behaves as a viscoelastic material wherein the transition from glassy to viscous behavior has already set in at the room temperature.

42 ENGINEERING↗

Single-Bar SMT Creep-Fatigue Testing on Alloy 617 with Software Controls on elastic Follow-Up Feedback in Support of New Creep-Fatigue Design Methodology

The Simplified Model Test (SMT) is one of the alternative ways to calculate the creep-fatigue damage of elevated temperature components. The SMT approach unifies the creep and fatigue damage, simplifying the damage calculation process with improved accuracy. Traditionally, SMT tests has have been conducted through the two bars: first is the driver bar and second is the test bar. The driver bar stays elastic and imposes the confinement to the second bar. This experimental procedure requires two test frames and a large test specimen, which limits the test parameter range and accessibility of this testing procedures. Hence, a single-bar SMT (SB-SMT) tests has been developed to simplify complexity in SMT experiment setup. The software-controlled SB-SMT test process has been introduced which completely replaces the driver bar. This paper discusses the single-bar SMT (SB-SMT) test procedure with software controls. The challenges and critical parameters in the software-controlled SB-SMT procedure are addresses addressed and recommendations are provided. A scoping test with a set of wider strain range, elastic follow-ups and dwell time validated the proposed test procedure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A sharp interface Lagrangian-Eulerian method for rigid-body fluid-structure interaction

Herein this paper introduces a sharp interface method to simulate fluid-structure interaction (FSI) involving rigid bodies immersed in viscous incompressible fluids. The capabilities of this methodology are benchmarked using a range of test cases and demonstrated using large-scale models of biomedical FSI. The numerical approach developed herein, which we refer to as an immersed Lagrangian-Eulerian (ILE) method, integrates aspects of partitioned and immersed FSI formulations by solving separate momentum equations for the fluid and solid subdomains, as in a partitioned formulation, while also using non-conforming discretizations of the dynamic fluid and structure regions, as in an immersed formulation. A simple Dirichlet-Neumann coupling scheme is used, in which the motion of the immersed solid is driven by fluid traction forces evaluated along the fluid-structure interface, and the motion of the fluid along that interface is constrained to match the solid velocity and thereby satisfy the no-slip condition. To develop a practical numerical method, we adopt a penalty approach that approximately imposes the no-slip condition along the fluid-structure interface. In the coupling strategy, a separate discretization of the fluid-structure interface is tethered to the volumetric solid mesh via stiff spring-like penalty forces. Our fluid-structure coupling scheme relies on an immersed interface method (IIM) for discrete geometries, which enables the accurate determination of both velocities and stresses along complex internal interfaces. Numerical methods for FSI can suffer from instabilities related to the added mass effect, but computational tests indicate that the methodology introduced here remains stable for selected test cases across a broad range of solid-fluid mass density ratios, including extremely small, nearly equal, equal, and large density ratios. Biomedical FSI demonstration cases include results obtained using this method to simulate the dynamics of a bileaflet mechanical heart valve in a pulse duplicator, and to model transport of blood clots in a patient-averaged anatomical model of the inferior vena cava.

97 MATHEMATICS AND COMPUTING↗

A Review of the Generic Grid-Forming Model Used by the System Operator in Chile

The objective in this project is to verify the applicability of using generic electro-magnetic transient domain models of GFM technology through a wide range of tests and system conditions proposed by subject matter experts of GFM technology through a wide range of tests and system conditions proposed by subject matter experts. For this study, we used the generic GFM electro-magnetic transient model available in the EMTP (Electromagnetic Transient Program) software library, and we assessed the model’s various GFM capabilities through 12 tests. In this report, we compare the performance of the model with that of an original equipment manufacturer (OEM) GFM model. We also share the key insights and lessons learned from this work.

24 POWER TRANSMISSION AND DISTRIBUTION↗